A navien combi boiler ncb 210 has error code E.001. A wrestling match. Check this one out.
Subscribe- / chuckbarron
kit.co/ChuckBa...
Every day plumbing repairs and installs featured all while my two sons CB2 and Angelo learn the plumbing trade.
Subscribe- / chuckbarron
Follow us on social Media
/ charles.barron.9
/ chuckbarron6
/ chuckbarron6
DISCLAIMER: This video is for entertainment purposes only. This video also contains affiliate links which if you click on link and make a purchase I may receive a small commission. This helps support the channel and helps us continue to bring you new video's like this one. Thank you so much for the support. Plumb on!
Check out some of our gear-chuckbarronplum...
#plumber
#plumbing
#plumbers
#plumbingapprentice
#plumbingrepairs
#journeymanplumber
#serviceplumbing
PLUMBING REPAIRS | NAVIEN NCB 210 | 3 WAY VALVE REPLACED

Пікірлер: 80
@thomasfallon6656
@thomasfallon6656 3 ай бұрын
I'm a service plumber in NJ, this video helped me out a lot. Thank you Sir!
@philz7542
@philz7542 2 жыл бұрын
Excellent video on replacing the 3 way valve. Thank you sooo much for the tip about reusing the old brass mount plate. Took the new washer, left off the new brass plate and reconnected the 3 way. I replaced the pump while I was at it. The clip that secures the pump was a bit of a bugger to get back into place, and I would recommend that if you're replacing the pump, that you should pre-screw the holes on the bottom around where the pump drain plug goes, so that the screws go in easily to secure it to the cabinet. I didn't really want to replace the pump, but the level 2 tech at Navien said that for sure the 3 way was pooched because we were getting bleeding back into the heating loop, when no heat was called for. The tech said that although the pump may be working, the pressure numbers coming back on the display said that the pump may be having an intermittent issue, or beginning to fail. Your video with explanation, was phenomenal. Thank you Is there a repair kit for these pumps? How do you test the pump to see if really pooched? The pumps have a screw out for the bearings , I think. They look very similar to a Grundfos heating pump.
@jakevalis6242
@jakevalis6242 3 жыл бұрын
Been in the trade a couple of years now, always reference your videos to help me learn. This is the most in-depth channel I’ve ever seen. Feels like I’m standing right next to you learning first hand. Thank you from Toms River.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
Great to hear! We neighbors
@Reese_Young
@Reese_Young 3 жыл бұрын
My love for plumbing was tested 2 weeks ago or so having to replace the same 3 way valve. Still love it but was not happy that day. I will have to keep that idea of reusing the old brass plate because thats where i ran into troubles to thanks for the tip. That would have saved a lot of swearing lol.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
Great job! painful for sure
@Ted_E_Bear
@Ted_E_Bear 3 жыл бұрын
Your work is beyond reproach !!
@ChuckBarron
@ChuckBarron 3 жыл бұрын
thanks Ted. E.
@billriga2825
@billriga2825 3 жыл бұрын
Great job Chuck, also camera work is exceptional!!!
@ChuckBarron
@ChuckBarron 3 жыл бұрын
Thank you kindly!
@frankvon3980
@frankvon3980 Жыл бұрын
CB, Nice job! Its seems like i'm standing right next to you while your doing the job.! The manufacture should have that valve facing to the left side of the panel, along with an easy access panel for easy replacement.
@ChuckBarron
@ChuckBarron Жыл бұрын
hand me my coffee please. lol
@JE27898
@JE27898 3 жыл бұрын
Maybe someday they'll make extra access panels. Nice job Chuck
@ChuckBarron
@ChuckBarron 3 жыл бұрын
That would be cool
@miketo5828
@miketo5828 3 жыл бұрын
Thanks buddy, be safe
@anniesfarmhousebarngrill446
@anniesfarmhousebarngrill446 2 жыл бұрын
Chuck barron "THANK YOU Thank you THANK YOU" FOR YOUR PERFECTLY EXPLAINED HAVIEN 3 VALVE SWITCH REPLACEMENT video. Havien said being I'm a woman that I had to have a licensed plumber call there technical support to do the job. SO I did plumber came no parts said he ordered it overnight.comes back next day.rips it apart no gaskets.my advise always replace gaskets o rings always.But no he is a professional right. Wrong. So long story short plumber leaves aggravated parts all over the place screws everywhere.House with no heat or hot water now.Temperatures in 30s 2 small children and a 80 yr old mother cold and can't shower.i call plumbing places for parts locate a place 2 hr away round trip.Great part of story wish I had someone to video tape me.I come home Watched your video 😀 Started putting it back. Together you would be proud of me and your video Chuck because I was so confident I even figured out a trick to show you how to replace the brass piece without a disaster or bigger headache. Put in all new greased o rings.Took me a little over an hour. I purged it all out to clean it And in excitement to all HEAT AND HOT WATER. 🔥 Again thank you Chuck 2 thank God for my small hands. And HAVIEN THANK PEOPLE LIKE CHUCK AND DONT TREAT WOMEN LIKE THERE STUPID BECAUSE AT LEAST NOW IM A PRO THANKS TO CHUCK. 👍 AND CAN FIX YOUR HAVIEN BETTER THEN YOUR SO CALL MALE PLUMBERS. THAT TALKED TO HAVIEN SUPPORT GOT AGGRAVATED CAUSE YOU MAKE EVERYTHING LOOK COMLICATED AND THET QUIT. HAVIEN WHEN YOU WONT EVEN GIVE A HOMEOWNER AN AVERAGE TIME FOR LABOR AND PARTS NO WONDER EVERY HOMEOWNER WANTS TO THROW YOUR PRODUCT IN TRASH. ITS A GREAT WATER HEATER AND HEAT.VERY WARM GREAT HOT WATER BUT HAVING CONTRACTORS CHARGE THOUSANDS OF DOLLARS FOR A JOB THAT TAKES AN HOUR AND PARTS WAY UNDER A 100.00 DOLLARS HIGHWAY ROBBERY .SHAME ON YOU HAVIEN. AND PUT ACCESS PANELS ON THE SIDE IT DOESNT COST YOU ANYTHING MORE GREAT PRODUCT IF YOU STOP CONTRACTORS FROM RIPPING OFF YOUE CUSTOMERS. HAVIEN IF IT REALLY TAKES YOUR LICENSED CONTRACTORS 3-12 HOURS FOR A ONE HOUR JOB AND IM JUST A BEGINNER MY 1ST TIME CALL ME INSTEAD TO ALL THE CRY BABY MEN WATCH CHUCKS VIDEOS AMAZING.AND TO ALL THE WOMEN DONT LISTEN TO HAVIEN. YOU CAN DO ANYTHING TO THANKS TO UTUBE AND CHUCK.Havien should sale your own parts also because if you didn't send me on a wild goose chase looking for parts on line like you said I never would have found Chuck 😉 and if anyone wants parts go to Roche plumbing supplies lake Ariel highway honesdale pa. Low prices also. Proud of my havien once again
@toddcook2016
@toddcook2016 3 жыл бұрын
nice job chuck
@ChuckBarron
@ChuckBarron 3 жыл бұрын
Thanks 👍
@traderpete007
@traderpete007 3 жыл бұрын
Seems more like a car mechanic on a compact car vs plumbing & heating.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
true that.
@jeffreybear7067
@jeffreybear7067 3 жыл бұрын
CB 1 love your videos!. Have a ? We bought a outdoor Rinnai tankless hot water heater. We live in Montana where it can get down to -20 or more with wind chill. Is there a way you can install these outside with cold temps. Like this. It’s hard to find a good plumber here and I know you know your stuff thank you .
@throttlebottle5906
@throttlebottle5906 3 жыл бұрын
I would never put an outdoor unit where average winter temps and the 100 years low would go below freezing. one long power outage and it's history ;)
@ChuckBarron
@ChuckBarron 3 жыл бұрын
actually we have a housing project that built diamond plated insulated units to house a bank of naviens to prevent freezing.
@ptech88
@ptech88 10 ай бұрын
I have replaced many of of these. They suck to replace. I am at the point now where i remove the boiler from the wall and replace the three way then reinstall it on the wall. It is much easier access
@watomb
@watomb 6 ай бұрын
Older model but that error drove me crazy. It would work most of the time. But every so often give that error. Although replacement parts where free
@johnadams2630
@johnadams2630 3 жыл бұрын
Brave soul!! I’ve been pro Navien for about 5 years. I haven’t had any issues with proper maintenance of flushing the unit. Well designed but costly. I wish they had a parts kit at our local vendors. They don’t give them away even with proper training. That’s the only downfall I have found with this Roles Royce
@ChuckBarron
@ChuckBarron 3 жыл бұрын
Thanks for sharing
@greekmaster1001
@greekmaster1001 2 жыл бұрын
I've seen alot of complaints on the naviens and I mean ALOT of issues especially the ncb models
@se032131
@se032131 3 жыл бұрын
Take a look at mikey pipes on youtube about navien heat exchange issues. I saw some indicators in your videos too.
@brewmule6799
@brewmule6799 3 жыл бұрын
Bloody knuckles and Chuck hearing her suck all the air!!! Be good to Daddy! Lol
@jorgeub27
@jorgeub27 3 жыл бұрын
If you dont mind me asking. What are the symptoms what is the reason you are changing it?
@J-Colt
@J-Colt 3 жыл бұрын
It is a piston valve and probably stuck in partially open position.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
no hot water was this system. Dr. Tech support sent me in right direction.
@RES_Plumbing-Drain
@RES_Plumbing-Drain 3 жыл бұрын
I had exact same error code and symptoms on brand new unit, then it started to work normally, go figure. How fast can you get spare parts for Navien? readily available?
@jasonyeager9102
@jasonyeager9102 3 жыл бұрын
If you are or have Navien certified techs you can get what is essentially a large tool box that has various different pieces and parts excluding a heat exchanger.
@jasonyeager9102
@jasonyeager9102 3 жыл бұрын
However, if the system is still under warranty they don’t like you just changing parts; typically we get them next day from Navien
@ChuckBarron
@ChuckBarron 3 жыл бұрын
we have local supply houses that handle them.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
on my hot list to do....a must. I gotta get there.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
true that jason. they are great.
@woody9052
@woody9052 3 жыл бұрын
These systems seem to be more trouble than they are worth.
@jasonyeager9102
@jasonyeager9102 3 жыл бұрын
Agreed; just the smallest thing can mess them up. And require annual maintenance. Definitely a pain to work on.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
not if serviced and install correctly. Trust me I have learned from my mistakes.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
true that.
@throttlebottle5906
@throttlebottle5906 3 жыл бұрын
if that was in my own, I'd be mad enough to cut the side of case and bend it out of the way for permanent easy valve access lol. you'll probably be about that mad at it when it fails again sooner than later too.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
so mental
@BrianBeamers
@BrianBeamers 2 жыл бұрын
I wonder what my issue with my Navien. I don’t get an error code.
@mikev.1034
@mikev.1034 3 жыл бұрын
👍👍
@ChuckBarron
@ChuckBarron 3 жыл бұрын
yes sir.
@Brad-jg9vh
@Brad-jg9vh 3 жыл бұрын
How do you buy a hoodie from Barron? Huh Chuck? :)
@ChuckBarron
@ChuckBarron 3 жыл бұрын
The boss supposed to set up store...we so busy. Its coming i just do not know when
@Brad-jg9vh
@Brad-jg9vh 3 жыл бұрын
@@ChuckBarron Thanks!
@rainmaker3700
@rainmaker3700 8 ай бұрын
Good video Chuck, but you guys make this job way to hard. I have replace dozens of these, it's not the actual spring valve that fails, it's the cheap plastic cam and motor that fails from constantly actuating when in recirc mode. You can replace the motor, cam assembly without pulling the pump and 3way valve body, its just 4 screws on the top of the valve body. You do have to remove the pump venting and piping to the exchanger and get them out of your way. Pull the motor off of the top and replace it along with the contacts and cam, plug in the new connectors. Relatively easy repair. 99% of the time, the spring valve is working fine, but you can test it by depressing it with your finger when you remove the motor assembly.
@mikedefilippis7837
@mikedefilippis7837 10 ай бұрын
Just had one of those shoot the same error code 001 and it was because of a gas leak on the top of the heat exchanger. I would shoot the code intermittently. All I do is repair These junkie units.
@throttlebottle5906
@throttlebottle5906 3 жыл бұрын
she's spitting ducks at ya, did you forget the header service valves shut? that leaves the expansion tank and rest of system isolated with no where for water to expand when it fired. that would rapidly expand and skyrocket the water pressure inside the boiler making it spit ducks out the relief. either always open the service valves first or better yet shut the gas supply off, power it up and purge the air out, run domestic hot water so it diverts and purges the heat exchanger also. probably have to go through a couple lockout/reset cycles, then open all valves, turn gas on and reset for the last time.
@throttlebottle5906
@throttlebottle5906 3 жыл бұрын
actually, they may have some sort of service menu with purge function. then again over engineered cruft.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
a real duzzy
@ChuckBarron
@ChuckBarron 3 жыл бұрын
mental job right here.
@mfplumbing9341
@mfplumbing9341 3 жыл бұрын
open pressure releif valve when filling maybe sounds like air
@brewmule6799
@brewmule6799 3 жыл бұрын
Nooooooooooooo!!!!
@mfplumbing9341
@mfplumbing9341 3 жыл бұрын
@@brewmule6799 fresh mule brewed beer maybe
@brewmule6799
@brewmule6799 3 жыл бұрын
@@mfplumbing9341 maybe Lol 😂
@ChuckBarron
@ChuckBarron 3 жыл бұрын
oh no...dont do it.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
stop in the name of navien.
@jasonyeager9102
@jasonyeager9102 3 жыл бұрын
Lots and lots of small screws in all those Naviens
@ChuckBarron
@ChuckBarron 3 жыл бұрын
yes sir
@jamescordes8673
@jamescordes8673 3 жыл бұрын
Please people. Don’t get Navien’s. They suck and even suck more to work on. Also avoid getting combi units of any kind. Those 3 way valves always go. Get a nice burnham alpine.
@ChuckBarron
@ChuckBarron 3 жыл бұрын
I love me some naviens but ok.
@jamescordes8673
@jamescordes8673 3 жыл бұрын
@@ChuckBarron just bad experiences lol. We had one summer half of our installs were Navien warranted swap outs. So many leaking heat exchangers. Navien tried to blame the water but we have customers on everything imaginable. One guy even has city water with a UV system. And their customer support is either really good or really bad. Had one time a relief valve was blowing cause whenever it switched to hot water the heating side pressure would increase and blow the relief valve. Their customer support recommended replacing the pressure sensor....I tried explaining to them I had a mechanical safety going off and the sensor is working cause it’s at 29 and won’t go higher because of that valve and he didn’t seem to understand and hung up on me.
@keithbrueton
@keithbrueton 3 жыл бұрын
No safe Isolation CB just get in there
@ChuckBarron
@ChuckBarron 3 жыл бұрын
a knuckle buster.
@JamesBrown-db9pk
@JamesBrown-db9pk 3 жыл бұрын
put the gloves on 1st then play with the hot stuff
@ChuckBarron
@ChuckBarron 3 жыл бұрын
ouch,
@keithbrueton
@keithbrueton 3 жыл бұрын
8.12 LOL CB
@ChuckBarron
@ChuckBarron 3 жыл бұрын
what up brother. lets do a live 5 am....i know your up then...ha
@JamesBrown-db9pk
@JamesBrown-db9pk 3 жыл бұрын
thats y me and lav dont sell that crap
@ChuckBarron
@ChuckBarron 3 жыл бұрын
James give me your cell.....lets chat brother....email me....barron9650@gmail.com
@suckamc3232
@suckamc3232 3 жыл бұрын
Have done a couple 3 way replacements not fun they need to make easier moving board, circ just to get to it
@ChuckBarron
@ChuckBarron 3 жыл бұрын
a side door be great....lol
@suckamc3232
@suckamc3232 3 жыл бұрын
@@ChuckBarron lol yeah there’s a idea
Navien 3-Way Valve Replacement NCB-240
16:04
jeffceo
Рет қаралды 446
NAVIEN  COMBI BOILER CIRCULATOR PUMP REPLACED
28:51
Chuck Barron
Рет қаралды 17 М.
VAMPIRE DESTROYED GIRL???? 😱
00:56
INO
Рет қаралды 7 МЛН
Fake watermelon by Secret Vlog
00:16
Secret Vlog
Рет қаралды 16 МЛН
НАШЛА ДЕНЬГИ🙀@VERONIKAborsch
00:38
МишАня
Рет қаралды 2,7 МЛН
Navien NCB-240 Combi Boiler 3 way Valve Replacement
13:24
Michigan Heating Guy
Рет қаралды 55 М.
Navien NCB 240 Water Heater Annual Cleaning - Water Heaters Now
16:14
Water Heaters Now
Рет қаралды 96 М.
NAVIEN NCB H Combi Boiler Level1 Introduction
19:41
Eklof
Рет қаралды 13 М.
Navien NPE 240-A Check Valve Replace
15:09
Back Patio Handyman
Рет қаралды 43 М.
Changing a Navien water sensor valve
18:43
That Tankless Guy
Рет қаралды 3,3 М.
NAVEIN COMBI BOILER NCB 240 ERROR CODE E001 PLUMBING REPAIRS
28:51
Chuck Barron
Рет қаралды 28 М.
Navien 3 Way Valve
8:10
Mechanical Hub
Рет қаралды 22 М.
4 MISTAKES Everyone Makes When Using COMPRESSION FITTINGS
10:49
plumberparts
Рет қаралды 782 М.
3 most Frequent problems for Navien combination boiler re-do
13:34
Shield University
Рет қаралды 33 М.
VAMPIRE DESTROYED GIRL???? 😱
00:56
INO
Рет қаралды 7 МЛН