Polarity Matters, Even with 24 Volts! How to Install Automatic Water Feeder on Steam Boiler

  Рет қаралды 15,720

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

Күн бұрын

Пікірлер: 48
@scottvolage1752
@scottvolage1752 Жыл бұрын
The dead men would not be happy with that installation. Remember Peter the solder flows to the heat of the flame. Good Job Mikey Pipes and Peter Piper. Make the trades great again.
@Britishhandymannj
@Britishhandymannj Жыл бұрын
Im a handyman ... i watch you everyday! Although i would never do any work outside my trade (like messing with gas or hvac i would leave that to people that do that for a living) im in NJ and woke up this morning freezing with no heat (steam boiler) because of you & your videos i was able to get heat back on quickly within 15 mins and hell i kinda looked like i knew what i was doing! So ty mikey
@PipeDoctor
@PipeDoctor Жыл бұрын
Awesome!!!
@TomHolcombe-fh1kv
@TomHolcombe-fh1kv Жыл бұрын
Yes, the old Hartford loop is important
@PipeDoctor
@PipeDoctor Жыл бұрын
Absolutely it is
@Rainmaker88
@Rainmaker88 Жыл бұрын
Hartford loop is overrated imo it saves you maybe one or two cycles of the boiler. People don’t look at their boiler at best for a week or two.
@PipeDoctor
@PipeDoctor Жыл бұрын
i hope you don't service steam systems@@Rainmaker88
@Rainmaker88
@Rainmaker88 Жыл бұрын
You have a hole in the wet return. The return drains but the boiler still has water it fires sending steam to the radiators turns to water and leaks out the wet return. Now the water is below the lowest allowable water level. The Hartford loop saved you one heating cycle. It’s almost useless.
@LaGuera187
@LaGuera187 Жыл бұрын
Great job teaching peter. i feel like he will get it eventually.
@mr.mr.4356
@mr.mr.4356 Жыл бұрын
Do you need to have an electronic low water cutoff to have the automatic water feed? I have an old style water cutoff valve.
@EduardoBurgosOnRecess
@EduardoBurgosOnRecess Жыл бұрын
Im live in Boston MA and the boiler for one of my tenants apt doesn't have an automatic water feeder, im an HVAC tech i mainly dont work on boilers so i was not sure how to do it, he has the same boiler you used in this video and some of your other video and i think im able to do the install for him now. Thank You
@concernedpersons1995
@concernedpersons1995 2 ай бұрын
It is what it is? That loop gives sense of security that the boiler won’t demolish that house. Not saying it still can’t if it has the loop installed but there’s a reason the insurance company is the one that designed that loop..
@johnwalker890
@johnwalker890 Жыл бұрын
Good job Mike and Peter.
@whodat1473
@whodat1473 Жыл бұрын
great video, but why would you leave that compression union in?
@eddwinnas
@eddwinnas Жыл бұрын
Thanks Mikey getting me through HVac school here in Worcester ma
@williamserver4332
@williamserver4332 Жыл бұрын
This was great video. Now I know how the auto feeder works. Thanks
@PipeDoctor
@PipeDoctor Жыл бұрын
Glad to help
@damionfritz5881
@damionfritz5881 10 ай бұрын
You do a great video and help the apprentice along..he is such a humble guy. Thanks for the information on the low water feeder..had a coworker install one of those same ones you had and he said it did feed water when he first installed it but then it wont feed after that. So i think he probably forgot to set the dip switches or connect the wires with the right polarity. I will have him check those this weekend...tha ks again for the great information...i was cracking up about the Bill Clinton stuff...you make the work environment less stressful when you make jokes and laugh.😅😅
@howardchan6167
@howardchan6167 Ай бұрын
I am getting conflicting information regarding where should the water feed come from? Should it be hot or cold water from the water heater? My weil mclain boiler eg manual says don't introduce cold water into a hot boiler. However, I was told I should not feed the auto feeder with hot water. Right now hot water from my water heater is feeding my boiler.
@asilj.6598
@asilj.6598 11 ай бұрын
Should everyone have there feeder set to 2 minutes and the feed amount to LWCO ? I moved into my new house and I’m assuming the previous owners has it set to 4 minutes and 1 gallon I’m not sure if i should change it or not
@rickc9873
@rickc9873 Жыл бұрын
Please explain, whether your using the auto fed or manual feed aren’t you using the same amount of water ?
@celmol.j282
@celmol.j282 11 ай бұрын
Why is the low water cut off upside down?
@luarzidnerser7467
@luarzidnerser7467 11 ай бұрын
Hi Mr Mike pipes I have one question why is not a RPZ in the supply line?
@PipeDoctor
@PipeDoctor 11 ай бұрын
Reduced Pressure Zone?
@luarzidnerser7467
@luarzidnerser7467 11 ай бұрын
A backflow preventer
@ChadNJ
@ChadNJ Жыл бұрын
Why do you not recommend an automatic water feeder? Thanks for another great video Mike!
@PipeDoctor
@PipeDoctor Жыл бұрын
They like to fail while filling. Trust me.
@ChadNJ
@ChadNJ Жыл бұрын
@@PipeDoctor Thanks for the reply. I'm getting a new steam boiler installed in the next few weeks and they included an automatic feeder on the quote. I'll absolutely discuss this with them!
@Keith_Mikell
@Keith_Mikell Жыл бұрын
Congrats on 150k. Lets have a party! Man that installl though. If i were you id be feeling the same way about it. I dont understand how these people can come in and do this to other living breathing thriving people. We are not objects that hand out money, but some "home services" treat the customer like that. Im glad you have great CS.
@spykillergames8402
@spykillergames8402 Жыл бұрын
im amazed that a voiler built in 2008 or there abouts has a standing pilot to worry about and not a spark plug ignitor
@howze2ID
@howze2ID 5 ай бұрын
I'm not a boiler guy and even I know about the equalizer and Hartford loop. That installation guy doesn't know Dan Holohan
@josecamacho191
@josecamacho191 10 ай бұрын
One thing you will never see is another provider saying the last guy did a good job.. just had this same scenario with my windshield on my car.. after he was done installing it he tells me it’s better than the last guy who installed it.. 😂😂😂 mind I never had any issues with the windshield aside from when it cracked from a rock on the road.
@PipeDoctor
@PipeDoctor 10 ай бұрын
Actually, Jose, I totally disagree with your comment. A professional will never badmouth another professional facts. I have seen disasters, and I have seen complete shit shows and I very very rarely talk negatively about another contractor on the work that they did.
@davidlampe4153
@davidlampe4153 Жыл бұрын
Time for Peter to watch heating help on KZbin there’s some videos on steam heating old presentation’s by Dan Holohan about steam boiler piping and it might be helpful if Peter watched them once a year to review what the meaning of the dead men’s lessons are. I have to wonder if that boiler was in a pit before it was replaced with a gas boiler. The main seems very low in your video. The previous contractor has not read much about near boiler piping otherwise he wouldn’t have made so many mistakes. No equalizer, no drop header, no drip leg on the relief valve!
@StevenS-b5k
@StevenS-b5k Жыл бұрын
Peter that was a nasty Solder!! 😣😣
@scottmaz4063
@scottmaz4063 Жыл бұрын
#1🎉
@ThejasonJaw5442
@ThejasonJaw5442 Жыл бұрын
Mickey pipes
@scottmaz4063
@scottmaz4063 Жыл бұрын
Petro I worked for them. Thank God I left.
@instrumenttech4220
@instrumenttech4220 Жыл бұрын
For the love 💕 of all that’s a torch ge that poor kid as new tip that’s one messed up torch
@scottmaz4063
@scottmaz4063 Жыл бұрын
I bet the equalizer was there but the hoopal who installed the new boiler took it out. Because he was an idiot and did job for $1,500. You get what you pay for.
@PipeDoctor
@PipeDoctor Жыл бұрын
Probably
@PlumbThumbs
@PlumbThumbs Жыл бұрын
🤙🏾🤙🏾🤙🏾
@stevestadterman9270
@stevestadterman9270 Жыл бұрын
wowsers,,i guess peter sucks at soldering...
@RussTripi
@RussTripi Жыл бұрын
Bushings PLEASE
@PipeDoctor
@PipeDoctor Жыл бұрын
Yeah
How to Fix Dunkirk Steam Boiler Banging & Air Valves Leaking Water - Bad Pressuretrol Replaced
40:52
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 34 М.
#behindthescenes @CrissaJackson
0:11
Happy Kelli
Рет қаралды 27 МЛН
Every team from the Bracket Buster! Who ya got? 😏
0:53
FailArmy Shorts
Рет қаралды 13 МЛН
Rebuilding a McDonnell No. 67 low-water cut-off valve for a steam boiler
15:58
Checking Out A Used VXT-24 Steam Boiler Water Feeder
9:38
Silent Steam Team
Рет қаралды 1 М.
Low Water Cut Offs & Water Feeders (Steam Boilers)
10:46
Jersey Mike HVAC
Рет қаралды 21 М.
No Heat Williamson Gas Boiler Service Call by Mike Diack - Fake LWCO Exposed!
26:18
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 19 М.
Steam Boiler Conversion to Hydronic Hot Water Heating - Step by Step Retrofit Video
41:29
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 8 М.
Can we DIY ultra efficient UFH with a heat pump?
44:40
FloweringElbow
Рет қаралды 192 М.
Steam Boiler Heating Basics to Save You Money! Tips for the Homeowner and Advice for Professionals
23:05
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 30 М.
Steam Boiler Banging/ Hammering Noises Leaky Air Vent
27:22
The HVAC Hacker
Рет қаралды 47 М.