Pump Head Calculation - HVAC Chilled Water System.

  Рет қаралды 120,980

HVAC SIMPLIFIED

HVAC SIMPLIFIED

Күн бұрын

Pump Head Calculation - HVAC Chilled Water System.
Download Links
Chilled Water Pipe Sizing and Design Calculation:
• Chilled Water Pipe Des...
How to calculate GPM for FCU & AHU
• How to calculate GPM f...
HVAC System - Primary & Secondary Pumping Methods - 4 Major
• HVAC Chilled Water Pum...
Please support HVAC SIMPLIFIED for more videos like this !
/ amkhvacsimplified

Пікірлер: 271
@shailpatel4018
@shailpatel4018 5 жыл бұрын
I love you man. You are awesome. You are a very good explainer. It helped me a lot. Not just this video all other also as good as this one. I enjoyed it a lot.
@hvacsimplified
@hvacsimplified 5 жыл бұрын
Thank you Sahil, good to know that the effort is helpful.
@wildlifechannel7989
@wildlifechannel7989 4 жыл бұрын
@@hvacsimplified sir same please send me excle sheet head loose calculation
@Shekhar_S_Singh
@Shekhar_S_Singh 6 жыл бұрын
Bahut kam time me , bahut point ki baat btatae hai aap, kafi achchhi jankari hai , thank u so much,😊
@hvacsimplified
@hvacsimplified 6 жыл бұрын
Thank you Shekhar, I am glad to be of any kind of help to you all.
@ImranKhan-pi2hu
@ImranKhan-pi2hu 6 жыл бұрын
Long waited topic. Thank you very much SIR. This is exactly what was missing. Hats off to you once again 😚😚
@itsadil9469
@itsadil9469 5 жыл бұрын
Dear , Really appreciated. The way ypu explained is superb.
@hvacsimplified
@hvacsimplified 5 жыл бұрын
Thank you
@itsadil9469
@itsadil9469 5 жыл бұрын
@@hvacsimplified Could you also upload ESP calculation and sheets related to it
@narendravaddepalli3677
@narendravaddepalli3677 5 жыл бұрын
Really appreciate all your Hard work...for explaining
@mohammedadnan8841
@mohammedadnan8841 4 жыл бұрын
Appreciate your work this will helpful to many people. I have 3 questions 1.Please make us understand the range of primary pump and secondary pump the consideration range for the head. 2.please explain about cooling tower pump head calculation. 3.please explain how should we consider horizontal and secondary pump head should we consider it to be same. Fyi
@mdzakaurrahman798
@mdzakaurrahman798 10 ай бұрын
Thank you very much, Sir. You explain very well.
@mohammednujed6201
@mohammednujed6201 4 жыл бұрын
Alhamduilliha it is a very useful and important topic i get revised with this video thanks a lot.May Allah swt bless u for helping us thanks once again. Please share the excel sheet in the description or in thr reply of this comment
@iftekharajmal7945
@iftekharajmal7945 6 жыл бұрын
EXCELLENT VIDEO , LOAD CALCULATION DUCTING & PIPING EXCEL SHEET REQUIRED
@sudhi1013
@sudhi1013 2 жыл бұрын
Good Explanation
@DoraDotz
@DoraDotz 2 жыл бұрын
Like 1.6k Have a good day to u my friend. Thanks for sharing this wonderful video
@hvacsimplified
@hvacsimplified 2 жыл бұрын
Welcome
@KMA835
@KMA835 6 жыл бұрын
Sir please add excel sheet in the description
@shannn787
@shannn787 3 жыл бұрын
thank you ... great ved Q . is there any friction loss difference in Horizontal and vertical pipe ?
@kaysherahammed1975
@kaysherahammed1975 3 жыл бұрын
Nice work
@shailendramulgaonkar2980
@shailendramulgaonkar2980 4 жыл бұрын
very good video, nicely explained. Great man. God bless you . share more videos on design of stair case pressurization system & Smoke extract design . Car park ventilation video
@hvacsimplified
@hvacsimplified 4 жыл бұрын
sure will do it.
@shahbaz__
@shahbaz__ Жыл бұрын
Thank you for making such an informative video. Sir, the longest length is considered for calculation of the pump head, but there will be head loss through AHU's coil which are connected before the last AHU. Why we aren't considering the head loss of AHUs?
@Ranjeet-hj7bc
@Ranjeet-hj7bc 6 жыл бұрын
Very useful videos you are uploaded...thnx Sir
@hvacsimplified
@hvacsimplified 6 жыл бұрын
Thank you Jeet
@ruicabritas7595
@ruicabritas7595 3 жыл бұрын
very nice video. one question only to calculate head pump when we calculate to user, do we do x2 for the return piping? or only to the unit?
@mohdzohair3669
@mohdzohair3669 2 ай бұрын
It's really good
@abdelfatahnewishy2570
@abdelfatahnewishy2570 4 жыл бұрын
Thanks for your explanation for Pump Head Calculation. please sir can we get this excel sheet?
@farhansheikh6589
@farhansheikh6589 3 жыл бұрын
Great job
@farhansheikh6589
@farhansheikh6589 3 жыл бұрын
Can u please send me this excel sheet
@jajatisendh4622
@jajatisendh4622 4 жыл бұрын
In a Closed System, I believe only Supply to the Last (Critical) Unit needs to be considered, not the Return Piping. Because If you can Supply to the Unit, the Return will automatically come to the Pump. IS it Correct? But I must say, your video quality is very good with good understanding of the subject.
@a2z2m3eb
@a2z2m3eb 2 жыл бұрын
Hi, by any chance u have the answer for this?
@khaleelahmedshaik7857
@khaleelahmedshaik7857 9 ай бұрын
Good brief description but 2 things need clarification 1. U didn't mentioned about how to take pressure loss of valves..it is not same like fittings, u have to know kv value of valves first 2. For F&R pipes did u taken the length of F&R both pipes
@prasadgurav7917
@prasadgurav7917 Жыл бұрын
nice video sir ji,... please clear my doubt pump head calculation is different head ht =hs+hd+(pressure receiving-- pressure reservoir) when we use this formulae ?or head loss calculation is diiferent right ? pump head loss helps to determined what capacity of motor (hp) required for pump.
@shamsheralam8862
@shamsheralam8862 4 жыл бұрын
Thanks sir..very informative vedioes..kindly make more vedioes on HVAC...TESTING AND COMMISSIONING.
@Fazal465
@Fazal465 4 жыл бұрын
Excellent
@Premkumark90
@Premkumark90 2 жыл бұрын
Sir,if the pipe is in vertical position then head = total length of pipe,but what is the pipe head for horizontal laying pipe?
@hvacsimplified
@hvacsimplified 2 жыл бұрын
In the chilled Water Pipe system the system is a closed loop therefore there is no difference if the Pipe is vertical or Horizontal.
@sheshnathprasad7547
@sheshnathprasad7547 4 жыл бұрын
Dear Sir, Kindly upload your pump head calculation sheet by which we can download.
@sameerfarooq2446
@sameerfarooq2446 6 ай бұрын
Dear sir ek Video VRV system pe bana dijiye full explanation ke saath jisme Louvers,grill, exhaust, return Ducting,ye sari chijen ho.
@anwarmokhtar5925
@anwarmokhtar5925 11 ай бұрын
Air cooled chiller ka pump selection bhi bta dijye.. Meharbani hoga apka..
@shubhamsingh-ck3cg
@shubhamsingh-ck3cg 5 жыл бұрын
its beneficial for me thanks sir
@rid3r5
@rid3r5 3 жыл бұрын
I have watched this video a couple times to try understand it properly, i do have one question though, when selecting the Head Loss to dimension the pump, knowing how many l/s or GPM, you account for pressure loss in the piping and fittings to the furthest point of your piping, yes? and not all of them combined, imagine theres a valve in bedroom with FCU 4, and it has a drop pressure of 0.3 and the equipment drop pressure also 0.3, you add them in your equation to head calculation but only one of them, and not all FCU combined, right? Sorry if its a dumb question :p
@hvacsimplified
@hvacsimplified 3 жыл бұрын
Yes. When calculating the Pump Head the farthest length along with it fitting to be calculated one more thing the designer/Engineer need to see the critical path also. Because sometime instead of the longest length there might be another route which might be shorter in length but have more fittings of pressure drop.
@rid3r5
@rid3r5 3 жыл бұрын
@@hvacsimplified Thanks a lot for your explanation and tip in such short notice, it does make sense, any chance your available to help me dimension a system? it is a circuit with primary and secondary pumps and inertia tank, the pumps with your video for pressure drops and head loss, also the pipe selection that is all ok, but for inertia tank & buffer, i have no idea what are the dimension criteria, if the tank is pressurized etc, i would be very gratefull, thanks
@AtifKhan-lc8xp
@AtifKhan-lc8xp 6 жыл бұрын
So nice ,please tell me why we have installed motorized or 2 way valve in return line.
@sreejithr.g.8151
@sreejithr.g.8151 4 жыл бұрын
explained very well!!can u plz do a video about chilled water flushing process,make up water,draining etc??
@folk6579
@folk6579 3 жыл бұрын
love you
@azeezali2028
@azeezali2028 4 жыл бұрын
Excellent sir Can u please explain the tee branch and tee run how to take this values.
@wasimchouhan6638
@wasimchouhan6638 6 жыл бұрын
Thank you soo much sir this video help us alot.
@3xambuj
@3xambuj 5 жыл бұрын
Thanks for this education
@hvacsimplified
@hvacsimplified 5 жыл бұрын
Pleasure, always knowing it is helpful
@MrAbdullah09
@MrAbdullah09 5 жыл бұрын
Hi. Could you share the exel sheet and the table from where you took the Loss values in feet? thanks
@thushanmk3781
@thushanmk3781 2 жыл бұрын
Hi , Thanks for the video , please share the pipe fittings pressure loss chart and source of it. thanks
@taktakmelek7556
@taktakmelek7556 5 жыл бұрын
So the Primary pump should overcome pressure losses of the chiller loop only: from the suction point, through the chillers, to the suction point of the secondary pump. So it will have always less Head than the secondary pump that should handle the pressure losses throughout the supply and return of all the distribution loop ??
@farhansheikh6589
@farhansheikh6589 10 ай бұрын
From where did you get 2.3 ft/ 100ft head
@dilshadfiretech6990
@dilshadfiretech6990 6 жыл бұрын
thanks for vedios . sir chilled water pipe sizing me friction loss kaise find out karte h?
@shaikzakeer8146
@shaikzakeer8146 Жыл бұрын
bhai, mere ek doubt hai HP jo nikal rehe hain wo ek pump hai , in case 3 pumps hai primary side mai tho apan jab calculate kar rahain hai wo ek pump hai na bhai , ab wo head loss jo aya hai usko apan HP ke formulea mai use karne baad jo HP arahai wo single pump hai na bhai.
@mohanroi6456
@mohanroi6456 6 жыл бұрын
really usefull
@abdullaghare1488
@abdullaghare1488 4 жыл бұрын
I have one question- to calculate head in vertical pipe we have fo use same method or simply we have to take vertical lenght+friction loss
@vinitkadam8951
@vinitkadam8951 4 жыл бұрын
You have missed the NPSH concept here, try to cover that because it is equally important.
@shristishakya5916
@shristishakya5916 3 жыл бұрын
Please explain Sir; how do you do head calculation for the multi-pump's chillers system, here in your this lecturer not clear, head loss and GPM can be divided to select pumps to match demand flow?
@gramathara4907
@gramathara4907 2 жыл бұрын
Is same pressure drops for horizondal straight pipe and vertical straight pipe
@hvacsimplified
@hvacsimplified 2 жыл бұрын
In the closed loop system. Yes
@deepanshusharma2046
@deepanshusharma2046 3 жыл бұрын
If we are connecting secondary pump in parallel connection, then its pump head has to be same. You cant divide the total head with number of pumps.
@faizankhan-bo7sl
@faizankhan-bo7sl 6 жыл бұрын
Very nice video sir ...thanx
@hvacsimplified
@hvacsimplified 6 жыл бұрын
Welcome Faizan
@iamnobody3464
@iamnobody3464 4 жыл бұрын
Can you please make a video on chiller valve Mock up.
@SuperRancell
@SuperRancell 4 жыл бұрын
hI....How evalute the energy flow at Primary Circuit (inposted by the primary pumps) for consider it on the desing HEAD at the secadary circuiT???
@paurushgargtube
@paurushgargtube 5 жыл бұрын
Thanks
@tariqueanjum8365
@tariqueanjum8365 6 жыл бұрын
Weldone sir.
@hvacsimplified
@hvacsimplified 6 жыл бұрын
Thanks Anujm.
@AmitJha-gp9mb
@AmitJha-gp9mb 5 жыл бұрын
HVAC Simplified Online Training - By AMK sir can you provide excel sheet Amitjhasky@gmail.com
@khanalam123
@khanalam123 6 жыл бұрын
Please tell me I have an issue regarding reciprocation compressor failure of Air cooled chiller(240 ton). frequently valve reed are breaking. what its reason and solution
@sakdasaosa9746
@sakdasaosa9746 3 жыл бұрын
Do you have Method for Chill water cleaning and flush line? Can I have this method.
@ral153
@ral153 5 жыл бұрын
Hi Sir, Do You have English Version for this one?
@mr.x5851
@mr.x5851 5 жыл бұрын
Thank bro
@MDARMAN-xx1jm
@MDARMAN-xx1jm 6 жыл бұрын
So nice
@zafarchaudhary9093
@zafarchaudhary9093 6 жыл бұрын
MD ARMAN SB can u give me ur contact no.
@MEP.ENGINEERING.WORKS92
@MEP.ENGINEERING.WORKS92 Жыл бұрын
Good Shai friend
@MindspaceEducation
@MindspaceEducation 6 жыл бұрын
pls add ASHRAE Chart SECHEDULE 40 PIPE
@mohammedshahbaz8861
@mohammedshahbaz8861 6 жыл бұрын
Thank u sooo muchhh
@gulfamazam6381
@gulfamazam6381 6 жыл бұрын
Hi sir. Great work. I have confusion . I agree with you for division of flow sir but head will not be divided in case of more than one pump acting as schwps
@hvacsimplified
@hvacsimplified 6 жыл бұрын
Hi Azam, Primary and Secondary Pumps are two different. Can you explain in detail about where we did not understood. So we can understand each other. 😊
@gulfamazam6381
@gulfamazam6381 6 жыл бұрын
Am on job but will inform you sir the exact time of video.
@babugd1
@babugd1 4 жыл бұрын
dear sir i have a doubt that,at the condition when both primary and secondary pumps are involved, some of the other tutorials, for primary pumps people are taking whole pipes from the units to the chiller and for secondary pumps all the pipes from the chiller to units..is that method is feasible? and do we need to take the static height also?
@hvacsimplified
@hvacsimplified 4 жыл бұрын
The terminalogy Primary means the pipes related to Chiller's only. Secondary can be in various type, such as from the chiller to the building or from the chiller to the building secondary and saperate for the building as tertiary
@babugd1
@babugd1 4 жыл бұрын
@@hvacsimplified thanks for your reply.. if the chiller pumps at the ground floor, and chiller at higher level,do we need to consider the static height also?..If possible can you send me the excel sheets to my email babugd@gmail.com
@jitendratalole9925
@jitendratalole9925 2 жыл бұрын
very good sir .....kindly share the head calculation excel sheet
@krishnaprasanth5679
@krishnaprasanth5679 5 жыл бұрын
Please explain condensor pump calculation
@upendrarauta3749
@upendrarauta3749 5 жыл бұрын
Sir pump nameplate me jo discharge &head actual meaning kya hota hai
@mubashircm9803
@mubashircm9803 4 жыл бұрын
how to calculate reducers
@nabiltariq7349
@nabiltariq7349 5 жыл бұрын
what is differnece between tee line & tee branch
@afaqueshaikh2013
@afaqueshaikh2013 3 жыл бұрын
Sir how to calculate GPM in airwasher
@souravpatali8065
@souravpatali8065 5 жыл бұрын
Excellent video sir .Thank u so much sir pls send me this excel sheet .which is help to me learn deeply this topic.👍
@salmankhanmohmand9174
@salmankhanmohmand9174 5 ай бұрын
gpm and chilled water pump videos ke link uper right corner me put karna chaye
@muhammednawfal2791
@muhammednawfal2791 4 жыл бұрын
thank you soo much for detailed explanation , sir can you please share Pump head calculation excel sheet,
@MuhammadAsif-np7pi
@MuhammadAsif-np7pi 6 жыл бұрын
stunning and amazing sir,kindly share excel sheet for practice and learning
@8836293
@8836293 2 жыл бұрын
Nice explanation can we get the excel sheets if possible...
@hvacsimplified
@hvacsimplified 2 жыл бұрын
Sheet I'd available on www.hvacsimplified.in
@shahbazshaikh4609
@shahbazshaikh4609 3 жыл бұрын
Can you share this spreadsheet
@vijaydhutale8054
@vijaydhutale8054 5 жыл бұрын
how to get this excel sheet. please advise...
@zafarchaudhary9093
@zafarchaudhary9093 6 жыл бұрын
Sir..Plzz tell me about marine HVAC system.
@syedanwar6459
@syedanwar6459 6 жыл бұрын
Please share the link of carrier pipe fittings data, Thanks
@upendrarauta3749
@upendrarauta3749 5 жыл бұрын
Sir, pump ka discharge and flow practical meaning kya hota hai
@upendrarauta3749
@upendrarauta3749 5 жыл бұрын
Matlap kitna height pe kitna flow rate hoga
@rashidiqubal2991
@rashidiqubal2991 6 жыл бұрын
Sir plz make a video on AHU manifold drawing...
@siddhartgamer7661
@siddhartgamer7661 6 жыл бұрын
Sir please explain Expansion tank sizing calculation
@izamnahal8746
@izamnahal8746 6 жыл бұрын
Sir while considering head, Is it necessary to consider to which height pump have to pump water in case of closed loop, as in your AutoCAD drawing pipe got risers ? I understood pipe fitting loss and loss per square feet, what about height difference sir? And from where to get losses due stariner, drv and all? Thank you
@hvacsimplified
@hvacsimplified 6 жыл бұрын
The head is to be considered till the last FCU or AHU. now you need to first understand the type of pumping such as Primary and Secondary Pumps.
@khattakjani5663
@khattakjani5663 6 жыл бұрын
Sir plz make a video about BUT meter
@ammarkarim5638
@ammarkarim5638 3 жыл бұрын
Sir, at 8:24, how we want to estimate the GPM?
@sirajdeen260
@sirajdeen260 6 жыл бұрын
Kindly upload video for pump head calculation and hp in english
@dilipkumarsudikonda4720
@dilipkumarsudikonda4720 3 жыл бұрын
why u cant upload excel sheet ? plz mention link
@MindspaceEducation
@MindspaceEducation 6 жыл бұрын
pls add excel sheet for pump head calculation
@mohamedziaudeen3719
@mohamedziaudeen3719 5 жыл бұрын
pls provide me the arrier pipe fitting pressure loss table
@raviteja7921
@raviteja7921 6 жыл бұрын
sir thnq for helpful information ,please kindly mention the Excel sheet link
@mannraj4867
@mannraj4867 2 жыл бұрын
Hi Sir, can i have pump head calculation excel file, please share, thanks
@hvacsimplified
@hvacsimplified 2 жыл бұрын
Download it available on www.hvacsimplified.in
@ahamadshaikh3535
@ahamadshaikh3535 6 жыл бұрын
Sir makeup tank & infection tank how to select please
@hvacsimplified
@hvacsimplified 6 жыл бұрын
Sure
@zuhairpm3143
@zuhairpm3143 5 жыл бұрын
@@hvacsimplified Please send excel sheet in zuhairpadattil@gmail.com
@praveentp9936
@praveentp9936 5 жыл бұрын
Sir please add XL sheet in description
@rameezpansari6473
@rameezpansari6473 4 жыл бұрын
Sir PDF available nhi hai
@primehvac-lavkoshchavhan2788
@primehvac-lavkoshchavhan2788 5 жыл бұрын
sir where we can get the chart
@tariqueanjum8365
@tariqueanjum8365 6 жыл бұрын
Sir ek video cooling tower ke liye Kaise gpm find out karte hai.tonnage Kaise Malum chalega kya formula hai.sir plz request you
@hvacsimplified
@hvacsimplified 6 жыл бұрын
Added in the list.
@tariqueanjum8365
@tariqueanjum8365 6 жыл бұрын
HVAC Simplified Online Training - By AMK Which video sir u have mention for gpm calculation for cooling tower
@hvacsimplified
@hvacsimplified 6 жыл бұрын
will prepare soon for cooling tower.
@tariqueanjum8365
@tariqueanjum8365 6 жыл бұрын
HVAC Simplified Online Training - By AMK Thanku sir
@deen_overr_dunyaa
@deen_overr_dunyaa 5 ай бұрын
Excel sheet kaise milegi bro
@joydipghosh3273
@joydipghosh3273 5 жыл бұрын
Please share the link of excel sheet sir,I got lot of suport from your channel kindly share excel sheet
@mohammed5yaz985
@mohammed5yaz985 5 жыл бұрын
asslam alikum sir DRV ka 120' kaise ayya please valve losses ka table send kariyea thanks
HVAC Chilled Water Pumps - Primary & Secondary System
15:20
HVAC SIMPLIFIED
Рет қаралды 55 М.
How to Fight a Gross Man 😡
00:19
Alan Chikin Chow
Рет қаралды 18 МЛН
Can You Find Hulk's True Love? Real vs Fake Girlfriend Challenge | Roblox 3D
00:24
Noodles Eating Challenge, So Magical! So Much Fun#Funnyfamily #Partygames #Funny
00:33
How To Choose Mac N Cheese Date Night.. 🧀
00:58
Jojo Sim
Рет қаралды 99 МЛН
VAV Variable Air Volume - HVAC system basics hvacr
13:53
The Engineering Mindset
Рет қаралды 1 МЛН
Data Center HVAC Systems
20:14
MEP Academy
Рет қаралды 137 М.
HVAC Interview Questions and Answers 2024
19:44
Shibin Eta
Рет қаралды 28 М.
How Air Handling Units work   AHU working principle hvac ventilation
13:02
The Engineering Mindset
Рет қаралды 1,2 МЛН
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,2 МЛН
Basic HVAC Controls
17:48
MEP Academy
Рет қаралды 157 М.
HVAC - Duct Detector
29:18
KEEP IT HVACING
Рет қаралды 2,6 М.
How to Fight a Gross Man 😡
00:19
Alan Chikin Chow
Рет қаралды 18 МЛН