PV18 PRO inverter communicates with multiple lithium batteries.

  Рет қаралды 7,449

Must Energy Group

Must Energy Group

Күн бұрын

#MUST #BMSsettings #lithiumbattery #inverterinstallation
This Video is about Communication of MUST Lithium Batteries with Inverter. Batteries are connected in parallel to form a storage bank then RS485 Port is used for Communication.

Пікірлер: 52
@yukuz69
@yukuz69 Сағат бұрын
In all your manuals for inverters CAN is 4,5 pins. Here you say 5,6. Where is wrong? In different versions of manuals for PV1900 6kW option 41 is 0 or 17 for the Must battery. Where is wrong? Fix your mistakes finally. And give the correspondence tables to your customers.
@torstenjaeckel5414
@torstenjaeckel5414 5 ай бұрын
Thanks a lot!
@maiyaelectrical2932
@maiyaelectrical2932 4 ай бұрын
I have 3 inverters (MUST PRO inverter 5.5kW) connected in parallel to produce 3 phase power. With that, I have 3 PV18-5248PRO connected in parallel as well to create one battaery bank. Do i configure All 3 Inverters to set parameters 14 and 41? Also, should i connect communication cable CAN to COM from 1st battery to the 1st inverter only?
@MUSTENERGY
@MUSTENERGY 4 ай бұрын
Hello, please consult our after-sales engineer to give you an accurate answer service@mustenergy.com
@crealpet972
@crealpet972 Ай бұрын
Where I can find protocols table for option 41? Protocol 0 is compatible with JKBMS CAN: in BMS app need select CAN protocol No 10. When connection established I have strange issue - invertor attempt load battery for maximum current 115A for several short impulses, may it try sold energy back to grid (but model is off-grid!).
@MUSTENERGY
@MUSTENERGY Ай бұрын
@@crealpet972 Name:Anson Liu Customer Service WHATSAPP:+86 13302843818 service@mustenergy.com
@agmkvm8005
@agmkvm8005 Ай бұрын
fully support the question. it would be much easy to simply select right protocol if we had a table of supported protocols!
@MUSTENERGY
@MUSTENERGY Ай бұрын
@@agmkvm8005 We will give feedback and improve, thank you😊
@oleksandrmelnychenko645
@oleksandrmelnychenko645 Ай бұрын
Good afternoon, tell me the settings of the Must inverter to the dyness b4850 battery. I put the ones that are in the battery manual, when the inverter has already fully charged it, it gives an error (3), "battery voltage is high", then a few minutes pass and the inverter charges the battery again and gives the error again. Why doesn't the inverter turn off charging and stop charging on the SAN bus? Should the voltage be set higher or lower? Thanks for the nice info!
@oleksandrmelnychenko645
@oleksandrmelnychenko645 Ай бұрын
Perhaps it is necessary to set the value of Li in point [14], and not to set other parameters?
@MUSTENERGY
@MUSTENERGY Ай бұрын
@@oleksandrmelnychenko645 Hello , can you send your question to our engineers and they will help answer it for you . service@mustenergy.com
@lancerl2
@lancerl2 2 ай бұрын
Hello! Could you help me? How can I connect my inverter Must PV18-5048VHM with battery DYNESS B3 LiFePO4 48V/75AH ? After installation it works, but inverter doesn't see battery and doesn't know information about it.
@MUSTENERGY
@MUSTENERGY Ай бұрын
Hello, you can consult our engineers service@mustenergy.com
@Ellfyn
@Ellfyn 6 ай бұрын
Do you have a Manuel for the pv1800 5248 pro
@tolgahannsusur2534
@tolgahannsusur2534 6 ай бұрын
For example if I have 10 x 48 volt battery connected in series, will dial 1 canbus send 480 volt to the inverter or only 48 volt?
@MUSTENERGY
@MUSTENERGY 6 ай бұрын
Sorry, this question requires an engineer to answer. Please send your inquiry to service@mustenergy.com. If you have any pictures, you can also send them together. Thank you.
@OleksandrShcherbatiuk
@OleksandrShcherbatiuk 2 ай бұрын
Why the PCB_T on the battery increased up to 100 C even on low usage level?
@MUSTENERGY
@MUSTENERGY 2 ай бұрын
You may need to consult R&D for specific details, but all batteries undergo strict safety inspections before leaving the factory.
@sbee9776
@sbee9776 Жыл бұрын
41 option set numbet pylon protocol?
@bimmer_k
@bimmer_k 11 ай бұрын
I have an invertor ph18-5248 pro version 1.16. where I can get fresh firmware and how I can update it? thanks
@MUSTENERGY
@MUSTENERGY 11 ай бұрын
Hello, where are you from? Please email me the serial number the machine was sent to, and where you purchased it. email: must.sem.2018@gmail.com
@bimmer_k
@bimmer_k 11 ай бұрын
@@MUSTENERGY I have sent the email and didn't get the answer yet
@MUSTENERGY
@MUSTENERGY 11 ай бұрын
@@bimmer_k Your email has been received, our engineers will reply to you as soon as possible.
@actiontower
@actiontower Жыл бұрын
I just bought two LP16-24100 batteries, and I want to connect them with my axitx inverter. is possible to connect them ? if not .. how can I connect the two batteries to be in sync so when I turn off master battery the other will turn off ?
@MUSTENERGY
@MUSTENERGY Жыл бұрын
Hello, this brand of inverter is not our regular matching model. Could you pls add our after sales engineer Mr. Sven and describe your problem details? email: cs-lgy@mustpower.cn
@sbee9776
@sbee9776 Жыл бұрын
is it possible to combine the inverter must ph18-5248 pro with the battery pylontech us2000c?
@MUSTENERGY
@MUSTENERGY Жыл бұрын
Could you pls add our after sales engineer Mr. Cui and describe your problem details? email: cs-cds@mustpower.cn
@hasanhomidan7644
@hasanhomidan7644 Жыл бұрын
Is there compatibility between the battery and the voltronic inverter?
@MUSTENERGY
@MUSTENERGY Жыл бұрын
yes😊
@hasanhomidan7644
@hasanhomidan7644 Жыл бұрын
I'm trying to connect them, but I'm getting an error. What are the steps for connecting the battery ?
@MUSTENERGY
@MUSTENERGY Жыл бұрын
tips: drive.google.com/file/d/1lB9MQOOE7Gybv1XAKZ3J9wBlr8DFHB05/view?usp=sharing drive.google.com/file/d/13mNY5J-RVV6ydtOXoDGbr_ug-u9aYG0O/view?usp=sharing
@shakertatari4622
@shakertatari4622 Жыл бұрын
Please I have LP16-48200 battery, and I connect it with my Voltronic inverter Axpert-KING II TWIN. and it stop charging on 98% ? can you help for that please ?
@MUSTENERGY
@MUSTENERGY Жыл бұрын
There may not be a matching BMS protocol, it depends more on the compatibility of the inverter.
@gypzyluffydanger1707
@gypzyluffydanger1707 Жыл бұрын
Plz Communication pin definitions for must pv18 5248 to must liop4 battery 48v 200Ah plz..
@MUSTENERGY
@MUSTENERGY Жыл бұрын
Hello, this video has been fully recorded
@asmelashselamawi8888
@asmelashselamawi8888 Жыл бұрын
How do we connect the comunication cable with Victron inverter?
@MUSTENERGY
@MUSTENERGY Жыл бұрын
This inverter is not manufactured by us
@asmelashselamawi8888
@asmelashselamawi8888 Жыл бұрын
@@MUSTENERGY Thank you for your replay. What type of communication cable are we using to connect batteries in parallel. Is it an ordinary RJ45 cable?
@MUSTENERGY
@MUSTENERGY Жыл бұрын
@@asmelashselamawi8888 yes
@asmelashselamawi8888
@asmelashselamawi8888 Жыл бұрын
@@MUSTENERGY Perfet! Then, how will I be able to know if all my batteries are already comunicating or not?
@asmelashselamawi8888
@asmelashselamawi8888 Жыл бұрын
I have 5.2kw inverter and the top board is damaged. Is there any possiblity to get new board from your company? And is it possible to get a contact adress email or WhatsApp?
@MUSTENERGY
@MUSTENERGY Жыл бұрын
Hello, you can email our engineer and provide the code of your machine so that we can judge whether there are spare parts. email: cs-cds@mustpower.cn
@asmelashselamawi8888
@asmelashselamawi8888 Жыл бұрын
@@MUSTENERGY Thanks!
@ahmedsaad-ph5ll
@ahmedsaad-ph5ll 8 ай бұрын
what is the number for huawei lithium battery 48v 100ah b1 that i can set on option 41
@MUSTENERGY
@MUSTENERGY 8 ай бұрын
Hello , can you send your question to our engineers and they will help answer it for you . service@mustenergy.com
@stalkerwin
@stalkerwin 10 ай бұрын
I have a MUST inverter PV 18-5248 PRO and a LiFePo4 Deye RW-M6.1 battery. Help me connect them so that the inverter can read the BMS batteries. Please tell me the cable pinout. Thank you.
@MUSTENERGY
@MUSTENERGY 10 ай бұрын
hello, If you encounter any post-sales issues, kindly send an email to our customer service engineer at service@mustenergy.com.
@LZEE-p1f
@LZEE-p1f 11 ай бұрын
must pro 5.5kw inverter + 200ah with LiFePO4 (pace bms) battery - It is ok when I chose must inverter setting LI ? (PIN ASSIGN IS CORRECT). Other INV Such as Voltronic Inv, I chose PYL , It is ok. MUST INVETER is what protocol support ? for example , Pylontech Protocol?
@MUSTENERGY
@MUSTENERGY 11 ай бұрын
Support Pylontech protocol
@wolfehone
@wolfehone 10 ай бұрын
does it work on Must PV1800 3kw?
@MUSTENERGY
@MUSTENERGY 10 ай бұрын
yes
@wolfehone
@wolfehone 10 ай бұрын
i have tried but not working, can you give me some instruction please? @@MUSTENERGY
How a Sand Battery Could Revolutionize Home Energy Storage
13:18
Undecided with Matt Ferrell
Рет қаралды 1,4 МЛН
How to Install and Parallel Lithium Batteries
16:44
Smilinsun Solar Energies
Рет қаралды 7 М.
Players vs Corner Flags 🤯
00:28
LE FOOT EN VIDÉO
Рет қаралды 65 МЛН
哈莉奎因怎么变骷髅了#小丑 #shorts
00:19
好人小丑
Рет қаралды 52 МЛН
Шок. Никокадо Авокадо похудел на 110 кг
00:44
Incredible: Teacher builds airplane to teach kids behavior! #shorts
00:32
Fabiosa Stories
Рет қаралды 10 МЛН
Techniques Paralleling LiFEPO4 Batteries together
15:50
Ian's Solar Projects
Рет қаралды 11 М.
You Are Using Lithium Battery Wrong Way: *Long Backup Trick*
3:25
Tech Powered Life
Рет қаралды 1,7 М.
DCS battery! Youtuber Sued for Reviewing this Battery?! Let's Test It!
19:44
DIY Solar Power with Will Prowse
Рет қаралды 661 М.
New! EG4 PowerPro Budget Model: 14.3kWh LiFePO4 Battery for $3,431
13:48
DIY Solar Power with Will Prowse
Рет қаралды 357 М.
EG4 LifePower4 Batteries: Exploring BMS Communications -Tech Chat
5:53
Signature Solar
Рет қаралды 42 М.
How to make parallel connection for lithium battery?
11:20
Leo @ BONJOUR SOLAR
Рет қаралды 17 М.
Is THIS the Best Solar Inverter for Nigeria?
9:28
Fisayo Fosudo
Рет қаралды 87 М.
Dyness B3 connect with parallel Luxpower hybrid inverter
6:09
Players vs Corner Flags 🤯
00:28
LE FOOT EN VIDÉO
Рет қаралды 65 МЛН