Trane Heat Pump WON'T stop Turning On/Off - COLD Weather Diagnosis

  Рет қаралды 16,893

Quality HVACR

Quality HVACR

Күн бұрын

Пікірлер: 58
@JakePorterHVAC
@JakePorterHVAC 11 күн бұрын
Your channel has been growing quick bud. Great to see a Tennessee guy who has put in lots of work over the years on his channel and business doing well and picking up new sponsors. Best wishes on your future growth. Stay safe and warm out there. Thanks for the video.
@murkyturkey5238
@murkyturkey5238 8 күн бұрын
His sponsors are cool too, good stuff
@Negative13Prod
@Negative13Prod 12 күн бұрын
I always try reversing it. See if it might free the TXV. Surprise the unit isn’t on snow legs. Good to see I’m not the only one who writes the weigh on the tank.
@68larva
@68larva Күн бұрын
Hello Zac, I do not know what happened but I could not activate the subtitles to Spanish, change the ideome in the configurations of Yotube, changing your voice to be able to listen to it in Spanish, great contribution I think that if previously someone had already gone to diagnose that equipment time ago and manipulate badly at the moment of carrying out refrigerant gas load could not have put air into the system and leave non-condensable gases that over time would react with the oil and prove that the valve of Does expansion stick? I send you a strong friend hug from Mexico and I wish that your channel continues to grow you always learn something new with you. I am Cesar I hope the translation goes well and you can understand what I meant!!! 😅
@Big_Hank75
@Big_Hank75 11 күн бұрын
The only thing I would have done differently is try securing the bulb to the discharge line. I know they have electric heat to get them by but it’s a quick way to try and get that TXV to open. Again they have electric heat so doesn’t really matter. Good stuff 🤙🏻
@murkyturkey5238
@murkyturkey5238 8 күн бұрын
Never thought about that, thank you 😂
@christian81846
@christian81846 9 күн бұрын
I thought that was great! You didn’t waste any time once you added a small amount of refrigerant, you seen right away just like how I was telling myself. I think there’s a restriction cause I seen refrigerant going in but not coming out. Then you gave me confirmation that’s exactly what it was. Only thing is I would’ve liked to see you try and manually open the txv like you said with you hand to see if a difference would occur
@woodystokes1543
@woodystokes1543 11 күн бұрын
Love trane access is nice to work on 😊
@tonyowens6622
@tonyowens6622 11 күн бұрын
I agree with a couple of the others… I would have energized the reversing valve… you could have initiated a defrost cycle…. But good work.. I’m a 40 yr +. Service tech Doing residential and light commercial … last 24 working on Trane equipment..
@robalexander7348
@robalexander7348 11 күн бұрын
Thanks Zac, a interesting problem, i look forward to seeing the conclusion 🤔 Au
@Beans413
@Beans413 7 күн бұрын
Curious to know what happened? Had the same situation on a trane. EEV went then the sensor on the new one. Worked in heat but not ac. They sell a magnetic tool now to open them.
@tjackso0
@tjackso0 12 күн бұрын
I would have hooked up gauges and broken O. From the readings then, could determine outdoor or indoor txv issue... or if it's a charge problem.
@FixthisCD
@FixthisCD 10 күн бұрын
What I like about non heat pump system, not outside working on a heat issue outside ;)
@murkyturkey5238
@murkyturkey5238 8 күн бұрын
😂😂😂 so true
@Big_Hank75
@Big_Hank75 11 күн бұрын
I’ve swapped 3 outdoor TXVs in the last 2 days. All York systems under 2 years old 🤔
@GaBoysOutdoors
@GaBoysOutdoors 12 күн бұрын
So it was just stacking refrigerant basically with that outdoor txv?
@Patrick-h4r8z
@Patrick-h4r8z 11 күн бұрын
Seems like this video is pre arranged and already diagnosed before the video comes on. Would like to see it all from beginning and end and see what steps you take.
@tahoe6182
@tahoe6182 9 күн бұрын
So it is good to have a heat pump in tx since sometimes it snows and gets cold I’ve heard they do not work good in cold weather
@jonathanrobinson2949
@jonathanrobinson2949 10 күн бұрын
For all the issues I have had with Trane, they are still one of the best brand out there.
@pvtgarry
@pvtgarry 10 күн бұрын
Disagree. Train is so proprietary with their parts it makes it difficult to find parts sometimes. But you sir are entitled to have your opinion. Hope you have a great year.
@jonathanrobinson2949
@jonathanrobinson2949 10 күн бұрын
@pvtgarry, I agree that parts can be hard to get, but it also depends on the supplier.
@AlyssaHacker-z5y
@AlyssaHacker-z5y 4 күн бұрын
@@pvtgarry yep 5 weeks to get a outdoor txv from trane they suck. icp and lennox i always gets parts same week
@bassam1992MR
@bassam1992MR 11 күн бұрын
I use a similar way to figure out whats going on, and if i fine a bad outdoor TXV, i usually run the AC for few minutes and if it works fine then im sure its the outdoor TXV, that unit probably has an EXV
@davids970
@davids970 2 күн бұрын
Almost every trane I find a refrigerant leak on is the transition from copper to aluminum on the very bottom of the condenser coil
@manhpham8052
@manhpham8052 Күн бұрын
quick question, i am a newbie. i know during heat mode we hook up low side to true suction, what a about the high side gauge, i seen you hook up to the liquid line. i used to hook high side to the vapor line which is hot gas line in heat mode. so which it a better choice and can you explain
@andrewkalkofen9751
@andrewkalkofen9751 10 күн бұрын
You could bypass the low pressure switch so you don't have to hold the contactor in. Keep a jumper in your bag.
@mitchmacleod7575
@mitchmacleod7575 11 күн бұрын
If you weigh out the charge when you recover youll have a good idea if the system is low
@AlyssaHacker-z5y
@AlyssaHacker-z5y 4 күн бұрын
found bad outdoor txv trane run tru 5 week parts wait time for it to come in. why pistons are superior
@MindzEnt
@MindzEnt 12 күн бұрын
Good stuff, I always give replacement options on anything over 10 years old.
@Catayst-123
@Catayst-123 12 күн бұрын
Great Video Thank You Brother. You have A Nice Tool Bag. What brand is it ??
@richardthomas1743
@richardthomas1743 11 күн бұрын
I think that he uses a Veto Pro Pac tool bag.
@Catayst-123
@Catayst-123 11 күн бұрын
Thank You for Information ​@richardthomas1743
@kellyvanriper3767
@kellyvanriper3767 11 күн бұрын
Suction Line Temperature Sensor, I’ve had many cause what your having that’s if there’s one present
@omer9353
@omer9353 12 күн бұрын
hı from türkiye. I am a daıkın combi boiler technician too
@mariojackson6096
@mariojackson6096 12 күн бұрын
What is you camera setup
@Gabriel-vz7ml
@Gabriel-vz7ml 8 күн бұрын
Trane! Hp work great in California.
@Richard-zz2cb
@Richard-zz2cb 11 күн бұрын
Not surprising another bad Trane TXV. For some reason outdoor TXVs on Tranes go bad a lot. I change a lot on Tranes every year during the winter time
@Silky_boi
@Silky_boi 11 күн бұрын
Condemn the TXV, replace it, then condemn it again.
@jonathanbasiliere1327
@jonathanbasiliere1327 11 күн бұрын
Techs are know it alls and ive never seen one even close to physically fit
@xxjoigaxx
@xxjoigaxx 11 күн бұрын
How about showing all that you did to diagnose that instead of opening a panel, putting on probes and then talking about it.
@MightyMeehow
@MightyMeehow 11 күн бұрын
Bc then how would he make 10min long vids to get his KZbin monies
@Lilbean94
@Lilbean94 10 күн бұрын
He literally showed you what he did to diagnose it. You must be a homeowner trying to fix your own equipment.
@novacane3407
@novacane3407 9 күн бұрын
@@Lilbean94😂
@Lilbean94
@Lilbean94 9 күн бұрын
@@novacane3407 tell me in wrong 😂😂😂
@sauceghandi2799
@sauceghandi2799 9 күн бұрын
@Lilbean your exactly right!!!! Lmao just call one of us n pay n stop complaining
@Mastamurph162
@Mastamurph162 11 күн бұрын
Anyone else think this guy is cringe or just me? 😂
@JonathanGarcia-ve8kk
@JonathanGarcia-ve8kk 11 күн бұрын
I think you should consider watching other KZbinrs then 😇 Zack's a standup guy man. I think you judging another man is cringe
@fera.9811
@fera.9811 7 күн бұрын
You didn't show anything like you normally do!!!!!!
@richardjoseph8683
@richardjoseph8683 9 күн бұрын
Heat pumps don't work in cold weather!!!
@rocker8692
@rocker8692 11 күн бұрын
Let's not do work😂
@MurCurieux
@MurCurieux 11 күн бұрын
Dude that dropped impact on the line set tho
@edwardadkinson2965
@edwardadkinson2965 11 күн бұрын
Donald Trump was just elected president of the United States! And he talked about unity and not division! Can the haters not be the way they are in the comments. Try to be more helpful!! Let's do some work!
@chrisi8602
@chrisi8602 9 күн бұрын
This video was trash
Commerical HVAC Heating Repairs | Mistakes were Made...
24:15
Quality HVACR
Рет қаралды 29 М.
Gas Valve Troubleshooting Secrets Beginner HVAC Technicians Need
16:58
Support each other🤝
00:31
ISSEI / いっせい
Рет қаралды 81 МЛН
Why This Window Heat Pump Is Genius
13:24
Undecided with Matt Ferrell
Рет қаралды 1,2 МЛН
What 13 Years of Owning an HVAC Business Has Taught Me
23:49
Quality HVACR
Рет қаралды 6 М.
AMAZON Ductless Mini-Split - Installed by a PRO
8:35
Quality HVACR
Рет қаралды 13 М.
Learn Everything About Heat Pump Defrost
26:00
HVAC School
Рет қаралды 84 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,8 МЛН
Forced-air Furnaces: The What, Why, and How
22:05
Technology Connections
Рет қаралды 1,4 МЛН