Electrical Grounding Explained | Basic Concepts

  Рет қаралды 935,798

RealPars

RealPars

Күн бұрын

Пікірлер: 274
@realpars
@realpars 5 ай бұрын
Want to learn industrial automation? Go here: realpars.com Want to train your team in industrial automation? Go here: realpars.com/business
@seeithappen1
@seeithappen1 3 жыл бұрын
I graduated in Electrotechnics and Electronics but they neaver teached this so clear during my school years. Thanks a lot for this useful information. I had ground loops problems in the metal box of a desktop computer that messed up the powersupply. Now I know what to do to solve it.
@realpars
@realpars 3 жыл бұрын
That's amazing to hear! Thanks for your positive feedback. If you have any questions along the way, feel free to reach out!
@zohaibali3621
@zohaibali3621 3 жыл бұрын
You are putting lot of work in making these easy to understand animations. Excellent job and thanks alot for sharing.
@realpars
@realpars 3 жыл бұрын
Glad you like them!
@JKTCGMV13
@JKTCGMV13 3 жыл бұрын
As soon as you mentioned that the ground symbol was the most misused I thought to myself “guilty!” I’ve worked more with low voltage digital/analog circuits (mostly for classes at school, a little at work now) and we just use whatever symbol we like to denote a 0V point, without regard to whether it physically means chassis, Earth, or just a copper trace. At school this didn’t matter because every circuit we worked with was just a little bunch of wires and a battery, with no metal chassis or Earth connection to be confused with. We almost exclusively used the most common “Earth Ground” symbol, but some professors would use “Common Ground” or “Chassis Ground” in their schematics.
@sonnyfung5135
@sonnyfung5135 3 жыл бұрын
I have been searching a video like this for my life. TONS OF THANKS.
@realpars
@realpars 3 жыл бұрын
Glad I could help, Sonny!
@shariasharia1203
@shariasharia1203 3 жыл бұрын
Thump up for Electrical ground explanation, also I said TONS THANKS.
@jackzugna5830
@jackzugna5830 Жыл бұрын
This is why in elettronic is better use "0V reference A/D", in the schematic you can highlight the connection with the chassis and the ground (if necessary), but also the connection between 0V-digital and 0V-analog. If the target of your circuit are boats, cars or airplanes "ground" means the chassis of the veicle.
@JorgeMartinez-xb2ks
@JorgeMartinez-xb2ks 11 ай бұрын
Yeah, but in that case is the negative, right? That's the reason you have to disconnect the negative before when removing the battery.
@elmirelmir842
@elmirelmir842 3 жыл бұрын
I was also asking myself what those people mean by saying "grounding". Now it is clear for me. Thank you very much!
@realpars
@realpars 3 жыл бұрын
Glad to hear that, Elmir! Happy learning
@haabhhh4290
@haabhhh4290 3 жыл бұрын
@@realpars please elaborate on chasis grounding pls asap
@Troiberg
@Troiberg 3 жыл бұрын
@@haabhhh4290 Chassis ground will connect different metallic parts to a single point generally the enclosure and to earth. This will allow to redirect the electricity and avoid people to get shocked by touching enclosure if a wire is touching it.
@owenduck
@owenduck Жыл бұрын
Every man and his dog has a different take and definition on this. Frankly I don't think most people understand wtf is going on.
@g1sunstreaker584
@g1sunstreaker584 5 ай бұрын
Electricity is basically just modern magic as far as I'm concerned
@suntsu1434
@suntsu1434 4 ай бұрын
😅
@hubercats
@hubercats 3 жыл бұрын
Thank you for sharing this helpful video. The only quibble I have with it is calling “planet Earth” the true 0 volt reference. More generally, voltage is the integral of the electric field between two points in space, and one of the points is 0 volts by definition (I.e., 0 volts does not necessarily refer to the planet Earth). Your video is, nonetheless, very helpful.
@realpars
@realpars 3 жыл бұрын
Hey hubercats, thanks for your point of view.!
@sumilidero
@sumilidero 3 жыл бұрын
Its arbitrary, you can set whatever reference potential wherever you want and get valid results as long as you are consistent with the notation. The easiest way is to set reference potential to 0V (for ease of calculations) and to set it to planet earth. All in all, when safety is concerned, you most often stand on the ground, therefore you are also 0V and whatever potential you touch, that'd be the voltage to shock you :D If you have 1000V point, then it is 1000V. Would be much harder to do it when earth would be set as reference of 2342,1214V. Then it'd take w while to calculate voltage ;)
@katunduchabala7266
@katunduchabala7266 2 жыл бұрын
@@sumilidero 🤣
@johnfranco4023
@johnfranco4023 3 жыл бұрын
Superb presentation. Even people like me can understand about various grounding and importance of it.
@realpars
@realpars 3 жыл бұрын
Thank you, John!
@albertwashingtonjr2089
@albertwashingtonjr2089 3 жыл бұрын
You should also note why it's important to declare what "standard" you use for the basis of your discussion. Still people around who think the NEC is a standard when it's not and it specifically states that. Also the symbology changes between standards i.e. IEC, IEEE, NFPA and JIC. JIC I believe is outdated, but if you declare that's what you're using, then you have to go by that standard. Love the video. Good explanations!
@realpars
@realpars 3 жыл бұрын
Hi Albert. You are correct. The NEC is not actually a true "Standard". As per their own definition " Adopted in all 50 states, NFPA 70, National Electrical Code (NEC) is the benchmark for safe electrical design, installation, and inspection to protect people and property from electrical hazards.". In fact certain parts of the NFPA 70 can be rejected due to regional restrictions. Thanks for your input.
@eugenepohjola258
@eugenepohjola258 3 жыл бұрын
Howdy. Great. I usually say soil electrode and soil currents to discern from the fuzzy and blurry use of grounding and earthing. Regards.
@marcos13000
@marcos13000 Жыл бұрын
Exelente explicación. Me preguntó por qué no lo explican de esta forma cuando estudiaba la universidad. He visto muchos videos y con este me quedo claro lo que hace el PID.
@realpars
@realpars Жыл бұрын
Gracias, Marcos!
@s5960
@s5960 Жыл бұрын
Thank you so much for this high quality content. Your responses to almost each and every comment speaks volumes. Subbed.
@realpars
@realpars Жыл бұрын
Thank you very much for your kind comment, we truly appreciate that!
@RussLinzmeier
@RussLinzmeier 3 жыл бұрын
I have an old physics textbook that describes the earth as a limitless energy sink that electrons can be poured into without it ever filling up .
@sumilidero
@sumilidero 3 жыл бұрын
Thats why its wise to start our electrical coordinate system and place 0V there :D Although, you could set earth to whatever potential you want and still get valid results as long as you keep that notation along the way.
@baconsledge
@baconsledge 3 жыл бұрын
Keep em coming, RealPars! Thanks for all your good content.
@realpars
@realpars 3 жыл бұрын
Thanks a lot, Bob!
@dmeemd7787
@dmeemd7787 3 жыл бұрын
this channel is INCREDIBLE!
@realpars
@realpars 3 жыл бұрын
Thanks a million for your kind support!
@bvds2007
@bvds2007 3 жыл бұрын
Finally a near-complete discussion of ‘ground’. Excellent.
@realpars
@realpars 3 жыл бұрын
Thank you, Bernard!
@sujithbalendra7011
@sujithbalendra7011 3 жыл бұрын
This. is. very. important. and. great. lesson. so. i. appreciate. your. this. video. lesson. so. Thank. you. very. much
@realpars
@realpars 3 жыл бұрын
You're very welcome!
@sriyantra1939
@sriyantra1939 3 жыл бұрын
These techniques implemented in building (in1996) avionics test rig, at ADA B'lore.by (we) ex_HAL technicians under Sri V. Subbarao All symbols (some I don't come across) are at one place to learn more. Thanks
@vt8482
@vt8482 8 ай бұрын
Excellent video. Thanks for your enlightment!!
@realpars
@realpars 8 ай бұрын
You're very welcome!
@sharmatechnicalshorts9985
@sharmatechnicalshorts9985 11 ай бұрын
A lot of respect and love from India🇮🇳🇮🇳🇮🇳
@realpars
@realpars 11 ай бұрын
Thank you very much!
@kruskotv1311
@kruskotv1311 Жыл бұрын
Ultimately, earth and ground really boil down to what its used for, as 0 volts reference point, and/or wire for all "extra" current to flow to/trough, especially in case of fault.
@subuvenkat5334
@subuvenkat5334 3 жыл бұрын
Thanks for the video, I was looking for such explanation so long. Please upload another video explaining the remaining ground types
@realpars
@realpars 3 жыл бұрын
Thanks a million, Subu! We appreciate such great support.
@Texashog11
@Texashog11 Жыл бұрын
Ultimately you have to know the standard that was used for the design of the facility, then understand changes made afterwards may or may not have adhered to those standard, then you have to understand the symbols as defined on those drawings because other symbols are legitimate if they are listed on the drawings. Drawings are a higher order of precedence than standards.
@realpars
@realpars Жыл бұрын
Thank you for adding that!
@ardentdfender4116
@ardentdfender4116 3 жыл бұрын
Damn excellent video explanation. Some Ground concepts I've never even quite heard of like the Analog and Digital Ground as well.
@realpars
@realpars 3 жыл бұрын
Thanks a million, Ardent!
@manaoharsam4211
@manaoharsam4211 2 жыл бұрын
Great illustrations.
@realpars
@realpars 2 жыл бұрын
Thank you!
@surferdude642
@surferdude642 2 жыл бұрын
At 2:00 you show a main electrical panel or first means of disconnect. The ground and neutral bus bars look to be separated. They must be connected or just have one. The neutral, equipment ground and earth ground are bonded there. The current flows in a closed loop which includes the transformer and no current on the ground wires under normal operation. In case of a ground fault the current on the ground wires will still go to the neutral on the transformer because it's bonded to the neutral in the main panel and the breaker will trip if the current more than the rating of the breaker. It doesn't flow to earth ground as the impedance is too high. The primary purpose of earth ground and the ground rod is to shunt outside static such as lightning strikes to it's source, the earth, and not your home electrical system.
@realpars
@realpars 2 жыл бұрын
Hello @Ted Sanders. Thanks for reaching out to us. You are absolutely correct. The neutral and ground are to be connected together for sure. We don't have a physical wire connecting the 2 bars together but. They are connected via the ferrous metal enclosure, which I believe is acceptable.
@surferdude642
@surferdude642 2 жыл бұрын
@@realpars I don't believe that is acceptable. You need a more purposeful connection, not an incidental one. The most common way and only in a main panel, not sub panel, is to use the green screw supplied. It bonds the ground, neutral bus bars and the case.
@james77011
@james77011 3 жыл бұрын
mayb u guys should make a group of videos on electrical fundamentals
@realpars
@realpars 3 жыл бұрын
Thanks for the suggestion, James!
@abs1426
@abs1426 3 жыл бұрын
Thanks i had 1 query, this video gave me solution! 👍🏽🙏🏼
@realpars
@realpars 3 жыл бұрын
Glad to hear that! Happy learning
@h7opolo
@h7opolo 2 жыл бұрын
excellent video
@realpars
@realpars 2 жыл бұрын
Glad you liked it!
@onel276
@onel276 3 жыл бұрын
Video editing is awesome
@realpars
@realpars 3 жыл бұрын
Thank you!
@rogerscottcathey
@rogerscottcathey Жыл бұрын
When using a two prong tester to find the hot line, we can old one prong between our thumb and finger. Inserting the other prong in the hot socket, the bulb will light. Our body is absorbing electrons. Does that mean "ground" means electron hungry? Are our bodies behaving like capacitors? If we held that prong all day with the other on the hot side of a plug, would we reach capacity?
@realpars
@realpars Жыл бұрын
Hi Roger. Thanks for reaching out. I'm not sure what you mean by our body being electron absorbers. We certainly have several electrons in our body and if we contact a voltage source or a source of EMF, these electrons will begin to move if they have an "Escape route". And that is not a good thing. We can be killed with less than 50 mA of current flow. We aren't like a capacitor and our bodies won't "charge" like a capacitor. As a side point, we can't charge capacitors with an AC supply. A capacitor is charged as you describe with a DC source.
@rogerscottcathey
@rogerscottcathey Жыл бұрын
@@realpars : I guess what mystifies me is the fact I'm wearing rubber soles shoes and feet off the ground in my house on wooden floors, and just holding one leg of the idiot light current is moving in and out. How does that work if I'm not, at least temporarily, absorbing electrons?
@Savage-lx5yj
@Savage-lx5yj 3 жыл бұрын
Excellent! Clear and concise!
@realpars
@realpars 3 жыл бұрын
Glad it was helpful!
@chiawater9784
@chiawater9784 2 жыл бұрын
Excellent knowledge
@realpars
@realpars 2 жыл бұрын
Great to hear that!
@mohfiroz7700
@mohfiroz7700 3 жыл бұрын
Very good informative video, thanks.
@realpars
@realpars 3 жыл бұрын
Glad it was helpful!
@shaunmaher258
@shaunmaher258 2 жыл бұрын
Thank you for the great info!
@realpars
@realpars 2 жыл бұрын
Our pleasure, Shaun!
@hifa6205
@hifa6205 Жыл бұрын
Lol the hardest part for me to understand was ground dis this explained it in under 3 minutes, thanks
@DieselGeneratortraining
@DieselGeneratortraining Жыл бұрын
Please make video on LV generator neutral grounding and it effects , advantages and disadvantages
@realpars
@realpars Жыл бұрын
Thanks for your topic suggestion! I will happily go ahead and pass this on to our course developers.
@Mrdealornodeal618
@Mrdealornodeal618 3 жыл бұрын
Great explanation.
@realpars
@realpars 3 жыл бұрын
Glad you think so, Will!
@AldenTechnology
@AldenTechnology 3 жыл бұрын
Now I understand the differences between.
@realpars
@realpars 3 жыл бұрын
Glad to hear that!
@JorgeMartinez-xb2ks
@JorgeMartinez-xb2ks 11 ай бұрын
Thanks a lot for this excellent explanation
@relayprotection
@relayprotection 3 жыл бұрын
That is a great explanation, thank you so much!
@realpars
@realpars 3 жыл бұрын
Glad you enjoyed it!
@cck0728
@cck0728 3 жыл бұрын
Excellent video. Being a mechanical, why "electrical noise" create havoc? Thanks for your excellent work.
@realpars
@realpars 3 жыл бұрын
Electrical noise is often induced into or interferes with normal operational or control signals. If these control signals are altered in any way, false readings can occur resulting in incorrect responses.
@cck0728
@cck0728 3 жыл бұрын
@@realpars Thanks for your kind reply. Keep us educating. Thanks.
@kruskotv1311
@kruskotv1311 Жыл бұрын
2:05 , for all my Europe brothers, this is not the case so don't be confused. In Europe, Earth ground wire is separate, connected directly to the rod that is stuck in the ground, and at no point do neutral and ground wires connect.
@ralanham76
@ralanham76 Жыл бұрын
Does neutral have a voltage compared to ground ?
@okaro6595
@okaro6595 10 ай бұрын
No, there is nothing "in Europe". Different countries have diffrerent systems and some have several especially if one counts older installations. Every grounding system is used in Europe. In Finland for example older homes have TN-C where the neutral is used for grounding all the way to the socket. Newer use separate wires inside the house but common outside.
@dekunet
@dekunet 3 жыл бұрын
Awesome video! Keep doing this stuff
@realpars
@realpars 3 жыл бұрын
Thanks a lot, Pedro!
@curtpiazza1688
@curtpiazza1688 Жыл бұрын
Informative!
@realpars
@realpars Жыл бұрын
Thank you very much!
@KevinNguyen-tw5ml
@KevinNguyen-tw5ml Жыл бұрын
Thank you very much!
@realpars
@realpars Жыл бұрын
You're very welcome!
@richmond4884
@richmond4884 3 жыл бұрын
Thanks you! You really give imformative video thank you very match... God bless
@realpars
@realpars 3 жыл бұрын
Amazing! Glad to hear that, Richmond!
@ronsmith7739
@ronsmith7739 Жыл бұрын
Clear as mud !!!!!
@realpars
@realpars Жыл бұрын
Thank you, Ron! Great to hear that.
@divyanshukumar9954
@divyanshukumar9954 3 жыл бұрын
VERY VERY NICE VIDEO SIR
@realpars
@realpars 3 жыл бұрын
You're very welcome!
@cynthiamarshall1517
@cynthiamarshall1517 3 жыл бұрын
For those who knew nothing about electricity before watching this video, then the phrase quote " electrical noise" should have been explained. I still don't know what it means & will have to look it up before watching anymore videos to learn about electricity in our homes, in our bodies and on planet earth.
@realpars
@realpars 3 жыл бұрын
Hi Cynthia. Thanks for your comment. As you mention, you can find loads and loads of info on the term “electrical noise” on the internet. As it wasn’t a main theme or focus of the video, we didn’t go into great detail. In short, electrical noise is any “unwanted” induced signal or voltage that interferes with or can cause problems with the electrical circuit. electrical noise is created by lots of pesky things that happen inadvertently such as radio frequency interference.
@JunaidKhan-ub4es
@JunaidKhan-ub4es 3 жыл бұрын
Good sir
@chadlevitan7886
@chadlevitan7886 Жыл бұрын
This video is informative, but also wrong when we're talking about the power supply to your house. Ground in that case is referenced to both the utilities neutral and earth ground, so it's confusing. However the path of least resistance tells us that the majority of the flow returns to the source via neutral when the ground circuit is used. The ground rods aren't there to reference earth - they dissipate static and other high voltage sources such as lightning. I have had many people argue this, stating that neutral is referenced to ground and not the other way around. My rebuttal is simple. Remove all grounding to a house. Does the single phase power still function at or around 120V? The answer is yes. In a home, the "ground" is for safety and high voltage discharge, not reference to the hot leg to provide 120v L1 or L2 to neutral/ground.
@realpars
@realpars Жыл бұрын
Hiya.... Thanks for your input. It's always great to hear from our readers.
@arthurgebarusherman4715
@arthurgebarusherman4715 Жыл бұрын
Very good
@realpars
@realpars Жыл бұрын
Thank you very much!
@vasuv59
@vasuv59 2 жыл бұрын
Excellent
@realpars
@realpars 2 жыл бұрын
Thank you so much!
@sivakumarbugide8877
@sivakumarbugide8877 11 ай бұрын
As we all know that circuit needs to be closed path to flow current. When live wire touches body of equipment and that equipment is grounded, how it makes closed path? Because live wire is coming generation station or near by transformer so current follows all the way to generation station to make close path?
@realpars
@realpars 11 ай бұрын
Hi there. Thanks for your question. Ultimately, all supposedly grounded equipment is grounded to the same electrical point. This point is not usually the same physical point, but it is the same electrical point therefore a closed circuit is formed. I hope that answers your question.
@asapmimic1289
@asapmimic1289 2 жыл бұрын
I’m still confused. How is a car frame a viable option as a ground? What about the cars chassis or frame allows it to be a ground? It’s not a copper rod in the ground it’s just a huge metal body. The reason I ask is because I’m trying to create a home audio system out of car speakers. The box is meant to be somewhat portable but I have no way of grounding it to the earth and still being portable. Is a metal plate the solution/is it a viable ground point?
@realpars
@realpars 2 жыл бұрын
Hi @Asap Mimic. Here's where the term "ground" becomes confusing. In your situation, "ground" is the negative terminal of whatever you are using for a 12-volt DC power supply. In the car, the "ground" is the negative terminal of the battery, which is the same as the frame of the car. In order to operate the same car system at home, you'll need a 12-volt DC power supply. The negative terminal of that 12-volt power supply will be the "ground". you do not need to connect to any earth ground.
@EngineerTaj
@EngineerTaj 3 жыл бұрын
Informative ❤️
@realpars
@realpars 3 жыл бұрын
Glad it was helpful!
@ABRUSAHAELEKTRIK
@ABRUSAHAELEKTRIK 3 жыл бұрын
Thanks for sharing
@realpars
@realpars 3 жыл бұрын
You're very welcome!
@ominence5573
@ominence5573 3 жыл бұрын
Great video, been waiting for this one!!
@realpars
@realpars 3 жыл бұрын
Hope you enjoyed it!
@james77011
@james77011 3 жыл бұрын
perfect video
@realpars
@realpars 3 жыл бұрын
Thank you, James!
@james77011
@james77011 3 жыл бұрын
@@realpars i studied Electronics and electrical wiring and some of this ground symbols are misunderstood at times 🤦
@dido1803
@dido1803 Жыл бұрын
Really great information
@realpars
@realpars Жыл бұрын
Glad it was helpful! Thank you for sharing
@rashidak7821
@rashidak7821 3 жыл бұрын
Good video bro
@realpars
@realpars 3 жыл бұрын
Glad you liked it!
@axelateon1384
@axelateon1384 Жыл бұрын
i got a question mr if i got one big workshop with machines of 50iA 100iA and 250iA (including plcs for each one) how do i know how many electrical ground holes i need??
@realpars
@realpars Жыл бұрын
Hello @axelateon. Thank you for your question. I don't know what machines you are referring to. It's always best to consult your local electric authority to inquire about grounding requirements as they often vary from one authority to the next.
@muhammadsajjad1723
@muhammadsajjad1723 2 жыл бұрын
Hi Sir I have a confusion Transformer neutral is grounded so when we using neutral on load side, there is a current flows in neutral..my question is if there is current flowing in neutral then why transformer C.B is not tripping by earth fault?
@realpars
@realpars 2 жыл бұрын
Hi Muhammad. I'm not sure I understand your question. The neutral wire current is normal while the ground wire provides a path for abnormal electrical current to earth. A GFI CB detects earth current as it is faulty. It will not detect neutral current because it is normal.
@allezvenga7617
@allezvenga7617 3 жыл бұрын
Thanks for your sharing
@realpars
@realpars 3 жыл бұрын
You're very welcome!
@salehghanimi8725
@salehghanimi8725 3 жыл бұрын
Great job
@realpars
@realpars 3 жыл бұрын
Thank you, Saleh!
@luiscarloschoqueartunduaga9934
@luiscarloschoqueartunduaga9934 3 жыл бұрын
¡¡¡Guauu!!! Excelente video. Gracias por compartirlo.
@realpars
@realpars 3 жыл бұрын
De nada, Luis!
@kasmicmike4535
@kasmicmike4535 3 жыл бұрын
Great work
@realpars
@realpars 3 жыл бұрын
Thank you!
@mrsaiful7776
@mrsaiful7776 3 жыл бұрын
Thank sir.👍
@mahmoodadnan1555
@mahmoodadnan1555 3 жыл бұрын
Sir, thank you very much for nice explanation. Sir, can you explain in details the earthing procedures of ac, dc earthing of pv solar system and components. Also ac & dc earthing of transformer and transmerless inverters.
@realpars
@realpars 3 жыл бұрын
Hi Mahmood, Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@johanburger6109
@johanburger6109 3 жыл бұрын
Love this channel
@realpars
@realpars 3 жыл бұрын
Great to hear that, Johan!
@thepastofpeople9998
@thepastofpeople9998 3 жыл бұрын
Thank you
@realpars
@realpars 3 жыл бұрын
You're welcome!
@magicchanelwithsaeediqbalm7848
@magicchanelwithsaeediqbalm7848 11 ай бұрын
Plz also cover electrical machine
@realpars
@realpars 11 ай бұрын
Thanks for your topic suggestion!
@Abouduno
@Abouduno 3 жыл бұрын
awesome video I really appreciate this
@realpars
@realpars 3 жыл бұрын
Glad it was helpful!
@chiawater9784
@chiawater9784 2 жыл бұрын
Thanks
@realpars
@realpars 2 жыл бұрын
You're very welcome!
@coloradowilderness3139
@coloradowilderness3139 3 жыл бұрын
Really nice.
@realpars
@realpars 3 жыл бұрын
Thank you!
@Billygoatbuff
@Billygoatbuff 3 жыл бұрын
Could a voltage source with a lower voltage be used instead of grounding? Doesn't grounding waste electricity to some degree?
@realpars
@realpars 3 жыл бұрын
It seems like the answer would be "YES", but the scenario you describe is not feasible. A power supply does not provide voltage through 1 wire alone. There needs to be a load and a wire connected back to the common side of the power supply. The voltage is actually a voltage difference (between + and COM) that drives the device. The device only consumes the amount of power required, and this results in a voltage drop across the device. If there is no load (voltage drop), then you have a short-circuit. Current flows from (+) to COM, or for physicists, positive holes flow from (-) to (+). Grounding is a separate issue. Grounding is provided as safety for short circuits that may electrify housings or cabinets. Grounding does not waste electricity because, under normal circumstances, there is no flow of current to the ground. In this video, we learned it is common to represent 0V (or COM) with a ground symbol, which is not typically earth ground but rather the (-) of the power supply. Using the ground symbol allows us to simplify the electrical diagram, as shown at 3:25 in the video.
@vtorsi610
@vtorsi610 3 жыл бұрын
@@realpars In SWER electrical power distribution, the EARTH is used as the "return wire" and yes the resistance of the ground path does waste some energy. If the "ground path" has the same or lower resistance vs a wire than it makes no difference, example: the car's metal frame.
@louf7178
@louf7178 3 жыл бұрын
5:00 I'm not sure the ground loop solution depicted is necessarily a solution. E.g. if the current from block #2 (left to right - 1, 2, 3) is much greater than the current at block #1 then circuit #2 is going to effect circuit #1 -or- #1 is much less than #2. I believe this is why these grounds are advised to be spaced apart far enough.
@realpars
@realpars 3 жыл бұрын
Hi Lou. Thanks for your input. The circuit #2 (right-hand) depiction could be drawn differently. I think the audio description would be clearer if the return from each block went directly to a single connection point, such as a bolt connected to the chassis of a vehicle. Unfortunately, the current depiction could be interpreted as the return from Block 1 connects to the return of Block 2, then the 2 returns are connected at a common ground point.
@prasadomprakash5077
@prasadomprakash5077 3 жыл бұрын
Hi sir. What a great vedio, with simple explanations easy to understand. By the by I would like to know sir, what is that the grounding problems arises in Active Magnetic Bearings systems. Thanks you inadvance.
@realpars
@realpars 3 жыл бұрын
Hi Prasad, Thanks for your kind comment, glad to hear that the video course was helpful! The grounding problems that arise in active magnetic bearing systems would be a very interesting topic for a future video course. I will go ahead and forward this as a topic suggestion to our course developers! Thanks for sharing and happy learning!
@funny11744
@funny11744 3 жыл бұрын
Hi, I saw that grounding body îs quite necessary especially for people with cronic disease as I am. I live at 4 th floor, so I have to use grounding of electricity socket. But I want to add 2 fuse in series on the grounding cable for safety reason. Any idea about what type of fuse ( what curent, voltage) . Thanks
@realpars
@realpars 3 жыл бұрын
Hi there. You've asked an interesting question for sure. The jury is out on the effectiveness of fuses in series. Some will tell you that a second fuse serves no purpose and others say that it does. I'm not sure how you are planning to double fuse as you'd have to do some serious cable splicing in order to insert your fuses in series. Quite likely, your circuit breaker provides all the protection you need??? But, not really knowing what you are trying to protect, it's difficult to provide an answer.
@funny11744
@funny11744 3 жыл бұрын
@@realpars the fuses could be put în a plastic tube according to fuses and cable dimensions. Whole cable and fuses must tested preferably in laboratory. If anyone was in my place when a lightning strike(I saw that strike) street electric transformer ( and distroyed it) and then the lightning went out 10 centimeters from electric socket situated at 2 meters from me, you will serious think to put at least 2 fuses ! And other protection measures.
@funny11744
@funny11744 3 жыл бұрын
@@realpars As You know at high voltage it appears flashover phenomenon - I saw it with my eyes in a factory at electric test and I see the lightning came out from socket ar home. In this case it îs advisable to prolong insulation ....adapt things.
@cck0728
@cck0728 3 жыл бұрын
Excellent video. Can anyone tell please than when comes the role of ELCB (earth leakage circuit breaker)? Thanks.
@alexvdz8840
@alexvdz8840 3 жыл бұрын
The device measures current differential on the 2 lines (L & N in europe). If the amount of returning current is smaller than the incoming current, that means there is a current leaking and this is dangerous (fire, electrocution..) So it breaks the circuit, until you manually turn the switch up again. Usually they are 300mA, for humid rooms like bathrooms they must be 30mA
@cck0728
@cck0728 3 жыл бұрын
@@alexvdz8840 Thanks for your kind reply. Keep it up...
@LawatheMEid
@LawatheMEid 3 жыл бұрын
Thanks👍🏼
@markhodgson2348
@markhodgson2348 3 жыл бұрын
Ground is needed for project
@swamisrinivasan1893
@swamisrinivasan1893 3 жыл бұрын
what is TT &TNS system of earthing explain with diagram why TT system alone is not enough
@okaro6595
@okaro6595 3 жыл бұрын
In TT the earth is provided only locally. The earth connection on a socket leads to physical earth and nowhere else. The problem is that impedance of the earth may be too high to trip the breaker in case of a fault. However, nowadays, that can be fixed with the use of RCDs. In TN system the earth is provided by the electric system, There are three variations: TN-S, TN-C and TN-C-S. In TN-S the house gets a separate earth and neutral and these are not connected inside the house. Eventually they will lead to the same place. Where they are connected is the business of the electric company, Ideally at the transformer. In TN-C the house gets a common neutral and earth i.e. a PEN-wire and the same wire goes all the way to the sockets where is is separated. This is obsolete and such systems are no longer installed. In TN-C-S. The house again gets a common neutral and earth but they are separated at the main panel and kept separate. This prevents the raise of voltage in the earth cable and therefore stray currents that can generate interference. In TN in many counties a local earth electrode is also required to reduce risk in case of a PEN-fault. In the UK that is not required. Note that in apartment buildings where different entities are responsible for wiring inside and outside the apartment things can get more complicated. MY apartment gets separate earth and neutral but they are combined as the installation inside the apartment is much older.
@skylerbowerbank5847
@skylerbowerbank5847 3 жыл бұрын
I have just 1 question suddenly Is it possible for 2 different "earth grounds" to have different voltages?
@realpars
@realpars 3 жыл бұрын
Hi Skyler, Well, you’ve opened a can of worms with that question. 😊 The electrical potential of Earth is not always the same everywhere. If you have a voltmeter with very long leads connected between 2 rods driven into the ground at locations quite far apart, you may actually see a potential difference. That could cause a current flow between these 2 rods if a circuit was completed. That’s why it’s best to connect all supposedly grounded devices to one reference point, or one Earth grounded rod, if that is your reference point.
@skylerbowerbank5847
@skylerbowerbank5847 3 жыл бұрын
@@realpars Thank you very much
@AbdullahAlmarhon
@AbdullahAlmarhon 3 жыл бұрын
Why most electronics reference using earth ground symbol? BTW nice vid
@realpars
@realpars 3 жыл бұрын
Hi Abdullah. That's a very good question. There really isn't a good answer. Convenience? Familiarity? What all viewers should know though is that just because the earth ground symbol is used does not mean that the common or ground points(s) are actually connected to earth.
@cliftonfoy5907
@cliftonfoy5907 3 жыл бұрын
Not splitting hairs here but electricity flow from negative to positive on an dc system. But still good video.
@oshavlfarms7239
@oshavlfarms7239 3 жыл бұрын
Not splitting hairs but it's electrons that flow that direction, holes flow the other direction, he's using common parlance. I'm an EE.
@vtorsi610
@vtorsi610 3 жыл бұрын
@@oshavlfarms7239 Electron flow vs Conventional Current flow
@oshavlfarms7239
@oshavlfarms7239 3 жыл бұрын
@@vtorsi610 yeah I get that, it is a bit annoying when people try to correct that though because there are really two charge flows, one in either direction, electron flow and hole flow. That kind of "actually..." Is usually from people who just heard that fact but don't know the whole story.
@ahmedmaled1366
@ahmedmaled1366 3 жыл бұрын
Great job ! Please can u make a video about TT ; TN and IT shematics ?
@realpars
@realpars 3 жыл бұрын
Hi Ahmed! Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@rustinstardust2094
@rustinstardust2094 2 жыл бұрын
Can you be electrocuted by touching the ground, though? I was being taught how to use an outlet tester and the instructor said we insert one end into the socket and hold the other end in our hand, and that way our body acts as a ground. I did not understand how I did not get electrocuted.
@realpars
@realpars 2 жыл бұрын
Hello @Rustin Stardust. Thanks for your feedback. I'm not sure what tester you are referring to. I'm curious about holding one end of the tester in your hand. Is this tester similar to a multimeter? Without more detail about your tester I can only assume it has an extremely high resistance and therefore would draw negligible current when connected to any ground, or your body connected to ground. I'd be happy to reply to any additional feedback.
@tedlahm5740
@tedlahm5740 3 жыл бұрын
Conventional DC current in the video? Thank you
@realpars
@realpars 3 жыл бұрын
Hi Ted. Hmmm.....we didn't talk about any DC conventions in our video as we were mainly focused on AC grounding circuits. What exactly did you have in mind? as you know, conventional current flow is based on the notion that current flows from positive to negative. That notion was debunked earlier in the last century when it was discovered that current flow is actually negative to positive. No bother really, as current is still current and bites if you touch it.
@bou2460
@bou2460 3 жыл бұрын
i would so much a video on how to check and correct easily ground loops. Such a shame on my site
@realpars
@realpars 3 жыл бұрын
Hey! Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@mahmoodadnan1555
@mahmoodadnan1555 3 жыл бұрын
Sir, I am again submitting request. Sir, can you explain in details the earthing procedures of ac, dc earthing of pv solar system and components. Also ac & dc earthing of transformer and transmerless inverters.
@realpars
@realpars 3 жыл бұрын
Hi Mahmood, Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@Mau365PP
@Mau365PP 3 жыл бұрын
Why use the "Chasis Ground" instead of "Analog Ground" in the Op Amp example you gave? 🤔
@realpars
@realpars 3 жыл бұрын
Hiya Mau365PP. Yup, my point exactly. Why is that ground symbol used in this opamp schematic? Who decided to use that symbol, and where exactly is it connected? Is it connected to chassis? Analog ground? Hard to tell from the schematic itself.
@Amalokch
@Amalokch 3 жыл бұрын
Next: TN-S installations
@darciosabbadini8869
@darciosabbadini8869 3 жыл бұрын
Ground Control to major tom
@realpars
@realpars 3 жыл бұрын
Good one. :)
@ismagine
@ismagine 3 жыл бұрын
Subscribed
@chuckredd9131
@chuckredd9131 3 жыл бұрын
Not being an electrican... Why would you need two earth grounds coming from an electric meter? I've always had one and when the meter was changed out for a newer type I was told I would now have to have two grounds. I would think if the ground was properly installed, one should suffice. (just wondering)
@realpars
@realpars 3 жыл бұрын
Hi Chuck. That's an interesting question. Device bonding requirements are based on national or quite often, regional codes. One would think that one ground would do the job, but codes and standards always have safety in mind. Multiple bonding seems to make sense onsidering the number of potential failures due to connections, joints, corrosion, etc...etc.
@chuckredd9131
@chuckredd9131 3 жыл бұрын
@@realpars Seems like "job security" at the State level. Mine was a complete new set up, Meter, box, wiring, the whole thing. A new set up exactly like mine 15' away was only required one ground. My use is 1 security light. They are running compressors, welders, and other equipment. Maybe inspector got paid off. Thanks for your reply & input, appreciate it!!!
@surferdude642
@surferdude642 2 жыл бұрын
When a ground rod is installed the resistance of the rod in the soil must be checked with a special meter for this purpose. The reading must be 25Ω or less. If not, another ground rod must be installed at least 6 feet away until the resistance becomes 25Ω.
@danielteyehuago1633
@danielteyehuago1633 3 жыл бұрын
The writing blocks the diagram
What is a Contactor? | Working Principles
9:47
RealPars
Рет қаралды 283 М.
The Big Misconception About Electricity
14:48
Veritasium
Рет қаралды 23 МЛН
СОБАКА ВЕРНУЛА ТАБАЛАПКИ😱#shorts
00:25
INNA SERG
Рет қаралды 3,8 МЛН
What is Ground
19:08
Vocademy - Electronics Technology
Рет қаралды 17 М.
What is an Interlock?
9:14
RealPars
Рет қаралды 178 М.
What is the Difference Between Grounding, Bonding and Neutral?
15:15
Electrician U
Рет қаралды 101 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,6 МЛН
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 6 МЛН
Ground Neutral and Hot wires explained - electrical engineering grounding ground fault
11:13
Earthing vs. grounding
7:06
Paul Saladino MD
Рет қаралды 136 М.
Grounding and bonding: Definitions and details
12:42
Eaton
Рет қаралды 98 М.