REF COMPRESSOR OVERLOADING TROUBLE

  Рет қаралды 23,704

leckyjake

leckyjake

Күн бұрын

Пікірлер: 54
@christopherherreracastro7291
@christopherherreracastro7291 2 жыл бұрын
A very important video, just a few days I have this trouble with some vegetables But the original breakers have the possibility to set to 18 Amp behind the sticker of 16 Amp you will have the clock to arrange the amp Great video !!
@ethanlove5513
@ethanlove5513 2 жыл бұрын
Excellent video keep them coming.
@fahimjamader9830
@fahimjamader9830 Жыл бұрын
Informative vlog. Please shoot more videos like this specially reefer container troubleshooting. Thanks 👍
@bjornmagnusson259
@bjornmagnusson259 2 жыл бұрын
interesting information greetings from sweden
@leckyjake
@leckyjake 2 жыл бұрын
thank you very much. have a good day!
@reefercontainerph4182
@reefercontainerph4182 2 жыл бұрын
Very informative video! Thanks for sharing your knowledge sir.
@Efforts....
@Efforts.... 2 жыл бұрын
Very useful information
@biorosary8805
@biorosary8805 2 жыл бұрын
Great appreciate to your work ❤️
@leckyjake
@leckyjake 2 жыл бұрын
thanks
@osmankaya9664
@osmankaya9664 2 жыл бұрын
Good job Sir!
@dammie2h
@dammie2h 2 жыл бұрын
Thank you for video
@ВикторияЛирник-я9и
@ВикторияЛирник-я9и 2 жыл бұрын
Good video and 🙏information
@leckyjake
@leckyjake 2 жыл бұрын
thank you
@prajeshbhatt2294
@prajeshbhatt2294 2 жыл бұрын
Interesting info, thank you
@leckyjake
@leckyjake 2 жыл бұрын
thank you for watching
@bjornmagnusson259
@bjornmagnusson259 2 жыл бұрын
have you 16 amp on reefer units?? On trailer reefers we have 32 amps...400 volt ..both on carrier unit and thermoking unit !!
@leckyjake
@leckyjake 2 жыл бұрын
our reefer socket is 440/3P/ 32 amperes.
@bjornmagnusson259
@bjornmagnusson259 2 жыл бұрын
@@leckyjake okej thanks for the info
@ChoroTesla
@ChoroTesla 2 жыл бұрын
Thats Good Infor so if i dont have a circuit brewker that you can regulate amount of current drawing what should i do if current drawn from the power source is higher than supposed to pass on C.B?
@leckyjake
@leckyjake 2 жыл бұрын
you have to borrow from a non hotstuff containers
@ChoroTesla
@ChoroTesla 2 жыл бұрын
@@leckyjake Thank you sir. And Welcome to Tanzania🇹🇿🇹🇿🇹🇿🇹🇿🇹🇿 and Visit our National Parks
@leckyjake
@leckyjake 2 жыл бұрын
Thank you for the support
@ayyapansongs4447
@ayyapansongs4447 2 жыл бұрын
Your videos is very good 🔥👌🏻
@leckyjake
@leckyjake 2 жыл бұрын
thank you for watching
@r.4169
@r.4169 Жыл бұрын
👍🏽
@teslapower220
@teslapower220 Жыл бұрын
0:55 does the switch on the unit also turn off when the unit trips?
@FrankMatawai
@FrankMatawai 9 ай бұрын
Well explained, am currently doing my on job training with an on call company in Papua New Guinea. Still at my basic HVAC level and I like all your videos. I have a question about the Code LO being displayed "Low Mains Voltage how can I bypass.
@alexsyzo2645
@alexsyzo2645 2 жыл бұрын
Thank you boss
@leckyjake
@leckyjake 2 жыл бұрын
thanks for watching
@mirneyazsharif2911
@mirneyazsharif2911 7 ай бұрын
Thanks sir
@walterdarvin9983
@walterdarvin9983 2 жыл бұрын
Pare Paso👍
@johncantrell614
@johncantrell614 2 жыл бұрын
Did it take you a long time to get the refrigeration basics learned? Did you learn most of it in the classroom, or was it mostly on the job?
@leckyjake
@leckyjake 2 жыл бұрын
to be honest, i learned it mostly on the job. every vessel has different set up and how much electrical situation I can have. so refrigeration is just part of the responsibility onboard
@johncantrell614
@johncantrell614 2 жыл бұрын
@@leckyjake thank you for your reply. I am a shipyard electrician who has found myself in a situation that the air conditioning technician had quit his position, and I have been put into his position until we can find another one. Mostly i would be doing the periodic maintenance, and some of the electrical troubleshooting, but I must admit that there is a lot to learn, and many things, like working with the Freon, that I cannot do, unless they would send me to ac school to get the proper certifications. But I do what I can electrically, that is why your videos are very informative. Thanks again!🙂
@dacsbonie2827
@dacsbonie2827 2 жыл бұрын
Anu po requirements mag apply as Electrician po? Reefer technician po din ako with nc2-nc3 from tesda po..new subscriber po sana ma guide mo din ako idol..the best tutorial po madami ako natutunan..keep it up and god bless
@rb1m426
@rb1m426 2 жыл бұрын
👋
@cozzm0AU
@cozzm0AU 2 жыл бұрын
I don’t understand how you can clamp one side of the breaker and see 17A and clamp the other side and see only 3A ? You’re not losing 14A through heat. If the contacts on the breaker were bad I can understand large loss but not even that much. I’m not Qualified Electrician but I deal with circuit breakers and fridge compressors with my work.
@leckyjake
@leckyjake 2 жыл бұрын
that is the power meas circuit of which measuring the fans and heaters only, compressor not included.
@nathanielreid4967
@nathanielreid4967 2 жыл бұрын
@muhammadibadurrohman6201
@muhammadibadurrohman6201 4 ай бұрын
Any reeferman on board sir?
@benjaminowusuboahene1738
@benjaminowusuboahene1738 Жыл бұрын
🎉
@Josh-b3c
@Josh-b3c 2 жыл бұрын
Why doesn't the display show you the maximum current that it is drawing instead of just that fans only current
@AjayKumar-ll2zb
@AjayKumar-ll2zb 2 жыл бұрын
Compressor connection circuit not connected through the power module. That is the reason why controller is reading less amps.
@harishsingh9961
@harishsingh9961 Жыл бұрын
Sir iam hvac /reefer container technician sir, need to more information on the reefer container
@timorleste1323
@timorleste1323 2 жыл бұрын
Hi sir.. i have so many question since im a beginner.im a oncall technitian And recently i got same problem with carrier And i try my best to fix but failed dont have idea what to do. If only you can create a group chat so that you share opinion anytime. Thnks.
@Entertainment_enjoy795
@Entertainment_enjoy795 2 жыл бұрын
i have reefer technician whats app group
@timorleste1323
@timorleste1323 2 жыл бұрын
Let me join thnks
@Ryan-xf3zi
@Ryan-xf3zi 2 жыл бұрын
mate you shouldnt be upgrading the circuit breaker unless you upgrade your supply mains. The system is designed for a 16A circuit breaker. you could possible overload line and cause a fire.
@leckyjake
@leckyjake 2 жыл бұрын
the main line is 440volts/3P/ 32 Amperes. fyi
@Ryan-xf3zi
@Ryan-xf3zi 2 жыл бұрын
@@leckyjake the system has 16A breaker on it for a reason, if it’s pulling more than 16A the motor is trying too hard. This is early signs of motor failure
@kabarotv6591
@kabarotv6591 2 жыл бұрын
As per manual, the starcool minimum current rating is 16 Amperes and at maximum cooling capacity it is 18 Amperes. They started setting the unit at 16 A due to the demands., the vessel socket is rated at 32 Amperes so in papers if the unit is rated at 18 amperes and you need to use the splitter box to supply 2 containers, that would be 36A (again at least in papers), so to match it they reduce the breakers from 18 A to 16 Amperes only. Normally starcool will not evem draw 16 A of current, that is of the cargo inside was precooled before they put inside the container. If precooled the compressor will only run at 60 hz which will reduce the current it draws., but for the hotstuff Compressors are eveb running more than 100hz, the maximum is 110hz. Definitely that 16A will not be enough. Nice troubleshooting though.
@ElektrikaCo
@ElektrikaCo 2 жыл бұрын
@@kabarotv6591 Thanks for the info. It makes sense now. Is there a way to limit maximum frequency like on a VFD?
@jovethcabresos3825
@jovethcabresos3825 2 жыл бұрын
I think 18 bar is to much that's why tripping
@JojanJojan-r7o
@JojanJojan-r7o 12 күн бұрын
Change circuitbreaker
GENERATOR 24 VOLTS LOW INSULATION TROUBLESHOOTING
10:06
leckyjake
Рет қаралды 19 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
BOW THRUSTER HIGH VOLTAGE TROUBLE | MARINE ELECTRICIAN
9:44
leckyjake
Рет қаралды 222 М.
Magnetic Brake Troubleshooting
8:41
leckyjake
Рет қаралды 24 М.
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 77 М.
Measuring conducted emissions with LISN
19:44
イチケン / ICHIKEN
Рет қаралды 1,1 МЛН
Homemade Autocascade Refrigeration System (plus Anhydrous Ammonia)
15:57
Hyperspace Pirate
Рет қаралды 118 М.
24VOLTS EARTH FAULT BURNT 2 POWER SUPPLIES
10:30
leckyjake
Рет қаралды 25 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН