Renogy Rover 40 Amp 12V/24V DC Input MPPT Solar Charge Controller

  Рет қаралды 44,166

JIUJITSU2000

JIUJITSU2000

Күн бұрын

#renogy #mppt #solar #charge controller
In this video I'll take a look at the Renogy 40 amp Rover MPPT Charge Controller. Enjoy!
www.renogy.com/rover-li-40-am...
www.amazon.com/Renogy-Charge-...
Description
Meet the newly redesigned 40A Rover MPPT Charge Controller. This smart charge controller is capable of conveniently self-diagnosing itself in the event of an error and can be used with the Bluetooth Module, Renogy BT-1. By pairing the Rover with the BT-1 and the DC Home app through Bluetooth, users can monitor and adjust their solar system straight from their phones. The Rover was also built tough with a die-cast aluminum exterior which allows for safe heat dissipation and general protection from wear and tear.
If you have any questions regarding this product, please call us at 1 (909)287-7111 or email support@renogy.com.
Key Features
Automatically detects 12V or 24V DC system voltages. Compatible with various Deep Cycle battery options: Sealed, Gel, Flooded, and Lithium.
Innovative MPPT technology with high tracking efficiency up to 99% and peak conversion efficiency of 98%.
Electronic protection against reverse polarity, overcharging, over-discharging, overload, short-circuiting, and reverse current.
LCD screen and multiple LED indicators for displaying system operation information, customizable parameters, and error codes.
Features diverse load control; also capable of charging over-discharged lithium batteries.
Die-cast aluminum design allows for efficient heat dissipation.
RS232 port to communicate with BT-1 Bluetooth module.
---------------------------------------------------------------------------------------------------------------------------------------------------------
PLEASE SUBSCRIBE and WATCH
Vanjitsu:
/ @offgridtinylife
Donations for Jiujitsu2000: www.paypal.me/jiujitsu2000
Want to contact me? jiujitsu2000@yahoo.com
I wear an XL t-shirt
Olight Affiliate link:
ttps://olight.idevaffiliate.com/idevaffiliate.php?id=119
Please use my discount code “JIUJITSU2000” for a discount
Newpowa Solar Affiliate link:
newpowa.com?sca_ref=841975.vDnA8BgjDa
Please use my discount code “JIUJITSU2000” for a discount
5% off on full priced products
Minimum purchase of $100.00
Applicable: store-wide except on sale products and gift cards

Пікірлер: 121
@cmhighway6215
@cmhighway6215 2 жыл бұрын
Finally someone that can explain this unit in layman terms. Thanks.
@bernadettetibazi9969
@bernadettetibazi9969 2 жыл бұрын
WoW! Thank you so much! I wrote everything down and saved the video. Excellent job! Now I don't feel over whelmed.
@zekearchuleta6061
@zekearchuleta6061 2 жыл бұрын
Thanks, now I understand my controller, Thought I'd need my son's help but you explained so well, I'm going to be bragging bout how simple it is. Awesome Thanks for sharing ! Blessings🙏😎
@jimlawson2449
@jimlawson2449 2 жыл бұрын
Skip to 5:15 - no need to learn how to unbox and mount... Lots of great info for those that want it, but much repetition though
@lawrencedavidson6195
@lawrencedavidson6195 2 жыл бұрын
I just got the Rich Solar 20amp controller and its working well for me. Nice video, thanks and greetings from sunny Jamaica.
@ScottyMaxx22
@ScottyMaxx22 2 жыл бұрын
Great video!! Exactly what I was looking for!! Thank you!!
@easydiy224
@easydiy224 2 жыл бұрын
New subbie. Very helpful video. I'm using the Renogy Rover Li 40. Thank you. 👍
@fetishproducer7798
@fetishproducer7798 Жыл бұрын
Awesome video, I am new to solar, so I purchased the package deal panels, controllers everything but the battery and inverter from Renogy, I was able to figure it out on the fly except for the controller controls. Awesome video in explaining how the controls work. Thank you!!!
@jiujitsu2000
@jiujitsu2000 Жыл бұрын
Thank you!
@darrellfort1668
@darrellfort1668 2 ай бұрын
thank u sooooooooooooooo much for doing this video sir! may GOD bless you and your family, amen
@Mike-01234
@Mike-01234 Жыл бұрын
Don't mount the box until you have looked at how the terminals work. I got confused was turning the screw left almost busted out the plastic. I didn't look up under there and turn it see how it worked. There is a metal tab that screws up grabs the wire. I receemoned if you can screw all the wires in first while its flat before you mount it on the wall.
@kelvinjohnson3949
@kelvinjohnson3949 Жыл бұрын
Ybor 7u r
@emiloles9873
@emiloles9873 3 жыл бұрын
Thank you very informative
@Desertphile
@Desertphile 11 ай бұрын
Thank you. I do not understand why people spend more for Renogy when similar chargers cost less.
@ironian24
@ironian24 7 ай бұрын
its because they are great quality with far more features and power than the cheaper ones. in my opinion there is only 2 real contenders for my van power, Renogy or Victron, I started with Renogy so I carried on with it through the whole of my electric build, I am very impressed with the build quality, the plug and play side of it all, the easy to follow instructions, the power production, the ease of use, with either apps or panels it's easy to see what your electronics are doing.
@Desertphile
@Desertphile 7 ай бұрын
@@ironian24 ; Thank you. At the moment my go-to for solar power devices is Demuda, which is popular in the EU, UK, and elsewhere; I do not know why Demuda is not popular in the USA.
@theusconstitution1776
@theusconstitution1776 7 ай бұрын
My everything is RENOGY❤️
@CharlesMaynard-kj8wd
@CharlesMaynard-kj8wd Ай бұрын
It is a clone of the SRNE unit.
@BrentCraig7
@BrentCraig7 2 жыл бұрын
Thank you for your instruction.
@tandrewl1
@tandrewl1 3 жыл бұрын
Excellent, and thank you.
@jiujitsu2000
@jiujitsu2000 3 жыл бұрын
Glad you enjoyed it!
@miltontaylor5466
@miltontaylor5466 Жыл бұрын
Excellent help. Thanks
@deanbrennan1976
@deanbrennan1976 Жыл бұрын
Great video thanks 👍
@luzrucci5534
@luzrucci5534 Жыл бұрын
THANK YOU! I had the wrong battery type since I got it!
@jiujitsu2000
@jiujitsu2000 Жыл бұрын
Thank you!
@ArizonaKid
@ArizonaKid 3 жыл бұрын
Good review buddy see ya on the next one
@ironian24
@ironian24 7 ай бұрын
do you need breakers or fuses from the solar panels and to the battery? or is there an internal fuse on this unit? I just installed mine with no fuses because i thought there was an internal fuse, I have 2x 200 watt panels going through the 40amp mppt unit then to the 200amh lithium ion battery, all renogy.
@Rabbitpondoffgrid
@Rabbitpondoffgrid Жыл бұрын
I thought you explained that all very well.
@MiscMitz
@MiscMitz 3 жыл бұрын
Excellent info Skeet. That thing is smarter than me. Lol
@jiujitsu2000
@jiujitsu2000 3 жыл бұрын
Thank you brotha! It's smarter than me too... lol I'm going to do another video similar to this one. I didn't like how dark it looked.
@jayt838
@jayt838 2 ай бұрын
Do you know what happens to the controller if the battery power is lost do to the battery shutting down or disconnected unexpectedly ? If this needs to be powered first from the battery.
@penelopegreenland3537
@penelopegreenland3537 2 жыл бұрын
Trying to decide if I should hook my 3, 100watt panels in parallel when using a renogy rover charge controller. I am in an area with intermittent shade. I ran it on two panels in series last year and did not get enough stored energy to run appliances on cloudy days. Awesome explanations!
@MarkWilliams-ix1qf
@MarkWilliams-ix1qf Жыл бұрын
Parallel if you think shade is likely. You have more wire loss, but not a shutdown as with series.
@robertsullivan9501
@robertsullivan9501 Жыл бұрын
on the home screen what should the battery voltage read and what mode tells you the solar panel is charging the battery and how much, i am new to this stuff, also if using two deep cycle batteries in parellel should you charge them both before using
@garythomas1248
@garythomas1248 10 ай бұрын
That was a good video. The book that the charge controller comes with is almost useless. And I have three 60 amp charge controllers the same brand so I am familiar with them
@earlshaner4441
@earlshaner4441 3 жыл бұрын
Hi from Syracuse NY
@jiujitsu2000
@jiujitsu2000 3 жыл бұрын
Hello there!
@kisah.nadzwan
@kisah.nadzwan Жыл бұрын
hai. I have a question. I already installed renogy Rover 40amp MPPT to my RV with 12V GEL battery. the problem is. my charger wont charge my battery even though my battery is under voltage. what caused?
@timkempowski7012
@timkempowski7012 Жыл бұрын
Do you know the max amp draw from the dc load? Mine trips and I’m trying to pull peak 10 amps which I don’t think is that high for DC, so yeah low draws on the load out side. Great video just wish the lighting was better. Thanks for the video
@coongoola
@coongoola 2 жыл бұрын
I have the same controller. Can't understand why there isn't a backlight display on the screen. Crazy.
@FromMetayou
@FromMetayou 2 жыл бұрын
I prefer no backlight because it is annoying otherwise as I have my controller on show over bed area so wouldn't be able sleep in my tiny camper lol
@earlshaner4441
@earlshaner4441 3 жыл бұрын
I'm volunteering at the polls today my friend
@jiujitsu2000
@jiujitsu2000 3 жыл бұрын
Excellent!
@wellnesspathforme6236
@wellnesspathforme6236 Жыл бұрын
If voting mattered, the Money Power wouldn't let you do it. ;-)
@earlshaner4441
@earlshaner4441 Жыл бұрын
Yes my friends
@headbangerministries
@headbangerministries 2 жыл бұрын
Hi I have the same Renogy controller and getting ready to install it with my inverter. Very informative video and learned more about my controller so I know whats going on. One question though, I bought one lead acid battery and was told to watch it not go below 1/2 charge. I believe the controller has the ability to tell me on teh screen if its at a certain charge level or bars or do I need to buy a separate battery monitor, would not be a bad idea to buy one when I have more money though.
@GHE2005
@GHE2005 2 жыл бұрын
So if I plug in a iCeco 20 frig is that considered a heavy load? I'm not understanding "a load"? Did I see u plug some socks into your load? R they USB sockets or outlets? Thank u for all the details explanation.👍🏾 I don't hv much knowledge about controllers.
@livinglif3365
@livinglif3365 8 ай бұрын
What setting is used for deep cycle pure calcium lead alloy 12 v batteries?
@HammVan
@HammVan 10 ай бұрын
My controller is not reading the solar panel. Trying to figure out how to trouble shoot. Checked plugs all connected
@jiujitsu2000
@jiujitsu2000 10 ай бұрын
Fuse?
@HammVan
@HammVan 10 ай бұрын
@@jiujitsu2000 I ended up replacing with a new charge controller just now and working like a charm.
@jiujitsu2000
@jiujitsu2000 10 ай бұрын
@@HammVan did you figure out what was wrong with charge controller?
@JohnKut
@JohnKut 2 жыл бұрын
I have one question. I recently installed my Renogy Rover 40A, I was wondering if there is any setting/switch to Run/Stop solar charging? or is my only option to install a kill switch in between controller and the battery? (No load plugged in)
@jiujitsu2000
@jiujitsu2000 2 жыл бұрын
Switch
@jessefabbro2158
@jessefabbro2158 Жыл бұрын
i hope you didnt use a switch between the battery and controller that will likely fry the controller at some point. you want the switch between the panels and the controller, if you want to stop charging.
@JohnKut
@JohnKut Жыл бұрын
@@jessefabbro2158 oh shoot. I used between the battery and the charger. thanks for the warning. will chage it.
@animallovefest143
@animallovefest143 2 жыл бұрын
Can you further explain the "Boost" & "Optimization" mode, please? Thanks for the info, you really helped me understand my charge controller. Christina & The Animal Love Fest :)
@jpmo82
@jpmo82 6 ай бұрын
hi, to main questions, unit have backlight? how reset? thanks.
@dylanstuckless5669
@dylanstuckless5669 11 ай бұрын
Is there a reason when i set it to the 24v that it does stay charging arlt 24v?
@earlshaner4441
@earlshaner4441 3 жыл бұрын
Happy birthday brother
@jiujitsu2000
@jiujitsu2000 3 жыл бұрын
Thank you brotha! Blessings!!!
@lawrenceminnear2705
@lawrenceminnear2705 2 жыл бұрын
I have 4 x 100 watt, 6 lead acid deep cycle batteries less than 6 months old. I am using the Rover controller and I can never get the charge more than 65% full sun in Texas. Whan can I be doing wrong?
@jiujitsu2000
@jiujitsu2000 2 жыл бұрын
I read your other comment too. It depends on how your panels and batteries are wired.
@boscodog4358
@boscodog4358 2 жыл бұрын
What is the equation to figure size Amp hour battery needed to supply a 5ooo but ac for 8hr run time.
@user-fw6eg3hc8f
@user-fw6eg3hc8f 2 жыл бұрын
Easy it's called a Generator
@cleangreen2210
@cleangreen2210 2 жыл бұрын
I am trying to get this same model to recognize my 24v system, with two lithium batteries wired in series. I will not allow my to boost the settings for 24v. Any help?
@jiujitsu2000
@jiujitsu2000 2 жыл бұрын
Yes,,, I'm actually doing a video that will release soon showing how to setup this charge controller... feel free to email me if you don't want to wait until next week... jiujitsu2000@yahoo.com
@cleangreen2210
@cleangreen2210 2 жыл бұрын
@@jiujitsu2000 Thanks! What it seems like now is that you have to take the settings from the battery manufacturer and divide them in half, then you change the battery type to LI and the voltage to 24 on the controllers. Renogy says this is because "sometimes" the charger controller does not recognize the 24v bank. After trying this yesterday it seemed to work, as I stopped getting low voltage errors and both batteries charged together.
@Junkie4Jesus777
@Junkie4Jesus777 Жыл бұрын
Hey bud, I’ve watched this video 3 times as I installed my rover 40 amp and I just can’t figure out why it’s always on night mode as I purchased it new and am getting 20.4 V from my panels and it’s even reading 20.4 V when I touch my meter to the panel jacks on the left hand side right next to the battery temp sensor so I know the rover is getting the juice from the solar panels but for some dam reason it won’t change my batteries because it’s always showing the little moon icon on the top left of the screen and it’s 77 degrees out without a cloud in the sky and not a single square inch of shade on either of my 8 panels as this will work on 800 watts as long as you run the batteries at 24 V in series. Do you have any ideas as to what the heck is going on or how to maybe reset the controller to factory or hell I don’t know anything? Thanks so much 🙏🙏🙏
@bradlyons7046
@bradlyons7046 Жыл бұрын
When using lithium-ion 12V battery and using the control button(s) on the controller to select 'Lithium' as the battery type, does the controller know everything else it is required to know for using a lithium-ion battery? Or is there additional programming required for the controller to work properly with a lithium-ion battery? For example, Will Prowse mentions in one of his many KZbin videos about DIY solar set-ups, that he favors the EPEVER Tracer MPPT solar charge controller, but mentions it is too complicated to program it when using a lithium-ion battery instead of a lead acid battery. Does this Renogy MPPT 40A solar charge controller have similar excess programming complexity as the EPEVER Tracer 40A MPPT solar charge controller when using a lithium-ion battery instead of a lead acid battery? When using more than one lead acid battery connected to the same MPPT solar charge controller, is more than one battery temperature sensor needed to monitor the temperature of all the batteries? Please explain what the 40A (40 Amps of current) rating of this Renogy MPPT solar charge controller refers to. For example, does it refer to the maximum number of amps it is able to control coming from the solar panel(s)? The EPEVER Tracer4215BN MPPT controller is a 40A solar charge controller and has a maximum discharge current (the discharge current to the load) of 20A, not 40A. What is the maximum discharge current of the Renogy 40A MPPT solar charge controller? 20 amps? 30 amps? Please explain what the term 'maximum discharge current' is. For example, is it the maximum number of amps (maximum amount of current) it will allow the solar powered devices to pull from the controller and / or battery? Please explain. I ask these questions for the following reason(s): I want to build a direct current 12V portable outdoor solar powered swamp cooler using two 12V, 120W, 10A automotive radiator fans wired to one or two 20A motor speed controllers (potentiometers). A person told me I need to allow for momentary surge of excess current (momentary amp surge) each time the two 12V, 120W, 10A automotive radiator fan motors power-on; however, I am wondering how much of an amp surge the fan motors will momentarily pull on the MPPT charge controller, and whether or not one or two 20A motor speed controllers wired to each fan motor will help prevent the amp surge on power-up of the two fans. The submersible water pump will be 12V, 20W, 2A, and will be wired to a toggle switch to turn on & off. I will be using four 12V, 100W, 7A portable briefcase solar panels connected in parallel which will provide 400 watts, 28 amps at 12 volts to whatever MPPT solar charge controller I end up choosing to use. I want to start out using 12V sealed lead acid batteries, and eventually switch to lithium-ion 12V batteries. For this reason, I have decided not to choose the EPEVER Tracer brand MPPT solar charge controller because it is purportedly too complicated to program when using one or more lithium-ion battery. I presume I need to choose a 40A MPPT controller instead of a 30A MPPT charge controller, but perhaps a 40A MPPT charge controller is not enough amps either for my swamp cooler. Do I need a 60A MPPT charge controller? What's your opinion? I invite anyone to leave a reply to my questions. Thank you.
@yvettestewart8002
@yvettestewart8002 2 жыл бұрын
Can you install this in the storage compartment in the front area of a travel trailer? It would be located in storage under queen bed in front of trailer. I was concerned about ventilation, but it seems people are putting them in cargo areas.
@jiujitsu2000
@jiujitsu2000 2 жыл бұрын
Absolutely!
@yvettestewart8002
@yvettestewart8002 2 жыл бұрын
@@jiujitsu2000 Thank you. That works better for me.
@jpmo82
@jpmo82 7 ай бұрын
Hi, great video, i understand that rover 40a have a maximum 100v pv input, but how many amps in the input? Thanks
@alvino9611
@alvino9611 2 жыл бұрын
What are the limitations to the "load" connections on the bottom right as to volts or amps?
@jiujitsu2000
@jiujitsu2000 2 жыл бұрын
No heavy amp draw loads. Light duty stuff like led lights, fan etc...
@ScottyMaxx22
@ScottyMaxx22 2 жыл бұрын
From what I’ve read, it’s has a max of 20amps. If you have 12v battery then it’ll have a 240 watt max.
@tompetroff
@tompetroff 8 ай бұрын
Can you set a limit to charge the batteries to only 85% and then cut off the charging?
@douglundy5755
@douglundy5755 Жыл бұрын
trying to learn how to clear the low battery error after pulling the charge down to 10.5 momentarily. The charge came right back but still showing the low battery error so do I need a reset by disconnecting the solar and...?? Anyone? Thanks. I have a 30 amp with 400 watts of solar and it works fine.
@WhimsicalCyn1
@WhimsicalCyn1 2 жыл бұрын
Can you show how it changes when you put loads on the batteries? My battery screen shows 100% all the time but when we plug something in, the discharge A and AH stay 0 but our battery capacity jumps around between 50% and 100% it makes no sense
@akauto2900
@akauto2900 2 жыл бұрын
Is your load going through the charge controller, or is it going through an inverter? To display load information, it has to be from the load output on the controller. However, it can't handle a heavy load.
@FromMetayou
@FromMetayou 2 жыл бұрын
Brilliantly explained but me being dumb would like a confirmation of which battery setting would my leisure be set at lead acid sealed ,would that be as explained under the 9
@chadkline4268
@chadkline4268 10 ай бұрын
Does Li battery type include LiFePO4?
@michaelleee3417
@michaelleee3417 Жыл бұрын
Will it let you set the parameters on a lipo battery.
@mishokorlov
@mishokorlov 2 жыл бұрын
What is max PV voltage?
@macrobionic
@macrobionic 2 жыл бұрын
Can I connect a 12v power source into the solar panel input to charge my battery at night?
@alvino9611
@alvino9611 2 жыл бұрын
I'm guessing in the load connections you could wire something up. I'm curious as to what the limitations of those connections are as well.
@user-bi3ic7ny3c
@user-bi3ic7ny3c Жыл бұрын
Can im put 90 VoC on this controler or not ok
@johnmerton3630
@johnmerton3630 2 жыл бұрын
my pv input voltage shows 15.5 volts but if i disconnect the controller the pv voltage is 20.6 volts Why?
@roginutah
@roginutah 2 жыл бұрын
Manual says load outlet's current is 20A. So 20A at 12V = 240 watts. Like your car's cigarette lighter/outlet, right?
@terryj-londonontariocanada4605
@terryj-londonontariocanada4605 Жыл бұрын
I need to confirm that as well, hopefully someone replies.
@SuperStar-nz5xy
@SuperStar-nz5xy Жыл бұрын
yes. its not designed to power anything larger.
@Jhovan33
@Jhovan33 3 жыл бұрын
With all the technology we have in the world, we still have cryptic codes to tell us what's going on? Why not just have a display that can give you the message of the error rather than a code?
@jiujitsu2000
@jiujitsu2000 3 жыл бұрын
True! The price may be higher?
@GregoryBoysHomestead
@GregoryBoysHomestead 10 ай бұрын
Can you do this video again, but with the lights on?
@lawrenceminnear2705
@lawrenceminnear2705 2 жыл бұрын
last comment....4 x 100 watt panels
@ramonmirabal101
@ramonmirabal101 Жыл бұрын
I just buy one 40 amps from amazon is showing code E3, not Tec support, I will return and get victron before my 30 days return window expire.
@Suckmesideways420
@Suckmesideways420 2 жыл бұрын
can the 40 amp charge controller in this video handle six 100 watt panels?
@jiujitsu2000
@jiujitsu2000 2 жыл бұрын
What voltage? 12, 24??
@Suckmesideways420
@Suckmesideways420 2 жыл бұрын
@@jiujitsu2000 12 volt
@jiujitsu2000
@jiujitsu2000 2 жыл бұрын
@@Suckmesideways420 The Max that I would run on this charge controller is 480 Watts. If you want to run 600 Watts of solar you need a 50 amp charge controller or larger. 60 amp charge controllers are easy to find.
@Suckmesideways420
@Suckmesideways420 2 жыл бұрын
@@jiujitsu2000 ok cool. Thank you for the advice
@jiujitsu2000
@jiujitsu2000 2 жыл бұрын
@@Suckmesideways420 🤙
@AntonioRey4
@AntonioRey4 Жыл бұрын
How about posting a written version of the video
@eddygoodwin7089
@eddygoodwin7089 2 жыл бұрын
How much was that controller?
@narrowboatj.j.crooksfristb7451
@narrowboatj.j.crooksfristb7451 2 жыл бұрын
These systems have developed a long term fault they show a E3 code and stop loads over 2 amps going through the load side but reneogy will not replace the system with this fault
@TonyLing
@TonyLing 3 жыл бұрын
2:39 RS232 is a serial port
@jiujitsu2000
@jiujitsu2000 3 жыл бұрын
Thank you!
@SheridanAtwood-bd3ks
@SheridanAtwood-bd3ks Жыл бұрын
I just opened my new Renogy Rover 40 MPPT and it is a piece of CRAP!!! THE INPUT ACCESS POINTS ARE COMPLETELY FREE FLOATING INSIDE THE UNIT AND MAKE IT IMPOSSIBLE TO MOUNT YOUR WIRES! Removing the cover to explore the issue reveals a series of input mounts that are literally loose inside and magnetized and repelling each other laying loose in the shroud. They do not stay put to allow cable mounting. What were they thinking? Did someone on the assembly line get pissed off and just throw the parts inside and close the box up? Almost $200 down the drain!
@user-fw6eg3hc8f
@user-fw6eg3hc8f 2 жыл бұрын
If you're gonna make a video...turn lights on so we can see...everything is dark and barely visible
@h3bysuzanne184
@h3bysuzanne184 2 жыл бұрын
Video is too dark, can’t see it very well
@jiujitsu2000
@jiujitsu2000 2 жыл бұрын
True, thank you. I'll make a better version in the future
@tcb069
@tcb069 2 жыл бұрын
put a light on screen , hard to see
@netposerx
@netposerx 2 жыл бұрын
This is one of the worst interfaces. So confusing when they show a tiny battery icon as if you can tell the difference. You have a massive screen that's mostly blank. I don't get it.
@Coopdundee
@Coopdundee 2 жыл бұрын
Too dark
@bbmotorhomes9587
@bbmotorhomes9587 2 жыл бұрын
Instructions in the dark we cant see anything
@jussikankinen9409
@jussikankinen9409 7 ай бұрын
Educate so no need hunting new korona
@mainelivin3699
@mainelivin3699 Жыл бұрын
Can't see nothing on this video too dark
Renogy Rover PG MPPT Solar Charge Controller
20:58
Adam Welch
Рет қаралды 76 М.
ОСКАР vs БАДАБУМЧИК БОЙ!  УВЕЗЛИ на СКОРОЙ!
13:45
Бадабумчик
Рет қаралды 4,2 МЛН
I CAN’T BELIEVE I LOST 😱
00:46
Topper Guild
Рет қаралды 103 МЛН
KINDNESS ALWAYS COME BACK
00:59
dednahype
Рет қаралды 129 МЛН
How to Set Battery Setting on Renogy Rover 60 Amp Controller
16:11
Gary Spillane
Рет қаралды 1,3 М.
12v Solar Charge Controller Buyers Guide - Beginner Friendly!
20:28
DIY Solar Power with Will Prowse
Рет қаралды 2,1 МЛН
The Top 9 Lithium Battery Mistakes for Van and RV Power Systems
24:50
How to connect the LiTime 60amp BLUETOOTH MPPT solar charge controller.
16:54
Gear & Gadget Reviews
Рет қаралды 1,2 М.
Renogy Rover Li 40 amp MPPT Solar Charge Controller Overview
11:03
DIY Homestead Projects
Рет қаралды 58 М.
SAVE Thousands - Build your own home solar battery backup!
21:17
Projects With Everyday Dave
Рет қаралды 218 М.
😁💸 @karina-kola
0:16
Andrey Grechka
Рет қаралды 6 МЛН
谁能救救小宇宙?#火影忍者 #佐助 #家庭
0:43
火影忍者一家
Рет қаралды 18 МЛН
Mission Success #funny #shorts #comedy
0:12
BD Vibes
Рет қаралды 65 МЛН
Слепой перехитрил свою жену😳
1:00
Kino_sh
Рет қаралды 9 МЛН
Mission Success #funny #shorts #comedy
0:12
BD Vibes
Рет қаралды 65 МЛН