Awesome ur teaching way is very good and easy to understand And the good thing is u explain everything without playing any stupid music I like ur way to teach Keep It up.
@shafqatmehmood62335 ай бұрын
Nice explanation sir, ❤
@muhammadrafique62853 жыл бұрын
Very good explanation Masha Allah
@ashishvitekar34744 жыл бұрын
Very nice explain and informative video's keep it up
@Amjad_Ali77804 жыл бұрын
Assad bhai very Well done
@NKELECTRICALDOST Жыл бұрын
Extremely Good explanation
@muhaamdtahirismail14784 ай бұрын
Very well Explain Thanks
@aamirawan79983 жыл бұрын
You should've used the word "torque". To be precise "mechanical torque" of the prime mover (engine). When reverse power occurs the speed won't drop when DG is running parallel with other DGs or an infinite bus but rather the "mechanical torque" is dropping which then drops the active power of the generator then it goes to 0 then negative. When it goes in the negative region it means the generator is now a motor which is being fed by the bus. Good try though!
@sanjeebbadaik2912 Жыл бұрын
Very good explanation , thaanks
@Sailor1864 Жыл бұрын
Very Nice Explain Bhaijaan
@rrajkir3 жыл бұрын
Very well explained sir.. thank you..
@muhammadrazaaslam45434 жыл бұрын
Very informative knowledge. Sir plz plz plz aik video power mood,speed mood,isocho,island, droop mood ect per bi video kerian
@AsadElectrical4 жыл бұрын
Ok noted
@syyednoor2774 жыл бұрын
Masha Allah.. 🤲🤲🤲
@Vinodsatkar3 жыл бұрын
too good explanation..
@muhammadshoaibkhan47504 жыл бұрын
Asad bhai how to improve pf in DG side ,not in field by using pfi , I have 5 DG 3512 working in perallale ,sometime in which one genrator start decreasing .62 pf How to improve
@AsadElectrical4 жыл бұрын
I will make video on this topic
@haseebbaloch8454 Жыл бұрын
Sir Kindly make a video about this topic relay setting how to find all detail thanku sir
@mahmoudkamal3119 Жыл бұрын
english language where or arabic?
@pathankhan56023 жыл бұрын
Aap ka sab video bohat Kam aati hai
@burhanazeem52584 жыл бұрын
Good information
@UmarIkramRajput4 жыл бұрын
Assalamu alaykum Asad bhai aapane bahut acche tarike se concept clear Kiya hamare pass same ISI Tarah Ke 5 generators hai unme se ek generator per yah problem hai ki Jab Ham usko start karte hain to load uska -20 kilowatt Tak Chala Jata Hai Aur takriban Ek 2 minut ke andar andar load Dobara se uska positive ho jata hai aur wo load Lena Shuru kar deta hai yah kya problem ho sakti hai please advise Kariye ga. Aur Agar Mumkin ho sake to apna WhatsApp number bhi share kar dijiyega aap ka bahut bahut Shukria
@AsadElectrical4 жыл бұрын
W,salam. Agar fuel filters sab ok hain aur mechanically koi problem nhi he to speed controller ki settings check karni paregi.
@faizanwar68332 жыл бұрын
backfeeding same h kya
@balubhoya92802 жыл бұрын
Good experience sir
@uzziesoul4 жыл бұрын
Sir ager Engine running main hai aur indication ay kay cb Tripped 1328 ki warning ay to is ki kya reasons hai..
@AsadElectrical4 жыл бұрын
Circuit breaker k auxiliary contacts me problem honay ki waja se bhi askti he warning.
@praneshrai8342 жыл бұрын
We have 3 nos CAT 3516 genset Synchronised...2 Mechanical and One electrical gensets...All 3 EMCP upgraded to 4.2...after that one electrucal model CAT 3516 having reverse power problem only while removing load from genset...what might be the problem?!
@AsadElectrical2 жыл бұрын
Please make sure programming is same for all EMCP's
@praneshrai8342 жыл бұрын
@@AsadElectrical Well noted bhai
@rizwanarif27223 жыл бұрын
Sir plc or scada sikhna hai please
@soumya22213 жыл бұрын
Sir reverse power ka turbine pe kya effect ata hai??.. Kon se stage pe prob ata hai
@muhammadrazaaslam45434 жыл бұрын
Sir, Kia reverse power honey say Engine electrical power say power produced keray ga??? Plz explain Simply sir motor reverse power main output per mechanical power day gi is duron crankshaft kis power say move ho gi
@AsadElectrical4 жыл бұрын
Question clear kardain
@AsadElectrical4 жыл бұрын
Jab Generator Motor Ban jata he to wo Dosray generators ki supply se rotate hota he jiski waja se dosray generators par load barh jata he. isi liye reverse power case me suddenly breaker open hona zarori he. Yani Generators ki supply is generator me ayegi aur jab Alternator rotate karega to engine ki crankshaft bhi uskay sath attach honay ki waja se rotate karegi aur ye problem sirf load sharing me hi ata he single generator me nhi
@muhammadrazaaslam45434 жыл бұрын
Thanks sir
@sujoyghosh74683 ай бұрын
Sir speed Kam hone par frequency Kam nahi hoga ?
@ramzanchramzanch63444 жыл бұрын
Good work
@pkgupta3243 жыл бұрын
Gen reverse power aa raha hai mere yaha ke Generator me KOEL make 500 KW hamare pas sirf ek DG hai to problem kaha ho sakta hai
@AsadElectrical3 жыл бұрын
single generator me actual problem reverse power nhi hota. Genset control panel ki wiring aur programming check krni pregi CT/PT connections and rotating diodes AvR etc
@shaffaybinusama13724 жыл бұрын
Gen.motor set 1 &2 main say 1 no. Ke supply off ho Gaye.set 2 ke reverse power relay actuate ho gae.reverse power relay set 1 actuate nhe hoe. We find reverse connections at relay.
@shaffaybinusama13724 жыл бұрын
Now we find reverse power minimum setting at relay i-e 6.4%.76A.,(500kva) Is this relay ok or v have replace it.
@shaffaybinusama13724 жыл бұрын
Reply if interested.
@AsadElectrical4 жыл бұрын
Please make sure all connections are as per drawing
@malikyounus14 жыл бұрын
Please make video on DIEF controller
@mdtecnicalmoin98529 ай бұрын
Vrv unit hai usme ye revers relay lga hai to red indicator aata hai to kya problem hai
@nabeelsaeed39982 жыл бұрын
Mera generator off tha, leken uska wire 220v walay socket mai laga hua tha, JESE hi light ayi to current 220 generator Mai Gaya 10 second ke liye AUR slow voice arahi thi, Mene foran plug hataya. Kia is cheez se winding jal Gayi hogi mere generator ki? Small generator hai mere pass.
@AsadElectrical2 жыл бұрын
Ab ap start kr k check krain. Hosakta he sahi ho
@nabeelsaeed39982 жыл бұрын
@@AsadElectrical start Nahi ho Raha hai abhi
@AsadElectrical2 жыл бұрын
@@nabeelsaeed3998 agar winding kharab ho phir bhi start hona chahye
@nabeelsaeed39982 жыл бұрын
@@AsadElectrical Mene randomly OLX se generator repair walay Ka number Nikaal Ker masla bataya to kehne lagay motor Gayi iski AUR 12,000 Ka kharcha ayega. Ab Apne pehchan walay ke pass leker jaonga aaj, then let's see
@AnkitKumar-fz4ob2 жыл бұрын
Kya Panel se reverse power ki possiblty hai
@AsadElectrical2 жыл бұрын
yes
@Darim_0013 жыл бұрын
Asad bhai we r facing problem Everything is we tested but genset triping on reverse power
@AsadElectrical3 жыл бұрын
You need to test generator separately on load. If single genset will run ok then some problem in synchronizing/ load sharing system
@praneshrai8342 жыл бұрын
Hai...I had encountered one problem today...2 Perkins generator on Synchronization...Perkins 4012 engines...one of the engine had low power...customer replaced Governor...Now in Synchronization no problem but whenever Generator 1 load removed and when it enters cooldown mode Reverse power alarm comes...when we reset the alram it goes
@AsadElectrical2 жыл бұрын
Seems like some setpoints need to adjust from controller
@praneshrai8342 жыл бұрын
@@AsadElectrical Ok thank you
@birendramandal19922 жыл бұрын
Do generator mein se koi ek generator chalta hai ya usse band karo ya ise band karo lekin do generator sath mein nahin chalta
@bilalsarfaraz785710 ай бұрын
Ager sirf do engin chl rahy ho pir kasay reverse power ko controll kary sit
@equipmentdiagnostictest59354 жыл бұрын
Absolutely right sir.
@accousticpawan86383 жыл бұрын
Thnks sr
@azharaziz59392 жыл бұрын
Sir if reverse power generates through the load side, what we will do for protection?
@AsadElectrical2 жыл бұрын
In both cases Reverse power detection relay should be used. But reverse power mostly comes through generator side,
@pakistanifoods45254 жыл бұрын
Mashaallah
@wajiatariq87784 жыл бұрын
GOOD
@Aman-Engineering-Academy3 жыл бұрын
Max.generator current kyoun aata hai, aur iski kharabian kya hosakti hain
@Aman-Engineering-Academy3 жыл бұрын
Jawab nahen dya aapne
@Shahlazaidi74 жыл бұрын
Nice
@birendramandal19922 жыл бұрын
Sir do generator hai usmein se ek generator start karne par dusra generator reverse power kyon dikhta hai
@AsadElectrical2 жыл бұрын
dono generator ki frequency aur voltage same hona chahye
@dulalmiah20212 жыл бұрын
Thx
@birendramandal19922 жыл бұрын
Please sir reply karo mujhe aapke help ki jarurat hai
@mtariqaa3939 Жыл бұрын
Two genset synchronize but both kw meter reading 0 to 20 kw up and down. first genset 1 goes to 35 kw Then genset 2 goes to 15kw genset 1 goes to 15 kw genset 2 goes to 35 kw
@choudharyrk24043 жыл бұрын
Mera Dynamo Jal gaya kyo
@AsadElectrical3 жыл бұрын
many causes
@birendramandal19922 жыл бұрын
Lekin sir dono generator chalta hai sirf ek sath mein nahin chalta
@sachidanand69523 жыл бұрын
Reverde power relay details please
@shaukat3234 Жыл бұрын
Generator is running alone without synch. Dse8610 showing -ve power and trip after load increase upto 150 amp
@AsadElectrical Жыл бұрын
Wrong Connection or wrong programming
@birendramandal19922 жыл бұрын
Yadi sir ek generator chalo to chalta hai lekin do generator sath mein nahin chalta
@TalhaAbid-e7m10 ай бұрын
❤
@arun48462 жыл бұрын
👍
@birendramandal19922 жыл бұрын
Ek number generator start karo to do number band hota hai do number start karo to ek number band hota hai dono mein se jo bhi generator band hone per yahi likh raha hai BOC reversepower