No video

Rheem Gas Furnace Circuit Board Replacement

  Рет қаралды 57,933

Anti DIY HVAC

Anti DIY HVAC

Күн бұрын

Пікірлер: 114
@nfcooling
@nfcooling 5 жыл бұрын
I appreciate your comments about focusing on doing my own work to the best of my ability and not worry about what the last guy did. Great work on that control board and showing how to simplify the wiring cluster.
@bodudas8346
@bodudas8346 Жыл бұрын
Thank you !!!! Exactly what I needed --- a comprehensive all inclusive how to video, step by step for this old man who was not going to buy a $4500 furnace when it is just a board that needed replacing... your manner of explaining is wonderful - have a great day.... bo
@macmac3374
@macmac3374 5 жыл бұрын
I always take pics before I do anything electrical. Helps me out alot
@DanDeeg78
@DanDeeg78 5 жыл бұрын
I always take a picture beforehand, just in case. Good video man!
@Heavy_metal_rulez
@Heavy_metal_rulez 5 жыл бұрын
I always liked how easy Rheem made their panels to take on and off, in this particular style of course. Who ever installed that system did a good job
@Monicamae100
@Monicamae100 3 жыл бұрын
I just want to take a minute to thank you for doing this video. You saved me $4800.00. I purchased a board online for $165.00 and installed it myself! I had received a quote of $4800.00 to replace the furnace or $850 to replace the board with no guarantee that it would work on my 20 year old furnace. Your video gave me confidence to replace this myself and I am very grateful! I bought an extra board just incase as a backup as I am worried that they may stop making the part. Thanks again you made a great impact!
@DanBlackRacing
@DanBlackRacing Жыл бұрын
For the thermostat wires I usually take a piece of tape and run across the front and back of the whole group to keep them in their current position and also take a picture beforehand or write it down to make sure everything goes back in the same place.
@TheWoodman064
@TheWoodman064 5 жыл бұрын
You are one very awsome perfectionist! Thanks for being such a great example to the rest of us techs! Virtually every one of your videos I find some new nuggets! You have another committed viewer here! 64!
@keysthinking
@keysthinking 5 жыл бұрын
We were born to fix things,and it is wonderful that we get paid for it. A/C and appliances for over 44yrs
@TheWoodman064
@TheWoodman064 4 жыл бұрын
I am so glad you heard me when I said the red wire went to the right! Great job!
@joshuajunkins2811
@joshuajunkins2811 5 жыл бұрын
I replaced the same board for the same reason last week. I also used the old stand offs. Great video!
@skyewrighter3493
@skyewrighter3493 4 жыл бұрын
rheem makes pretty good equipment my rheem furnace was put in in 2014 still running strong after 6 years of service im pretty impressed with rheem quality
@corazonsalsero27
@corazonsalsero27 5 жыл бұрын
I love your videos, very well explained and so professional... keep it up the good job!!!
@josepenado6068
@josepenado6068 2 жыл бұрын
Ilove the way you explains the process for replacement thanks very helpful
@Dave-us6yu
@Dave-us6yu 5 жыл бұрын
Your kind of the Bob Ross of HVAC!!!
@integrity5264
@integrity5264 4 жыл бұрын
great video, like all your videos very educational for both trade and keeping your integrity, thank you
@DanDeeg78
@DanDeeg78 5 жыл бұрын
Love the sound of a gas furnace fire-up. Had it as a ringtone for a minute, but I missed a lot of calls.
@charlesmalinoski6325
@charlesmalinoski6325 5 жыл бұрын
An empty (Clear Barrel) Bic Ink Pen,slipped over those mounting tabs. For the board often works really well too, for board removal. Little trick I learned. Keep one in my go to bag. Like your videos!! Much appreciated 👍
@embeddedgirl
@embeddedgirl 4 жыл бұрын
Rheem guy here, M1 and M2 next to the speed taps on the board are your deticated park terminals. Have a good day Ted
@kevincopley7783
@kevincopley7783 Жыл бұрын
Thank you for taking the time to help the public with this video. I was a little nervous about the whole thing, but I’m confident I can do it now! Thank you again good sir!
@pinkposey8134
@pinkposey8134 Жыл бұрын
This is a really good video. Thank you for showing the fuse. In my case, it was the 3 amp fuse that blew. Makes sense as in my case was out redressing wires outside to the AC unit and di not turn off the power. Can understand from my AC configuration how the fuse blew back at the board based on what I was doing, and everything worked prior to my outdoor work. Made sure the fuse socket was 0 ohms. The fuse measured open. It is a purple 3 amp ATC or ATO auto fuse.
@James_Bowie
@James_Bowie 5 жыл бұрын
Re standoffs, I like Steve Lav's solution: push on them with the empty stem of a Bic biro.
@partshnc
@partshnc Жыл бұрын
The method was well explained by the presenter, who also offered crystal-clear demonstration that made it simple to follow along. We provide quality Rheem Gas Furnace Circuit Board and other Rheem Ruud gas furnace parts.
@ethelryan257
@ethelryan257 3 жыл бұрын
Your attention to detail does make a difference.
@skizzo657
@skizzo657 Ай бұрын
i was looking for something to fall asleep to. people tinkering on stuff does the trick.
@tombalboni2143
@tombalboni2143 5 жыл бұрын
Thank you for leaving about a 1/16" of visible wire on the tstat screw connections!. Nothing irritates me more than seeing the screw terminals clamped down on nothing but insulation...
@josiahpierson3636
@josiahpierson3636 5 жыл бұрын
Something to note too ted is those plug ends have little tabs on some of the rheem Ruud units you have to squeeze and then pull or they won't come off if your testing an operating good board you can break it
@integrity5264
@integrity5264 3 жыл бұрын
Thanks Ted, good detail, thanks for taking the time for the video. Your the old Bull teaching the young Bull...stay safe
@garyoconnordbaairrepair7775
@garyoconnordbaairrepair7775 5 жыл бұрын
I generally do not do much business, but I changed out a Control Board on a ICP Package Unit. It had gotten hot and a capacitor split all across itself. One resister burned out and many end connectors on the high side melted. I change those connector ends. The indoor fan motor shorted out and caused all problems.
@Donjuan524
@Donjuan524 5 жыл бұрын
The reason some of the spade connectors were so tight is because on a rheem the Un-insulated ones have a little lock tab that you should depress and they come off easy.
@trevorhvac6799
@trevorhvac6799 5 жыл бұрын
I could be 100 percent wrong but I believe the eac terminal energizes anytime fan is called. I want to say it's on a different relay and want to say I jumped it over to eac before and ran it like that. I just dont remember if it's on the same relay
@skyym3629
@skyym3629 4 жыл бұрын
Take out the ink cartridge one of those cheap ballpoint pens and open up the tip just a little to use for a slide to push over those plastic rivets that hold the pc boards. This has worked well for me.
@kangaroogod
@kangaroogod 5 жыл бұрын
A small piece of 1/4” copper tubing works great to get the plastic push-ins off. Slide it over and pull it out from the back. I always flop the old Board down, mount the new board and then 1 for 1 swap wires
@jburr36
@jburr36 5 жыл бұрын
I had to find the control board for my Lennox package unit on Ebay. 120.00 was the best price I could find for for it
@James_Bowie
@James_Bowie 5 жыл бұрын
At 0:58 I call that a piggyback spade connector. Great short term solution! 👍
@MikeSmith-yy2gq
@MikeSmith-yy2gq 4 жыл бұрын
One honest guy,sure wish he was in my area.He is one Awesome tech.Would hire him in a minute, or partner with him. !
@brianellsworth4767
@brianellsworth4767 5 жыл бұрын
I have replaced some boards and installed many stats. I always wondered if in heat mode when you put the fan on on. Will that override the lower speed for heat. I presumed it would because there is no way for the tstat to communicate that it is in heat mode with only one wire for the blower. It never seemed possible that when you are in heat mode that the board sets a flag for the chip to read either. I just presumed and never checked what happens when a heat call is made.
@captainflappinjacks597
@captainflappinjacks597 Жыл бұрын
Question for you. I just replaced my control board thanks to your video; however, I noticed that a previous tech disconnected the P2 terminal (with the white and black wires) and left it that way. The blower motor was changed last year. The AC has been running with that disconnected for the last year or so, it seems. Should I reconnect that? Not sure what the reasoning could have been for them to leave it off, because I don't know what it does.
@markchambers2812
@markchambers2812 4 жыл бұрын
Excellent content $ informative. You take pride in your work 👍👍
@gregoryfairchild2460
@gregoryfairchild2460 3 жыл бұрын
After tearing apart a lot of relays the contacts get carboned up or blackened until it insulates the contacts and they can't switch on. Some melt the coils but nor many.
@standupforwhatsright4168
@standupforwhatsright4168 2 жыл бұрын
Where does the safety door switch wire go on white rodgers circuit board ?? Unit is York Diamond 80
@nealdownhomeimprovementnea4087
@nealdownhomeimprovementnea4087 2 жыл бұрын
Does a furnace has two sensors?
@Timsautosolutions
@Timsautosolutions Жыл бұрын
Good video
@texasdoug5739
@texasdoug5739 5 жыл бұрын
This video is very helpful...thank you.
@KevinWta
@KevinWta 2 жыл бұрын
How about taking the wire off the old board and immediately putting it on the new board one of the time. That way you won't have to remember anything. But that would only work if the boards were exactly the same.
@petershulick5270
@petershulick5270 3 жыл бұрын
The plastic or nylon standoffs on the control board are the same ones used and computer Technologies and have been the same Wen utilize for the last 38 to 40 years! Soap are needle-nose is more than sufficient to squeeze the little prongs or the thing that locks it into the board and lift the board pass that little plastic locking tab on each four corners of the board
@sknight0391
@sknight0391 5 жыл бұрын
Way to go Rat-Boy #LittleJimmy
@throttlebottle5906
@throttlebottle5906 5 жыл бұрын
lol
@donnierobertson3088
@donnierobertson3088 5 жыл бұрын
Nice job again like always
@terrymckinney1637
@terrymckinney1637 3 жыл бұрын
You should keep a few zip ties in with your meter, always handy that way
@Jonathan05239
@Jonathan05239 2 жыл бұрын
Hello, what can I do when the two green lights remain on and the yellow one does not turn on me. neither does it ignite the fire flame
@Sctronic209
@Sctronic209 5 жыл бұрын
I agree I don’t like to bash other company’s in front of the customer.
@johnmurphyable
@johnmurphyable 4 жыл бұрын
excellent video thank you
@Eddy63
@Eddy63 5 жыл бұрын
Nice vid Ted ...Glad there wasn't any mice involved ... Lol ...
@beautinktong8108
@beautinktong8108 2 жыл бұрын
How do you force second stage heat on to adjust gas pressure?
@papoescapo
@papoescapo Жыл бұрын
I've been looking for a replacement wiring harness or the 4 pin plug upper left of board. 2 of the wires broke off their pins. Anyone know where I can find this harness or plug? I'd like to avoid a service call and or soldering wires directly to the board.
@billreichert6842
@billreichert6842 3 жыл бұрын
Excellent video and explanation. Thanks for sharing.
@erichurst6948
@erichurst6948 5 жыл бұрын
I live in missouri and was thinking about having a dehumidifier added to my HVAC system due to my breathing problems. I was just wondering if you ever install them?
@benjamintimmins1656
@benjamintimmins1656 5 жыл бұрын
Nice video. I like the furnace doors they use too...kinda hard to not put on right
@Farm_fab
@Farm_fab 4 жыл бұрын
Ted, there are companies that specialize in remanufacturing those boards, and it might be a good way to help someone that is struggling financially.
@JAshw84
@JAshw84 5 жыл бұрын
My cooling speed was set to low. The furnace I have is for 2.5-4 ton. I guess low speed is 1000 CFM. The AC is 2.5 ton. I was told by the installer that it’s a factoring setting that needs adjusting based on static pressure. Otherwise the AC won’t be as efficient and most importantly won’t dehumidify properly.
@kowby1417
@kowby1417 2 жыл бұрын
What are the terminals m1 and m2 on the bottom right of he control board my board is wired to m1 where this is landed on m2?
@leonbyrd2621
@leonbyrd2621 5 ай бұрын
How do you troubleshoot this board for failed ignition?
@petershulick5270
@petershulick5270 3 жыл бұрын
The relays don't create enough amperage to burn the boards unless you have some high amperage points on the board itself or transistor or heat sink or something of that sort or a high heat resistor or possibly a capacitor if there's part of a power supply on the board itself Take it from someone who's been professionally replacing or servicing and repair knees boards for almost 40 years
@renj6531
@renj6531 5 жыл бұрын
I take one wire off at a time and transfer it to the new board
@gmctrk63
@gmctrk63 5 жыл бұрын
Good advice at the end for other techs.
@ricardo8salinas
@ricardo8salinas 5 жыл бұрын
Black is high speed, Blue or brown is mid high, Yellow is mid low, and Red is low speed. In most single stage units.
@winkhvac62
@winkhvac62 4 жыл бұрын
Good video man!
@rossr4222
@rossr4222 5 жыл бұрын
Every tech has a phone now. Take a few pics of the board before you replace it is the best thing you can do.
@pravinvarsani4723
@pravinvarsani4723 3 жыл бұрын
Are the relays soldered on to the board or can they be replaced without having to replace the whole board?
@zekenzy6486
@zekenzy6486 5 жыл бұрын
good video. Thanks for shared
@joeydelmarsjr.646
@joeydelmarsjr.646 3 жыл бұрын
i have a 100k 80% 2020 furnace and board looks almost identical
@leonbyrd2621
@leonbyrd2621 5 ай бұрын
I have the same board in mine but mine won't ignite?
@ironmedsvr
@ironmedsvr 4 жыл бұрын
I was told my control board to old and they dont make that version anymore so i need a new ac, this true? We had this ac since we moved in and that was like in 98 when we moved in. Might be orginal ac that was put in when the house was built.
@CHUBBYRAINTHEFIRST
@CHUBBYRAINTHEFIRST 2 жыл бұрын
This was done @12 :30 into video and @12:50 it shows it swapped with the BLUE!
@lee-johnson
@lee-johnson 5 жыл бұрын
Term board $90. Trane equivalent $390. Good work Ted
@MyBallzGotShocked
@MyBallzGotShocked 5 жыл бұрын
Showed the price of the board, you just got a new sub sir.
@markbest5127
@markbest5127 3 жыл бұрын
Is the board dead when it shows no codes?
@watermanone7567
@watermanone7567 5 жыл бұрын
Very nice and neat job. Do the old boards get sent back to be refurbished? or are they junk? Thanks
@Sctronic209
@Sctronic209 5 жыл бұрын
I take and move that control board up and bend the bracket at a angle.
@hrdworkin7633
@hrdworkin7633 5 жыл бұрын
Excellent training video. Thanks
@CHUBBYRAINTHEFIRST
@CHUBBYRAINTHEFIRST 2 жыл бұрын
Did anyone notice for fan speeds he originally installed the RED to HEAT then edit video and I noticed he removed the RED and replaced with the BLUE! Can anyone explain why?
@joeydelmarsjr.646
@joeydelmarsjr.646 3 жыл бұрын
i got the same furnace board and i keep getting a code 22, and i get code 57 and 26 when i first install the furnace door
@publicmail2
@publicmail2 5 жыл бұрын
Probably a $5 relay, why not have socketed relays..Oh yea, they want to sell boards.
@douro20
@douro20 4 жыл бұрын
Somewhat similar relays (with a 12V coil) are in some Kenmore/Electrolux electric stoves where they switch the top and bottom elements. 22V is a very odd voltage, btw.
@rubencastillo2623
@rubencastillo2623 5 жыл бұрын
Just 2 mak sure l always picture wires b4 removig thm
@joeydelmarsjr.646
@joeydelmarsjr.646 3 жыл бұрын
m1 -m2 are mount or park
@beamylist1612
@beamylist1612 3 жыл бұрын
What’s the name of that brass double spade connector he used on board ?
@hvac97849
@hvac97849 4 жыл бұрын
I had an older Rheem Criterian that had the same problem. Must be a Rheem thing.
@scottjones7279
@scottjones7279 5 жыл бұрын
Another thank you
@jermanmarcia2983
@jermanmarcia2983 3 ай бұрын
I def saved myself a 150 bucksssss haha
@jonathanraul4086
@jonathanraul4086 5 жыл бұрын
Ty nice video
@picklerix6162
@picklerix6162 5 жыл бұрын
The control board went bad on my Goodman furnace. Goodman wanted $135 for the board but they wouldn't sell it to me because my license has expired. I managed to find the same board for $69 (free shipping) on Ebay. My neighbor paid an HVAC repair guy $550 to replace the same board. My old, failed board lasted 17 years and the flame detection circuit didn't seem to be working any longer. (The flame sensor was not dirty.) The old flame sensor worked just fine with the new board but I replaced the sensor anyway since the ceramic part of the sensor was cracked.
@tuffram2165
@tuffram2165 5 жыл бұрын
I love watching your videos but whatever camera device or your editing software makes your audio almost impossible to hear. I can't watch you on my phone because it will not go loud enough to hear you. Most editing software will allow you to boost audio. Thanks for all you do Ted.
@97Napkins
@97Napkins 5 жыл бұрын
do real HVAC vid and tell how much you charge for the board? whole youtube community scared to show real life price and profit. Would be only 1
@scottunknown4244
@scottunknown4244 5 жыл бұрын
Patrick S if I had to guess he charged between 4 and 6 hundred for the entire repair which is fair if that’s the case for diagnosis and providing the part at that cost but it all depends on the company and what it takes for him to make a profit on the job everyone has bills to pay so it varies
@ICExMikey
@ICExMikey 4 жыл бұрын
My provider wanted 675 for a new board and ignitor. Didnt mentioned labor. Bought em myself. Waitin on the board now
@dc9039
@dc9039 5 жыл бұрын
Ted, why do you pay tax on parts?
@person12307
@person12307 5 жыл бұрын
Always repair it like its you're equipment
@gordonpotts753
@gordonpotts753 7 ай бұрын
Very nice tutorial
@kennysmith8831
@kennysmith8831 Жыл бұрын
Put a date on board, when replaced
@JAshw84
@JAshw84 5 жыл бұрын
Question - what speed tap would you set the cooling on this furnace for a 2.5 Ton without performing a static pressure test? The model is 801TA075417MSA. I think it’s medium low. Want to make sure. resource.gemaire.com/is/content/Watscocom/Gemaire/rheem_r801ta075417msa_article_1403974088948_en_ss.pdf?fmt=pdf
@MrNebRebew
@MrNebRebew 5 жыл бұрын
You mean half rat man!!! Still trying to unsee that!
@panagwoman7398
@panagwoman7398 4 жыл бұрын
Thanks
@rossr4222
@rossr4222 5 жыл бұрын
Wow easy with the stripper dude. -some bouncer
Furnace/AC How to Troubleshoot The Control Board
9:11
Word of Advice TV
Рет қаралды 859 М.
Little brothers couldn't stay calm when they noticed a bin lorry #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 21 МЛН
managed to catch #tiktok
00:16
Анастасия Тарасова
Рет қаралды 48 МЛН
Секрет фокусника! #shorts
00:15
Роман Magic
Рет қаралды 44 МЛН
The Joker kisses Harley Quinn underwater!#Harley Quinn #joker
00:49
Harley Quinn with the Joker
Рет қаралды 19 МЛН
Rheem Furnace Disassembly - Furnace Repair Help
10:53
RepairClinic.com
Рет қаралды 67 М.
old gas boiler replace Honeywell 24 volt gas valve
26:14
steven lavimoniere
Рет қаралды 17 М.
Replacing Furnace Control Board
11:44
Sam
Рет қаралды 112 М.
How To Replace The Control Board On Your Furnace Or A/C Air Handler
6:32
Bypassing a Furnace Control Board with a 90-340 Relay to get Blower Running
6:10
Apartment Maintenance Pro
Рет қаралды 19 М.
Furnace Troubleshooting Step by Step with Multi Meter.
26:33
Rheem AC clogged dirty coil
4:27
Anti DIY HVAC
Рет қаралды 11 М.
Troubleshooting a  Rheem Gas Furnace
1:32
HVAC Service Technician Talk
Рет қаралды 34 М.
Thermostat Wiring at Control Boards
14:53
Jersey Mike HVAC
Рет қаралды 63 М.
Little brothers couldn't stay calm when they noticed a bin lorry #shorts