thank for the above video. But is it possible to do manually on the PLC.
@aselawickramarathne72533 жыл бұрын
interested....keep it up
@kashifnaveed44943 жыл бұрын
Great sir
@anarghyanagesh895 Жыл бұрын
can we make a similar program for two pumps using counters?
@sennapparajan.p Жыл бұрын
hi .. yes you can use. you have only 2 pumps? for only 2 pumps you can use impulse relay...
@manilakshmi6118 Жыл бұрын
Good, but I have one doubt ji, if any one motor trip how the sequence running. My project 4 no's motor running sequence 1234then again 1234 if any one motor trip or off that motor only skip in program. Other will continue running sequencely pls give Idea
@sennapparajan.p Жыл бұрын
if all the motor is running then there is no sequence .
@manilakshmi6118 Жыл бұрын
@@sennapparajan.p ji, float switch on, No1 motor on), 2nd time float switch on No2 motor on, motor1off. Same pattern next output. then the sequence go throw until No 4,after again come to No1motor . In between any one motor trip automatically sequence go throw next motor. How will do?
@sennapparajan.p Жыл бұрын
@@manilakshmi6118 WILL DO A VIDEO...
@manilakshmi6118 Жыл бұрын
@@sennapparajan.p when you upload video about my logic
@manilakshmi6118 Жыл бұрын
Ji any one motor trip in the your sequence. how will it run?add to do Trip logic circuit in the program and upload onemore video pls......
@jaypatelsteam2 жыл бұрын
Thanks for explanation
@sennapparajan.p2 жыл бұрын
you are welcome... kindly subscribe...
@Rushymuh2 жыл бұрын
Thank you for the explanation. But I found an issue in the program: When 7th time pressing the PB (pressure input) 1st & 2nd pumps should work but still holds pump 3rd & 1st. Please clarify
@sennapparajan.p2 жыл бұрын
issue with your program or program in my video??
@Rushymuh2 жыл бұрын
@@sennapparajan.p I tried similar program, but I found the 6th & 7th presses are activated same pumps 1 & 2 twice.
@sennapparajan.p2 жыл бұрын
@@Rushymuh please try once again following the video...if cycle restarts in 4th push then it will continue.... no change of error in 6th or 7th push....
@Rushymuh2 жыл бұрын
@@sennapparajan.p Similar program checked and still I have the problem after 6 & 7th outputs are the same. REASON: After 4th PB pressing C1, C2 & C3 count 1, C4 resetting In 5th - C1 reset, C2 & C3 count 2, C4 count 1 In 6th - C1 count 1, C2 reset, C3 count 3, C4 count 2 In **7th - C1 reset, C2 count 1 & C3 count rest, C4 count 3 **At this 7th PB press C4 not resetting itself. So, output holds as in 6th.
@sennapparajan.p2 жыл бұрын
@@Rushymuh send your program will check sales.hmbllc@gmail.com
@kashifnaveed44943 жыл бұрын
Make a video on chilled water pump with differential pressure transducer with siemens logo.
@sennapparajan.p3 жыл бұрын
please mention working logic...
@MrDhainesh2 жыл бұрын
Hiii bro, i have some queries on this. Possible to clarify?
@sennapparajan.p2 жыл бұрын
Sure… yes…?
@MrDhainesh2 жыл бұрын
@@sennapparajan.p thanks for your response. Can show me roughly how to do program for 3 pumps control by 2 pressure switch. Its a cyclic operation. When ever duty pressure switch activate 1 pump should run and next cycle other pump should run. If 2 pressure switch activates means 2 pumps should cut in. Much appreciate if u give some idea on it.
@sennapparajan.p2 жыл бұрын
@@MrDhainesh SURE WILL SHARE THE VID...
@sennapparajan.p2 жыл бұрын
@@MrDhainesh kzbin.info/www/bejne/gaPLaX-saa6fjq8
@MarkStaMaria-xu4tq9 ай бұрын
Something is wrong. after 2 alternating cyclic, sequence is 1, 2, 3, 3 / 1, 2, 3, 3
@sennapparajan.p9 ай бұрын
send your program. will check senindra123@gmail.com