Man, thank you. Just took the first of three bids for an EBB retrofit and the guy included an optional line item for retrofitting the posts. Thanks for the explanation.
@ericsb75 жыл бұрын
Hi. Very clear video. I was hoping at the end that you would show what type of connection or bracing is necessary for an older foundation where the piers are merely siting on top of a concrete block and not currently connected at either the top or bottom. Thanks.
@bayarearetrofit58145 жыл бұрын
Can you send me a photo of what you are talking about? The code says only one nail is required at the bottom. Type in "Post to Beam" in the search bar and you will see the code citation on the webpage. I thought this was included in the video.
@86boanerges4 жыл бұрын
@@bayarearetrofit5814 Great video and I also hoped that you'd provide an image of the right nail connection that you are referring to.
@bayarearetrofit58144 жыл бұрын
Toe Nails
@86boanerges4 жыл бұрын
@@bayarearetrofit5814 Thanks
@bayarearetrofit58144 жыл бұрын
Happy to help. If you could subscribe I would appreciate it.
@chrisc74655 жыл бұрын
Thanks for this video. I only have 8 post and beam connections in my crawl space but this saves me ~$200 that I can use for retrofit material that I actually need!
@ahurtarte112 жыл бұрын
I was qouted $7500 for post connections in 2022! Thanks again for the wealth of knowledge, Howard.
@bayarearetrofit58142 жыл бұрын
Happy to help. Please promote the website by subscribing.
@bayarearetrofit5814 Жыл бұрын
What are steel plate shims?
@sethmeistergee2 жыл бұрын
When looking in my crawl space I noticed that several posts have almost completely slid off their pier blocks. Is THAT something you'd recommend fixing? If not, I'd worry that my floor would start sagging from the lack of support...
@bayarearetrofit58142 жыл бұрын
I would say it does not matter in terms of resisting lateral earthquake forces but does matter as far as gravity goes.
@bayarearetrofit5814 Жыл бұрын
The code says put a nail at the bottom of the post. Read the article. It also says the purpose of a connection here is simply to keep the post in place in the event someone kicks it by mistake. Everyone puts nails at the top and bottom of the post but you don't really need to per code.
@Max-jn5sp4 жыл бұрын
thank you for the heads up, your videos saved me from making a stupid purchase
@bayarearetrofit58144 жыл бұрын
Glad I could help. Please be sure and subscribe.
@seanz1232010 Жыл бұрын
Do you have any videos pertaining to a stone foundations from southern california...I have a 100 year old house and the original foundation is still mostly there but slowly crumbling outward in areas? I would think retrofiting it would be an option?
@bayarearetrofit5814 Жыл бұрын
On the homepage there is a video on old foundations. Your house has the equivalent of a crappy brick foundation.
@jjf6093 ай бұрын
1) What is your opinion on shear transfer ties bring added to the joist near edges? Do you recommend them? HUS26 Double Shear Joist Hanger 2) Do you think the 4 corners foor joists shouod be reinforced? Thank you for your expert advice
@bayarearetrofit58143 ай бұрын
I am sorry, I do not have time to help design people's retrofits. All the info you need is on the website.
@drowe28 ай бұрын
This is awesome but what should you do to maximize safety from earthquakes? I live right near one! I was going to put on those Simpson ties so I won’t waste my money on these. I have beams supporting a 1-1/4” plywood floor so now floor joists. What should I do?
@howardcook358 ай бұрын
You should have 4 x 6 beams on the entire perimeter. Connect those to the sill with Simpson L90s, add URFP, make sure and engineer it with the info on the website, and call it a day. If you could post a YELP review that says some good things about the website and your experience with me it would be appreciated
@drowe28 ай бұрын
@@howardcook35 many thanks Howard! I will do!
@bph52 жыл бұрын
Extremely helpful. We are in north Oakland and assessing the viability (cost) of doing an extension and/or garage conversion ADU and this has really helped to educate me.
@howardcook18772 жыл бұрын
Thanks for letting me know. Helping people like you is the reason I put the website together
@centexan Жыл бұрын
Working under an older house to level it was not a favorite thing that I have done. You start jacking up the house and it starts creaking and cracking. Very nerve-wracking. Get the steel plate shims in and get out.
@shanecurran2877 Жыл бұрын
great video, what about old underfloor that have 3',4' posts supporting etc ..bracing does help
@jimf24822 жыл бұрын
So what exactly SHOULD you do for a seismic retrofit?
@tyrice24earl2 жыл бұрын
I was confused also because he gave all the examples about how not to do it and waste money, but he never stated the correct way to do it and engineers just don’t design to design. Please advise.
@seesaw7289 Жыл бұрын
I agree! I have a 16' beam through the center of the house sitting on two posts, each post made of 3 - 2x6"s nailed together. I'm worried that lateral movement and shaking could knock the beam off the posts and was hoping to see if there was a way to shore the posts up to the floor joists. If the beam falls off the posts in a quake, the house and roof will cave in.
@timreyes217926 күн бұрын
Sounds like the main retro fit would be to attach the exterior walls to the foundation with substantial hardware. That will keep the house from moving laterally off of the foundation. Plywood instead of shiplap or skip sheathing on walls would probably also help even if your building has let in bracing cut into the studs
@CiscoMagic-m1l24 күн бұрын
Watched your video to answer the questions you answered. I have post and pier and the pier are toe nailed into the concrete pier. Seems this is sufficient? I’m in Santa Cruz county.
@bayarearetrofit581424 күн бұрын
No, it sounds you need a foundation. You must be in one of those old cabins in the hills around Santa Cruz. If you need foundation work there is a guideline that was written for houses like yours.
@CiscoMagic-m1l24 күн бұрын
@ it’s in Aptos.
@CiscoMagic-m1l24 күн бұрын
@ not sure how to send a photo here.
@CiscoMagic-m1l24 күн бұрын
The house was built in 1950 on s brick foundation but the breaks are longer than regular bricks. It’s in great shape. The mission is unbolted and sits on top. I’ll follow your diagram putting bolts every 12” using the hilti 270 epoxy, then strap and shear. Should shear cover the pony wall completely? On the post and piers I see no evidence of movement. You said bracketing is useless. Could do the T straps like your video shows and a Simpson thing from post to base. But again you say no. Like mentioned and you pointed out it’s toe nailed from post into pier. Wish I could show you.
@CiscoMagic-m1l24 күн бұрын
Post and pier look exactly like your video above
@wsiddiqi4 жыл бұрын
Thanks - very useful into. Going thru EBB process right now for my house and this was an option that my contractor proposed. I rejected it since it wasn't required and also thought its something I could easily do myself. However watching this video, it basically means I don't need to do it and its not needed.
@bayarearetrofit58144 жыл бұрын
That is right, if I had a quarter for every unnecessary piece of hardware I have seen under houses I could spend all day making videos. Please do me a favor and subscribe.
@donaldhendrickson68035 ай бұрын
I got EBB approved recently. I was only going to install the universal retrofit foundation plates per code and thought that would be sufficient. However, watching several KZbin videos it looks like code also requires upgrading mud sill bolts on older homes (mine was built in 1965) and drilling vent holes in cripple wall plywood and would like to know if that’s accurate. Thank Donald
@bayarearetrofit58145 ай бұрын
The EBB requires that you use either FEMA P-1100 or Standard Plan A to qualify for the grant. You can find a comparison between the two systems on this webpage. bayarearetrofit.com/fema-p-1100-icc-1300-and-standard-plan-a/ Please study this webpage so that you know which system you want to use. This is an important decision and will make a big difference in terms of cost.
@jimmiedow4 жыл бұрын
I have brick walls on top of a brick foundation and the floor is held up by posts like this. I am lifting/leveling the floor joists and was going to replace the floor beams and posts and add metal hardware like in this video. I see what you mean about that hardware being worthless, but in my case I don't know how to securely attach the house to the brick foundation since brick seems fragile. Instead of posts holding up the floor should I put shear walls under the floor and hope that also adds stability to the brick structure?
@bayarearetrofit58143 жыл бұрын
Sorry I am so late in my reply. I do not know KZbin did not notify me about your comment. Look at my webpage on brick foundations.
@thomasb.182510 ай бұрын
Is fixing the sinking perimeter walls enough or shall we combine attention on both …. I have the case in my crawlspace , the middle piers are kinda sinking not because the soil is softer there but precisely at the bottom of the perimeter foundation walls sinking or tilting cause of water badly diverted around the house foundation walls on which each end of the main girder is sitting. So the support sinking the girder is kind of sliding out of its place n push down on the piers supporting it in the middle .. question is how do you get the perimeter walls issue fixed … I mean once the job of getting the rain water away from the house ? Please give us some guidance there your video threw all my courage down into the deepest spot of the crawl space
@bayarearetrofit581410 ай бұрын
The only thing I know is to level the floor. To do it right you need to use a laser. Maybe there is something on KZbin. I have never done it myself. If you discover anything let me know.
@life_of_riley888 ай бұрын
You can use a water level to level the floor. Get 100' of 3/8" or 1/2" vinyl tube and fill it with water. Attach it to two sticks, stakes, or rods. Place one of these against a door frame solidly with the bottom resting on the floor. Do not let it move. Then go around the house and measure the level of water from the floor to the level point. You can then build a map of where your floor is out of level. I will be doing this in my south bay area home built on expansive clay soil in the coming year.
@timlane95114 жыл бұрын
What is done with older homes that are all post and beam? Is the house jacked up and a perimeter foundation added?
@bayarearetrofit58144 жыл бұрын
Yes
@paulcoffman98413 жыл бұрын
Nice video. I just put upside down triangle plywood over side of beam and post. Not sure what happens when the big one comes and ground give way.
@ZorroInvest4 жыл бұрын
Is the leaning post something worry about?
@BayAreaRetrofitTV4 жыл бұрын
No, not at all. Sometimes contractors put the concrete pier block in the wrong place such that it is not directly under the beam. When this happens they need to put the post in at an angle so that the beam is supported. I used to do a lot of structural work not related to retrofitting and know from experience that if you remove a few posts you won't even notice it except the floor might have a little more bounce in that area.
@glaoak17872 жыл бұрын
It would be helpful to have a link to the proper way to do so.
@bayarearetrofit58142 жыл бұрын
There is no reason to learn how to properly do something that does not need to be done. Watch the video and read the code citation one more time.
@RolandZapata-t9o10 ай бұрын
Just curious what city building code this is?
@bayarearetrofit581410 ай бұрын
International Residential Code
@Patriots20044 жыл бұрын
Thank you for a clear and informative video on this. Would be interested in seeing a video on bolting down a house after lifting it and then putting it back down on a new foundation.
@bayarearetrofit58144 жыл бұрын
I am going to need to leave that video to you. Good idea!
@react12004 жыл бұрын
If everything strapped up to the floor joists, wouldn’t it provide some resist from the home flying off the permitter?
@react12004 жыл бұрын
Also, if strapped wouldn’t it add support against cripple wall failure? Not trying to be a contrarian, genuinely trying to understand. I’m a DIY’er with an old home.
@bayarearetrofit58144 жыл бұрын
There are two types of earthquake faults, thrust faults and lateral-slip faults. The Hayward Fault is a thrust fault. Thrust faults have a vertical component. The building code does not recognize this force as being something you need to resist, though Simpson StrongTie likes for people to believe otherwise so they can sell more hardware. Houses move up with the ground and down with the ground. They do do not become separated because of upward acceleration. That is why building codes do not address vertical acceleration. Hope that helped. If you haven't done so, please subscribe.
@williamchenoweth32264 жыл бұрын
Bay Area Seismic Retrofit So you are saying that houses do not bounce and there is no need to add vertical connection from the beams to the post to the pier? A single nail from 100 years ago placed at the bottom is adequate? Genuine question, I wasn’t aware vertical acceleration is not of concern.
@bayarearetrofit58144 жыл бұрын
Many faults, such as the Hayward Fault, are thrust faults which means there is a vertical component. However, the building code a observed evidence do not see this as a source of damage. The building code only requires exactly what you describe. I personally would add a few nails to the top and the bottom "well, .....just because" as the structural engineer who helped me put that video together expressed it.
@andresjimenez38113 жыл бұрын
I been upgrading my house and been using this metal plates anywhere I can. Probably keep doing it.
@whoarru3601 Жыл бұрын
Wow, thank you! I was thinking of spending a bunch of money to put a third beam under my house....no more!
@dylansoto75262 жыл бұрын
Foundation Retro fit is recommended in California especially if your home was built before 1930-1940.
@tyrice24earl2 жыл бұрын
I am confused????! You gave all the examples about how not to do it and waste money, but he never stated the correct way to do it, and engineers just don’t design to design. Please advise.
@bayarearetrofit58142 жыл бұрын
Why show a correct way to do it when there is no reason to do it. It is hard to imagine a correct way to do something that does not need to be done.
@JO-cj2dv Жыл бұрын
Plenty of engineers design things just to design. If not, half of them would be out of work…
@ej59363 жыл бұрын
Thank you for sharing, the question I have one can spend between 15K to 25K on building a deck but avoid securing it because gravity will play a big role so we can save between $500 to $2000 is it technically fair to say that you need x amount of material based on the size, height, and location (hot, cold weather)
@howardcook18772 жыл бұрын
There are too many unknown factors to give you an answer.
@hbaizer3 жыл бұрын
Interesting video. I have a question though. When you say "one nail", where would that nail go? Probably a dumb question, but I can't picture the answer.
@howardcook18772 жыл бұрын
It says at the bottom of the post. Read it again.
@robfred27137 ай бұрын
I had the same question. A nail into the bottom of a wood post into what, the cement pier? Those L shape straps seem simple enough, my posts are half hanging off the piers.
@roodypazoo52163 жыл бұрын
Your video made me feel better about my post to beam connections on my deck . 2 levels , 38 years old , southern cal , all Doug Fir . Rim beams are 4X 10 X 16’ connected to 8X8 20’ post with 1” through bolts and or lags. There are a lot of videos talking about that connection should never rely on shear strength of 2 bolts. I’m assuming when it was built it was code. It may still be ? Thanks for the video .
@Defnotdoge7 ай бұрын
I have the same type of deck but less lumber. 6x6 with one 2x10 rim. I think if you add a Deck Joist Tie you'll sleep better at night. That basically will make your connection the same as beam on post
@bayarearetrofit58144 жыл бұрын
Yes, and do a search on brick foundations. It contains an article I wrote that will help you.
@jimmiedow4 жыл бұрын
Thank you, I will look at that.
@chrissilkwood54393 жыл бұрын
well, here's the rub... in remodeling a bathroom, an engineer is sometimes required by the city in order to sign off on the permit. The engineer makes calculations and requires / specifies Simpson-Tie post connectors (the AC4) like the ones shown here which you consider unnecessary. As a homeowner without an engineering degree, how does one combat the engineer's recommendation in order for the city to sign off on the permit? I am of the mind to just lock everything in under the house since no one knows the direction and type of earthquake that's coming. The AC4 and hurricane connectors are relatively cheap and require a little elbow grease under the house.
@bayarearetrofit58143 жыл бұрын
Fighting with an engineer is a waste of breath. You can cite the code which you find on the webpage but they won't listen. Your idea is a good one.
@alkira9894 жыл бұрын
You mention that post and beam connections are not a proven retrofit technique - this uses a crawl space as an example. Does also apply to soft-story conditions where there are fewer total posts? (first story garage with crawl space > 7 feet).
@bayarearetrofit58144 жыл бұрын
The same principles apply, though in my opinion the posts could be dislodged from the shaking itself regardless of whether or not the floor moved. It is so cheap to strengthen this connection, even a few nails ought to do it, why take the chance? Especially when you have a limited number of posts.
@alkira9894 жыл бұрын
@@bayarearetrofit5814 Sure makes sense regarding nails, why not? How about other recommendations such as far as adding hardware connectors / improving concrete footing?
@bayarearetrofit58144 жыл бұрын
Leave the concrete alone. Search for SEAOSC and as far as the rest of it, it is all important.
@bayarearetrofit58144 жыл бұрын
Look at my video on Standard Plan A, which is what you will need to use. Once you see it you will probably decide to do something else.
@bayarearetrofit5814 Жыл бұрын
The building code is the building code so I dunno!
@GregoryDibb4 жыл бұрын
I don't understand why this is a complete waste. Your other videos show the importance of preventing shear, uplift, etc by building shear walls. Are you saying shear walls are all that's important, that they will take the force instead of these posts and beams? It seems like the hardware you are saying is a waste would help prevent some shear force? thanks. Great videos.
@bayarearetrofit58144 жыл бұрын
A post provides zero lateral resistance. Imagine the floor sitting on top of the post and the floor happens to move a foot, the post will tip over. If the house remains secured to the foundation the floor will not move on top of the posts at all and the posts will not tip over. In other words, if you secure the house to the foundation on the perimeter the floor will not move on top of the the posts don't need to resist anything. The metal post connectors you are referring to have ZERO lateral resistance according to the manufacturer. Why put in hardware that is labor intensive, is not required by the code, and offers zero lateral resistance? If the post is required to resist lateral force because the house has become disconnected from the foundation you are screwed anyway. Best to spend your money where it counts.
@GregoryDibb4 жыл бұрын
@@bayarearetrofit5814 got it. Okay that helps-visualizing that everything will move together as long as the walls in the foundation are strong and properly done. Thanks, great videos.
@bayarearetrofit58144 жыл бұрын
Ask anything, anytime.
@tyrice24earl2 жыл бұрын
I was confused also because he gave all the examples about how not to do it and waste money, but he never stated the correct way to do it and engineers just don’t design to design. Please advise.
@davidrutan Жыл бұрын
@@tyrice24earl check out his many other vids. He covers the important stuff about proper installations and recommendations there.
@scotthester-g9m10 ай бұрын
Maybe the supports were installed for support purposes only and not for seismic retrofitting. A lot of houses that were built a long time ago may require additional support over time. Personally I feel the photos were used out of context to make the video, since the drawings or plans do not mention for seismic activity but they also do not mention for structural support. I would think you need some type of shock absorbers or the house to be on rollers to handle serious seismic activity. Posts or no post are not going to save the house from an earthquake. The perimeter of the house would be more important than the middle when it comes to seismic activity.
@bayarearetrofit581410 ай бұрын
Please go to bayarearetrofit.com and search for "post to beam" and read the code requirement.
@bayarearetrofit5814 Жыл бұрын
There is an answer. It is not worth bothering with. Why fix it if it ain't broke? Why address a problem that is not a problem? Why do you think this connection is a failure point?
@tmaila7 ай бұрын
What is the failure point and how to properly address the failure point?
@Howard-hl4cp7 ай бұрын
@@tmaila there isn't a failure point
@JustMe-jc2ft3 ай бұрын
In deep frustration i saybto you, This video gets zero out of 10 stars. I don't need to know what doesn't need done. I need information on the affirmative steps I need to take to have a standing house at the end of various kinds of earthquakes: Bouncers, side shakers and rollers. I have a late 1800s, 2 story pioneer on pier and post. Yes having a perimeter foundation will be best, but I haven't the money yet. What should we do meanwhile?
@bayarearetrofit58143 ай бұрын
Look in the pdf library. There is a guideline on how to address pier and post foundations.
@JustMe-jc2ft3 ай бұрын
@bayarearetrofit5814 thanks for your response. When you get to it, can you make an affirmative how to video showing what needs done. I don't read "engineering," but I learn quickly if you show me while explaining what's working
@bayarearetrofit58143 ай бұрын
It is not at all clear to me you want that I have not already provided.
@JustMe-jc2ft3 ай бұрын
@bayarearetrofit5814 you referred me to a pdf. Those are hard to deal with. I was asking for a video for the visual aids. I searched your site and found this video but it isn't an affirmative action video. It's a "don't do this" video. Ok I won't do this, but what shall I do? If you have that, just let me know what it's called and I'll go look for it.
@bayarearetrofit58143 ай бұрын
I think I know what you are looking for. Videos take a tremendous amount of work and I just don't have time.
@stevecarlisle3323 Жыл бұрын
I watched the video from beginning to end, and What I took away from that was his recommendation to use nothing to attach the post to concrete, and post to beam. I do not think you would ever get a occupation permit following his logic, right or wrong. 🤔
@bayarearetrofit58149 ай бұрын
Yes you would. You are following the code.
@TJtheDJonWMCN11 ай бұрын
I hear you state your conclusion that the examples you show are "useless" and a "complete waste of money", but can you include a link or provide the evidence for what you believe is useful?
@bayarearetrofit581411 ай бұрын
Anything that will keep the post up when you kick it, which is just about anything. Please read the information on the webpage at bayarearetrofit.com/post-beam-connection/
@TJtheDJonWMCN11 ай бұрын
Thanks! @@bayarearetrofit5814
@bayarearetrofit5814 Жыл бұрын
I am happy to hear it helped you. Because they see some stupid engineer recommend them.
@dfrusdn3 жыл бұрын
Even though this is not required by IEBC it is recommended by Simpson Strong in their 2019 Seismic Retrofit guide for raised foundations under section AC Post Caps and loads are actually available on the specs sheet. So it is NOT a waste of money
@bayarearetrofit58143 жыл бұрын
It is important to remember that Simpson is in the business of selling hardware, not public safety or spending people's money wisely. Their plan set and guide has other recommendations that are not logical, but they do increase hardware consumption. Impartial agencies such as the ICC are not trying to sell anything. In the end one must listen to both sides, see which is the most logical, and act from there.
@glaoak17872 жыл бұрын
This is like the oil companies saying that you need to replace the oil every 5k. Or the umbrella company saying to replace your umbrella every 5 raining seasons.
@JO-cj2dv Жыл бұрын
You’re joking. Right?
@makingitmatters9587 Жыл бұрын
so good!
@bayarearetrofit5814 Жыл бұрын
Yes, this video has saved a lot of people a lot of money.
@blakeessex6092 жыл бұрын
I see your point as it is related directly to seismic or 'lateral' loading incidents. However, you are leaving out two additional VERY important types of loading conditions...The first is due to soil movement (shrink/swell) and the second is wind uplift anchorage. These connections are instrumental in aiding in structural stability of the home during those two types of loading conditions. To tell people that the engineers are simply "not educated" enough and just spec these connections because they are uninformed is a bit dangerous on your part. Especially given the fact that you didn't even mention these additional loading conditions...It is the engineer's job to think through and design for ALL possible future loading conditions. IF you are going to make a video spreading misinformation, maybe you should be able to disprove the need for those connections ( after applying all loading conditions) mathematically. IF you cannot, you are not qualified and you should simply not speak on these matters. Also, I will remind you that the IRC code is the MINIMUM spec allowable. It should not be looked at as the end all/be all for construction. It was created to give the contractor and homeowner information on the absolute MINIMUM safe design conditions.
@bayarearetrofit58142 жыл бұрын
I see your point as it is related directly to seismic or 'lateral' loading incidents. However, you are leaving out two additional VERY important types of loading conditions...The first is due to soil movement (shrink/swell) and the second is wind uplift anchorage. These connections are instrumental in aiding in structural stability of the home during those two types of loading conditions. I live in an area that is almost entirely unconsolidated soil that shrinks and swells as you describe and have never seen a post connection come apart even the least bit. To tell people that the engineers are simply "not educated" enough and just spec these connections because they are uninformed is a bit dangerous on your part. Especially given the fact that you didn't even mention these additional loading conditions. How are a few nails or even steel straps going to prevent a house from lifting up off its foundation? We do not see this kind of damage in earthquake county, at least I am not aware of any. From my point of view building codes inform engineers and contractors which connections are important, and this isn't one. ..It is the engineer's job to think through and design for ALL possible future loading conditions. IF you are going to make a video spreading misinformation, maybe you should be able to disprove the need for those connections ( after applying all loading conditions) mathematically. I do not look at theoretical/mathematical conjecture. I look at empirical evidence and also hope that the authors of the building code did the same. If you can find ONE photo of failure to a post beam connection due to soil displacement I will point that out because I have some empirical evidence to back it up. If you can find another photo with wind damage that would also be helpful. IF you cannot, you are not qualified and you should simply not speak on these matters. Also, I will remind you that the IRC code is the MINIMUM spec allowable. It should not be looked at as the end all/be all for construction. It was created to give the contractor and homeowner information on the absolute MINIMUM safe design conditions. And it should be based on a MINIMUM amount of empirical evidence and I don't see any. Also, in seismic retrofits one must also look at the math in terms of spending their money wisely and cost-effectively. Really, please send me photos, not math formulas, of the two types of failure modes you mentioned, that occurred in earthquake country. I am always eager to update my site and provide accurate, evidence based, information.
@moon3173 Жыл бұрын
all the criticism yet no answer provided.
@bayarearetrofit58149 ай бұрын
This subject is very technical for most people and speaking slowly is helpful.
@sandeephansdak3143 жыл бұрын
...and!...."resist-ant-to-Earth-quake?!... "...Hmm?!... So, why not then think about de-signing "Rocking"..., "Jumping"...and "Swinging" "Building-Design-Structures"!?.....Nyet.. ?!...I, I don't know!....Im-possible?!.....😃
@infocook48543 жыл бұрын
Sounds like it will work to me
@1960jogo3 жыл бұрын
Is just a waste money
@sandeephansdak3143 жыл бұрын
...and!...."Shock-Absorbers" can help?!....😃
@befdreams8 ай бұрын
All this talks about is what NOT TO DO, how about WHAT TO DO ???
@howardcook358 ай бұрын
You missed the point. THERE IS NOTHING TO DO.
@tombryan1 Жыл бұрын
I disagree with you on many of your observations
@bayarearetrofit5814 Жыл бұрын
Great! Let me know what you disagree with on each video you disagree with and we can have a conversation.
@thomasb.182510 ай бұрын
Not helpful at all cause you’re developing above n beyond the wrong done communally done by lots of contractors under guidance of structural engineers but you’re not giving us a clue of how to address failing piers on old houses if not this way … at least if you have it give us an alternative so that we can learn how to address this issue better… thank you
@bayarearetrofit581410 ай бұрын
What do you mean by failing?
@okanx4737 Жыл бұрын
Theese enginners loves money
@bayarearetrofit5814 Жыл бұрын
Contractors too!
@truthseekerKJV Жыл бұрын
The video spends most of it's time showing what is a waste of money while failing to show the right way to do it.
@bayarearetrofit5814 Жыл бұрын
The right way is to follow the code which is illustrated in the video. Watch it again.
@supernova89623 жыл бұрын
I would not use you. You do too many cut backs. You remind me of Surfside.
@xaddict44208 ай бұрын
would have helped more if you showed the CORRECT way to do it and not shighting on others work
@bayarearetrofit58146 ай бұрын
I quoted the code. It is up to the reader to decide if I am shitting on other people's work.