Hey señor Solar, loopt ik toch zo tegen jouw video aan tijdens mijn zoektocht naar kennis. Mooi man. -Keniaanse Johan-
@SolarSolution Жыл бұрын
Haha hey kerel! Wat leuk om van je te horen!
@alexvassilev95862 жыл бұрын
Great job, mate. Love your videos. Keep on the good work! 🍺🍺🍺
@SolarSolution2 жыл бұрын
Thanks Alex 👍
@TFitz10 ай бұрын
Voltage x Current = Power
@SolarSolution6 ай бұрын
Haha that is correct, thanks!
@irrigacka Жыл бұрын
Great work, well explained!!
@SolarSolution Жыл бұрын
Glad you liked it Caxito!
@stecybanda70984 ай бұрын
Watching from Zambia
@SolarSolution4 ай бұрын
Good to hear from you Stecy!
@Bio-chemest11 ай бұрын
I want to know whether that 216 can be connect to hybrid inviter at ac input
@ScientistPrepper2 жыл бұрын
Good video. Thank you for making it.
@SolarSolution2 жыл бұрын
Glad you liked it Dino!
@SolarSolution2 жыл бұрын
Course trailer and Coupon Code: kzbin.info/www/bejne/jHzEkKx4ntpqaJo
@RichardAmevorshie2 ай бұрын
Where can I get the full course to buy?
@SolarSolution2 ай бұрын
Hi Richard, here is the link to the full course: www.udemy.com/user/jesse-gorter-3/?srsltid=AfmBOooWo4_tn8MWrEnko8wb77idwl9Cnvts7BxeoxvAYepffmNdBFg_
@TendayisydneyNyaruviro7 ай бұрын
Well explained that you
@SolarSolution6 ай бұрын
You're welcome!
@suleimanmuhammedhady11982 жыл бұрын
I want to know series and parallel connection which is better for a hybrid inverter
@ardehshir4590 Жыл бұрын
hi there, I have bought 4 solar panels 340w ,Max Current (Imp) 9.82A Max Voltage (Vmp) 34.6V Short Circuit Current (Isc) 10.51A Open Circuit Voltage (Voc) 42.5V Weight 18.7KG Dimension 1664x992x35mm Cell Technology Monocrystalline but I didn't parallel yet I need help before somethings goes wrong LOL, my system run by 48v do I need to do parallel them?
@dwightdeubner982511 ай бұрын
Would it still work to have 6 modules in parallel an the tie the two in series
@wild_monte Жыл бұрын
Really like the video and your explanation. Just have one question, shouldn't the system current be 13,889 since there's also a parallel connection (2x6,944)?
@JaakJacobus Жыл бұрын
The calculator can't process that information. It can only do parallel OR series. And yes, you have double both the total Amp. and Watt after calculating one of the series.
@ShowemRight Жыл бұрын
Should I be ok with 1 Poly Renegy 100 watt panel with 2 mono Renegy 100 w solar panel? I bought the Poly about 7 years ago, and the 2 mono panels 1 month ago, and we have 2 JJN 100 w mono panels arriving soon .
@davidkanm6072 Жыл бұрын
Good👍
@SolarSolution Жыл бұрын
Thanks David
@ochitijohn7907 Жыл бұрын
Perfectly does it mean series or parallel meaning 24volt system
@joehebbo70472 жыл бұрын
If my inverter is 8kw voc 370 (125~500) which one is right 370 or 500 the max voltage?
@awa28279 ай бұрын
@awa2827 19 hours ago Hi thank you for your helpful videos. I have a question about my solar system. I had 12v solar system with 10-180 watts panels and 2 lead acid batteries 12v/200amp connected parallel. I have them about 5 years and last month I bought 2 lithium batteries 230 amp each. When I connected new batteries, my inverter would turn on and off automatically every few minutes when there is less or no load connected to the system. I have 5000 watts Giandel inverter. I thought my inverter had a problem so I bought another inverter. This time I bought a 24v 5000 watt inverter and switched my solar panels to series. And I still have the same problem. I searched online but could not find any helpful information. Will you please help me out with this issue? Thank you so much.
@dieseldawg7132 Жыл бұрын
Quick question let’s say you had 9 panels but have to do 5 in series and then the 4 in serious and the tie them In parallel will that work out or do you have to have an even amount of panels?
@JaakJacobus Жыл бұрын
Even or odd numbers but always the same amount in both series. In your example the set of 5 would pump its energy into the set of 4. I guess you run the risk of being in the market for a new set of panels after frying the old ones.
@dieseldawg7132 Жыл бұрын
@@JaakJacobus thank you that makes alot of sense !
@yusifsuleiman5502 Жыл бұрын
What happens if I connect 120v dc with 80v dc in parallel from solar panels
@dieseldawg7132 Жыл бұрын
It won’t work right I already ask this question as well As you can damage your panels you need to have an equal amount of panels with equal specs
@danielteyehuago163311 ай бұрын
I'm here again
@SolarSolution11 ай бұрын
Hey Daniel!
@igorkvachun35722 жыл бұрын
Yes 👍 ☀️⚡🔌💡
@RemjiusMiyaiodongo Жыл бұрын
In terms of length of time .Which one lasts longer? Parallel or series ?Somebody answer please
@hariprasath85045 ай бұрын
It's depend on design sir,maximum pannel we connect series type of connection.
@brentfrank701210 ай бұрын
I’m shocked you didn’t discuss amps
@SolarSolution10 ай бұрын
P = V x I
@niharranjandas6569 Жыл бұрын
দারুন
@SolarSolution Жыл бұрын
ধন্যবাদ নিহার। আমি খুশি আপনি ভিডিও উপভোগ করেছেন.
@mrDADtheSecond11 ай бұрын
Each panel is almost 7 amps
@gor49882 жыл бұрын
What am I missing here ? In your series example of 6 panels, your multiplying both voltage and current to reach 216 volts at 1,500 watts Then adding an exact 6 series panels, in a parallel string adds only current not voltage, 216 volts but now at 3,000 watts output If both parallel strings gained v+a Couldn't you have 6x36=216 volts , 6x250=1,500watts Added to another string of 6 panels And then get 12x36=432 volts , 12x250=3,000 watts More power = 😁
@ralphghawi56562 жыл бұрын
I thought no one is gonna mention that :D
@gor49882 жыл бұрын
@@ralphghawi5656 Its been 2 months and your the first 🥉
@fullelectricro2 жыл бұрын
Current is not measured in wats. The current is the same in one string. He doesn’t show the current. So 6x36=216 volts at 6.19 amps. Another string of six added in series will be 433 volts at the same 6.19 amps.
@chriskennedy7534 Жыл бұрын
@Full Electric Your right, my misunderstanding
@Chuppe_g4 ай бұрын
So pararrel connection is the best
@jounikyy7715Ай бұрын
nuclear better for most and living near nuclear plant even cheaper