thanks for explaining the motor blocked fault with great clarity
@jasonwattsae Жыл бұрын
You're welcome! It has definitely caused a lot of downtime. I will probably bring it up again in one of my livestreams in the future. Thank you for supporting the channel!
@bhushandandge42729 ай бұрын
Hello Jason thanks for such a nice video and making so much of our doubts clear. Can you also explain what is the use of voltage sensing module? and also where it should be connected i.e directly on the line or after the Active interface module?
@jasonwattsae9 ай бұрын
Thank you for being part of the community! The VSM will improve the performance of an Active Line Module's DC link regulation as it can more accurately measure the line voltage. The VSM10 needs to be attached to the line, between the contactor and the AIM.
@vorapobautomation97602 жыл бұрын
How to control 2 axis S120 synchronize with S7-1200 or S7-1500 PLC ?
@jasonwattsae2 жыл бұрын
I have an application that I am working on in the coming months that deals with just this. Check back in the coming weeks as I will be starting to make more videos.