Very good explanation on configuring the EN2T or the comms module. Really appreciated you showing the dip switch reset. You are very through and you know, that’s very important and appreciated. I learned and still learning the hard way in automations but I came from process operations to automations so I understood the process controls. I started in automations by knowing almost nothing though I knew what a plc and modules all were. But it was hard with no explanation of how anything worked working with a very good Senoir Programmer. I learned slowly over time all on doing old plant upgrades at power plant sites and learning ControlLogix with Studio 5k. I have access to almost every RA software from their toolkit and on my laptop for field stuff. However, knowing and understanding how stuff works and software and the details like your explaining is fundamentally important. Not many places or even KZbin channels really explain RA Software in details or how to really program stuff in clear clarity. In programing engineering it’s important to be clear and understand how to do what or why. Your demonstrating that very well here in these videos. Loved it. These days it’s FactoryTalk Linx Software, Classic still exist
@craigquary40172 жыл бұрын
Great content and love the excellent detailed instruction for the IP addressing configuration. Thanks for sharing.
@captainm5911 Жыл бұрын
Thanks for your detailed explanation. Very much appreciated!
@FaisalIqbal-yn7ug2 жыл бұрын
This guy is a legend. Thanks for all the good work mate.
@thirushaa4 жыл бұрын
Your videos are awesome , thanks to great teacher.
@nealneethling70402 жыл бұрын
Thank you my dude you helped me alot
@SolisPLC2 жыл бұрын
You're welcome Neal!
@Noxwill-lliwxoN3 жыл бұрын
Yeah! Thx You! Very Good information
@SolisPLC3 жыл бұрын
You're welcome! We're glad you found it helpful.
@PLCprogrammer5 жыл бұрын
Thank you for the informative video.
@SolisPLC5 жыл бұрын
Than you!
@ВалерийВодолазкин-м5с3 жыл бұрын
Thanks for the video .
@SolisPLC2 жыл бұрын
You're welcome!
@ussamasajid84094 жыл бұрын
Your videos are amazing man! Pl do a video on firmware updates and related issues as well. :-)
@wssameera5247 Жыл бұрын
Very helpful. Thank you..👍
@dhavalpatel7289 Жыл бұрын
🙏 🙏 🙏 thank you very much sir
@pratikgiridsy-is49314 жыл бұрын
thank you so much sir for this perfect teaching.
@SolisPLC2 жыл бұрын
You're very welcome!
@jgomez75356 ай бұрын
Great stuff
@peternjoroge62182 жыл бұрын
Great job.Nice Explanation.I am looking for a topic on PlantPAx
@lastnameavailableok3 жыл бұрын
excellent
@typeer2 жыл бұрын
thanks for this
@channelsaayana4780 Жыл бұрын
👍
@azeemahammed86463 жыл бұрын
Could do you make videos on the Serco communication module like this? if possible include a kinetics drive as well?
@xMini-_-Licx8 ай бұрын
Hello, a noob question, so this method you are doing is changing the Public IP address (Plant) correct? Or the private IP address (Machine)? Either way, thanks so much!
@mattraymond29355 жыл бұрын
THANKS can you do setting up word communication between PLCs?
@SolisPLC5 жыл бұрын
What do you mean by "word communication"? Do you mean passing strings?
@mattraymond29355 жыл бұрын
@@SolisPLC yes
@denischiasson75293 жыл бұрын
What is the main difference between the EN2T and the EN2TR? I know it has an embedded switch on the EN2TR, and I believe that it has two separate IP addresses are available, Thanks for the video - good content!
@SolisPLC3 жыл бұрын
There are 2 main items: 1. The 2 IP capability as you pointed out. 2. The ability to use DLR (Device Level Ring) which allows for "more reliable" networking of field devices by creating a loop from two points of connections. DLR is good in certain cases and I've seen good implementations of it in the field. My advice is to always purchase the EN2TR version unless there's a significant cost increase of one over the other.
@T---dq2qv7 ай бұрын
oh , can i set 256 to set the enthernet ip of this module , instead of the same you 000 ? this is because 256 is out of range the fist box 001-254 ?
@UmeshKumar-wt2yo Жыл бұрын
Good Content..What is the reason only if PLC is not reachable from scada server although the same is reachable to all???Can you please share your brief checklist on this issue?
@SolisPLC Жыл бұрын
It's either network configuration or PLC / SCADA configuration. I'd probably start with the one that isn't accessible by other devices and see how it's configured, if the physical connection is correct, try to connect it to a single other device, etc.
@madhusudhan89329 ай бұрын
In settings 000 is not taking un protected. Change switch settings coming
@suriyat8773 Жыл бұрын
PLC AB thank you
@nutankumardharsandia13984 жыл бұрын
Can you pls share how to connect absolute encoder to plc video
@kolyangod27155 жыл бұрын
Hello! do you have any lessons in Russian? Thx
@SolisPLC5 жыл бұрын
I don't, but I'd love to have them translated.
@kolyangod27155 жыл бұрын
That would be great!!! P.S. Thank you for your lessons!! They're great!
@АндрейСидоров-ц3ж5 жыл бұрын
I think you could this much with out factory reset with switches, and something was wrong after disabling with bootp rslinx must show you static.
@SolisPLC5 жыл бұрын
You are right, but I had someone email me about an ENET card that doesn't have a display. I wanted to demonstrate that the factory reset is an option in that case. BOOTP always had many problems from my experience. Things aren't always showing the way they should. That being said, I've always followed the same steps and things do work out. It's a matter of going through it a few times.
@rosendolopez20144 жыл бұрын
Hi Solis PLC, our factory recently got a new Internet setup my Ethernet/IP card on my Chassis is showing a ip of 192.168.1.xx but our new ethernet ip address is 192.168.201.xx what is the best way to change this so i can communicate with my Logix 5555?
@SolisPLC4 жыл бұрын
You can change it via RSLinx and that would be my recommended option. Simply add the current IP of the card into the IO tree, go into properties, and change it in the network tab.
@robertledford7994 Жыл бұрын
Your videos are great! The only advice I would have is to speak slower, and don't click through the process so rapidly.
@bendylee8604 жыл бұрын
Can I have this software? Thanks
@SolisPLC4 жыл бұрын
We can issue a quote.
@bendylee8604 жыл бұрын
@@SolisPLC how much?
@SolisPLC4 жыл бұрын
@@bendylee860 It's around $8,000 USD / year license for Studio 5000.