Very good video on mod for Sonoff Basic. I just completed the same for my Basic RFR2. Now, I have it attached to my GDO and can also use a 433 MHz remote to open/close the door. Of course it also have voice and manual operation.
@kimhammerum1322 жыл бұрын
Good safety - much apprecierede you making the video available for us. Thanks buddy...!
@JmChannel254 жыл бұрын
I like your method. Moving the fuse makes this mod much safer. 👍
@smartassan4 жыл бұрын
That was a really clear explanation. Thank you.
@richardbijlard50924 жыл бұрын
Excellent demonstration...helpfull! thanks!
@AdvancedTech2sharp4 ай бұрын
After Modification, to which terminals will the Motor be connected ( Relay Terminals Or the Initial Output Terminals)?
@cloudsuck4 жыл бұрын
Suggestion for a slightly simpler way to do this mod. All of these steps are done on the non-component side of the SonOff Basic R2. 1) De-solder relay output wire to Neutral terminal (as you did). 2) Cut entirely through the pc board/trace at the point that is common between the fuse lead, and the relay output lead. 3) Route the de-soldered relay output wire from "step 1)" into the pc board's corner notch, and solder it to the relay output solder pad from "step 2)". Confirm that there is no continuity between mains/input terminals and output terminals. No need to drill holes, or relocate the fuse. Just one through cut of the pc board.
@erdemgin3 жыл бұрын
video?
@emanuelortiz36673 жыл бұрын
Video?
@hotrex77792 жыл бұрын
Thanks for this feed back I will have a look next time I modify one. And try this see if I Like it Thanks
@cloudsuck2 жыл бұрын
@@emanuelortiz3667 kzbin.info/www/bejne/sKHYe2B4pampprc Or kzbin.infoY-3EADnFtZ8
@kaib92032 жыл бұрын
The best comment of all. One more modification: no need to desolder relay output wire. Just clip at the base. See modified pc board: drive.google.com/file/d/1f8e6tSo0xO5eKkBqah9tm0bMX9CBDVor/view?usp=sharing
@AdvancedTech2sharp4 ай бұрын
Which of the Sonoff requires no Modifications?
@NikAtFL3903 жыл бұрын
Hi Skipp, Hope this finds you well, My 6 month old Sonoff basic R2 konked off ... I tried changing the relay, but it will not budge, it will not come back on (sadly the original relay broke off while desoldering it out) (Also there is no glass fuse, its seems to be a 5 band 10 Ohms 5% resistor in its place inside a heat shrink tube).. Anyhow Funny though 5 other Sonoff basic R2's switches have been working for over three years perfectly well ... And this new unit circuit broke and I cannot figure what component has popped. ... I'd be totally thankful if you could guide me on how to fix this.
@hotrex77792 жыл бұрын
Sorry. Late reply. I have to date not had to repair any of my devices . So can’t realy say what fails. Normal checks would be to test for voltages at the chips and the relay driver device
@lucclaes62703 жыл бұрын
Why modifie the Sonoff? Just add a extra relais (110 or 230V) at the output for the same result.
@hotrex77792 жыл бұрын
True. Some ppl have done this too . But for me I use this way to keep things simple and under one cover. I only drive external relays and contactors. If I need to control a larger current load . But I would advise ppl to do what they feel comfortable with and understand.
@martinvrabec47014 жыл бұрын
is it possible to operate also 230V on the output?
@hotrex77792 жыл бұрын
If you mean to control an external 230 v signal from some other device. Yes you can Note if you are switching. Dc. Then the current limit needs to be reduced. To prob only 2 amps it less
@emanuelortiz36673 жыл бұрын
Can I used this modification to run a 12v dc motor?
@hotrex77792 жыл бұрын
This. Gives a volt free contact that you can use to control any other device by controlling an external voltage source. Just be aware of the Amps limitation of the relay I would myself only run these relays at 50% load. For a longer life.