How Many Conductors Can Be Put in a Pancake Box by 2020 NEC? (Box Fill Article 314.16)

  Рет қаралды 29,081

Sparky Channel

Sparky Channel

Күн бұрын

Пікірлер: 122
@wmcomprev
@wmcomprev 3 жыл бұрын
You made the comment that we were assuming the ECG inside the box to be 14 AWG, but that it was 12 AWG and could be considered as causing us to exceed the volume calculation. However, as you also showed, 314.16(B)(5) says that the calculation will be made on the largest "entering the box." The ECG that comes preinstalled in the box does NOT "enter the box."
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks for bringing that up! I edited out that section with KZbin editor. You helped me make it a better video! Merry Christmas. 🎄
@Ed-uu9eo
@Ed-uu9eo 3 жыл бұрын
I was about to say this. I don't think that article counts the pigtails to base the calculation on.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
@@Ed-uu9eo Thanks and Merry Christmas! 🎄
@michaelmartin5995
@michaelmartin5995 3 жыл бұрын
Bill, Merry Christmas to you and your family. Still one of the best channels on YT!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks so much Michael! Merry Christmas. 🎄
@WeatherNut27
@WeatherNut27 3 жыл бұрын
Really enjoying these videos referencing the code book and reading it with us. Thank You!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks so much! Merry Christmas. 🎄
@bksamander
@bksamander 3 жыл бұрын
When a fixture is connected to a pancake the space it provides for wire connections should be taken into account when calculating max fill values. 314.16 (A) Box Volume Calculations. The volume of a wiring enclosure (box) shall be the total volume of the assembled sections and, where used, the space provided by plaster rings, domed covers, extension rings, and so forth, that are marked with their volume or are made from boxes the dimensions of which are listed in Table 314.16(A).
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks! Merry Christmas. 🎄
@MikeSully01
@MikeSully01 3 жыл бұрын
I think the only thing an inspector could get you on with that one is the "that are marked with their volume" most, if not all fixtures aren't, even though I agree they should count.
@patriciamoraga2917
@patriciamoraga2917 3 жыл бұрын
Thank you for sharing all of this info.. you have amazing classes........and if i miss something i just rewind your video...
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Glad you like them! Happy New Year Patricia!
@patriciamoraga2917
@patriciamoraga2917 3 жыл бұрын
@@SparkyChannel a Happy New Year to you as well......!!!
@SuperVstech
@SuperVstech 3 жыл бұрын
Code says largest grounding conductor ENTERING the box. The #12ECG is contained in the box, it does not enter the box. So, it doesn’t count.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Yes, that's true. I deleted the part where I was talking about the 12g ECG. Merry Christmas! 🎄
@iandrew6347
@iandrew6347 3 жыл бұрын
Great video again Sir Just like to say Merry Christmas or Happy Holiday Stay Safe Watching from the uk 🇬🇧
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks Ian! Merry Christmas. 🎄
@drexrew
@drexrew 2 жыл бұрын
Why would you have a separate grounding wire for the box ground screw, just wrap the bare copper ground wire around the screw and then connect the device ground to the wire. No need for an extra wire.
@Jason_Canada
@Jason_Canada 2 жыл бұрын
3 conductors but really its a 14/2 with marettes
@Jason_Canada
@Jason_Canada 2 жыл бұрын
Smack that box ...Bill
@Jason_Canada
@Jason_Canada 2 жыл бұрын
Personally I would of used the bond wire around box screw then the green to the wiggee
@Jeff-Lawrence
@Jeff-Lawrence 3 жыл бұрын
Hi Bill from Sparky Channel Exceptional video as usual This was a really good one, had to read that code twice. They sure make those definitions confusing. Thanks again, really appreciate your hard work making these videos. Merry Christmas
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Sometimes I think they make the code confusing on purpose. LOL! Merry Christmas! 🎄
@stevenneuberger4323
@stevenneuberger4323 3 жыл бұрын
I wonder if an inspector might look at that "bushing" as being an internal cable clamp (314.16(B)(2) which I believe would bring the required space to 8.25
@SparkyChannel
@SparkyChannel 3 жыл бұрын
They might. The actual truth is that inspectors might say just about anything. But most of that clamp is outside the box so just about everybody would agree that it's an external clamp and not counted. Also, there is a picture in the 2020 NEC handbook with a set-up just like mine. Good question. Merry Christmas! 🎄
@Shadi2
@Shadi2 3 жыл бұрын
I like Saddle or L shaped fan boxes. Much more CU (12 & 16).
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Yes, excellent point. Merry Christmas. 🎄
@luktish
@luktish Ай бұрын
Anyone knows some video showing which type of light fixtures count into the total box volume, which don't?
@DarkD112
@DarkD112 Жыл бұрын
Thankfully, CEC is much nicer. We only count insulated conductors, so the ground is out. And #14 AWG only uses 1.5 cubic inch per insulated conductor. Although, we have a rule that counts every two wire-caps as an insulated conductor. So our fill only goes up to 4.5 cubic inches. Also, where are you getting 6 inches from for pancake boxes. The number I googled says they're 5.5 inches cubed.
@stevelopez372
@stevelopez372 Жыл бұрын
Now it is. Was not so nice in previous code cycles. Of course I have been retired for 3 code cycles,Lol.
@luvdady
@luvdady 4 ай бұрын
It's stamped on the box
@billybilodeau1991
@billybilodeau1991 3 жыл бұрын
Why use a bonding jumper when you can wrap the romex bonding wire around the green screw it’s self? Even if we used a 14 awg jumper and don’t have to count it, it still does take up some room. I also like using small orange wire nuts in that situation because they are smaller then the wagos. We don’t have to figure them in for box fill code wise but in reality they do take up room and depending on the fixture bigger wire nuts or wagos can get in the way.
@kenbrown2808
@kenbrown2808 3 жыл бұрын
I agree. I'll also have to double check when I get my handbook, because I prefer the 3.5" pan box, which is only made legal by the volume of the fixture canopy, so if they've started to prohibit adding canopy volume, I'll have to find another way to get box volume without cutting into my margin of error by using 4 inch boxes. also, if you haven't played with them, I like the 3M O&B wire nuts for connecting fixtures in close quarters.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
That's a good technique which does save space. Merry Christmas. 🎄
@billybilodeau1991
@billybilodeau1991 3 жыл бұрын
My boss, as I was an apprentice, never let use use 3” pancake boxes and so i still don’t. Usually fixtures thar require a small splice box NEED a metal 1gang box, because of the size and shape of the canopy. I’m always surprised they are allowed to make such fixtures seeing as how there’s no boxes technically rated to hold them. (As far as i know) And I’ve never seen a 1gang metal mudring tapped for 8-32’s...that would be great lol
@billybilodeau1991
@billybilodeau1991 3 жыл бұрын
Merry Christmas Sparky
@lockpickingvlad
@lockpickingvlad 2 жыл бұрын
That’s how I do it. 👍🏻
@nickm9123
@nickm9123 3 жыл бұрын
in nj, that could fail in new con. if the inspector is a jerk, because we have to have allowances for "future work" i.e, you cant meet box capacity, you have to have a minimum of 1 cubic inch extra.
@kenbrown2808
@kenbrown2808 3 жыл бұрын
years ago, I had an inspector tell me that if everything is folded in neatly, and there is obviously plenty of space for the devices or fixture connections, he wasn't going to be bothered counting conductors. which was a relief because the box he was looking at was at its maximum conductor fill.
@playnationtoday
@playnationtoday 3 жыл бұрын
That’s kind of crazy! 1 cu. in. Won’t get you anything more than what the box already allows!
@dougthoutt
@dougthoutt 3 жыл бұрын
Great video on pancake boxes. Do cable clamps not count against the capacity of the box?
@kendrickkimble9763
@kendrickkimble9763 3 жыл бұрын
This guys the best. Learned so much from him.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks Kendrick!
@--JohnDoe
@--JohnDoe 3 жыл бұрын
I learned "new update" you also add a 1/4 volume allowance for each additional e.g.c. Thank you.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Yes, that's the new update. I'll be using that update in a future video. Merry Christmas. 🎄
@--JohnDoe
@--JohnDoe 3 жыл бұрын
@@SparkyChannel Merry christmas bill.
@tedmcdonald3377
@tedmcdonald3377 3 жыл бұрын
Merry Christmas Bill, thanks for the videos!!!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks Ted! Merry Christmas. 🎄
@michaelc.3812
@michaelc.3812 3 жыл бұрын
This wouldn’t be acceptable for ceiling fans with a 14-3 NM cable, not for any daisy chain lights. Just a single run of 14-2. Of course the new 2020 ceiling fan box requirements apparently rule this box type out.
@Sparkeycarp
@Sparkeycarp 2 жыл бұрын
How many times have you opened up a pancake box and seen a splice going to another place? Especially bathrooms.
@jamiedrover6192
@jamiedrover6192 Жыл бұрын
I was hoping this would work to center a bathroom light. It wont pass because theres a splice going somewhere else No wires are allowed to exit. Is that correct?
@torodaman
@torodaman 3 жыл бұрын
What I do so it could be less busy with wires in the pancake bx, No ground pig tail install in the bx, I leave the ground wire extra long and just wrap it on the ground screw with 5 inches long b4 the screw and wrap it inside along the edge of the bx out of the way and 6 inches after, and you eliminate an extra pice of wire and make it roomier in the tiny bx, but to answer ure question, only one wire in the pancake bx.
@Nick-bh1fy
@Nick-bh1fy 3 жыл бұрын
Btw bro “bx” also refers to an armoured cable not box
@stop2kare472
@stop2kare472 3 жыл бұрын
I believe he did that for demonstration purposes only. I'm sure he's out in the field doing good work👍🏽
@JohnBGood-kq3ul
@JohnBGood-kq3ul Жыл бұрын
Thanks for the very informative video. Direct an to the point. Great job as always.
@SparkyChannel
@SparkyChannel Жыл бұрын
Thanks John!
@chrisharper2658
@chrisharper2658 2 жыл бұрын
It looks like your ground pigtail may actually be #12 AWG so wouldn't that push you over the 6.0 CU INCH limit or does the pigtail not get counted? Seem odd that because of the regs, using #12-2 wouldn't be allowed even though the biggest issue with those boxes is fitting the wire nuts into that tiny space and not the air gap around the wires. Those flat Wago lever-nuts sure are a big help and yet they're not required.
@jamesalvin5735
@jamesalvin5735 2 жыл бұрын
You're right that the pigtail is #12, but 314.16(B)(5) says that the calculation shall be based on the largest conductor "entering" the box, which would be the bare #14. The "entering" distinction was added in the 2020 edition, so if you're using an older edition, that would explain your confusion 🤙
@joer9276
@joer9276 3 жыл бұрын
So we don’t have to count the cable clamp in the pancake box but do on the ones molded into the blue nm boxes? Makes sense? Merry Christmas!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
The blue NM boxes with the integral clamps are quite controversial as to whether they would need to be counted as internal clamps. My internet search came up with about 50% yes and 50% no for people's opinions on that. Merry Christmas! 🎄
@canadiantrucker9574
@canadiantrucker9574 3 жыл бұрын
As many as you can possibly cram into the box?
@SparkyChannel
@SparkyChannel 3 жыл бұрын
LOL! Merry Christmas. 🎄
@canadiantrucker9574
@canadiantrucker9574 3 жыл бұрын
@@SparkyChannel Merry Christmas to you too Bill, have a blessed holiday season
@--JohnDoe
@--JohnDoe 3 жыл бұрын
Bill I think your box fill is 6.0 not 6.25. It says "entering the box" that 12awg grounding pigtail originates from that box, it doesn't enter it. Am I wrong?
@SparkyChannel
@SparkyChannel 3 жыл бұрын
You are correct. I edited my video taking out the part about the 12 ga EGC. I learned a good one there! Merry Christmas. 🎄
@HashBandicoot356
@HashBandicoot356 Жыл бұрын
So if you had 2-4 grounding conductors it is still 2.00 cu In, but if you had 5 it would be 2.5 cu in.?
@mae2759
@mae2759 Жыл бұрын
Yes.
@Arieeeee
@Arieeeee 3 жыл бұрын
Awesome video! This must be the biggest code violation in the world because it means that even a single 12/2 wire will go over the 6 cubic inch limit and yet I've seen it all the time and may or may not have been guilty of committing it myself! I guess your alternative there is those NM fan boxes that let you screw directly in the jost but even those only have 12 cubic inches of capacity.
@KitchenerLeslie2
@KitchenerLeslie2 3 жыл бұрын
Some of my coworkers use those for regular fixtures in place of pancake boxes. They stink. All the extra plastic interferes with most fixture brackets.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks and Merry Christmas! 🎄
@sledge3003
@sledge3003 3 жыл бұрын
Thanx for another great video!!!.....merry Christmas and all the best in 2021!!!
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks! Merry Christmas. 🎄
@thunder3470
@thunder3470 3 жыл бұрын
Thank you even for your gift of explaining things
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks and Merry Christmas! 🎄
@junyue678
@junyue678 2 жыл бұрын
It is so useful, thank you very much!
@WeatherNut27
@WeatherNut27 3 жыл бұрын
The last paragraph new to 2020 is throwing me off. What does "based on largest" mean? If we had 12-2 conductors in the pancake box and the additional ground was 14-2 does that mean we dont add that 1/4 volume?
@kenbrown2808
@kenbrown2808 3 жыл бұрын
it means you count the first four grounding conductors as 1 conductor count of the size of the biggest. say you have a #12, a #14, and a #18, like in his example, you would count them all as 1 #12. if you had a multigang switch box with 6 #14 grounding conductors, you would count the first 4 as one #14, and then count the next two as two quarters of a conductor count,
@jgoddard0757
@jgoddard0757 3 жыл бұрын
Noticed in the last couple vids youre wear HD gorilla gloves. Are you wear these at work? I do and find they give excellent dexterity and feel while protecting my hands.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
I like them because they protect my hands from little scrapes and they give a good grip on things. They're nice little gloves IMO. Merry Christmas. 🎄
@philiphorner31
@philiphorner31 2 жыл бұрын
Pancake box will need a bump on backside to carry 12-3 or 14-3.
@markmadlena6009
@markmadlena6009 3 жыл бұрын
One wire. Or two or three if the inspector doesn’t catch it.
@billrutledge2962
@billrutledge2962 2 жыл бұрын
Bill. Can send me a link to the white light fixture you used in this video. I have been looking for a light fixture like that
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Hi Bill! It's just a cheap porch light that I bought at Home Depot. They used to cost $5, now they probably cost $10.
@Eddy63
@Eddy63 3 жыл бұрын
Good 1 Wild Bill ... Merry Christmas to you and the NEC Code people ... Lol ...
@SparkyChannel
@SparkyChannel 3 жыл бұрын
LOL! Merry Christmas. 🎄
@philipbieniecki3819
@philipbieniecki3819 3 жыл бұрын
Good job 👍
@MikeBramm
@MikeBramm 3 жыл бұрын
Merry Christmas Bill and family.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks and Merry Christmas🎄 to yourself and family!
@garydudgeon
@garydudgeon 3 жыл бұрын
Good explanation Sparky.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Thanks Gary! Merry Christmas. 🎄
@MrTooTechnical
@MrTooTechnical 3 жыл бұрын
Woohoo. Merry Xmas
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Merry Christmas Dave. 🎄
@sfnsfn6628
@sfnsfn6628 3 жыл бұрын
If the light canopy (domed cover) is marked with a box fill volume, can that be added to the pancake box fill volume to give a total increased box fill volume?
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Yes. But it's unusual to find a canopy or doom that is listed and labeled for wire fill. Merry Christmas! 🎄
@andydelle4509
@andydelle4509 3 жыл бұрын
So basically you can't use #12/2 with a pancake box period? I'll bet that get's very lightly enforced.
@Nick-bh1fy
@Nick-bh1fy 3 жыл бұрын
Typically you won’t even use a pancake unless for a keyless fixture
@clayadams2068
@clayadams2068 3 жыл бұрын
We use pancakes for almost all surface mounted lights unless center comes out on the edge of a joice.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
You're correct. 12/2 with ground wouldn't work. Merry Christmas! 🎄
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Gotta love keyless fixtures! The old gas fixtures had keys so the invention of the electric lights were "keyless". Merry Christmas! 🎄
@crazycomments2.178
@crazycomments2.178 Жыл бұрын
@@SparkyChannel What if you run type AC cabling back to the the previous box, and ground the the fixture directly to the box? So you have 0 grounds, 2 #12s, and 3 omitted fixture wires
@aldavison420
@aldavison420 2 жыл бұрын
Can we surface mount these pancake boxes?
@philiphorner31
@philiphorner31 2 жыл бұрын
So we can't use #12 wire. Rediculous
@SparkyChannel
@SparkyChannel 2 жыл бұрын
Yep.
@kirkshirley1319
@kirkshirley1319 3 жыл бұрын
If hickeys and nipples each count as one conductor then you forgot to include the threaded nipple in your total. Pancake boxes that come with the metal cable clamps inside should now be delisted or exempted in the code.
@yzmoto80
@yzmoto80 3 жыл бұрын
Hmm, 14-3 w/ground NOT allowed in a 6 cu. in. pancake box.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
That's correct.
@chaseoes
@chaseoes 3 жыл бұрын
Can you make a video about interconnected smoke detectors?
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Yes, I'm planning on it. Merry Christmas! 🎄
@alsentman9390
@alsentman9390 3 жыл бұрын
I was under the impression that the "conductor" consisted of the hot and neutral wire. Please correct me if I'm wrong. Currently reading and watching videos to learn electrical.
@captainteamcarry3
@captainteamcarry3 3 жыл бұрын
Copper wire or green wire is the grounding conductor.
@jamesalvin5735
@jamesalvin5735 2 жыл бұрын
Both the hot wire and the neutral wire are current carrying conductors. They each count as one.
@williambarry4693
@williambarry4693 3 жыл бұрын
There needs to be a simpler explanations.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
I hear you.
@tevman69
@tevman69 3 жыл бұрын
Math, does not lie.
@SparkyChannel
@SparkyChannel 3 жыл бұрын
No, it sure doesn't! Merry Christmas. 🎄
@wolfworrier3169
@wolfworrier3169 3 жыл бұрын
? Sir what problems could you have at home for your utility bills to keep going up ?.could it be wiring
@mikeeat7918
@mikeeat7918 3 жыл бұрын
To much stuff on large appliances don’t think the wiring could have anything to do with that. How big is your house?
@SparkyChannel
@SparkyChannel 3 жыл бұрын
Utility Bill problems are usually from heating (including heating food) and cooling (including cooling food). LED lights have dramatically reduced utility expense from home lighting. Wiring is not usually an issue. Merry Christmas. 🎄
@wolfworrier3169
@wolfworrier3169 3 жыл бұрын
4 rooms
@stevenneuberger4323
@stevenneuberger4323 3 жыл бұрын
I suspect restrictions due to the COVID-19 pandemic might contribute.
Do Pancakes Violate Code? How Many Conductors can ACTUALLY Fit?
11:47
Is this Box Overfilled by 2020 NEC Code?
11:17
Sparky Channel
Рет қаралды 147 М.
Doing This Instead Of Studying.. 😳
00:12
Jojo Sim
Рет қаралды 34 МЛН
Бутылка Air Up обмани мозг вкусом
01:00
Костя Павлов
Рет қаралды 2,7 МЛН
Кадр сыртындағы қызықтар | Келінжан
00:16
Harley Quinn's plan for revenge!!!#Harley Quinn #joker
00:49
Harley Quinn with the Joker
Рет қаралды 32 МЛН
Quick "Cheat Mode" Box Fill Calculations with 2020 NEC
5:43
Sparky Channel
Рет қаралды 29 М.
How many Amps to burn up 14/2 electrical wiring?
11:45
Electromagnetic Videos
Рет қаралды 546 М.
Can MC Cable be Run Unsupported Behind Walls by 2020 NEC?
5:59
Sparky Channel
Рет қаралды 67 М.
Understanding Article 314.16 NEC Calculation Part1
13:57
Salvatore Ferrara
Рет қаралды 1,4 М.
How Many Wires Can Fit in Each Hole?
6:23
Electrician U
Рет қаралды 238 М.
How To Ground A Metal Box With And Without A Green Pigtail
10:07
Why Not DIY
Рет қаралды 22 М.
Determining the Number of Conductors | Box Fill Calculations
8:54
Master The NEC
Рет қаралды 1,8 М.
Doing This Instead Of Studying.. 😳
00:12
Jojo Sim
Рет қаралды 34 МЛН