Always nice when the customer tidies up for you when they know you’re coming….🙄 What a tip!!
@truthseeker77942 ай бұрын
I think they're just moving in or renovating or both. You can see all the new doors and materials and you can see a guy erecting scaffolding at the back. It's not really important is it. I bet you're one of those annoying people who spends all day Sunday jet washing everything.
@rayc15033 ай бұрын
Delroy's a genuinely decent guy. He receives a lot of critism. Either way he's earning and has repeat custom. So I guess he must be doing something right. Atleast he has the courage & ability to put content out there. Gbu & keep the content coming Del.
@eastwayelectrical3 ай бұрын
Thanks for watching criticism doesn't worry me.
@bethanyschool3 ай бұрын
Well said. 👍
@ef74803 ай бұрын
Could you not just have terminated the glands of the SWA directly into the sides of the socket enclosures? ...just an obsevation.
@shaniapearcey3 ай бұрын
Why has he not done it like so 😏
@Nick_Carlos3 ай бұрын
I think he was thinking that entering into the bottom would be better due to water ingress potential however I'd probably of gone in the side as that's more work for not much gain in my opinion but everyone does things differently!
@eastwayelectrical3 ай бұрын
I don't do it that way if I can avoid it. Like I've said numerous times things I do are based on previous experiences. when I install lights sockets etc in a straight line like this. I try to avoid passing the wiring through the fitting, because at a later date you go to change that item you have to get the exact same fitting to fit in that space. Depending on the span of time you may not be able to get one or you may get the same make but there are slight changes that prevents it fitting in the original space with this method you can install any fitting. Also is easy to terminate the cables into the box underneath if one has to be removed for a period of time.
@ef74803 ай бұрын
@@eastwayelectrical - Thanks Delroy. It’s always good to see different peoples methods so fair comment. 👍🏿
@mx97jb5 күн бұрын
I’m a sparks, and I really like the way you have used the galv boxes and the reason why. You can’t buy experience so thanks for sharing the tip Del. This would’ve been one of them jobs where I turned up to and thought I wish I quoted a little more 😂😂
@albertharmon27383 ай бұрын
Should have let Ken sort it out 👍🏻
@NK-vd8xi2 күн бұрын
Delroy this might be a weird question but, i think you'd make a lot of money on her if you made another channel where you take these vids, get rid of the music and loud noises, and market it is Unintentional ASMR. The way you work and the way you talk is very soothing.
@fireblaster99613 ай бұрын
Why not run the cable through the sockets for a cleaner look
@HA05GER2 ай бұрын
I like the wago mk sockets. My house has got the old stranded copper and they are a pig to spur off so having the extra ways make it far more easier to spur.
@CommercialGasEngineerVideos3 ай бұрын
Had to do armoured cable to pass my electric level 2 exam. Nice and simple once you know how
@TheGorillahands3 ай бұрын
20mm conduit with t&e, conduit straight through the 1st socket, less work looks better and no need to mess about glanding , just my opinion .
@eastwayelectrical3 ай бұрын
you can do it anyway you like thanks for watching.
@PearsallEu3 ай бұрын
I'd prob use the junction below too, but I agree with t/e conduit. Faster, and cheaper
@seankay81373 ай бұрын
If that's a BG outside socket, those 20mm push out plugs are not waterproof as I have found out. They need to be pushed out and silconed back in, especially the top one's.
@eastwayelectrical3 ай бұрын
I use MK or Schneider. thanks for watching.
@AbdulHalim-io7pd3 ай бұрын
Excellent video....😊
@Spark101.3 ай бұрын
Those sockets don't require. sealing with mastic if installed correctly mate......especially with bottom entry
@001Neal1003 ай бұрын
Get yourself a marxman pen, drill out the back of all 4 mounting holes on the socket, put the socket to the wall level, then push the pen into each screw hole and it will mark the wall so you can do all the drilling at once and then you don't have to fit it twice 👌
@eastwayelectrical3 ай бұрын
I have one of those. On this occasion with these boxes to get them precise I find it better to drill the first corner get that fitted and level then drill the other 3 through the box that way it's sure to be level. With your method when you start the drill on hammer it can slip slightly and when the box is fitted it's out(not level).
@eastwayelectrical3 ай бұрын
Thanks for watching.
@PearsallEu3 ай бұрын
@@eastwayelectricalI never start the drill on hammer if it matters. New bit/ hammer and punch to make sure the bit can't spin off
@dennisreid44283 ай бұрын
Not a chance I'd have used the consumer unit in a state like that. rip out and start again. not even sure how those bus bars have been fitted?
@Nick_Carlos3 ай бұрын
What if the customer doesn't want to pay for a new consumer unit? We have to earn a living what would you do walk away?
@dennisreid44283 ай бұрын
@@Nick_Carlos I'd be more concerned about those bus bars not being connected properly and starting to arc.customer said only outside light's would be on the circuit,how would you know how much future higher loads wouldn't be introduced to that circuit? I'd have waked away. wouldn't put my name to that installation
@Nick_Carlos3 ай бұрын
@dennisreid4428 Must not of been paying attention to be honest that's a fair point!
@dennisreid44283 ай бұрын
@@Nick_Carlos If you look closely the bus bars are over lapped,with the new one just touching the original. have a look at around the 3 minute mark. then you'll realise why I'd have suggested ripping it out or walking away
@PearsallEu3 ай бұрын
@@dennisreid4428 just get a new bus bar. I'm sure we've all got one or two from old installs in the shed. I keep a few old mcbs, bus bars etc just in case I can't get one when I need it...
@brighton_locksmith3 ай бұрын
5:29 hey Delroy. What is the name of this song you often play please? Keep up the good work 😊
@SwiftHelixАй бұрын
My World - Shima
@tonyaziz88202 ай бұрын
I heard it delroy😂
@ashleybignell23663 ай бұрын
Always nice to see different working practices. What was the reason of using swa over something like H07? i could understand if you were burying the cable.
@tommochelsea723 ай бұрын
Would loved to have seen how you made the swa off in the plastic consumer unit. Bet that rcd was a type AC
@Nick_Carlos3 ай бұрын
What's wrong with a type AC RCD there's that's all that's required by BS7671
@MarkSmith-nt8tb3 ай бұрын
Also the armored was going into a fused connection unit first so he didn't need to gland it into the board
@PearsallEu3 ай бұрын
Why didn't you just get a new bus bar and install a new RCD. Also isn't it considered a radial from the cu... Meaning if it's on a 32a then that's where the grey areas start...
@sdgelectronics3 ай бұрын
@@PearsallEu No, it's still a spur. But nothing stopping you spurring in 4mm cable for multiple socket outlets.
@PearsallEu3 ай бұрын
@@sdgelectronics I'm not so sure... The main issue is you can't spur from a spur because you can overload the cable. You don't know how many sockets are in the chain. And if it's a 32a ring is not gonna trip the MCB until well past the list capacity of the cable... A single socket is rated at 20a... (Ironically near the same as the 2.5mm) There's nothing that specifically says you can't run a radial and ring off a single MCB... Even though not ideal ... This is also one of the reasons I'd use conduit. & 4mm t/e. But it's possible the MCB is 20a anyway.
@gregcressey17913 ай бұрын
I would have replaced buzz bars n add another breaker to feed em
@strummer66423 ай бұрын
Nice job Delboy, is the box MK?, can't tell but the plastic lugs on mine cracked and broke off after a couple of winters, otherwise well made
@andyreed77953 ай бұрын
Did you replace the type AC rcd for the required type A ? (As all additional sockets require type A now)
@leoleorelated14 күн бұрын
Where did you see this?
@chrisardern45943 ай бұрын
Oh my days. Looks like the buzz bar was 2 ways to short so 3 were added 1 to piggy back of the existing buzzbar giving another 2 ways. The question should be how was the swa terminated at the consumer end as it seems the video finished prematurely. Or is their a part 2 comming.
@BritishEngineer2 ай бұрын
*bus *too *SWA *coming
@andysims49063 ай бұрын
Got the old gloves on again .
@andysims49063 ай бұрын
Those cleats look to far apart
@mrwhite73613 ай бұрын
I go 300mm spacing. The length of my hammer. Too far apart starts to sag and looks shite.
@imhemaster3 ай бұрын
Got lucky with that hole being there.
@raymyhill22773 ай бұрын
In the UK why dont they run the armoured cable in conduit would look better and quicker to install and less likely of damage.
@thesteve142gaming73 ай бұрын
Because the cable is already protected by the “armouring”
@PearsallEu3 ай бұрын
Conduit provides extra protection. AC doesn't need it. Plus it is strong enough to support it's own weight.
@TheChipmunk20083 ай бұрын
I don't get on with those MK lever connection sockets at all, they're too flimsy
@darknessdestroyer55243 ай бұрын
No need to seal the whole box, just behind each screwhole. Those conduit boxes WILL let in moisture, doesn't matter if you used a gasket, should've terminated the armours into the bottom of the sockets, how long is your labour guaranteed for? coz you're going to get a call back in a few years from those tripping the RCD.
@JorgeAMG1873 ай бұрын
Even if water gets in the conduit boxes. Why would that trip the RCD?
@darknessdestroyer55243 ай бұрын
@@JorgeAMG187 why are you commenting if you don't know what causes RCDs to trip?
@JorgeAMG1873 ай бұрын
@@darknessdestroyer5524 I know what causes RCDs to trip. And water in the conduit box sure isnt one of the reasons. You just trying to talk smack about Deltoy because you couldnt do it better yourself
@darknessdestroyer55243 ай бұрын
@JorgeAMG187 You obviously haven't got a clue about how a RESIDUAL CURRENT DEVICE operates, you're now making a fool of yourself, please carry on.
@JorgeAMG1873 ай бұрын
@@darknessdestroyer5524 You a clown. Clearly got no idea about electrics.
@spaggtrait16083 ай бұрын
Just out of interest, I am 50 years old now, and still to this day when I go to switch on at the fuseboard after a job, I always find myself thinking "let's see what happens eh?". Anyone else like that or just me?
@PearsallEu3 ай бұрын
What can go wrong... Will.
@dannyboisparky3 ай бұрын
That’s a board change all day long
@TB-qf3mn3 ай бұрын
100%, mismatched mcbs, broken cover, bodged bus bars
@kushalvijay60873 ай бұрын
Hi, I'd like some advice for a light installation that I want to do. I want to install a light that is very close to my consumer unit, but there are no sockets nearby where I could take a 3A FCU spur out of. Currently from my consumer unit, there is already an existing spur out of my immersion circuit breaker to a single socket which my wifi router is plugged into. My question is could I take a supply from this socket to a 3A FCU which I will connect next to this socket for which I could power the lights I want to install? Thanks in advance.
@davidkavanagh49663 ай бұрын
Hi, Never spur from a socket circuit to a lighting circuit. Even with a fused spur it wont pass regulations and can cause problems if anything were to happen down the line. Your best bet is to run a cable from your existing lighting circuit or run a new lighting circuit from the fuseboard. Thanks
@kushalvijay60873 ай бұрын
@@davidkavanagh4966Hi, thanks for your reply. In essence, there are basically two radials circuits coming out of one MCB (immersion). The single socket was already there so I don't really understand why I'm not allowed to spur a 3A FCU from that.
@benjaminives3973 ай бұрын
@@kushalvijay6087 There's nothing against this i'm not sure why you've been told otherwise. You can spur off a socket, just use a 3A FCU. This is how many garages are wired with sockets/lights.
@kushalvijay60873 ай бұрын
@@benjaminives397 Hi, even though that socket has been spurred off the MCB, it's okay? (It's like having two radial circuits coming out of a single MCB. Thanks
@PearsallEu3 ай бұрын
@@kushalvijay6087 the issue is about nuisance tripping of the MCB. I'm assuming the immersion is 20a MCB? In 2.5 mm you can run a multiple socket radial... But... Whilst the immersion is likely 13a give it take, it could trip... Depending on what's plugged in. 1.5mm clipped direct is good for 19a so a b16 is good enough. But. I wouldn't run a couple of sockets in 1.5 on a b16. It's common sense. What's likely to be plugged in there.
@BULLEAD3 ай бұрын
Can of worms
@Makerveli3 ай бұрын
SWA looks a bit unlevelled
@supernoodle483 ай бұрын
It looks like the curvature you get with a wide angle lens.
@user-gh2rk4st4o3 ай бұрын
Jesus the prices this guy charges I thought he was a baraster 😂
@looking91753 ай бұрын
Only Delroy can put a value on what time is worth to him, if someone's happy or not happy to pay those prices fine.
@PearsallEu3 ай бұрын
Well.... I know cheaper barristers than some sparks
@BeaconFTW3 ай бұрын
Have you got the wrists of a 2 year old just use a set of side cutters to strip the cables
@MarkSmith-nt8tb3 ай бұрын
He's 68 bro
@lukepovey6133 ай бұрын
Some one get this man off the tools FXXK my life yeeeeeeeehaaaaaaaaaaaa