Great 'LIVE' video shot on a neat Smart Solar installation. Evidence that SMART SOLAR is all about in-depth knowledge & intrinsic know-how what to do when it comes to install professionally. Top notch!
@zurriannetworksКүн бұрын
Appreciate the kind words!
@greatn2213Күн бұрын
Very neat installation man!
@zurriannetworksКүн бұрын
Thanks!
@anietienssien66432 күн бұрын
The use of ferrules or terminal blocks would be best in wire connections and cable terminations to avoid arcing.
@KossyUgwa3 күн бұрын
💯💯
@Resonance-n4h12 сағат бұрын
Hi, please kindly check your Inverter manual and confirm how you installed the white magnetic beads. The bead is to be installed on the either the live or the neutral lines. the way you connected it now is leading to the cancellations of magnetic field. Please kindly correct it when you visit next time.
@celestinaosokoya56762 күн бұрын
Great job 💯
@zurriannetworksКүн бұрын
Thank you 👍
@nzubegoodluck90563 күн бұрын
Good job 👍
@zurriannetworksКүн бұрын
Thanks! 🙏
@donlatinohits3 күн бұрын
is the grid the input in the AVR ?
@smallqwaro2 күн бұрын
Do you mind explaining why the inverter wouldn't allow the 300 you wanted and didn't you check the specs and calculate everything before the job? Also is the avr single or three phase?
@zurriannetworksКүн бұрын
The AVR is 3phase The max charging and discharging current for Deye 12KW is below 300A (around 290A there about)
@ernestsuper2 күн бұрын
I was wondering Why use 580w panels when there is 750w panels, won't you be using less of those and having more space to work with?
@zurriannetworks2 күн бұрын
580W was the biggest size available at the period of the project
@adisaazeez51492 күн бұрын
I am just curious! Will that building besides where the pv modules are being mounted not cast Shadow on them, hence reducing their optimal performance.
@adisaazeez51492 күн бұрын
2:37
@zurriannetworksКүн бұрын
The building will not, the carport on the north-south line.
@StepDoku3 күн бұрын
so you allow the batteries to be charged by the grid, what happens when the sun comes up? I thought you will just let the grid pass through without charging the batteries so the sun will do that in the morning or when the weather becomes OK for that? just wondering...
@zurriannetworks3 күн бұрын
So Deye does the charging priority automatically (based on your settings). In this particular site, I set the system never to use Grid for both charging & passing through from 6:00 to 21:00. You can alter these settings at will.
@StepDoku3 күн бұрын
@ I get it now In one of your settings shot I saw grid charging so I thought you left it at that…great work buddy
@titoraddingi5444Күн бұрын
What’s a roughly budget for the equivalent .
@zurriannetworks2 минут бұрын
22million naira
@oge36802 күн бұрын
This is a good job. What could be the cost of this 12kw with 30kva lithium battery, please?
@zurriannetworksКүн бұрын
Approximately 22million Naira
@ayodeleojetunde61833 күн бұрын
Please can you send me a link of where you get your enclosure boxes! By the way nice and neat job
@zurriannetworks3 күн бұрын
I do sell enclosure boxes, kindly inbox
@OmtechSolar10 сағат бұрын
Pls are u in lagos i will to get this enclosure box for a project pls ur line..@@zurriannetworks
@EI.01Күн бұрын
Where is your location in Nigeria
@zurriannetworksКүн бұрын
Abuja
@kolobagale377923 сағат бұрын
I find your wires size smaller than required....
@gagzman111 сағат бұрын
My thoughts exactly
@zurriannetworks2 минут бұрын
Thanks for your observation. But they are all standard (Deye recommended) wire sizes. 10mm (8 AWG) for AC input and output, and 6mm TUV solar for the PV line. I appreciate your feedback