"You gotta make sure your testing it right steve" 😂
@porky77538 ай бұрын
185 gave that control board a "How you doing?"
@Android_Warrior8 ай бұрын
🤣🤣😂😂🌩🌩🌩🌩
@tomking18908 ай бұрын
Woud like to see a follow up on how much equipment is goofed up after all is fixed.
@Brad12372028 ай бұрын
Great diagnosis Steven! The facilities staff and I at the hospital are getting an education from every video! Keep up the great work! "Like you say, Every day is a school day."
@WeatherNut278 ай бұрын
Whoa! 185V?! Wonder what else burnt out. Power company will be getting a ton of complaints.
@theodorgiosan25708 ай бұрын
Used to work maintenance for a large store long ago and every week the voltage would go up to 175v for about a minute and wreck all the computer equipment. Power company was called about a dozen times and it was never fixed while I worked there. Never did figure out what caused it but I thought it was an intermittent short in the windings of the transformer that fed the store. Could never get them to replace the thing because it never did it while they were there.
@ntsecrets8 ай бұрын
Sounds like an open neutral for sure. Although usually that will vary with load. The other side of the line would be 60vac.
@butchbutch75218 ай бұрын
Should check if the neutral is shorting positive?
@robertblacksmith43558 ай бұрын
Great video SteveHope my mom's 44 yrs old Natural gas furnace keeps going just changed the original blower motor out last week!
@phased-out-24-738 ай бұрын
My sister's house lost the Neutral and her Vacuum Cleaner sounded like a Turbo Charger kicking in. Drove her crazy. She called me over and I was laughing my ass off.
@richardreynolds98858 ай бұрын
Gone woke Steve
@donhorn5488 ай бұрын
I love a good mystery
@hardies18 ай бұрын
Holy Smokes!! At that high of voltage I bet that there are other items around the house that have been knocked out as well.
@mtjr.30188 ай бұрын
Right On, thanks,Steve!
@kdmq7 ай бұрын
Could have also took your volt meter around the house and probed all the outlets. Bet ya you would have seen the same 185V. I work with electrical engineer designers at my job and we diagnose weird faults like this all the time.
@gthomas7858 ай бұрын
so your drop light and the condensate pump are getting 185v also? Did they survive?
@zackmax71848 ай бұрын
Sounds like the Neutral Wire from the Power Company is gone.
@jblyon28 ай бұрын
Maybe damage from a recent storm. A friend of mine had a similar issue a couple years ago and it burnt out pretty much everything that was turned on that wasn't run by a transformer rated for 100-240v.
@gocubsgo50558 ай бұрын
That plug on the side of the furnace is kweeuh.
@billnahorn39398 ай бұрын
That’s why you need your own neutral at the meter base , because when the power company loses their neutral you still have one and you don’t fry anything up. In our area power company not responsible. You need 2 ground rods 8’ apart very cheap way to keep a ground
@handyman93668 ай бұрын
You have no idea what you are saying! Why people like you find a need to comment and confuse others is beyond me. You even managed to get 9 likes lmao 😅 I pray you are not an electrician! 😮
@japmlp098 ай бұрын
Ground and neutral are differant.. differant potenetials..
@MichiganCustomCraftworksLLC8 ай бұрын
That's a hot 🔥 one there mama!
@tss2128 ай бұрын
I love your phone call. Made me laugh
@OfficerLarryNMSE8 ай бұрын
Do you know what's funny, Bobsdecline Lineman Blogger just posted a video on a Faulty Neutral Connection about a month ago. What an odd Coincidence, eh...
@tonym69208 ай бұрын
Hey Steve and Miss Molly! Workin’ again ya’ll. 👍👍
@nmccw32458 ай бұрын
“I know it’s a pile of York” 😂🤣😅
@dock_yard11498 ай бұрын
I love that quip.
@JavierGalvan-s2f8 ай бұрын
Good eye Steve on detecting that voltage! Another great video, remain safe and keep the videos coming ☝️ 👍 💥 👌 🫵
@jackl99228 ай бұрын
Good call Steve. I’ve run into issues before. A lot of houses here from the 80’s have shared neutral for branch circuits. My house does, but fortunately issues are always somewhere else. Lights going dim or bright on changing loads is a big clue. I know electric, but I watch you in order to help DIY other things. You’ve saved my ass on plumbing before. Thx!
@andyvitz8 ай бұрын
Nice right up to date
@fanofoldfans92388 ай бұрын
Wow 185 volts! Smoked the transformer for sure. A floating nuetral caused an unbalanced load between phases probably.
@dosgos8 ай бұрын
Check the next video to see if you are on track. . .
@japmlp098 ай бұрын
There isn't any phases.. its resideental.. single phase
@fanofoldfans92388 ай бұрын
Well L1 and L2 are split phase from the transformer and center tap neutral balances the load.@@japmlp09
@Sarah-ll8oi8 ай бұрын
How is everything so queen in this furnace???
@alfredwoodall6638 ай бұрын
Wow Steve that’s bananas 185
@jlindstrom38078 ай бұрын
I had a neutral issue at my house years ago, squirrel went into the pipe coming from the street and ate three quarters through the neutral wire, voltage would change every time I turned something on or off. Could have easily burned down the house.
@lancelawrence32598 ай бұрын
Nice work
@RetiredCanadian8 ай бұрын
Good reason why neutral, must be Grounded to water pipe. ...cheers
@robertsuelter41968 ай бұрын
Similar issue happened to me several years ago. Power company's line crossed and back fed through the neutral into the house. Fried everything electronic in 8 houses on our block. TVs, microwaves, computers, furnaces, stoves. Fridges and anything plugged in got cooked. Power company reimbursed for all damaged equipment.
@derekmc95808 ай бұрын
Definitely a neutral problem. I just had this problem at my mom’s house. Some of the receptacles started smoking is how she found out there was an issue. The voltage will look normal at the panel until a load is put on the system then you will see a huge difference between L1 and L2. She had like 200v difference between the two legs and it almost burnt the house down. It was a broken neutral at the step down transformer on the pole in the street.
@agostinodibella99398 ай бұрын
Wow, I wonder what other appliances could have been screwed up?
@ThomasWalker-m2y8 ай бұрын
Yep i think the Flux Capacitor took a ride at 185 volts.
@realSamAndrew8 ай бұрын
My Maserati does 185. I lost my license, now i don't drive... 🎶 🎶
@AlexanderWaylon8 ай бұрын
That’s a different one
@shupe19078 ай бұрын
so would the electric company technically be responsible for this if board is fried? (read what Steve wrote at the end)
@bobweiss86828 ай бұрын
Likely a broken neutral wire at the service head coming in from the street, Other things in the home probably burned out, as well.....
@dock_yard11498 ай бұрын
Maybe you'll get similar calls from the same neighborhood, since issue's on the Power Co supply side.
@shanebibby60068 ай бұрын
Thats not always the case could have a compromised panel or burnt neutral.
@WeatherNut278 ай бұрын
Good point
@dock_yard11498 ай бұрын
@@shanebibby6006 I wrote “maybe”. You replied “not always”. SMH
@shanebibby60068 ай бұрын
@@dock_yard1149 i was replying about the power company issue not the fact he could get more calls.
@shanebibby60068 ай бұрын
Shake your head all u want
@lonewolf7448 ай бұрын
Damm, That was a weird one. Not something you see everyday.
@AnotherAlfredHawthorneHi-kg4iv8 ай бұрын
This sounds like a job for a troubleman with a super beast service conductor tester.
@Evansautorepair8 ай бұрын
Got ta be netual
@sumitpatel97418 ай бұрын
Hey, Really Nice Video! I was wondering if I could Help You Edit Your Videos and Make Highly Engaging Shorts Out Of Them.
@rodneyskinner77418 ай бұрын
Hello Steve!
@gordonpotts7538 ай бұрын
Sounds like a failed line transformer from the power company.
@johnodonoghue6518 ай бұрын
Why not test the voltage at an outlet first?
@frankrizzo39158 ай бұрын
Hello Steve.
@wirenutjoe8 ай бұрын
Call the power company
@187rui8 ай бұрын
Check the tire pressure's
@butchbutch75218 ай бұрын
😂
@bills694620 күн бұрын
More accurately, the utility had an open neutral.
@Bob.W.8 ай бұрын
Hello
@urbanbshvac8 ай бұрын
Oh heck yeah there bud what a pile a York eh
@ethanchosdad-xh9ih9 күн бұрын
That was very queer when Steve said “weird” instead of “queer” 😂
@bobbywanger81238 ай бұрын
👍🔥
@28balancer8 ай бұрын
I wonder why your light didn't burn out when you plugged into receptacle. Should be same voltage, no? Did you check the receptacle as well?
@mrbigvanlife71308 ай бұрын
Stevie boy - how are you 😊
@sefaucon38398 ай бұрын
Tech tip Glue a magnet at the back of you tester, it makes a difference while working It holds itself !!!!
@1768ify8 ай бұрын
Those fieldpiece meters usually have one built in.
@flyer6178 ай бұрын
I've seen this before. You can usually tell it's a neutral issue if there is voltage between neutral and ground. There's going to be more than one problem, though; a bad neutral from the street and either a bad neutral-ground bond in the main panel or corroded/missing ground in the house, such as the wire to the cold water pipe from the street, or bad/missing ground rods. At this point the house is dangerous.
@timothyjerry11778 ай бұрын
That meter is queer The volts released the magic smoke
@mr.roberts38868 ай бұрын
This was one queer episode 😂
@mjg2638 ай бұрын
Ya lost a neutral to the service, seen it before.
@iamnoone.8 ай бұрын
Howdy Steve and Molly
@Skanzool8 ай бұрын
If the local utility is responsible for this, they should pay for the damage.
@overwatch26718 ай бұрын
Another pile of York steve
@worlddemize8 ай бұрын
Your neutral is queer it identifies as a hot leg
@RichardDenes-uj2lt8 ай бұрын
Sounds like a shit show to me Steve, I think you ought to give it an old. How you doing…… that’s what I think Steve
@GeorgeKennedy-u4r8 ай бұрын
Have her unplug the tv and it will come back to 120v. It's a shit show anyhow.