Congratulations on your new Syil. Sorry to see the coolant tank leaking problem you had. Cheers, Aaron.
@harley1999ft2 жыл бұрын
Congrats on the New Machine i like the Syi x7 i bought one Mines is the cast iron model with the 808d Siemens. Good luck with your Shop.
@Rimrock300 Жыл бұрын
Thanks for sharing. Yes, not only SYIL, generally everything can be okay during testing at the factory, but things can happen during transportation. Good idea to test with water first
@atnull24 күн бұрын
I'm not an electrician, just an armchair engineer but the reason why your lights dim when you power the phase converter on might be because they are supposed to be turned on without a load or transformer connected. American Rotary recommends connecting a load once the idler has gotten up to speed. You might need a disconnect between the converter and the transformer. This is from their manual: "Always make sure that the rotary phase converter starts before external load(s) are applied . This includes transformers that are connected downstream of the converter ."
@scpowered2 жыл бұрын
Think of the 3 wires of 3-phase as 3 points around a circle. Imagine each wire turning on-off in order of 1, 2, 3 clockwise around the circle. Now switch any two wires and the order will be counterclockwise around the circle.
@BalticBlades2 жыл бұрын
Oh man another one! Love to see all the things you have to do when you get a machine like this!
@tj.schwarz2 жыл бұрын
It's a lot of work, but so worth it!
@BalticBlades2 жыл бұрын
@@tj.schwarz it's super fun to come along in the process with these videos! Keep em coming!
@Hulign2 жыл бұрын
I ran the coolant washdown hose thru one of the bungs and inside the machine. I was just worried if it ever sprung a leak. If something bad can happen it will happen to me. I want to do something different with the air line too, maybe route it over the top and down. Don't want those dragging on the floor. You were smart to remove the entire plate. I should have been that smart. I am learning with mine but it will be forever before I am making fancy parts. Good luck with yours!
@testyourdesign2332 жыл бұрын
Looks so cool with both side by side. Must feel great to have 2 spindles for 2/3 the cost of industrial machines.
@tj.schwarz2 жыл бұрын
No doubt! I expect pretty big things out of the X7
@Moose-4zio Жыл бұрын
This is super helpful thanks!
@Blozoozozoz Жыл бұрын
For what it's worth, the high leg on the Delta impacts 240v and 120v applications. So, if one of the legs of the 3 phases were used to power 120v equipment, that would be an issue. But since you are going through a transformer, the transformer might actually change the wiring from delta to WYE.
@skeeterdirks399210 ай бұрын
Are you able to run the same tool holders from the Tormach in the Syil X7? Do they use the same pull stud?
@dmsentra Жыл бұрын
Switch any 2 of the 3 HOT WIRES to reverse the pump. Someone just starting to understand this will miss the fact you don't switch with the ground wire.
@harlech2 Жыл бұрын
I am looking more and more at a Syil. The Tormach just seems soooo Mickey Mouse.
@BecomingOffgrid2 жыл бұрын
My coolant tank leaks a tiny bit in the corners.
@22lambo2 жыл бұрын
Random question, what camera setup are you using? Looks compact and really nice video/audio quality
@tj.schwarz2 жыл бұрын
Thank you! It's the DJI Osmo handheld gimbal style camera. Love it!
@Randizzle8082 жыл бұрын
Can I ask what is the minimal amperage you would need for the 3 phase converter? I currently have 40amps in my garage..
@tj.schwarz2 жыл бұрын
I'm not an electrician, so I can't really speak with any confidence. All I can say is that the breaker needed for this particular phase converter is 50amp, but I know for a fact that the Syil is not going to use the full capacity of the 15hp converter. I have heard of people running a 10hp converter with this machine, which would be below 40 amps, but again I can't really guarantee anything.
@Randizzle8082 жыл бұрын
@@tj.schwarz awesome I appreciate the info..
@danohpsp2 жыл бұрын
The PEX should not be used long term. I breaks down with UV light and not rated for compressed air and may be affected by oil in the air. It will get hard and start cracking, which leads to blowouts. You spent good money on the machines, you should use copper it's not that expensive. Rapid Air is expensive, but that's a viable option also. The copper you can get locally at Home Depot also. You can get away with shark bites even, with the copper. Those feed wire gauges look a little small. Is there a green ground wire between the components? Flexible conduit is not a great choice for that application, conduit is much better. The voltages across each pair of the three wires should be identical. There are digital phase converters that can give you proper, similar voltages on all of the phases. 110V on the two legs is NOT going to give you full spindle and servo performance and may even cause control issues depending on which leg the control is running off. They make 110V single phase --> 380V 3 phase converters. Your missing wire strain reliefs on the idler motor and other cables. Tripping over that flexible conduit while live could be a big issue. You should add a disconnect switch box in addition to the circuit breaker. Your electrician friend did not give you the top advice I'm afraid you might need to consult the NEC standards. I'm concerned about your safety, especially with the 380V high voltages in some of the components. Best of luck.
@scotttravis9313 Жыл бұрын
I could be wrong but your wires coming into feed the machine look way too small. How many amps per leg?
@tj.schwarz Жыл бұрын
They are sized correctly according to rated amperage. I don't remember off the top of my head what they are. You probably already know, but 3 phase distributes the load and is able to use a fair bit smaller wire gauge than single phase.
@dejanvanevski43992 жыл бұрын
Which is better, Tormach or Syil?
@Rimrock300 Жыл бұрын
SYIL for sure
@matthewlee89172 жыл бұрын
Those are what we call “Non-Freedom Units” in my shop…..