How to Replace Module and Motor with PSC Motor and relay?

  Рет қаралды 41,227

Taddy Digest

Taddy Digest

Күн бұрын

Пікірлер: 156
@ajay6853
@ajay6853 Жыл бұрын
Wow, that unit is just about seen it's life. That environment takes a toll on the unit.
@joshuakuehn1402
@joshuakuehn1402 Жыл бұрын
Nice video. Good to see father and son
@soloch69
@soloch69 2 жыл бұрын
A big shout out to the best helper anyone could ever have your own son happy Father’s Day
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thanks for watching and being so kind 😊
@robertvigil1644
@robertvigil1644 2 жыл бұрын
You could not have put out this video at a better time. Our variable speed motor just went out and we cannot afford to replace it. This will definitely help us convert to the psc motor. Thanks!
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thank you so much Robert Really appreciate you watching Please share and hit the like button Also check out the video in the link in the description It's a good video for converting ECM type motors to people motors to PSC
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Click the video link below to watch how to convert a ECM type motor to PSC motor using Xswap product. kzbin.info/www/bejne/anncdZt-f5l-o9U Join this channel to get access to perks: kzbin.info/door/uMyjTVlkM4xZ5z_eSyoB1wjoin
@robertvigil1644
@robertvigil1644 2 жыл бұрын
Wired it up just like you said. Everything is working fine!! Thank you!!
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Awesome Robert I love to hear this man this makes me so happy So glad you got it working
@canhn8574
@canhn8574 Жыл бұрын
Thank you very much Ted. I like your videos.
@williamsanders3182
@williamsanders3182 Жыл бұрын
Great info and great presentation.
@TaddyDigest
@TaddyDigest Жыл бұрын
Thank you!
@Eddy63
@Eddy63 2 жыл бұрын
Good little replacement ... Your helper 's kind of rough on the old man 🤣😂😅 Thx for posting and good explanation on the relay ... Valuable info ...
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thanks Eddy He is a keeper though Love my boy Thank you for watching Have a blessed day
@waderosteet183
@waderosteet183 5 ай бұрын
Love your videos, please keep them coming. This is Wade in Lake Charles Louisiana. I have to rely on KZbin for my training
@marcushenneman4185
@marcushenneman4185 Жыл бұрын
My name is Marcus from Arizona, and I just added you along with others like Nor Cal, and many others.
@DanielCanizzo
@DanielCanizzo 5 ай бұрын
Great Training video ! Thank you.
@Trigger_32
@Trigger_32 Жыл бұрын
Have a friend in this very situation. Older York with a Gentec 2.3 just goes into washing machine mode. I had suggested swapping out to a PSC motor as a temp repair because he is looking to upgrade this fall. Gonna try replacing the thermistor first, this is plan B.
@joebyron9
@joebyron9 11 ай бұрын
This is the kid companies look for when they ask for 10 years experience straight outta highschool😂😂😂, way to go man head gonna be SUPERTECH
@cramos7287
@cramos7287 3 ай бұрын
😀😃😆
@roqueherrera2692
@roqueherrera2692 2 жыл бұрын
Nice very thermal instructions 👍🏽 now I can be confident on a retro fit
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thank you very much I really appreciate you taking the time to comment and tell me this makes me want to do more videos
@bensybency
@bensybency Жыл бұрын
Fantastic video.
@erikrezlman7900
@erikrezlman7900 Жыл бұрын
GOD Bless you Tad! What a mess and disastrous working area! I totally agree with the single speed motors. I don’t install variable due to repair expense. Single speeds, to me, are Reliable, cheaper and generally last longer.
@MrRalph438
@MrRalph438 Жыл бұрын
awesome content
@miguelalt8855
@miguelalt8855 Жыл бұрын
Another great video, thank you.
@TaddyDigest
@TaddyDigest Жыл бұрын
Glad you enjoyed it
@yaniergonzalez8197
@yaniergonzalez8197 4 ай бұрын
Amazing video save my day thank you
@jamessawyer6891
@jamessawyer6891 Жыл бұрын
Lol did this just the other day. Wait time for the mod is crazy.
@javierrangel3361
@javierrangel3361 4 ай бұрын
Awesome video man
@TaddyDigest
@TaddyDigest 4 ай бұрын
Glad you liked it
@dichuongchung8827
@dichuongchung8827 2 жыл бұрын
Thank you very much sir. I can fixed it from your lesson. I really appriciate it.
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Glad it helped!
@Alex-y2p5u
@Alex-y2p5u 4 ай бұрын
great video thank you
@TaddyDigest
@TaddyDigest 4 ай бұрын
Glad you enjoyed it
@Charles_S.
@Charles_S. 2 жыл бұрын
Very informative and defined! Thank you!!
@keovongvilaykeo4799
@keovongvilaykeo4799 8 ай бұрын
Thank you 🙏 good explanation 😊
@TaddyDigest
@TaddyDigest 8 ай бұрын
You're welcome 😊
@JayPatel-j9
@JayPatel-j9 6 ай бұрын
Hi .. Jay here from Calgary Alberta Canada ..
@soloch69
@soloch69 2 жыл бұрын
Great video bro love it keep them videos coming and stay safe out there
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Have a Blessed Day Brother
@USA-GreedyMenOfNoIntegrity
@USA-GreedyMenOfNoIntegrity 2 жыл бұрын
If our customer sets thermostat to emergency heat, normally W and G get energized. I always connect my blower relay to the G terminal, so that the blower energizes on all three...norm heat, emerg heat and cool modes. During em heat, the contactors will close, but on American Standard and Trane heat kits, the blower is not energized through the contactor. Unlike many other brands out there that are wired to bring on the blower through the heat sequencer.
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thank You for sharing this information Good Stuff You have experience 👍 Great Comment
@marvinsellers4457
@marvinsellers4457 2 жыл бұрын
Did a great job and it was cool your son was with you I take my grandson on just bout every one I go on Harold / Harold’s A/C Maintenance mobile al
@TaddyDigest
@TaddyDigest 2 жыл бұрын
It's awesome to be with family I'm glad you're taking your grandson Sometimes I just don't like working alone all the time
@pipi7731
@pipi7731 6 ай бұрын
Great Video but, I got a heating element to deal with. How do I rewire that heater element?
@jonathanbasiliere1327
@jonathanbasiliere1327 5 ай бұрын
your the man
@floridasaltlife
@floridasaltlife Жыл бұрын
Great job good video, tired of rip off hvac
@TaddyDigest
@TaddyDigest Жыл бұрын
Thanks 👍
@milo6373
@milo6373 Жыл бұрын
Nice 👍 work , more of these units , for sure to ride some over. ,☝️🙏💪✌️☯️
@TaddyDigest
@TaddyDigest Жыл бұрын
Right on!
@ktheat
@ktheat Жыл бұрын
I like to put rubber cushion's between the air hander and the blocks. The door panel is much easy to get off. But American Standard unit is hard to beat! But, I would use the green wire ( fan )on the thermostat on the relay. The way you wire it the indoor motor will not run on a heat pump when you put it on emergency heat. Am I missing something?
@paulmitchell9430
@paulmitchell9430 6 ай бұрын
I’m about to do this on a trane air handler in order to enable fan control from the tstat you said it would need a separate relay is that correct?
@TaddyDigest
@TaddyDigest 6 ай бұрын
yes
@tigerz4487
@tigerz4487 Жыл бұрын
don't understand how heating energizes the coil?
@williamrafferty6811
@williamrafferty6811 4 ай бұрын
This is a good time to clean the blower wheel. Oftentimes the dirt buildup on the vanes actually becomes convex, and destroys the air-moving capability of the wheel. I often had to use a screwdriver to scrape the vanes before hosing it off.
@andreagate542
@andreagate542 Жыл бұрын
thanks for a great video sir…… question, when you were running this unit in heating mode, are you saying that you get heat from the refrigeration cycle as well as the heat strips at the same time?
@klabkebash
@klabkebash 5 ай бұрын
Every HVAC Boss in America: "If the unit is in that bad of shape and it's over 15 years old, just replace the whole unit!!" =p
@nykid8849
@nykid8849 Жыл бұрын
hay when converting from ecm to psc , I guess all the specs has to much up to the current Ecm being replaced , any suggestion & which PSC motor s are widely used in field as converstion?
@johnnyriser8519
@johnnyriser8519 6 ай бұрын
Taddy, thanks for the video. It was well explained, and was very helpful. You initially said you were going to use two relays (2:03). You then changed, and said you would only use one relay (12:07). At the end of the video, you showed two relays were mounted (15:06). There was no explanation as to how the heating portion was wired using the second relay. I know you used another motor speed wire. Is the rest of the heater wiring using the relay the same, except we use the white wire? Thank you very much. Keep the videos coming!!
@TaddyDigest
@TaddyDigest 6 ай бұрын
I am pretty sure I used one relay for heat and cool using the Y call and one relay using the EM or emergency heat call cause this was a heat pump I will do an updated video
@johnnyriser8519
@johnnyriser8519 6 ай бұрын
@@TaddyDigest Thanks.
@tube8533
@tube8533 6 ай бұрын
Great!
@pkeeonline
@pkeeonline Жыл бұрын
Can txv installed out side the evaporator case?
@hvacandrefrigerationtechni1436
@hvacandrefrigerationtechni1436 2 жыл бұрын
For multiple speed ,may you need to have a thermostat controller with multiple fan speed options. I hope..grt video.
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Yes Absolutely 💯 Thank You for watching 👀 😀
@DoeyPP
@DoeyPP Жыл бұрын
All the programmable t stat will do the job plus you can have time delays in the stat for the electric heating.
@nilbertocohen4963
@nilbertocohen4963 2 жыл бұрын
Hi Taddy , if you would connect the g wire instead of the y wire , in this case would the ac run the same?
@TaddyDigest
@TaddyDigest 2 жыл бұрын
yes
@enriquehvac6004
@enriquehvac6004 Жыл бұрын
Could you do this on a variable speed motor on a furnace where the plug goes in at the furnace control board???
@TaddyDigest
@TaddyDigest Жыл бұрын
yes
@umerahmad3077
@umerahmad3077 Жыл бұрын
@Taddy, which psc motor and relays did you utilize to complete this project if I may ask?
@TaddyDigest
@TaddyDigest Жыл бұрын
I used a universal motor called economaster and the realy was a 9340 relay
@miguelalt8855
@miguelalt8855 Жыл бұрын
I am ignorant on the subject but I am trying to learn, I watched your other video “How to Swap ECM Motor with a PSC Motor”, I was wondering, you used a board quickswap X3 on that one and here you use the relays, either the board or relays will work? Thank you.
@DamienGermain-g8d
@DamienGermain-g8d 3 ай бұрын
Im a bit confused, didnt notice you wiring both relays, you wired 1 to close on cooling (y) and i assume the other on heating (w)? What about just using 1 relay with g to close the relay?
@TaddyDigest
@TaddyDigest 3 ай бұрын
good idea
@goodkao
@goodkao 8 ай бұрын
So, all you need is just a relay, no control board or any other thing, right? Do you have a video just like this for a gas furnace, too? Thank you so much for this video.
@TaddyDigest
@TaddyDigest 8 ай бұрын
You're welcome thank you so much for washing the video. I don't think I have a video for a furnace but I can do one.
@suryakantpatel7258
@suryakantpatel7258 Жыл бұрын
Hey Ted, great video. 1 question, how come you didn’t clean the blower wheel?
@TaddyDigest
@TaddyDigest Жыл бұрын
I did I just didn't show that part in the video I wanted the video to be about the motor and the relay
@ausseamore8386
@ausseamore8386 Жыл бұрын
@@TaddyDigest Thanks ! I was having a bit of OCD moment there
@anthonyelectric6045
@anthonyelectric6045 Жыл бұрын
Nice work Tad. But seriously that air handler was nasty 101. I wouldn’t breathe a single breath of air in the one. 👍
@TaddyDigest
@TaddyDigest Жыл бұрын
Tell me about it
@mrbubblesbooks
@mrbubblesbooks 11 ай бұрын
Would you start off as technician coming out of trade school or install so you can learn the units and parts better?
@TaddyDigest
@TaddyDigest 11 ай бұрын
Both
@stevem9629
@stevem9629 2 жыл бұрын
If the customer wanted the ability to turn on the indoor fan, how would you set that up? Your helper is the perfect size for a crawlspace!
@TaddyDigest
@TaddyDigest 2 жыл бұрын
I will do a video and show you how
@stevem9629
@stevem9629 2 жыл бұрын
Thanks for your response. I had a similar situation adding AC to an old (standing pilot) furnace. We used a 90 380 to control the condenser and heater. NO (2 and 4) when to the condenser and NC (5 and 6) was for the heat circuit. G was not used. If G was added, would need another 90 380? Would the wiring look like: The second relay, G and C to the 24v coil (1 and 3). On the switching side, NO to NO on the other relay. When the sub base fan switch is on, it will send 24V to the second relay and closes both NO switching relays and the indoor fan would turn on. Is that correct? I hope I explained it well.
@jamesz9139
@jamesz9139 Жыл бұрын
Tad - Great video...and now I'm hoping you can help. I have an obsolete Heil programmable speed control motor (230V, 1/2 hp, 1250 RPM/Var, 2.0amp) in my heat pump air handler. Worse, instead of a capacitor, it has an equally-obsolete control module (Google "AA20970" and you can see one...out of stock). The motor itself has a label that says, "If replacing with a permanent split capacitor motor, the motor voltage must match the unite line voltage and must not be connected to the speed control." So, my thought, get a PSC motor...but how do I interface it with the circuit controller (Texas Instruments 26FC-2) so it will work with my Honeywell Zone Controllers? Augh! Too many wires!! Of course, the tech that came to the house was at a loss; and recommended...you guessed it...full system replacement--for a mere $10,000 to $12,000....
@robertlowrey5485
@robertlowrey5485 2 жыл бұрын
Can that relay handle the heat strips? As far as amperage?
@TaddyDigest
@TaddyDigest 2 жыл бұрын
no relays are normally rated for around 20 amps and the contactor is rated for around 40 amps so it's a better suit
@theanimewatcher7172
@theanimewatcher7172 2 жыл бұрын
your awesome
@TaddyDigest
@TaddyDigest 2 жыл бұрын
thank you 😊
@marcusdarnell3348
@marcusdarnell3348 2 жыл бұрын
Great video man. Does that fan operate in emergency heat mode also? I assume to you disabled that mode since you mention it.Oh and u have the best helper in the world take care!
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thanks Marcus
@jerrywilhelm2634
@jerrywilhelm2634 Жыл бұрын
If you don’t want your elements not to fail prematurely you need some sort of off delay
@weaverp1
@weaverp1 Жыл бұрын
The heat strips will trip the breaker if there isn't some kind of sequencer. Shouldn't hurt the strips unduly though.
@ajay6853
@ajay6853 Жыл бұрын
The unit already had sequencing relays in it. This is simply to activate the fan motor on high speed.
@randomvideos9413
@randomvideos9413 Жыл бұрын
If the one and only fan speed is used for a call on Y and nothing on W how do the heat strips get airflow in emergency heat?
@Bobby8451
@Bobby8451 3 ай бұрын
I believe I'd go ahead and do a complete brand new install and replace that 1920's system. Lol
@TaddyDigest
@TaddyDigest 3 ай бұрын
hahaha yes sir
@sonnguyen-ve7gn
@sonnguyen-ve7gn 2 жыл бұрын
Hey Teddy How can to become your member? And how much ?
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Join this channel to get access to perks: kzbin.info/door/uMyjTVlkM4xZ5z_eSyoB1wjoin Wanna Learn more about hvac? Check out my hvac tips for technicians playist. kzbin.info/aero/PLVjetZt5xgenmO76adHwb2ctyeBIFKUus
@billysmith9126
@billysmith9126 Жыл бұрын
When swapping out an ECM motor and replacing it with a PSC motor, how do you know which PSC will work properly? There's so many options! Does the horsepower, RPM's, Htz, amps ECT have to match?!?!?!
@newstart49
@newstart49 Жыл бұрын
Without the G wire connected for blower, there will be no emergency heat.
@williamrafferty6811
@williamrafferty6811 4 ай бұрын
Don’t use a chisel on the end of the shaft. You’ll deform it and never get it out. If you don’t have a squirrel-cage shaft puller, either keep sanding and soaking in penetrating oil(Rust Buster works great), or use a pin punch close to the size of the shaft.
@DoeyPP
@DoeyPP Жыл бұрын
Hook your relay to the green wire for the fan the t stat will control the fan , not the cool wire .
@TaddyDigest
@TaddyDigest Жыл бұрын
Thanks for the tip
@justspeedy3650
@justspeedy3650 9 ай бұрын
Connect Y as 24v and not use G?
@TaddyDigest
@TaddyDigest 9 ай бұрын
i think this was a heat pump so it would energize cooling and or heating mode with the Y and that would energize the blower.
@UselessKnowledge904
@UselessKnowledge904 11 ай бұрын
So the black wire from the relay runs to the capacitor and then from the capacitor to the blower motor?
@donplumber6141
@donplumber6141 2 жыл бұрын
Like what you showed except you didn't clean squeal cage or housing
@TaddyDigest
@TaddyDigest 2 жыл бұрын
I didn't show that part 😕 thanks for watching 👀 😀
@isaiahodum7071
@isaiahodum7071 2 жыл бұрын
Hey Tad, appreciate all your videos! Question: I'm currently trying to do this to my unit and I was wondering why did you use Y instead of G?
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thank You Isaish 😊 I used Y so that when the cooling was energized the blower would too.
@isaiahodum7071
@isaiahodum7071 2 жыл бұрын
@@TaddyDigest Is there anyway I could get on the phone with you or video chat and pay you for your time? I know that's an odd request, but I haven't had A/C for 2 weeks and I'm ready to be done with it.
@TaddyDigest
@TaddyDigest 2 жыл бұрын
I can definitely help you 🙂 Click the join button become a member I will give you my email and then my phone number
@isaiahodum7071
@isaiahodum7071 2 жыл бұрын
@@TaddyDigest 👍I sent you an email.
@ConnorMill3r17
@ConnorMill3r17 2 жыл бұрын
@@TaddyDigest love your vids Tad, I watch them all the time. Ty for all that you do. I may have missed something but if they put stat on emergency heat, is the fan going to run?
@cliffm7427
@cliffm7427 2 жыл бұрын
That unit looks Rough, but at least it buys them time to save for a replacement
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Yeah it was super rough Still haven't replaced it yet But I'm sure before too long it will be replaced
@markchapman4197
@markchapman4197 11 ай бұрын
You didn't clean that blower??? Wow!!
@TaddyDigest
@TaddyDigest 11 ай бұрын
that's in another video 📹 I did
@SoCaL884
@SoCaL884 Жыл бұрын
I normally wash the blower wheel if I don’t replace it
@DoeyPP
@DoeyPP Жыл бұрын
Should of washed the evap and the bower wheel out when you had the blower out.
@TaddyDigest
@TaddyDigest Жыл бұрын
I did I just didn't put that part on video
@vicg1973vg
@vicg1973vg Жыл бұрын
Good video but you said 2 relays a 1st then u said 1 relay then later on video it shows 2 relays it just confused to what you done to use 2 relays on the end I should of showed the pressures after u clean coil cause not all the time pressures go down when u clean coils on the low side!!but thank you
@TaddyDigest
@TaddyDigest Жыл бұрын
thanks I will check the video out and see what I was thinking 🤔
@dominicformando3931
@dominicformando3931 Ай бұрын
man that thang is filthy lol
@stillpointx2623
@stillpointx2623 Жыл бұрын
I hate crawl spaces...we took ours out and we had black window spiders...they love hvac's
@GB-ue6wr
@GB-ue6wr Жыл бұрын
Wow that unit was/is in bad shape.. someone needs to put a filter in that unit..
@GB-ue6wr
@GB-ue6wr Жыл бұрын
Love the videos man, keep up the great work.
@EzPredicts
@EzPredicts Жыл бұрын
R-22….
@TaddyDigest
@TaddyDigest Жыл бұрын
yup
@JustinKais
@JustinKais 3 ай бұрын
The last decent AC system. After that it went to shit and now they break after a few years.
@eastcoast186
@eastcoast186 2 жыл бұрын
Nice voice over of 1st video we’re you wire the relay wrong to power two speeds at one time when heat pump run and auxiliary stages in by by motor 2nd voice over of 1st video close but the fan won’t run when thermostat is set to emergency heat 3rd time is a charm go luck
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thank you for all your help I appreciate your comment 🙂 Have a Blessed Day Brother 🙌
@TaddyDigest
@TaddyDigest 2 жыл бұрын
Thinking about you this morning Thank you again for making me aware of my mistake in the first video. You are awesome
@og6057
@og6057 Ай бұрын
Why would you do a video of a half * ss job? This video had potential but you only completed partial wiring control functionality. So, it's really almost worthless as an instructional video.
@TaddyDigest
@TaddyDigest Ай бұрын
thanks for watching
@DoeyPP
@DoeyPP Жыл бұрын
Clean the unit dude that is nasty
@TaddyDigest
@TaddyDigest Жыл бұрын
I did I just didn't put that part on the video
@PBS-nm1uu
@PBS-nm1uu Жыл бұрын
confusing
@TaddyDigest
@TaddyDigest Жыл бұрын
well crap
@donaldpainter956
@donaldpainter956 Жыл бұрын
Not much professional work going on here
@TaddyDigest
@TaddyDigest Жыл бұрын
Just average Joe stuff going on here
@donaldpainter956
@donaldpainter956 Жыл бұрын
@@TaddyDigest I'm not saying anything about your knowledge it's just you are snatching wires and just like tearing that board out then you didn't clean anything at all even though the unit will be replaced just the professional sense would have cleaned the blower wheel and housing and cleaned all that dirt and shit out of the blower compartment if a new tech watches this video they are going to see how to half ass the job and think that's ok to do on top of that you are showing viewers this is your work your reputation you have knowledge just some poor work ethics
@TaddyDigest
@TaddyDigest Жыл бұрын
Yeah you're right I did not show the part of the video where I cleaned the indoor coil and the blower wheel and I would have showed that now knowing what I know I'm glad that you know what professional work looks like and I'm glad you said this You are definitely a professional my friend
@joebyron9
@joebyron9 8 ай бұрын
nasty ass unit, should have replaced it
@DrStephenpearcy
@DrStephenpearcy 3 ай бұрын
What energizes the blower when the thermostat is set for emergency heat? 🤔
@TaddyDigest
@TaddyDigest 3 ай бұрын
Call for emergency heat from the thermostat. You could have another relay that energizes the fan
@franciscovelez6167
@franciscovelez6167 3 ай бұрын
you missing the other blower part ,the common wire
Replace Your Outdoor ECM Motor with a PSC Motor in NO TIME!
16:55
Taddy Digest
Рет қаралды 15 М.
ECM TO PSC BLOWER MOTOR CONVERSION
12:17
D2D NY Real World HVAC Simplified
Рет қаралды 8 М.
요즘유행 찍는법
0:34
오마이비키 OMV
Рет қаралды 12 МЛН
УЛИЧНЫЕ МУЗЫКАНТЫ В СОЧИ 🤘🏻
0:33
РОК ЗАВОД
Рет қаралды 7 МЛН
PSC Motor vs Constant Torque Motor vs Variable Speed Motor | Comparison Video
13:46
Fox Family Heating and Air Conditioning
Рет қаралды 102 М.
How a Relay Works with the 90-340
11:02
HVAC School
Рет қаралды 89 М.
Mastering Gas Heat in 10 Minutes
32:32
Taddy Digest
Рет қаралды 33 М.
ECM to PSC Blower Motor Conversion (Detailed)
14:34
Zack’s in the Shop
Рет қаралды 164 М.
converting an ecm motor to a psc motor and installing a relay from start to finish
10:09
Mcdonald mechanical services
Рет қаралды 7 М.
HVAC Silver Soldering vs Brazing vs Brazing While Flowing Nitrogen!
18:42
AC Service Tech LLC
Рет қаралды 131 М.
Replacing an X-13 ECM motor with a PSC (capacitor) motor.
25:29
ECM Motor Troubleshooting
10:26
Enertech University
Рет қаралды 118 М.
Furnace ECM Motor Repair
28:09
John Salt
Рет қаралды 200 М.
요즘유행 찍는법
0:34
오마이비키 OMV
Рет қаралды 12 МЛН