Why is the Heat Pump Freezing up?

  Рет қаралды 13,488

Taddy Digest

Taddy Digest

Күн бұрын

Пікірлер: 62
@roberts1159
@roberts1159 Жыл бұрын
Great video. Short and to the point.
@paulbryant68
@paulbryant68 Жыл бұрын
my girl tells me this all the time!🥴
@TaddyDigest
@TaddyDigest Жыл бұрын
lol 😆 😂
@TaddyDigest
@TaddyDigest Жыл бұрын
thank you 😊
@Eddy63
@Eddy63 Жыл бұрын
Good info Tad ... Thx
@paulbryant68
@paulbryant68 Жыл бұрын
my maaan!!!! thx again! i learned this test from you months ago so i was answering your questions as you asked them…and yes gottem all right! ha
@markwest5161
@markwest5161 Жыл бұрын
Also if you want to make defrost sensor get cold faster disconnect outdoor fan.
@tedhicks5431
@tedhicks5431 Жыл бұрын
Thats what I do get that defrost t stat cold
@DavidJones-qg5yu
@DavidJones-qg5yu Жыл бұрын
Great video! Tad💪🏽
@TaddyDigest
@TaddyDigest Жыл бұрын
Glad you liked it!!
@TomLawson05
@TomLawson05 Жыл бұрын
Great job tad always like your videos
@pauldiesel4582
@pauldiesel4582 Жыл бұрын
Thanks! Great concise video!
@TaddyDigest
@TaddyDigest Жыл бұрын
Glad you enjoyed it!
@MrAdamd83
@MrAdamd83 Жыл бұрын
In the defrost I didn’t notice the outdoor fan shut off if in question jump the defrost sensor and hit the test pins it should stay in defrost until the jumper is removed
@markwest5161
@markwest5161 Жыл бұрын
Remember suction pressure to temperature.temperture should be 15-30 degrees below outdoor ambient
@justwork_hvac
@justwork_hvac Жыл бұрын
Awesome video, brother. Very educational 🤟💯🌎
@TaddyDigest
@TaddyDigest Жыл бұрын
Much appreciated
@MichaelSmith-pg6gi
@MichaelSmith-pg6gi Жыл бұрын
Hey quick question guys... if the heat strip are on will that affect my high side / subcool readings on my guages? How would you turn them off just untwist or loose the white wire on the defrost board?
@theswordofkings7549
@theswordofkings7549 Жыл бұрын
Nice, and to the point. And if it's an older unit with corrosion on the indoor coil, the slight vibrations caused a light leak....Or someone went in there with a knife or screwdriver to try to knock off some grunge 😂. Thanks👍
@vetdadcubby4722
@vetdadcubby4722 Ай бұрын
Keep banging’ em out! 😎
@sparkyobrian6417
@sparkyobrian6417 Жыл бұрын
they’ve been chasing a leak on my minisplit for over a year now, sadly the two different companies have resorted to the parts cannon method. they said they now want to change ALL the lines to the 5 zones, $6000 in labor was the cheapest quote, only the parts are under warranty. the system looses $870 in 410a every 3 weeks. Im getting the feeling the companies in my location know less about hvac than my postal carrier
@TaddyDigest
@TaddyDigest Жыл бұрын
that is a crazy price if it only last 3 weeks its probably in the indoor coil
@Fastandpro
@Fastandpro Жыл бұрын
That loss rate should be easy to find and unlikely to be in the lines unless they are rubbing somewhere and worn though. Are you sure it's two different companies or two different adverts?
@akbychoice
@akbychoice Ай бұрын
If seen things like lines get punctured by a screw or nail because of how or where the lines were run.
@parkerpasternack206
@parkerpasternack206 Жыл бұрын
So where was the leak?
@TaddyDigest
@TaddyDigest Жыл бұрын
I found oil residue in the evaporator coil pan I'm pretty sure the indoor coil is the problem
@williamserver4332
@williamserver4332 Жыл бұрын
When testing subcooling on a heatpump should you check liquid line temperature at the outdoor unit or inside at airhandler? I wonder if the temp would drop much. Thanks for the videos
@stevenmorales5181
@stevenmorales5181 Жыл бұрын
Inside, on this method! You would focus more on the approach method, return dry bulb minus liquid line temp. Liquid line temp should always be higher than return air.
@frankevans588
@frankevans588 Жыл бұрын
Good stuff brother
@TaddyDigest
@TaddyDigest Жыл бұрын
Right on
@davidhorne2326
@davidhorne2326 Жыл бұрын
What delta t do you like to see on straight heat pump, sat/rat?
@ChillMastersAC
@ChillMastersAC Жыл бұрын
Hey man! I got ya! Temperature difference usually depends on the amount of humidity in the home. (Wet-Bulb). With the Wet-bulb temperature and the dry bulb temperature you can then look at a chart and determine what the proper Delta T should be. In heating mode though it is usually 25-35 or more. For cooling here in Arizona we like to see about 18-22.
@Al-sp7jx
@Al-sp7jx Жыл бұрын
Thank you great video
@dnell6854
@dnell6854 Жыл бұрын
Great video!!
@TaddyDigest
@TaddyDigest Жыл бұрын
Thanks!
@dnell6854
@dnell6854 Жыл бұрын
@@TaddyDigest which freon is that?Thanks
@vinceparks3798
@vinceparks3798 Жыл бұрын
What refrigerant did you add to the system?
@MetroMindsApperal
@MetroMindsApperal Жыл бұрын
That’s what I was thinking to.Never seen a blue R-22 jug.
@IamHimathy420
@IamHimathy420 Жыл бұрын
That's good 'ol 422B baby
@StevenWard-s3d
@StevenWard-s3d Жыл бұрын
That noise would drive me crazy.
@vieuxacadian9455
@vieuxacadian9455 Жыл бұрын
1980s Ernest P. Worell said " Heat pump smeet pump " .
@brunoshvac2578
@brunoshvac2578 Жыл бұрын
When you forced defrost shouldn’t the ODF of stoped as well. Either defrost relay is stuck closed or it’s been wired around the defrost control. Fan should not be running in DF.
@TaddyDigest
@TaddyDigest Жыл бұрын
I did not short the test pins long enough. I also did not have the defrost thermostat closed
@abdullah_q8171
@abdullah_q8171 Жыл бұрын
Its time to change R22 unit.
@markwest5161
@markwest5161 Жыл бұрын
System is 15 years old time fir new. Never try to make pressure meet heating chart it is only a guide line. Only way to properly change is in cool mode,and verify indoor metering device. Just because it says txv outside doesn't mean it is inside. Best rule of thumb fir r22 in heat mode is low side pressure should be within 15 of outdoor temp.(is 40 degrees 40 psi + or -) Only for checking but etc d well.
@stevenmorales5181
@stevenmorales5181 Жыл бұрын
And Third! If your R terminal, “24v” gets disconnected or if there is a safety switch cutting off the R terminal for outside, the heat pump won’t do the defrost cycle.
@ChillMastersAC
@ChillMastersAC Жыл бұрын
Hey man nice video I love the content I just have a couple tips! When testing SH in heating mode that suction line is no longer the suction line so that temperature your getting is the Discharge line temp. To get true Superheat in heating mode I usually open the top and clamp the big pipe on the inlet of the outdoor unit. Time consuming but worth it to get True SH so you are not overcharging! Love the content keep it up
@TaddyDigest
@TaddyDigest Жыл бұрын
Good tip Yes sir thank you for watching I really appreciate you.
@StevenWard-s3d
@StevenWard-s3d Жыл бұрын
Nice
@pascualangulo1
@pascualangulo1 Жыл бұрын
Super brot
@misfit67
@misfit67 Жыл бұрын
I would replace that old Fan Motor on that old POS🤣
@DavidKane-j5u
@DavidKane-j5u 7 ай бұрын
look for oil first
@Al-sp7jx
@Al-sp7jx Жыл бұрын
Got a cell # I can pick your brain?
@TaddyDigest
@TaddyDigest Жыл бұрын
Yeah level four membership will get you phone number access
HEAT PUMP FROZEN UP LIKE A ICE MACHINE I MISSED  UP & TOASTED THE FUSE
24:43
Ozoda - Alamlar (Official Video 2023)
6:22
Ozoda Official
Рет қаралды 10 МЛН
"Идеальное" преступление
0:39
Кик Брейнс
Рет қаралды 1,4 МЛН
SLIDE #shortssprintbrasil
0:31
Natan por Aí
Рет қаралды 49 МЛН
Heat Pump Freezing Up in Apartment Building
23:19
Taddy Digest
Рет қаралды 12 М.
Gas Valve Troubleshooting Secrets Beginner HVAC Technicians Need
16:58
What should I do if my heat pump freezes?
8:14
Taddy Digest
Рет қаралды 89 М.
Rheem Heat Pump Freezing in the Heat Mode
34:22
HVAC GUY
Рет қаралды 19 М.
Major Advances with Heat Pumps in the Extreme Cold
14:43
Undecided with Matt Ferrell
Рет қаралды 682 М.
Heat Pump Heating Reminders w/ Bert
31:07
HVAC School
Рет қаралды 53 М.
What's inside a Heat Pump?
23:47
John Cantor
Рет қаралды 7 М.
How to initiate Forced Defrost and replace defrost thermostat?
10:19