This is one of the best fuse board change videos I've seen. Very neat job. Well done. 👍
@AdamDunlopElectrical11 ай бұрын
Thanks 👍
@andrewpowellnz10 ай бұрын
Better than Nicks work .😄
@thereal100610 ай бұрын
Fair play you are progressing quite well we all get better with time your on the right track keep up thr good work
@AdamDunlopElectrical10 ай бұрын
Thanks
@daviddawson909910 ай бұрын
Good work Adam glad to see things going well
@AdamDunlopElectrical10 ай бұрын
Cheers
@JensenPGATourDriven10 ай бұрын
Great content, Adam, specially teaching apprentice Ted , it’s not easy finding a qualified electrician willing to take you on , or help with work experience. Good on you ⚡️👊
@AdamDunlopElectrical10 ай бұрын
Thanks 👍
@g.williamswilliams84426 ай бұрын
Most knowledgeable apprentice ive ever seen... Yoo Good job 😊
@AdamDunlopElectrical6 ай бұрын
Thanks a ton
@jonathandugan741811 ай бұрын
The good old crabtree c50s, luckily I've not seen one in ages, good job done and another great video
@AdamDunlopElectrical11 ай бұрын
Cheers
@Ragnar850411 ай бұрын
They look similar in style to the FPE ones that occasionally pop up in Europe.
@anthonybragg11 ай бұрын
Another great one Adam, you have to watch those Crabtree C50 consumer units with all the exposed live parts. You could have fitted an earth block and used it as the MET. No Maryland cookies !!!!!!!!
@AdamDunlopElectrical10 ай бұрын
Cheers and nope I ate them all 😎
@metrotechguru586311 ай бұрын
Well done Adam. Nice camera work by Ted.
@AdamDunlopElectrical11 ай бұрын
Many thanks!
@metrotechguru586311 ай бұрын
@@AdamDunlopElectrical You're very welcome.
@ashleyproverbs365311 ай бұрын
Absolute Class work!..well done pal.
@AdamDunlopElectrical11 ай бұрын
Thank you! Cheers!
@sergiofernandez372511 ай бұрын
Nice work Adam. Great to see you giving work experience to Ben.
@AdamDunlopElectrical10 ай бұрын
Much appreciated!
@richrowley835511 ай бұрын
Nice one Adam. Neat board again.
@AdamDunlopElectrical11 ай бұрын
Glad you like it!
@acelectricalsecurity10 ай бұрын
Immersion heaters used to be wired on 1.5mm cable, which is what the unknown circuit could have been. Also your 6mm cable could be ok on a 45amp breaker as 6mm is good for 46amps in ideal conditions.
@AdamDunlopElectrical10 ай бұрын
In ideal conditions however I knew it wasn’t run clipped direct
@anthonybonnici882511 ай бұрын
Well done nice job Adam. Say goodluck to your apprentice
@AdamDunlopElectrical11 ай бұрын
Thanks 👍
@joeypriestman678310 ай бұрын
It’s so weird not seeing you and Nick both together. Probably easier for your mum to meet Nick but it’s still odd.
@SarahJane14811 ай бұрын
Well done Adem great video
@AdamDunlopElectrical11 ай бұрын
Thanks 👍
@ForTheBirbs10 ай бұрын
And the apprentice becomes the master... Little Ad all grown up! Lol. Well done
@AdamDunlopElectrical10 ай бұрын
Cheers
@ianchapman958510 ай бұрын
A interesting video, explaining things well
@AdamDunlopElectrical10 ай бұрын
Glad you liked it
@kalel81011 ай бұрын
Bang on work fella 👏 , stickers looks really nice. Just a FYI tho you dont need the mix colours anymore. Think it was last amendment that took it out. really need to get on with trying them boards and does that company do the fuse Fan Isolaters? Thanks
@AdamDunlopElectrical10 ай бұрын
Cheers dude I didn’t realise the stickers changed and yea verso fo the nice fuse spurs and fan iso
@Mini-Explorer10 ай бұрын
The only board label recommended now is a 6 monthly RCD test sticker.
@Gaunty21310 ай бұрын
Question was the bonding/parallel paths removed when carrying out Ze i can also hear GSH screaming it’s not a ring main do you work for the DNO
@tonywatson141210 ай бұрын
Adam I hear this so often on sparks you tube. channels...how do you forget stuff that should always be in the van...examples include/ ceiling roses .. switches..surface boxes...tails gland...10 and 16 mm. earth...The list goes on....
@AdamDunlopElectrical10 ай бұрын
I stock everything you’ve spoke about apart from I’d used all my glands we are all human and when using loads hard to keep stuff stocked
@chrishughes652010 ай бұрын
I eicr normally, unless the original wiring is perfect . I normally give 5 years on existing wiring, 10 on a new install. You can give a 5 year EIC too.
@AdamDunlopElectrical10 ай бұрын
Cheers
@09weenic10 ай бұрын
Liked and subscribed
@mustang629611 ай бұрын
you good job as nick would say he teached you well adam keep the vids coming
@AndyK.111 ай бұрын
Taught him to run when he finds a borrowed neutral 😂
@AdamDunlopElectrical10 ай бұрын
Cheers appreciate it
@AdamDunlopElectrical10 ай бұрын
Facts
@Sparkyjedi10 ай бұрын
You’ve done well there mate squeezing that board into that meter box 👍 just not a great fan of the Tncs/Pme connection being used as a MET , a nice earth bar or a Henley block 😀
@AdamDunlopElectrical10 ай бұрын
Thanks 👍
@benhall720910 ай бұрын
hi Adam what software do you use for your certs ?
@AdamDunlopElectrical10 ай бұрын
Easy cert
@charliewinter65510 ай бұрын
just a heads up as i got picked up on it with my NICEIC inspection , you shouldn't liven up a circuit if its unknown , if something were to happen you would be the one paying the price!
@advann111 ай бұрын
like the stickers professional god bbless you and nick
@AdamDunlopElectrical10 ай бұрын
Cheers
@danielrowe211911 ай бұрын
Neat job. Have you considered putting the blanks in between the RCBOs to minimise any heat build up? Maybe worth considering on your next consumer unit change?
@AdamDunlopElectrical11 ай бұрын
I have done that before
@dg290810 ай бұрын
When you do a board change, signing your EIC means taking responsibility for the safety all the wiring that's connected to it, just like issuing a satisfactory EICR. So an EIC is fine - surely you'll have done the same amount of (or more!) inspection and testing to issue the EIC. You may have to explain this to letting agents though. I had one client who decided to rent out two years after I changed their board, and that meant that they didn't need an EICR doing before the tenant moved in. It's not specified in the big brown book, I wish I could remember where it comes from; in my head I know that unless the condition of the installation dictates more frequently, an owner occupied house will generally be 10y to retest, and a rental property 5y. Certainly the government's 'private rental sector' regulations mandate the latter
@AdamDunlopElectrical10 ай бұрын
Cheers for the info much appreciated
@jamesclark309010 ай бұрын
You write on your EIC form what you have done, your EIC only covers this, that is why it is important to fill the form accurately.
@michaelsimpson660310 ай бұрын
what exactly did you do with the shared neutral ?
@AdamDunlopElectrical10 ай бұрын
Nothing
@hohohobadmofo873710 ай бұрын
Can you issue an EIC?
@peterconnolly460811 ай бұрын
Consumer unit ?
@AdamDunlopElectrical10 ай бұрын
Another word for fuseboard
@Alex-wz4op11 ай бұрын
Yo Adz, im really struggling to gather evidence towards my NVQ, my boss wont let me get any evidence on site as he wants me working full time. any suggestions or tips or tricks for gathering evidence and writing it up afterwards?
@nodwaa922711 ай бұрын
yeah. look for a new boss. hes a tosser if he wont let you get evidence.
@AdamDunlopElectrical11 ай бұрын
I used to take photos then write it up at home 👍🏻
@MBSparks00111 ай бұрын
I would have another chat with your boss and explain how important it is that you can take your photos for your NVQ if he’s not willing to help you out a little then might be time to find somebody else that wants to help you develop
@Alex-wz4op11 ай бұрын
Appreciate the advice, trouble is there are next to 0 opportunities in Devon, just feel stuck, my college wont help, my employer wont help. I'm honestly mostly self taught at this point@@MBSparks001. was thinking maybe self employed as a mate might be my only option but im told the NVQ Level 3 is a lot more thorough but at least it will be under my own control. i don't know what to do.
@Ant9898610 ай бұрын
I remember when you had bum fluff and were crap :D you turned out alright!
@AdamDunlopElectrical10 ай бұрын
Ahah cheers
@terrybutler123111 ай бұрын
It was a leasehold property, you shouldn’t even be drilling holes through walls without permission from the freeholder, which appears in this case to be the council. So always proceed with caution.
@Ragnar850411 ай бұрын
I thought it was a freehold flat that the freeholder wants to rent out, perhaps ex-council?
@cjmillsnun10 ай бұрын
@@Ragnar8504 Flats are nearly always leasehold.
@AndyK.110 ай бұрын
Didn’t realise you just needed to put #viral in the description to get more views. Good test 😅
@AdamDunlopElectrical10 ай бұрын
😅
@AdamDunlopElectrical10 ай бұрын
Thumbnail is the biggie
@AdamDunlopElectrical10 ай бұрын
Title is the Tupac
@jacklaksamana11 ай бұрын
Wow, it's 2024 and consumers like this are still being used? legend stuff 😅
@AdamDunlopElectrical10 ай бұрын
Yep I still go out to 3036 boards most weeks
@kevinwright19511 ай бұрын
I bet the new board won’t last as long as the good old Crabtree c50 board.
@AdamDunlopElectrical11 ай бұрын
Mhh I reckon it would but would be Intresting to take a look in 40 years
@kevinwright19511 ай бұрын
Had several new circuit breakers/rccb failing in less than a week some on day 1. Never had a c50 fail so quick the newer ones marked in yellow introduced after the 15th edition regs think they had a higher fault current capacity. The board you fitted gives a lot more protection good job. Retired now but fitted loads of Crabtree c50 boards back in the 70s.@@AdamDunlopElectrical
@acelectricalsecurity10 ай бұрын
You are right there or the old wylex wooden backed ones that I still come across
@sparkiegaz361311 ай бұрын
👍👍👍👍👍👍👍
@AdamDunlopElectrical11 ай бұрын
Cheers
@365aqualife811 ай бұрын
Good job kiddo
@AdamDunlopElectrical10 ай бұрын
Thanks 😅
@karlparhad780510 ай бұрын
Ring final circuit
@callumwhitelaw458110 ай бұрын
Eh… are u not still an apprentice 😅. Should it not be a journeyman teaching the apprentice not a fellow apprentice or am I missing something here? how can you have your own company (name of your company on d.b stickers)if you are still an apprentice or have you qualified now? I’m confused 😅
@AdamDunlopElectrical10 ай бұрын
I’m qualified ahah
@thetruth669311 ай бұрын
Those stickers and logo look the bollocks
@AdamDunlopElectrical11 ай бұрын
Cheers 👌🏻
@hoonsurdaddy848211 ай бұрын
Apprentice here please correct me if I'm wrong but 1.49???? Are you sure??? If it's 1.5 cpc it should be around 1.07 and if 1mm CPC 1.6. I'd be putting that as a F1. Only thing I can think of if it's 1mm and you are getting a parallel path? Also bud make sure you put back the main earth before getting you PFC. You want to ensure all parallel paths are in situ to prove the highest amonut of fault current that can flow.
@johnwarwick410510 ай бұрын
You “young ones” never use some stripped cable outer as a grommet strip 😳
@AdamDunlopElectrical10 ай бұрын
Ahah
@awsometomable10 ай бұрын
why did you say nice easy fix like you didn't just put them all on the same RCBO, you haven't fixed it you've changed your install to accommodate a fault
@awsometomable10 ай бұрын
Also Ze with parallel earth paths connected, directly against GN3