The changes to igem g 11 and 13 that all gas engineers and trainees need to know.

  Рет қаралды 17,051

Tomkat Gas Training

Tomkat Gas Training

Күн бұрын

Пікірлер: 64
@keithprentice2100
@keithprentice2100 2 жыл бұрын
Thanks for putting out these videos..it’s a great help for the self employed engineers to keep up to date.
@rayc1503
@rayc1503 2 жыл бұрын
Thanks for keeping us abreast of the current and forthcoming standards Dez. 👍
@jonathanwilliams8309
@jonathanwilliams8309 2 жыл бұрын
Thank you for all your marvellous videos. They are a great help, in so many ways.
@themadhatter4761
@themadhatter4761 2 жыл бұрын
Great video, thanks for keeping us all up to date. Greatly appreciated
@russellbird2246
@russellbird2246 2 жыл бұрын
Topman keep up the good work of educating, refreshing and refunding all the gas sniffers and knob touches out there 👍🏻
@johnward5006
@johnward5006 2 жыл бұрын
I have all IGEM 11/13 TB's up to date. How many installers bother to do the same? So your post is so important, and that's why you go to the lengths you do to update and inform installers. I would say that ultimately gas meter inlet/outlet operating pressures are but a part of determining the safe operation of appliances, accurate gas rating is essential.
@martinwright7093
@martinwright7093 2 жыл бұрын
I’m in Cornwall and seen new meter installations with a label stating working pressure will be between 18 and 23 mm.
@henrybartlett1986
@henrybartlett1986 2 жыл бұрын
Very interesting and thanks for this. How does this effect commercial?
@johnh9641
@johnh9641 2 жыл бұрын
At W&W we've been told to allow a 1 minute stabilisation time once in hot water mode and additional appliances running at 50% before recording the WP.
@tomkatgastraining
@tomkatgastraining 2 жыл бұрын
You are correct
@willlomas2725
@willlomas2725 2 жыл бұрын
Thanks for keeping us updated.
@Carl-re6zb
@Carl-re6zb 2 жыл бұрын
Informative and educational as always. Thank you Derek
@simonmander4314
@simonmander4314 2 жыл бұрын
Great video as usual! Be great to hear your thoughts/a video on new guidance for reacting to Co alarm going off. Is it now required that Emergency service has to attend? Is there still scope for engineers to judge it was most likely a faulty alarm and replace it?
@tomstrutton4351
@tomstrutton4351 Жыл бұрын
Nice one, cheers for all these vids
@msuk5957
@msuk5957 2 жыл бұрын
Thank you Derek , Mohamed Hassan
@joeblogs1236
@joeblogs1236 2 жыл бұрын
As always really informative. Thank you!!!.
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
Hiya Derek. Has there been any new alterations since this video. The reason i ask. Yesterday, servicing a boiler. I checked the working pressure at the meter. 16mbar with a hot tap on full. I hadn't even put the fire or the range cooker on yet. Cadent came out. Fair enough they put on all of the appliances and the hot tap. The reading was obviously low. Cadent s response. We will wait a few minutes to let the boiler stabilise. Ok. After 3 or 4 minutes when the hot tap is almost boiling in the sink and the boiler is modulating down to accommodate this, hey presto, he managed to get the 18.5 at the meter. I argued that you have just waited for the boiler to module right down and it is now nowhere near at its maximum capacity. He said thats what they do and left. I tested again after he left and the boiler had cooled down. 16mbar with no fire or range on. I then phoned gas safe later when i got home hoping for a sympathetic ear and that is not what I got. All i got was. I need to understand the igem g13 and that it all depends what you are doing, whether it is a service, commission etc. He said the boiler (it was a 5 year old Vaillant combi) shouldn't modulate down if it is sized correctly and if the boiler was doing that it was wrong for the house. I will admit, the boiler was oversized in terms of kw for the flow rate of the tap. However i went to a 28kw Vaillant today and after the tap had been left on long enough it modulated down. I said to gas safe it would be impossible to size a boiler so accurately that it never modulated down with the hot tap running. I said to gas safe if the water pressure was particularly high there and it hadn't modulated down at all, then the gas pressure was far to low. He then said ignore the 18.5 mbar. There are 2 numbers and the other number regarding whether the gas pressure is safe or not and the 18.5 isnt it. He actually stated if you phone the boiler manufacturer and ask for the safe figure, it will potentially be as low as 9 mbar at the meter. Big long message i know. Im making my own little video of the experience but wondered if you could shed any light on this. Ive always called Cadent at anything towards 18 mbar. Is it actually worth it if you can just leave the boiler on for so long its at 50% of its capacity. Cheers mate and im still wanting to book my un vented cylinder course, i ve just been busy but will come and do it at some point 👍
@tomkatgastraining
@tomkatgastraining 2 ай бұрын
@@northwestgascertificates it seams it’s all about the safe operation of the appliances. If they stay lit with the biggest appliance on full and the others on 50% they don’t seam to care. Igem/g/13 says if it’s reported they have to investigate it but doesn’t say they have to sort it out. Basically you have done your bit it’s now down to Cadent to do theirs if they deem it necessary.
@northwestgascertificates
@northwestgascertificates 2 ай бұрын
@@tomkatgastraining very true. Gas safe said that as well. "You ve told Cadent. You ve done your job, Its on them, stop worrying about it" 🤣 Im still convinced there is a supply issue. All the pressures seem low and they will do anything to avoid dealing with it. Or they haven't got the money/ man power to deal with insufficient external gas piping. Anyway im going to sleep well tonight, it actually woke me up last night thinking about it 🤣🤦‍♂️
@yasreh5845
@yasreh5845 2 жыл бұрын
Thank you derek as always very helpful. Im glad i subcribed to your channel.
@tomkatgastraining
@tomkatgastraining 2 жыл бұрын
Me too 👍🏻
@yasreh5845
@yasreh5845 2 жыл бұрын
👍
@yasreh5845
@yasreh5845 2 жыл бұрын
@@tomkatgastraining 👍
@stevenyates6732
@stevenyates6732 3 ай бұрын
Gas meters under sinks? Thought I saw something new guidelines?
@zagartolagonda
@zagartolagonda 2 жыл бұрын
I thought the G was ‘guidance’, as opposed to UP, like IGEM/UP/1B, which is ‘user procedure’?? Thanks for the update! 👍🏻
@John-oq7ms
@John-oq7ms 2 жыл бұрын
Well that’s a bonus. It’s about time too.
@joshd790
@joshd790 2 жыл бұрын
Cheers for the update
@mgbroadsterJ
@mgbroadsterJ Жыл бұрын
Do they test the regulator first ?
@daz3745
@daz3745 2 жыл бұрын
Any idea where I should I study for my Gas Safe virtual inspection? 24 questions I think.
@MohammedAli-xh6zs
@MohammedAli-xh6zs 2 жыл бұрын
Thank you Derek
@MohammedAli-xh6zs
@MohammedAli-xh6zs 2 жыл бұрын
M.ali
@raul835
@raul835 2 жыл бұрын
Appreciate the update
@leeevans369
@leeevans369 2 жыл бұрын
Great video thanks for keeping us informed 👏👏👏
@WediMeasho.AbbeyHouse
@WediMeasho.AbbeyHouse 2 жыл бұрын
Thanks for the amazing video again ❤
@Elfin4
@Elfin4 2 жыл бұрын
Can you tell me if an external Gas Meter box should be replaced or repaired if an extra knock-out hole for the gas entry has been removed but the hole is not used and left blank? I note the Gas Safe Register says holes bigger than 10mm should result in the box being replaced. But what if this defect has not been picked up until the purchaser takes possession? Should the gas meter be disconnected temporarily to allow a new box to be installed or is it acceptable to put a plastic patch over the knocked-out hole?
@shaunfoley4692
@shaunfoley4692 2 жыл бұрын
as far as im aware the repair of a 10mm hole is for a box built into a cavity wall where it is directly terminated within the cavity, a hole at the front of a box in the allocated cut out wouldn't require a repair or exchange as it hasnt damaged the integrity of the box
@shaunfoley4692
@shaunfoley4692 2 жыл бұрын
and more importantly wouldn't allow gas into the cavity if there is a leak within the meterbox
@Elfin4
@Elfin4 2 жыл бұрын
@@shaunfoley4692 Yes but it would also allow pests an entry point into the box
@shaunfoley4692
@shaunfoley4692 2 жыл бұрын
@@Elfin4 nothing a bit of non setting compound cant stop my friend, cant say ive seen anything to suggest we need to take potential pests into account with regards to meterboxes, certainly not to extend that it requires changing for safety reasons but by all means keep asking, bs 6400 is for meter installation and i think bs 8499 (could be wrong) for meter box standards, maybe they might shed more light
@martinwright7093
@martinwright7093 2 жыл бұрын
It’s not completely clear to me what is meant by integrity of the box. If the door keeps blowing off in the wind or the door is missing is this an AR situation? Similarly an unused hole to outside. Replacing a built in box is not always straitforward.
@samchappell233
@samchappell233 2 жыл бұрын
👍 thanks for the update
@frankkelly6353
@frankkelly6353 2 жыл бұрын
Gis a clue on the January changed...?
@pablox3783
@pablox3783 2 жыл бұрын
Can you shed any light (apart from the obvious)on why IGEM make you become a member and purchase each standard for £80+ . Surely this restriction makes us less safe and less compliant! I for one cannot afford to purchase each document every time i come across a specific situation that needs clarification.
@tomkatgastraining
@tomkatgastraining 2 жыл бұрын
All are free to download off their website 👍🏻
@pablox3783
@pablox3783 2 жыл бұрын
@@tomkatgastraining the ones you have mentioned might be but ‘all’ are not free. Specifically ones for commercial applications.
@krzysztofweyer
@krzysztofweyer 2 жыл бұрын
Thank You
@garethbodsworth5756
@garethbodsworth5756 2 жыл бұрын
Cadent are only responsible for services if they have a service agreement with the supplier. Not all suppliers have this so may use contracts to cover there meters and regulators
@davidrobbins9401
@davidrobbins9401 2 жыл бұрын
Thanks 👍👍 great 👍
@davidrobbins9401
@davidrobbins9401 2 жыл бұрын
Tha KS for putting these videos out
@zali1457
@zali1457 2 жыл бұрын
Nice one 👍
@muzzz33
@muzzz33 2 жыл бұрын
Great video once again , although you say the GT will have to do something about low pressure,I like your optimism here,it's not what the document suggests . Supply requires further investigation. The GT will recommend the best course of action working in conjunction with the RGE to pragmatically address the situation and explain this to the customer/RGE with associated timescale. Looks like they can still go ,nah nothing to see here ,move on .
@paulgannon3261
@paulgannon3261 2 жыл бұрын
Great went to a service yesterday. Never done it before and it is its 1st service. 19.7 working and 16.2 at the inlet of the ideal instinct 2. Guess what in the Benchmark the installer has claimed inlet pressure as 20mbar so definately telling porkies here. Ideal say they would be OK with it but if it breaks down and the issue is with pressure the guarantee is void.
@shaunconnor7525
@shaunconnor7525 2 жыл бұрын
How does that make sense ? They say there fine with it but they wont cover it on warranty thats total bullshit
@paulgannon3261
@paulgannon3261 2 жыл бұрын
@@shaunconnor7525 I agree they should say no ID it as it is not performing as per MIs but you know I have had that much aggro this year with registered installers and what they leave. 44 years in the trade is long enough and standards are not getting better even ACS has made no difference.
@marcinmasalski4183
@marcinmasalski4183 2 жыл бұрын
👍 Marcin Masalski
@plumbertime
@plumbertime 2 жыл бұрын
The amount of times I get sgn turning the hot water tap on, on a heat only boiler and saying it’s fine is shocking. They need better training!
@SuperWayneyb
@SuperWayneyb 2 жыл бұрын
🤘😎🤘
@parenteseswebdev
@parenteseswebdev 8 ай бұрын
Igem isn't free for downloads of 11 or 13
@tomkatgastraining
@tomkatgastraining 8 ай бұрын
They are from igem website
@mervinpermalloo8589
@mervinpermalloo8589 Жыл бұрын
MP 06/02/23
@jockster5525
@jockster5525 2 жыл бұрын
Many thanks for your efforts ☺️
@tommacallister731
@tommacallister731 2 жыл бұрын
Cheers for the update
How to Fight a Gross Man 😡
00:19
Alan Chikin Chow
Рет қаралды 20 МЛН
When Cucumbers Meet PVC Pipe The Results Are Wild! 🤭
00:44
Crafty Buddy
Рет қаралды 62 МЛН
FOREVER BUNNY
00:14
Natan por Aí
Рет қаралды 36 МЛН
It is cheaper to leave your  heating on 24/7, true or myth
11:30
Tomkat Gas Training
Рет қаралды 255 М.
Medium Pressure Tightness Test - NGCFE
10:09
Allen Hart
Рет қаралды 16 М.
Gas Rates Everything You Need to Know
29:16
Pass Your Gas
Рет қаралды 7 М.
Tech Talk - Episode 1 - Gas Safe Register
14:09
Gas Safe Register
Рет қаралды 2,8 М.
All you need to know about a gas safe inspection.
16:37
Tomkat Gas Training
Рет қаралды 5 М.
How to Fight a Gross Man 😡
00:19
Alan Chikin Chow
Рет қаралды 20 МЛН