TIA Portal absolutni encoder singlturn and multiturn-position and speed reading PROFINET telegram 82

  Рет қаралды 5,286

PLC programming

PLC programming

Жыл бұрын

TIA Portal absolutni encoder singlturn and multiturn - position and speed reading PROFINET telegram 82
‪@muhamedpasic83‬

Пікірлер: 11
@sonicgetaway5243
@sonicgetaway5243 Жыл бұрын
Hvala zemljace za video. Evo taman se borim sa AFM60a, pa cu probat tvoju soluciju :)
@user-po2dg1rt4v
@user-po2dg1rt4v 5 ай бұрын
Excellent video but slight error. The number entered at LADDR is the hardware address as found in the "System Constants" and not the physical address of the inputs. Your video at the end shows a decimal number which converts to Hex 8090 this has to be at 0 for correct operation. Thanks for the video though it was very useful. Hope this helps anybody else who uses it.
@vorapobautomation9760
@vorapobautomation9760 Жыл бұрын
How to use this encoder control speed of S120 servo motor and calculate speed in m/minute with external profinet absolute encoder and roller diameter 30 cm. ?
@Paul122M
@Paul122M Жыл бұрын
Can I use a 3 phase AC motor with external encoder to handle position?
@muhamedpasic83
@muhamedpasic83 Жыл бұрын
It can be used for some less precise applications, but it is not practiced. The three-phase asynchronous motor is primarily intended for speed control. As for the position, it is questionable how much precision it can achieve, for some precise applications it certainly cannot
@suriyat8773
@suriyat8773 2 ай бұрын
Absolute Encoder with PLC S7 1200
@muhamedpasic83
@muhamedpasic83 2 ай бұрын
same procedure
@tanannguyen9498
@tanannguyen9498 Жыл бұрын
Can you tell me why data type of NIST_A in DB1 is Dint and DB2 is word? In Document it is 16bit?
@muhamedpasic83
@muhamedpasic83 Жыл бұрын
There should be WORD in DB1 as well, typo, but it won't cause any big problem, only more memory is allocated. So there should be WORD (16 bit) in DB1 as well.
@tanannguyen9498
@tanannguyen9498 Жыл бұрын
@@muhamedpasic83 tks Bro
TIA Portal SINAMICS S120 hardware configuration
15:31
Muhamed Pasic
Рет қаралды 1,6 М.
I'm Excited To see If Kelly Can Meet This Challenge!
00:16
Mini Katana
Рет қаралды 29 МЛН
Spot The Fake Animal For $10,000
00:40
MrBeast
Рет қаралды 193 МЛН
Программирование ПЛК. 12.Таймеры.
17:47
Андрей Кулагин
Рет қаралды 35 М.
Why The Windows Phone Failed
24:08
Apple Explained
Рет қаралды 220 М.
How to program an Encoder with PLC
9:33
Nirtec EasyPLC Software Suite
Рет қаралды 23 М.
Siemens S7-1200 PLC Encoder Wiring and Fault finding tips. Eng
12:23
How to Connect Encoder with S7-1200 --- HSC High Speed Counter--- TIA Portal
8:19
Motion Control: Servosistema S120. Descripción y puesta en marca con TIA Portal (I)
18:25
How to connect Encoder with S7-1200 ? || High Speed Counter HSC || TIA PORTAL || Lesson#13
5:18
PLC Programming Tutorials Tips and Tricks
Рет қаралды 90 М.