am just on my gas engineering journey and your tutorials are explaining it better then the text books :)
@tomkatgastraining Жыл бұрын
Thanks and good luck on your journey 👍🏻
@jonathansharples4955 жыл бұрын
Hi Derek, love your tutorials, im an ex pupil of yours from 20 years ago and made a good career thanks to your interesting and informative tutoring. Keep it up.
@tomkatgastraining5 жыл бұрын
Jonathan Sharples hi Jonathan remember you well , remember giving you a certificate spelt wrong lol
@sansp4242 жыл бұрын
Thank you Derek, your step by step tutoring has been very helpful in understanding the whole process.Hats off Sir.
@len55093 жыл бұрын
Recert in a few days so good to refresh . Thanks Len.
@rajan246 Жыл бұрын
Marvellously illuminating to see a 5440 in action (from a baby heating engineer chewing on his ACS). Thanks Derek and Tomkat.
@Smiley-vp2pn3 жыл бұрын
Once again Derek ,cant thank you enough for your time making these videos .Great knowledge and very well put to understand .Please keep going .Top man .
@leaturk113 жыл бұрын
Got my renewal next week, very helpful. plz keep them coming.
@tomkatgastraining3 жыл бұрын
Good luck with your ACS let me know how you get on 👍🏻
@mohammednadeem72743 жыл бұрын
Great video on flue flow test Derek, you pick up something new every time you watch it.. 😂😂🤣🤣👍👍
@simonfrancis54583 жыл бұрын
Well done Sir, you clearly received the same old school training as me ( with updates ! ) Same lingo, even the 'Snotters' I retired on 28 th Dec 2020 after 43 years in the Gas industry but always learned something new everyday. Incidentally, on the question of wether to tightness test or not on servicing, I used to have a saying.... "if you put the pipework under strain or stress then test"
@MacLennan-A2 жыл бұрын
Brilliantly demonstrated. Love the videos, keep up the good work.
@kazimmohseni69133 жыл бұрын
Very useful thanks for explaining spillage test so much enjoyed keep getting well mr legend.👍👍👍👍👍👍👍👍👍👍
@jagjitsingh-vd3mj Жыл бұрын
Very helpful all the video thanks for new gas engineer and trenne
@1414141x4 жыл бұрын
Re-aligning the closure plate can be a pain when it has been moved umpteen times over the years. So what I do is before I remove it I get a straight edge and mark small pencil markson the wall either side of the closure plate - left and right - in line with the spigot opening, and the same with the vertical parts of the spigot opening, left and right - I mark the wall slightly in line with these. Then when it comes to putting the closute plate back on I have marks on the wall to help me position correctly.
@madmaycon253111 ай бұрын
Very good explanation, thank you very much Derek !!!💯👊
@Garlicandginger3 жыл бұрын
very good Derek, just what I need before my ACS, watched many videos 👍👍👍😁
@chrispulyk3 жыл бұрын
Great videos, really helping me out for my ACS exams coming up!
@mj0n4id364 жыл бұрын
Not the first time I’ve watched this. Fantastic video. Love it. Very clearly explained. Great step by step guide for us beginners. Thanks Derek. Asian Jon. Training.
@Davyboy18014 жыл бұрын
Very informative videos, Derek. Great stuff.👍
@bigbadchillybear4 жыл бұрын
Thanks for this vid.i have my gas renewal test coming up in February 😭.I dont see many of these fires about anymore And this was very helpful.👍
@tomkatgastraining4 жыл бұрын
XxxFaZeFramexxX good luck in February and thanks for watching cheers
@piotrmarchwacki34144 жыл бұрын
Excellent video, very useful information. Thanks Derek. Polish Peter - trainee at TomKat😃
@adrianJUPANU2 жыл бұрын
Really Helpful, Big Thanks 👏👏👏👏👏
@dvsnbanda2 жыл бұрын
Thanks for another great video
@pablogarciafernandez11853 жыл бұрын
Very useful. Thanks Derek
@joaovittoria25333 жыл бұрын
very well explained, thank you!
@mohammednazir83073 жыл бұрын
Great video once again
@simoncarpenter91194 жыл бұрын
Thanks another top video.
@miralemcatibusic5113 жыл бұрын
really good, one thing that could be explained better is how you go about checking full length of flue while holding the pellet rather then dropping it and completing the visual . still very good
@antoniogalluccio4213 Жыл бұрын
2 man operation
@shanea204517 күн бұрын
Great video thanks
@monikanader94544 жыл бұрын
Very informative video 👍
@aaronjoyce19804 жыл бұрын
Just watched top vid Derek 👍 Aaron trainee 😁
@vladimirstafasani46303 жыл бұрын
Very very good video👍
@antoniogalluccio4213 Жыл бұрын
Can the wood of the frame for the plasterboard touch the blocks or there has to be an air gap within the studs and blocks a s well?
@sanjk91162 жыл бұрын
Brilliant as usual. So you have a series where you do service on back boiler and fire? I am slightly concerned about the methodical approach to this., Its my understanding that I do an initial tightness test prior to removing the fire, then, well then I am slightly confused, there is so much discrepancy between engineers, some say to do a "mini tightness test at gas valve" and a final tightness test once back boiler has been serviced and everything replaced? Is there a video you have done on BBU service that clarifies this? Thanks
@tomkatgastraining2 жыл бұрын
No I haven’t done one yet sorry
@sanjk91162 жыл бұрын
@@tomkatgastraining no worries I dont suppose you have the time, can't find one anywhere online.....hard to come by I guess
@rivkiroyde43624 жыл бұрын
Thanks Derek! Benny
@marccrowther72573 жыл бұрын
great video mate marc crowther
@garlic15585 жыл бұрын
Best explanations
@bradleyduffett465110 ай бұрын
Very helpful 🙏
@samir00070855 жыл бұрын
Thank you sir I am on training and it is very very important for me thanks for details full full appreciate thank you sir
@tomkatgastraining5 жыл бұрын
sami m thanks for watching cheers
@abiolaquadry17123 жыл бұрын
Thank you Derek
@chrisjones45002 жыл бұрын
Thanks Derek..
@rickabitia3 жыл бұрын
Cheers Derek 👍🏼- Ricky Skolosdra
@shannonj1000 Жыл бұрын
Question how can you go into the loft if you are holding the smoke pellet surely you would need to put it a the bottom? Please can you confirm..
@tomkatgastraining Жыл бұрын
It take a while for the smoke to travel up the chimney but if the chimney is leaking in the loft you will see the smoke because it hangs around for ages so once the pellets have finished you the go around the house and loft looking for smoke.
@hatemmimouni70153 жыл бұрын
Thank you so much
@higeridgeronbo24 жыл бұрын
Hi Derek as part of a service a flue flow test much be carried out on gas fire where do you carry out a flue flow test on a gas fire stove is it inside the stove itself as Ive looked at some MI and its not clear many thanks
@tomkatgastraining4 жыл бұрын
It will tell you on the data badge and the MIs but most are at the draft diverter at the back
@higeridgeronbo24 жыл бұрын
@@tomkatgastraining Thats for flue flow test and spillage test at the back of the draft diverter cause i know all the spillage tests are done at the back thanks
@arronthomas61773 жыл бұрын
Where do you do a flue gas anerlasis test on these ?
@chikemadekwe43423 жыл бұрын
Good vid, thanks. Bear in mind you have an accent so if you use the predictive txt please ammend it coz couldn't understand a few words. I had an experience when a gas fire was live due to bad wiring in the house so I always test for current first. What say ye?
@atiqyy4 жыл бұрын
Hi Derek I am watching most of your video it is very helpful could you plz make one of the most wanted video for the new engineer which is MULTIMETER USING would be much appreciated,
@tomkatgastraining4 жыл бұрын
Thanks for watching cheers
@julianreading5 жыл бұрын
Currently Gas Safe training, thank you for a very detailed interesting video "Subscribed" :)
@tomkatgastraining5 жыл бұрын
Julian Reading thank for watching and subscribing , spillage test next Wednesday
@kovanfarman4 жыл бұрын
I wish I could come for training in your center. I paid 6k in London I'm learning more here than our center In London very sad
@mohammednadeem72744 жыл бұрын
Great video Derek, watched a few times but it's so good for gaining experience and knowledge, I have a question, if in the chimney mortar fangs are showing, is that classed as NCS. If yes then why do we class it as NCS. Just a bit confused with that. If you can please elaborate your expertise on it, it will be appreciated. Thanks derek 👍👍
@lostinthoughtscalminsilenc81679 ай бұрын
Why did you test with and without he case?
@antoniogalluccio4213 Жыл бұрын
Can't you just purge by lighting the fire? So it is not work and you don't need to check for leaks? Cause if the volume of gas in the premises is over 0.02m³ but less than 0.035 you're anyway not allowed to do it through a loose fitting and you anyway need to use your appliance ignition system isn't it?
@Ed-fp9rx Жыл бұрын
what type of fires actually have closure plates then? radient? inset? decorative?
@tomkatgastraining Жыл бұрын
Radiant
@Ed-fp9rx Жыл бұрын
@@tomkatgastraining okay thanks, so inset live effect and decorative don't?
@tomkatgastraining Жыл бұрын
@@Ed-fp9rx correct
@arianxhebraj61074 жыл бұрын
THANK YOU DEREK!!!!
@osmelmuhendislik8073 жыл бұрын
Hi, if there are faulty starter blocks and snotts between blocks in precast flue but when we try smoke match and smoke pallet are successfully. Is this precast chimney pass within this senario?
@tomkatgastraining3 жыл бұрын
If it pass flue flow and spillage you would advise that the faults are corrected ASAP
@osmelmuhendislik8073 жыл бұрын
@@tomkatgastraining if customer don’t want to repair it from me can I leave this property in this situation. This is not id situation and don’t mandatory remove the appliance isn’t it
@tomkatgastraining3 жыл бұрын
@@osmelmuhendislik807 if the customer doesn’t want you to repair it then just note it on the paperwork
@keithparkin59214 жыл бұрын
Hi can you cover notching in joists cheers
@herrklamm14544 жыл бұрын
What is a flange? In my procedure it says turn off flange if it is connected to the chimney? 🤷🏻♂️
@lostinthoughtscalminsilenc81673 жыл бұрын
What does the spillage test actually test?
@tomkatgastraining3 жыл бұрын
To see if products of combustion are not spilling back into the room
@abdulh634 жыл бұрын
So helpful thank you!
@rayhurrell17223 жыл бұрын
Ray hurrell getting ready for november
@spritguru26953 жыл бұрын
What should the twin wall be sealed with? The outer skin…
@tomkatgastraining3 жыл бұрын
You don’t need to seal the outer skin of a twin wall system
@moulesanctuary4 жыл бұрын
Do you have to shut the doors and windows for a smoke bomb test or is it just spillage you need tio do that .. ?
@tomkatgastraining4 жыл бұрын
moulesanctuary both
@joegibb31914 жыл бұрын
Tomkat Gas Training just watching part 2 now
@abuadammemon39684 жыл бұрын
On this particular video while i am watching I CALLB*DEREK* AND replied me .so nice of him .GOD Bless him.very helpful.
@hatemmimouni70153 жыл бұрын
Thank you
@rayc15035 жыл бұрын
Always always remember regulation 26.9. If you carry out checking the affectiveness of the flue. The supply of combustion air. Operating pressure & heat input & safe functions of the pipework and appliances. You as an engineer will sleep easy at night. Safety it critical there's no second chances. Remember once you're GSR you are the competent person. You don't want any comeback on yourself. Reg 26.9 isn't for quoting regs it's for peace of mind, stay safe ✌
@leaturk113 жыл бұрын
Does anyone know a website to download free gas fire manuals?
@mohammednadeem72744 жыл бұрын
Excellent video Derek, very useful information for us trainees. Trainee at tomkat.
@mj0n4id364 жыл бұрын
Great video Derek. Thanks for upload 👍🏻 Asian Jon. Training.
@tomkatgastraining4 жыл бұрын
Mohammad Jonaid 😂🤣🤣🤣😘
@gasfitter785 жыл бұрын
I mark the closure plate before i take the tape off
@egservices-plumbingandheat55703 жыл бұрын
it is the female upwards not the male on the flue pot. please correct it. Reference: 14:50. otherwise, the condensate from the chimney will run in the flue joint
@tomkatgastraining3 жыл бұрын
If you are talking about twin wall it’s male up female down single wall flue is female up and male down
@egservices-plumbingandheat55703 жыл бұрын
@@tomkatgastraining I was referring to the flue block. 14:50
@tomkatgastraining3 жыл бұрын
@@egservices-plumbingandheat5570 the flue blocks are made that way they even came with a sticker on the blocks to show you the correct way up the manufacturers even gave me an installation sheet and finally you couldn’t get it wrong if you tried as the flue block wouldn’t sit on the cover block or the transfer block.
@lostinthoughtscalminsilenc81673 жыл бұрын
What is size of heat shield?
@tomkatgastraining3 жыл бұрын
What heat shield ?
@lostinthoughtscalminsilenc81673 жыл бұрын
@@tomkatgastraining for a gutter
@tomkatgastraining3 жыл бұрын
@@lostinthoughtscalminsilenc8167 heat shields aren’t need for condensing boilers because of the low temperature so what appliance are you thinking of
@lostinthoughtscalminsilenc81673 жыл бұрын
@@tomkatgastraining OF
@tomkatgastraining3 жыл бұрын
@@lostinthoughtscalminsilenc8167 an open flued appliance can not terminate near a gutter it has to go above the gutter 1.5m off the pitch of the roof or 600mm above the ridge
@samchappell2333 жыл бұрын
👍👍
@shanehunt83602 жыл бұрын
👍 Shane Hunt
@hafizimran60213 жыл бұрын
Nice1
@carsonwilliams63193 жыл бұрын
👍🏻✅
@secondchance44983 жыл бұрын
Chris Taylor
@suewarrington81552 жыл бұрын
👍Sue Warrington
@marksimpson36674 жыл бұрын
👍
@KW0NLINE3 жыл бұрын
Kade W
@jon-paulward45802 жыл бұрын
Jon-Paul Ward
@mgbroadsterJ Жыл бұрын
I don't service gas fires . They can pass one day and fail another .