We Didn't Expect THIS at the Irish Electrical Wholesaler...

  Рет қаралды 20,772

eFIXX

eFIXX

Күн бұрын

Electricians rely on electrical wholesalers for their essential supplies, making them the backbone of the industry. Wholesalers offer everything needed for electrical installation, ensuring smooth job workflow. In this video, we explore an Irish electrical wholesaler and compare it to what we see in the UK. Join us for an enlightening look into the world of electrical wholesalers.
Thanks to ‪@Ledgrouprobus‬ for arranging this visit and the excellent team at Edmundson Electrical in Dublin.
Check out the new COB RGB LED Strip from Robus
👉 • Stop Soldering NOW : N...
==================================
00:00 Edmundson Electrical Dublin.
00:26 What's the coffee like.
01:05 Mystery box
02:06 Coffin box
02:34 Irish consumer units
03:26 Irish cables
04:05 Pink cables
04:45 IS10101 ?????
05:03 Meanwhile, in the Robus section
06:15 EV Chargers & Fireman's switches
08:27 Time for a round of golf
08:45 Underpants in the mystery box
09:10 Wago's in Ireland?
09:40 The same but different!
================================
More electrical stuff from around the world
Spain - • Electrical Wiring in S...
Italy - • Electric Wiring in Ita...

Пікірлер: 108
@efixx
@efixx Жыл бұрын
Check out the new COB RGB LED Strip from Robus 👉 kzbin.info/www/bejne/kH6ygoRnjZeCnc0
@yaboi7376
@yaboi7376 Жыл бұрын
Ireland is miles ahead of most countries it seems
@therealdojj
@therealdojj Жыл бұрын
Seems much more relaxed But also more strict on what you can and can't do
@hopkins_electrical
@hopkins_electrical Жыл бұрын
First wholesaler Iv ever seen in Ireland with coffee darts and golf, think they may have put it in abit for ye 😂😂
@danieleckersall5454
@danieleckersall5454 Жыл бұрын
Not at all put on Jerome. You're welcome in any time to check us out and throw a few darts, have a coffee whilst we get your order ready 🙂
@arcadia1701e
@arcadia1701e Жыл бұрын
The one thing i do want from this is the earths in t&e being the same mm2. Would make achieving zs much less of a pain.
@IAmThe_RA
@IAmThe_RA 11 ай бұрын
Is it against the regs i use that irish t&e in the UK?
@heffo1992
@heffo1992 Жыл бұрын
Great video, you should try organise to do a video with the ESB, they would have shown you some of the power plants.
@efixx
@efixx Жыл бұрын
We’d love to do that - we’ll be back!’
@heffo1992
@heffo1992 Жыл бұрын
You could also do a video on two way switching, we don't use three core and earth!
@Vegan123
@Vegan123 Ай бұрын
You could try Ardnacrusha on the river Shannon - first hydro power station in Ireland - built by Siemens back in the day - It's why Ireland use 230V - Built in 1920 by Siemens - en.wikipedia.org/wiki/Shannon_hydroelectric_scheme
@tonywebb9909
@tonywebb9909 Жыл бұрын
Not just Ireland, fixed equipment is anything over 13amps thus requires a double pole isolater simultaneously accessible to the equipment (BS7671) you might be asked to retrofit every EV charger you ever installed. It's just like a shower or an oven or AC unit
@Recessio
@Recessio Жыл бұрын
Great bunch of lads showing you around
@cal5566
@cal5566 Жыл бұрын
Always called a Hager j501 a coffin ⚰️ because of the shape
@irechopshop
@irechopshop Жыл бұрын
Having served my time in the UK before moving over in the early 90’s, totally different in many ways, 6243y 3 core T&E go to way of wiring 2 way switching in UK, never used here, capping for cables very rarely used oval conduit used. 1.0mm never used 1.5mm minimum even for lighting
@efixx
@efixx Жыл бұрын
Didn’t know that about the 2 way switching - are contactors used instead?
@irechopshop
@irechopshop Жыл бұрын
@@efixx no PVC PVC single and twin brown
@richardwalsh5882
@richardwalsh5882 11 ай бұрын
@@irechopshop not PVC/PVC anymore - minimum standard for all cables is Dca, -s2, d2, a2. It's a LS0H version rather than PVC.
@solidus784
@solidus784 Ай бұрын
@@efixx No switch feed one side, feed at the other strappers in between. The English way of having the feed and switch feed at both switches is never done here.
@richardhalliday6469
@richardhalliday6469 Жыл бұрын
Enlightening!
@davidcooke3081
@davidcooke3081 11 ай бұрын
We don't use NYM-J in Ireland anymore, it's NHXMH-J now. It's a LSFZH version
@andrewhughes8410
@andrewhughes8410 Жыл бұрын
Brilliant video.
@BillsCountrysideAdventures
@BillsCountrysideAdventures Жыл бұрын
Near enough is good enough in Ireland, did make me chuckle 😅
@MervynPartin
@MervynPartin Жыл бұрын
Good choice of Edmundson, thus allowing a really good comparison with the UK stores- the golf and darts made me chuckle.. I was wondering if branches in Northern Ireland operate in a similar fashion? I didn't quite follow how their wiring regs compare with ours- I know that you have visited installations in Europe so perhaps one of your videos could examine the differences between UK and other European standards. Does RoI use ring circuits like us?
@IAmThe_RA
@IAmThe_RA Жыл бұрын
Is it illegal to use Irish/European cables in the UK?
@sween187
@sween187 Жыл бұрын
Just checked one of my rooms and it's a radial , if that helps, think they are moving away from ring as it can be dangerous, if it breaks you could draw too much current down a cable not fit for it.
@efixx
@efixx Жыл бұрын
They aren’t recognised with a BS number or harmonised standard so would be a departure from the regs
@jimbobwilkinson9706
@jimbobwilkinson9706 Жыл бұрын
Rings are not against regulations but you’ll hardly ever come across them
@richardwalsh5882
@richardwalsh5882 11 ай бұрын
Ring final circuits are permitted - protected by a 32A MCB or 35A fuse, although are very uncommon. However unfused spurs have been prohibited for many years.
@Mike_5
@Mike_5 Жыл бұрын
The Irish well ahead of the game and fully on spec with the regs as usual but really non branded Pot Noodles is that even a thing in the UK or Ireland?
@efixx
@efixx Жыл бұрын
Will try them on next visit 😉
@alanwhite4427
@alanwhite4427 Жыл бұрын
Nice video, hope you had time for a pint 😂😂
@andysims4906
@andysims4906 Жыл бұрын
I wouldn’t have time to play games and drink coffee at my wholesalers. All I want to do is get my job done . More work time more money and more free time when I finish early
@efixx
@efixx Жыл бұрын
Just think of the prizes in the mystery 📦 box
@johnwaby4321
@johnwaby4321 Жыл бұрын
Seems strange as ireland not to far away and some things are very different 🤔
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
Wow what a difference. It is compared to the UK I hope you enjoyed your time in my home country, Great video Gordon as always 👍
@2012edunne
@2012edunne Жыл бұрын
You must have brought the good weather over to Dublin.
@efixx
@efixx Жыл бұрын
Thought it was always sunny in Dublin 😃
@BenCos2018
@BenCos2018 Жыл бұрын
​@@efixx haha And you stole the sun from benidorm in spain for a bit lol
@georgen.8027
@georgen.8027 Жыл бұрын
Glad everyone had their hi-viz on to avoid being hit by... someone walking too fast to the counter?
@efixx
@efixx Жыл бұрын
😂
@AF-O6
@AF-O6 Жыл бұрын
Electrical components on our side of the Atlantic seems crude compared to yours. Ours is safe, while yours is safe and elegant.
@IAmThe_RA
@IAmThe_RA Жыл бұрын
Which countries do you mean by "yours" and "ours"?
@key_gen
@key_gen Жыл бұрын
I kinda want to see the "pig willies" wire plug he mentioned 😂
@efixx
@efixx Жыл бұрын
We’ll try to get some
@aaron74
@aaron74 Жыл бұрын
Come on over to the USA and see the 120V world of materials
@efixx
@efixx Жыл бұрын
We’d love to 👍
@IAmThe_RA
@IAmThe_RA Жыл бұрын
Jurassic world 🤣
@86abaile
@86abaile Жыл бұрын
It was interesting, but very difficult to hear. You need a hand held microphone.
@MrCameron8841
@MrCameron8841 Жыл бұрын
Where are you in Ireland? I would go to meet you guys
@BenCos2018
@BenCos2018 Жыл бұрын
They were in Dublin based on another reply Likely back in the uk now though at a guess
@efixx
@efixx Жыл бұрын
Will be back 👍
@MrCameron8841
@MrCameron8841 Жыл бұрын
@@efixx when? I really wanna meet you guys
@hazzt6298
@hazzt6298 Жыл бұрын
wow Ireland electrical cable very similar to what we use here in Australia twin core and earth TPS
@efixx
@efixx Жыл бұрын
We hear about all the innovations you gave in Oz - we’ll have to visit 😉
@IAmThe_RA
@IAmThe_RA Жыл бұрын
Your earth is much smaller like 2.5mm².
@hazzt6298
@hazzt6298 Жыл бұрын
@@IAmThe_RA yeah for mainly used for power points and lighting we use 1.5mm
@IAmThe_RA
@IAmThe_RA Жыл бұрын
@@hazzt6298 I mean all the 3 conductors in Irish cables are of the same size which is not the case in Australia.
@hazzt6298
@hazzt6298 Жыл бұрын
@@IAmThe_RA that is true earthing conductors a slightly smaller in diameter but you look in the uk the earthing conductors don’t have a sheathing from the manufacturer process only after is installed can you elaborate on this more please thanks 🙏
@eoin730
@eoin730 Жыл бұрын
If you’s don’t use nymj in the uk what do you use for running commercial circuits on cable trays and such? Hardly twin and Earth?
@Nispark
@Nispark Жыл бұрын
Hi tuff
@Marcel_Germann
@Marcel_Germann Жыл бұрын
@@Nispark There's probably a difference in price between both. NYM-J is actually a national German cable standard, and Hi Tuff is a product of a single manufacturer. NYM uses actually the old pre-harmonisation german cable designation system that describes how the cable is constructed from the inside to outside. N=normalised cable type Y=wire insulation made of PVC M=mantle cable And the -J tells us that one of the cores is a green/yellow insulated wire. The other option is -O (big o), there is no green/yellow insulated wire inside. Instead one of a different colour. For example when having 3x1.5mm², on NYM-J you got brown, blue and green/yellow. On a 3x1.5mm² NYM-O you got brown, blue and black. Not a big thing anymore since we bring the CPC now to almost everything, even if not needed now it can be a thing in the future. But back then it was a big thing for light switches. Aluminium conductor is also in that system, that would be NAYM. So NYM is always copper, if someone tries to sell you NYM with aluminium, that's fake cable. Same system applies for NYY cable. And another remnant is the NYIF cable, which is probably only permitted in Germany. But no one uses it here anymore. Flat cable for installation below plaster, PVC insulated wires, rubber sheath. Back then it was cheap, permitted for dry rooms only and not permitted to bring into contact with combustible building materials like wood. Now these days we mostly use NYM indoors and NYY outdoors. And the price advantage isn't that big anymore, and NYM is more flexible in its application than NYIF. NYA single insulated wires for installation in conduit was replaced by H07V-U.
@efixx
@efixx Жыл бұрын
Armoured most of the time which is daft
@Marcel_Germann
@Marcel_Germann Жыл бұрын
@@Nispark Yes, there are several differences. For example the Twin and Earth cables are banned here for several reasons: 1. The CPC must be marked green/yellow over the whole length of the cable. Exception is cables with a concentic CPC, for example NYCY. 2. Smallest permitted conductor size for fixed installation is 1.5mm² copper (for aluminium it is 16mm² since 1973 in West Germany and 1990 in East Germany). So no 1mm². That has no electrical reason, the VDE did that due to mechanical stability of copper conductors. 3. Between 1.5 and 16mm² the CPC must be the same size as the line conductor. Between 16 and 35mm² a CPC of 16mm² is sufficient. 35mm² line or larger a CPC of half the size of the line is sufficient. 4. Stranded conductors have to start at 16mm², smaller conductor sizes must be solid core. And to make the thing complete: We can have socket outlets in bathrooms. Since 1984 they must be protected by a 30mA RCD. And since 1987 by a type A RCD, since the type AC RCDs were banned for new installation back then.
@johnaphone
@johnaphone Жыл бұрын
Currently on a large commercial job, uk, and all power/lighting circuits are wired in the white LSF /LSOH t&e on tray. Its quite common to find it done this way
@geraldhutchings8479
@geraldhutchings8479 Жыл бұрын
Interesting
@aroncells3120
@aroncells3120 Жыл бұрын
Your experience in an electrical wholesaler is Ireland is entirely dependent on the person serving you!! Like if you know what i mean
@truthwillout7909
@truthwillout7909 Жыл бұрын
Ireland seems way ahead in their products and standards.
@filiplubos1981
@filiplubos1981 Жыл бұрын
Influence from the continent
@acelectricalsecurity
@acelectricalsecurity Жыл бұрын
Not really, they may use lsf cable but I bet they don't use lsf conduit, trunking, clips etc, and if that's the case I see no point in using lsf cable. And if you are in a building where the fire has breached the barriers, and fumes are the issue, guess what you will probably be dead by then.
@truthwillout7909
@truthwillout7909 Жыл бұрын
@@acelectricalsecurity your just a fountain of positivity ain’t ya. Always think every little bit counts.
@mrtechie6810
@mrtechie6810 Жыл бұрын
Why is everyone wearing safety vests? Are there a lot of collisions due to fog in the store?
@efixx
@efixx Жыл бұрын
Everyone loves a hivis
@gadgetman36
@gadgetman36 Жыл бұрын
I have heard them referred to as coffin boxes on KZbin before! ⚰️
@efixx
@efixx Жыл бұрын
Do you use them ?
@gadgetman36
@gadgetman36 Жыл бұрын
@@efixx Yes
@banusbaby
@banusbaby 11 ай бұрын
Sound bunch of lads in glasnevin, you couldn't have picked a better wholesales to go into. They need more ginger nut biscuits at the tea station but 😉
@efixx
@efixx 9 ай бұрын
😂
@adventuresofanathan
@adventuresofanathan Жыл бұрын
When did you guys originally go to Ireland lol cos the April Fool's was April 😅
@efixx
@efixx Жыл бұрын
March
@adventuresofanathan
@adventuresofanathan Жыл бұрын
@@efixx well played 👏🏿👏🏿👏🏿🤣
@CrownRider
@CrownRider Ай бұрын
The presenter's first line is about the sunny weather when it clearly isn't....
@alvina69
@alvina69 Жыл бұрын
Interesting video, I’m not keen on the plastic CCU’s though.
@efixx
@efixx Жыл бұрын
Most of Europe uses plastic
@IAmThe_RA
@IAmThe_RA Жыл бұрын
I think they just copied French distribution boards. I like them more especially on wall a wall that is all concrete.
@dueyfinster1708
@dueyfinster1708 Жыл бұрын
🇮🇪🇮🇪
@TheManLab7
@TheManLab7 Жыл бұрын
Any external isolator people will just switch off for shit's & giggles
@efixx
@efixx Жыл бұрын
Sure it happens
@user-iw7yu2xz6k
@user-iw7yu2xz6k Жыл бұрын
سلام عليكم
@2loco
@2loco Жыл бұрын
Pardon my ignorance but isn't Ireland part of the UK?
@Mike_5
@Mike_5 Жыл бұрын
NI only
@IAmThe_RA
@IAmThe_RA Жыл бұрын
It's a republic.
@kw1984
@kw1984 Жыл бұрын
Full country title is The United Kingdom of Great Britain (England, Wales & Scotland) and Northern Ireland. Only the north-eastern part at the top of Ireland is part of the UK.
@JimWhitaker
@JimWhitaker Жыл бұрын
en.wikipedia.org/wiki/Ireland for the full story.
@BenCos2018
@BenCos2018 Жыл бұрын
Nope ireland isn't part of the uk Unless you mean Northern Ireland which is in the uk
Corte y conexión de manguera LED 5050
3:07
Light-Led iluminación
Рет қаралды 150 М.
МАМА И STANDOFF 2 😳 !FAKE GUN! #shorts
00:34
INNA SERG
Рет қаралды 4,9 МЛН
Мы никогда не были так напуганы!
00:15
Аришнев
Рет қаралды 6 МЛН
🌊Насколько Глубокий Океан ? #shorts
00:42
The IMPOSSIBLE Job...I Didn't Know If It Would Work.
13:35
SOTA Electrical
Рет қаралды 33 М.
Why Are People  Leaving Portugal?
18:44
Sweet Nar Nar
Рет қаралды 134 М.
BUYING BARGAIN PROPERTY IN TURKEY
11:00
Mick and Trudie
Рет қаралды 220 М.
I Wasted Money At The Scrap Yard
18:17
N Bundy Electrical
Рет қаралды 15 М.
This is the last straw!!
10:08
Jointech Cabling
Рет қаралды 5 М.
CHEAP Electrician cost this customer £1000s💷
18:43
Artisan Electrics
Рет қаралды 109 М.
Klavye İle Trafik Işığını Yönetmek #shorts
0:18
Osman Kabadayı
Рет қаралды 618 М.
Tag her 🤭💞 #miniphone #smartphone #iphone #samsung #fyp
0:11
Pockify™
Рет қаралды 30 МЛН