Please Like, Share and subscribe my channel to get the regular updates . My channel link... kzbin.info
@pradipchauhan53933 жыл бұрын
🙏😊✍️
@ashishvishwakarma4682 жыл бұрын
Burn through occurs when??? A. Large root face B. High arc voltage C. Large root gap D. None of the above
@WeldingNDTInspection2 жыл бұрын
Large root gap
@ashishvishwakarma4682 жыл бұрын
@@WeldingNDTInspection wil high arc voltage be not a answer
@ashishvishwakarma4682 жыл бұрын
@@WeldingNDTInspection I am not satisfied sir I think so high arc voltage
@WeldingNDTInspection2 жыл бұрын
@@ashishvishwakarma468 I am outside thats why late reply .. anyway .. see if arc voltage high it could be occur burn through we cant tell sure .. but if root gap is large definitely we can tell burn through could be occur as they are not maintaining the gap as per approved WPS . And in the other hand we can say if root gap is same as per WPS , but current is much more than the requirement sure there will be burn through . and for high arc voltage it will be occur lengthens the arc so that weld bead width, reinforcement and flux consumption are increased as is the risk of arc blow.