thank you sir!! now it makes much more sense as to why i have the same issues nearer my gutters.
@gordonpotts753 Жыл бұрын
Excellent explanation of concrete roof system.
@davidcaldwell4953 Жыл бұрын
The American way of roofing is strange. fixing concrete tiles directly on to the roofing paper is a long term recipe for trouble in UK we fit batten from ridge to gutter .Then battens at fixed gauge parallel so the tiles never touch the paper far better system. The proper way
@fixdroofing Жыл бұрын
Interesting. Sounds like a pretty good system
@neilkennykenny4113 Жыл бұрын
I agree with ye, plus it looks like thers not enough head lap on those tiles, if you look at the water mark it's only barely covering the nail holes, and who uses a blob of rendering to flash around a pipe.
@everythinghomerepair1747 Жыл бұрын
@@neilkennykenny4113 that’s not the normal way of doing tile in America. In Arizona tile roofs have a proper lead flashing around each vent pipe. They also use wooden battens under the rows of tile like in the UK.
@tonyford5326 Жыл бұрын
We have a similar tile in England stonewold or Marley modern I’ve just looked at a similar problem on a roof and in my opinion the tile isn’t the problem it’s the gauge dropping the gauge an inch will solve it especially on a lower pitch roof it might add a couple of course’s and the extra weight needs to be taken into account
@ccloutiutube10 ай бұрын
Very good explanation. Thank you.
@jamesburton668 Жыл бұрын
This underlay is prehistoric!! I wonder how old the roof is. In the uk we had an underlay similar to that called 1F but that was donkeys years ago. Now it’s all breather membranes n always hang tiles to battens makes no sense laying them to the underlay. Also, where’s the lead slate for the pipe??? They’ve just blathered it with mortar👀 yikes! Not the way it should be done
@ojosverdesrvgt Жыл бұрын
Great information, thanks!
@hansgruber250919 күн бұрын
The issue here is the underlayment has failed , look at the vertical crack next to the vent, unrelated to the horizontal cracks "caused by trapped water"
@neilkennykenny4113 Жыл бұрын
Thanks for the video, we use a very similar flat tile(12x16") to what you have shown here, it looks like there is not enough head-lap on those tiles we usually allow 4" of headlap and no less than a 22.5 degree pitch on the roof and the under felt would not be depended upon to weather the roof, I agree with you that profile tiles are better that flat because the interlocking channel is positioned higher up and so water flow cannot enter the channel as it can with the lower positioned channel on a flat tile.
@davidchi127710 ай бұрын
Tiles and slate are to keep the water out, the under felt is really a dust sheet and a temporary tarpaulin.
@axjohn2 жыл бұрын
I would have loved to see the repair of this area.
@fixdroofing Жыл бұрын
We ended up replacing the lead plumbing vent flashing and re-sealing the area using modified bull and membrane.
@ianhoare289 Жыл бұрын
try using battens
@BradBlake-mp7us8 ай бұрын
Try BattensPlus roof Battens the water flows through does not pond behind it
@russellschneider990711 ай бұрын
LMAO ! Instalation failure! No battons! Code says there must be min. 1*2" minimum wood battons ubder flat tile, with gaps in battons every 4'
@flaman19679 ай бұрын
Thank you for calling him out because I have a flat tile roof in Arizona built in 2018 and I was worried. IF battons are used flat and s style roofs must be equally good.