Fascinating. Never knew what resistors actually did for alarm circuits, thanks for making this extremely easy to understand.
@Deancepticon4 жыл бұрын
Man this video is golden for me. Apprentice fire alarm tech in commercial. And this just made things real clear for me. Thanks a lot
@stormin221711 жыл бұрын
thank you for taking the time to show us ,,I will say thanks for all the thousands that watch your vids.
@snowcatxx878 жыл бұрын
Great video, explained it quickly and efficiently.
@phillipjessop29023 жыл бұрын
Thanks. Been looking for an answer for the need for a resistor. My door contacts also have a resistor between terminals? Don't know why. Also, are resistors directional? Regards Phillip
@Krakology3 жыл бұрын
resistors are not directional. Diodes are. For the reason for your contact to have the resistor across both terminals.. Well had to say without more info.. My first 2 thoughts.. A, maybe normally open contact, b, they are trying to correct the resistance with a seprate resistor.
@MrDumonic Жыл бұрын
Love the explanation. I just use n/c loops. Especially now with wireless. If a wire is shorting out and I can’t use a different pair, sorry time to go wireless. Resistors are mostly used for supervision in commercial circuits where someone may try and tamper with wiring. But that’s more on the really big commercial side. Residential and small commercial we don’t use EOL. I hate EOL’s cause I find it harder to troubleshoot why a zone keeps false’ing. I work better with uninterrupted circuits. I totally understand why you would do this, but it just complicates things. Dealing with resistors at the panel is much more convenient.
@chadrowland52342 жыл бұрын
If it were me, I would have the panel programmed for EOL resistor operation. The resistor offers the best of both worlds. Open and closed circuit operation. And, if you are an alarm hobbyist, the resistor is a must. You can tie resistors in series and do some cool stuff. The resistor is fun to play with in alarm systems. And, especially with fire zones...the trouble condition can be demonstrated to friends and stuff about what a trouble condition would look like on an alarm system. And, you can't do that without a resistor. And, especially if you have smoke detectors in your system, the trouble condition can be used as a reminder to put the smoke detector back. Especially me...everyone has done this, you've done this, I've done this. In fact, every time I do work in my house, I stand on a step ladder or a piano stool and twist off the smoke detector and drop it in a desk drawer and then put it right back when finished. Well, if you don't have the resistor, the trouble condition won't work and then, you could easily forget to put the smoke detector back. I would highly recommend keeping the resistor.
@solitudeesttriste53968 жыл бұрын
still there are a wonderful peoples in this world.thanks man for your help.
@Krakology8 жыл бұрын
+solitude esttriste NP thanks for watching
@rehanzahid96005 жыл бұрын
@@Krakology can you explain about how conventional sounder activated in addressable fire system how sounder get signal from panel through smoke detector please explain or send some link for this
@paulburger28669 жыл бұрын
Thanks for showing why this is better. Now it will be easier to remember whenever I'm in doubt again.
@ianDg-e4pАй бұрын
God bless you, and never doubt yourself when you want to make another video
@dannyf499510 жыл бұрын
I'm installing a new Alarm system in my house (Pima - Hunter PRO), and couldn't understand their explanation about the ELO resistor, till now :-). Thank you so much for helping me understand this issue.
@stevenweii9 жыл бұрын
this is a very useful video, i was trained before and knew the why EOL resistor is a must, but just in theory, you experiment and explain more details and prove what i was trained and told is pretty right..
@ochungochieng88633 жыл бұрын
Good evening. Can you incorporate a maglock into the alarm panel so that we have an intruder detection as well as an access control working togethee
@jdigi785 жыл бұрын
thanks for the video, was very confused why there were a bunch of resistors at the control panel. Turns out whoever did the install years and years ago never watched this video!
@marko78439 жыл бұрын
That's a great demo! My only question is why they bothered to put the "eol" resistors in my control panel, where there's no difference between a closed switch and a short... Just a necessary current limiter?
@Krakology9 жыл бұрын
+Mark O some panels cant be programmed to not look for the resistor.. it needs to see that load.. so people cheat and put at panel.
@MrLibbyloulou3 жыл бұрын
O.k.....i have just bought a jet ski, i need to run a wire from my house alarm panel, about 10ft long to the jet ski, am going to loop a wire too and from the ski, i suppose i would (using two wires) run say my blue out to the ski, with my red, (the wires i use) and could just wire either end to a resistor to do the same job.....? it's only like running them to a magnet.....?.....yes...? and if that would be fine, what resitor would you recommend......thank you for your help.......
@jacksondeans8121 Жыл бұрын
thank you, explained it so much better than my textbook
@jamie14004 жыл бұрын
Hi, can you confirm on a smoke detector that the resistor goes across the positive and negative terminals. If so can I use the spare negative and positive terminals on the device itself?
@RainierWestVideos11 жыл бұрын
I have a nice little supervised (1.8 KOhm) four zone panel built in to a programmable keypad. I ran all my wiring to a closet behind the keypad and thru-walled the keypad feeds to my closet backbox. This mini-panel also has two supervised open inputs (emerg/fire) and a fixed/momentary contact output for aux out. I have two doors that must be individually zoned, that's zone one and two. I have eight windows, four on zone three and four on zone four. Each run was a homer AND each contact was supervised at the contact (1.8 KOhm resistor). Now, I've discovered a problem, as you can imagine. The panel wants to see 1.8K, the series-ed windows on each zone offer 7.2K of resistance which looks like a short to the panel. Do I have to remove three of the resistors on the window contacts so that the panel only sees one resistor? Or maybe, I should have divided by four and put .45KOhm resistors on each window, the combined offering 1.8K at the panel. As long as the zone threshold sees an open (drop of .45KOhm), this should work. Putting the windows in series (at the back box) won't work - do the math. Didn't USP have built-in resistored contacts at one time?
@Krakology11 жыл бұрын
Most people only use one resistor . The rest leave off.
@RainierWestVideos11 жыл бұрын
Kraka069 That was just a fun question. I worked in the security alarm industry for 30 years. The panel I was referring to was a modified MOOSE keypad system. Great little panel. They had some issues with sub-standard power supplies back in the '80's, fixed that and became a pretty good choice for the low end market. I preferred NAPCO (they still around?). Solid performance, many featured and properly priced. They weren't RADIONICS but I preferred their dealer network over RADIONICS.
@Krakology11 жыл бұрын
napco sux. GE or ademco gets my vote
@RainierWestVideos11 жыл бұрын
Kraka069 well, i don't have any idea what panels are good or bad anymore, but we always referred to the junior installers and do it your selfers to ademco. real pro's used napco, radionics, dsl, dsr and accutech before your time. nowadays ademco might be the best, but it was the stepping stone alarm panel of its day.
@TheRealAfroRick11 жыл бұрын
This was excellent. I'm putting the in now to upgrade my home wiring setup. Will ensure no issues.
@SpewNation7 жыл бұрын
I have two words for you.... Great video! the best explanation ive ever seen. Good job
@ruiftavares4 жыл бұрын
Good afternoon, can I please ask for your help? I have a Ademco Microtech Galaxy 8 C055 alarm, and want to attach a GSM communicator to it. It can work with either NO or NC outputs. I just dont kmow in wich terminals I have to connect the communicator to the alarm, and can´t find any schematics online. Can you help me? Thanks in advance.
@seanbrooks501210 жыл бұрын
Kraka, How many of these sets do you think i would need to run an RV refrig, say a 31" lcd, a small water pump and maybe a radio with some surround speakers?
@ESkateLP8 жыл бұрын
+Sean Brooks you need 42
@JohnDoe-ch5pf9 жыл бұрын
thank you for this explanation!! i have asked why to most of the people i have worked with but no one ever could tell me why.
@MrAnhNo9 жыл бұрын
John Doe Because they don't know either or they just don't want you to know . Sad but truth :-(
@donlackie9114 жыл бұрын
If you are in the industry and haven't figured this our on your own, you shouldn't be in the industry. It's not rocket science. The purpose of the EOL is the one of the basics.
@வாழ்கவளமுடன்.காம்2 жыл бұрын
Simple and perfect explanation
@vcholman9 жыл бұрын
Where would a EOL resistor be added if I have window switches wired in series for each room in the house?
@Krakology9 жыл бұрын
+Vance Holman all home run back to the panel or all windows on one wire>?
@vcholman9 жыл бұрын
+Kraka069 If I add a 2K resistor at each window or door location, then wire for example a group of window switches at the panel in series for different rooms, then the panel would see either open or 2K, 4K and 6K when all are closed. How many ohms is each Vista zone setup to measure?
@Krakology9 жыл бұрын
+Vance Holman just the end one needs the resistor ( 2k )
@DiyintheGhetto5 жыл бұрын
Hello Thank you for the video i know it's a older one but it helped me a lot. I never know what the resistors are for. But i saw a lot of other videos of people adding resistors but never say what they are for. So again thank you.
@NathanDelCamp2 жыл бұрын
Thanks for the explanation. Great work brother.
@ghisayawan7 жыл бұрын
Hello I have a DSC 1832 alarm system. I have a motion sensor that keeps tripping the alarm off at times. I replaced the sensor and still the alarm is being set off. Can you please help?
@Krakology7 жыл бұрын
Darin Ghisayawan whats in the room? Animals? Balloons or anything that moves? A/c vents? Whats the environment like?
@ghisayawan7 жыл бұрын
Kraka069 it's in my attic, so there's not much there. No animals, people or anything. The system will arm Ok and then sometime after the alarm will sound, very annoying when it goes off at 3am. Sometimes the zone will be open and it has to be bypassed to arm the system.
@Krakology7 жыл бұрын
Attic is not the place for a motion detector. If you're worried about someone breaking in through the attic to contact switch on your attic hatch
@chrisledbetter37627 жыл бұрын
unless it is a microwave motion detector it shouldn't be in an attic, and if it is microwave, it can go through walls like sheetrock.. and is not normal to use in a residential site....... more than likely it isn't a motion detector in your attic, if it is anything, it is a heat detector, if it is on the alarm, but the fact you can arm it, .... if it is a heat detector, it would be a fixed temperature heat detector and would only be able to go into alarm once, and you wouldn't be able to get it out of alarm to arm it again until it was replaced.............its probably not that...... but you said you replaced the sensor, so I'm guessing you know for sure it is a motion in the attic?.................there are a few different types of motion detectors... Infrared and microwave are the two most common....... no one would put infrared detectors in an attic, it gets hot and stays hot, all the motion would see is red all the time and not pick up body heat.....microwave is usually for commercial jobs, where the motion has to see through boxes and around corners and gets stopped by concrete walls..... people put them in houses sometimes, but not often., ... you said it is going off at night when you sleep and if it is a motion and was programmed as a motion in the panel, it would get bypassed when you arm the system in stay mode to sleep, so a motion anywhere wouldn't set it off at 3 am, if the system was armed and you were sleeping............................. I think what your looking at in the attic isn't connected to the alarm system, its not common to put motions in attics, and an 1832 is a normal residential panel.............. ive seen a lot of homeowners think their AC powered smoke detectors are hooked to the system, or think some other device is part of the alarm, when it isn't...... the only thing I don't understand is what you replaced........... if it turns out to be a microwave detector somehow... they don't just go off with animals or people, they will bounce microwaves off anything that moves, so the slightest breeze could move insulation and make it go off...... the infrared one would have to see body heat move................. ive heard people say balloons but I don't see how, its helium, its not hot, unless it moves in front of a 60W light and distorts the heat signature............ an AC vent or sun on a window would do it... not likely at 3am in an attic........................ if it really turns out to be a motion detector in your attic, and it for sure is the zone tripping, you might have squirrels in your attic, they get in there a lot....................... did you have the alarm company install the motion in your attic or was it there when you moved in....... you would of had to specifically request a motion in the attic..... so if you did, why?
@MrAnhNo9 жыл бұрын
Thanks for taking your time doing this video. This is my issue and I have no one to explain!! Thanks again
@TrongNguyen19946 жыл бұрын
Troy T Dinh hey bro. Can u explain this by vietnamese
@coloradowilderness31395 жыл бұрын
Very nice explanation. Excuse me , What is written on Your Left Hand ?
@Krakology5 жыл бұрын
that says jacob in Japanese . other arm says chase, My boys. i now also have aurebesh that says my daughters name as well
@cgarcia05248 жыл бұрын
Any chance you might know what dual EOL monitoring is?
@Krakology8 жыл бұрын
Yes. Maybe ill do a video Think of it this way Just an example Door 1 Eol 1 is 1k ohms Door 2 Eol 2 is 2k ohms Both doors closed 3k ohms resistance Door 1 open panel would read 2k ohms Door 2 open panel would only read 1k ohms Both doors open there would be 0 ohms Short would suck tho. Both zones would be in trouble . Have to meter at the panel to figure out whAt zone was actually in trouble . But no biggie
@Krakology8 жыл бұрын
Yes. Maybe ill do a video Think of it this way Just an example Door 1 Eol 1 is 1k ohms Door 2 Eol 2 is 2k ohms Both doors closed 3k ohms resistance Door 1 open panel would read 2k ohms Door 2 open panel would only read 1k ohms Both doors open there would be 0 ohms Short would suck tho. Both zones would be in trouble . Have to meter at the panel to figure out whAt zone was actually in trouble . But no biggie
@cgarcia05248 жыл бұрын
Thanks for the reply back! So with both doors being closed and showing 3k ohms resistance, I'm assuming that door 1 and door 2 are looped?
@Krakology8 жыл бұрын
+Jace Garcia 3 k was an example. Check the panel door diagram. It will tell you resistance value
@ubluis5 жыл бұрын
First time i see it can cut or open a line just only pressing the cable with a plier....can you explain that? greets
@rayanjan46664 жыл бұрын
Brilliant explanation 👍
@AliTaj56108 жыл бұрын
You are an excellent teacher...
@Brandon-qr8zz7 жыл бұрын
Very helpful and easy to understand. Thank you!
@22megaton298 жыл бұрын
What kind of resistor do I need for a commercial fire alarm zone
@Krakology8 жыл бұрын
depends on the Fire panel . read the manual or sometimes on the door of the fire panel ./
@22megaton298 жыл бұрын
Kraka069 Thanks
@graphguy11 жыл бұрын
Many sensors are wired in series on one zone, not sure how a control panel would need to be or could be programmed and wired to do resistors at each sensor for an in series closed circuit zone.
@pointyduck64227 жыл бұрын
So do you have a video how to wire eolr on fire strobe
@chrisledbetter37627 жыл бұрын
I don't think a burglar alarm system requires bell circuit supervision......... fire alarms it just jumps across your data circuit at the end of line.........for a class B circuit.............. but fire alarms you can have class A circuits and class B circuits.................... class A circuits you loop the circuit back to the panel and monitor the circuit from the panel and put your resister in the panel.... you also have to program the fire system to which type you use
@MrDumonic Жыл бұрын
Same thing with commercial cameras now a days. I’ll run the wire, install the cameras and do all the connections. But don’t ask me to get it online. Cameras are usually all plug in play. But when they want to secure it all and get it working over a local and external network, that’s up to the IT guys.
@danieldsch11 жыл бұрын
Thank you, your explanations are very clear and usefull for me, I have one question the movement detectors are wired like the smoke detector. (it has an open description). Thank you in advance.
@AxellFolley4 жыл бұрын
What about double end of line resistors
@Krakology4 жыл бұрын
double end of line is 2 different value resistors,. for easy math , lets say door is 1 ohm and motion is 4 ohm when the panel sees 5 ohm both circuits are good panel sees just the 1 Ohm motion is tripped panel sees just the 4 ohm door is open panel sees 0 ohm both open panel sees short , there is a trouble
@AxellFolley4 жыл бұрын
Kraka069 thanks can all pir sensors be wired like this just for the extra potential future trouble shooting? Also were can find info on how to read these diagrams thanks
@TomVereecke8 жыл бұрын
You can also use normal closed contacts and use 1 resistor in series with the contact and one parralel to the contact. For example if you use 3K3 resistors, in a normal non alarm state it will read 3K3, in alarm state it will read 6K6, when the conductor is cut it will read out off limit, and when it's shorted it's about 0 ohms. It's the standard way of working here. For fire detectors which are normally open we use the same method as you do.
@drumrboynoid6 жыл бұрын
Thanks for the video. I'm installing my own alarm system at my house. I'm all caught up in the thing about how people can fool the magnet switches, like the ones in your video. Can you recommend a good magnet switch for me? Much appreciated.
@philharrison88576 жыл бұрын
There are lots of comments about magnetic switches and how to fool them, or quality. Can I just say, you should only use them as a means of being able to be sure a door is closed when the alarm sets, and to be able to initiate a countdown entry timer from the final exit door. Very rarely these days to people break doors down when breaking in, far easier, and in most cases quieter, to push a panel out of a door, or go through a window in which case the contact isn't broken and the alarm is not triggered. Motion detection is really what is required, of good quality of course.
@globalmagicnation84643 жыл бұрын
@@philharrison8857 Actually most break ins are people kicking in back doors. Hardly hear about window break ins. I get my info from jobs I do for the people who have gotten broken into.”
@jamesrago21357 жыл бұрын
Thanks so much for taking the time to make this video. Very helpful and informative.
@darynweir973 жыл бұрын
Great video helped me so much!
@shaunchetty42234 жыл бұрын
Great explanation...thank you very much
@buzzyng11 жыл бұрын
really appreciate the explanation. Very thorough and the demo helped solidify. thanks
@nickm59116 жыл бұрын
So basically the door contacts and stuff are switches?
@Krakology6 жыл бұрын
umm yeah sorta
@jwj2xx411 жыл бұрын
Usually with just one resistor at the last sensor in the loop/furthest from the panel, but some systems (like the Vista series) allow for using double loops with two resistors on a single zone.
@jamesmeader2261 Жыл бұрын
Great video 👍
@craigleppan71642 жыл бұрын
Awesome man. Thanks. Nice and clear
@michaelstolman5363 жыл бұрын
Great explanation as to why the resistor should be at the end of the line but it is a pity that magnet manufacturers make allowance for these in the magnet switch.
@florida43894 жыл бұрын
Does anyone sell magnet contact switches with the resistor built in? It sounds like something that would sell.
@Krakology4 жыл бұрын
almost all panels require different value resistors. . so it wouldnt be good
@rahulmali197811 жыл бұрын
Please load more videos related to F & G system wiring.
@francoisashton71565 жыл бұрын
Thanks, such a simple concept, but very effective. Well explained.
@MiddleBencher19894 жыл бұрын
Thank you for sharing valuable information 💖
@babumon86778 жыл бұрын
thank you very much man..You are an excellent teacher... Salute..
@Viralclown7 жыл бұрын
I don't get it. You pinched it with the resistor and the voltage dropped??? So the alarm would go off?
@andrewmckay43597 жыл бұрын
He wasn't measuring voltage, he was measuring resistance.
@NinoNiemanThe1st6 жыл бұрын
It wasn't a great way to demonstrate it, but he was 'cutting' the wire to actually short it ie. the opposite of what you'd think. Because the pliers made a connection between the two wires. Not the usual way of doing this and quite counter-intuitive, but unfortunately not really explained that well, so it was a bit confusing.
@youzulf4 жыл бұрын
I understood that perfectly. Thank you.
@lelandclayton54626 жыл бұрын
Find and dandy if you wire the building and service it. If youre just prewiring it and then its up to the home owner to decide on a monitoring service they would be lost, ive been there and it sucks.
@inspiredinvesting6 жыл бұрын
Really helpful, easy to understand. Thanks for taking the time
@janr.90358 жыл бұрын
thanks for your effort sir. u such a nice guy!
@githinsmohan24297 жыл бұрын
Guys....! Can any one let me know from where can I get simplex 4007 es fire pannel software
@chrisledbetter37627 жыл бұрын
simplex is a proprietary fire panel and you have to be a dealer, they don't let anyone else get it, you would have to find someone who works directly for Simplex
@akiladilusha5 жыл бұрын
This is very helpful. thank you!
@laneburgess16433 жыл бұрын
Great video.
@kjeldguldhammerjensen49817 жыл бұрын
Great video. But how to get 4 contacts set(4 windows), in serial connection in 1 zone whit EOL. i use 4,7k2,2k now, in one contact.
@NinoNiemanThe1st6 жыл бұрын
You can do this, but you're alarm system needs to be able to handle multi-zoning (multiple sensors on the one zone) to detect which specific sensor has tripped - if that's what you're trying to achieve. If you don't care which sensor trips, just the fact one of them has tripped, you can get away with having one (or none) EOL resistors. At least one is always a good idea though, to let the system detect a fault from a trip.
@Justify49356 жыл бұрын
Basically what he's saying is by using a resistor at EOL you are supervising the entire wire and device which is the correct way of wiring a security device.
@Justify49354 жыл бұрын
@D Smith Which is the wrong way to supervise a circuit. It's the lazy way. No disrespect, but at that point, there's no reason to have a resistor at all. You're not truly supervising anything. Resistor at EOL is actually supervising the entire zone. Resistor at the panel is not supervising to EOL device. In commercial you should not being sv at panel. Reisi I don't even think SV is necessary but to each their own.
@bkoz3193 жыл бұрын
clear and concise, thank you
@tequilatyrant39923 жыл бұрын
This video is GREAT, thank you so much
@ChristopherJones24210 жыл бұрын
This isn't only about preventing wiring trouble. If I was a burglar, hell bent on getting access to a building to steal something, I could theoretically get past the alarm if I really wanted to. Perhaps the building is open during the day, I could go inside and short out some window sensors. Or at night, cut or break the glass out of a window, reach through, and short the sensor. Then, you can open the window without setting off the alarm. With the end of line resistor, if somebody were to do this, as soon as you short the wire, the alarm would go off.
@NinoNiemanThe1st6 жыл бұрын
@Christopher Jones: I think that's what they are for in most cases, but that wasn't mentioned in the video. In fact I'm not sure the video really summarised why EOL resistors exist at all, more just a non-electronics discussion of what happens when you put EOL resistors into a circuit.
@MrLibbyloulou6 жыл бұрын
You can't cover the RIGHT sensors like you used to...they go into tamper even with the alarm unset...
@philharrison88576 жыл бұрын
@@MrLibbyloulou what you mention here is anti masking, these are sensors of a high quality and grade which have this feature and are wired in line with EOL resistor wiring, an extension of it if you like.
@apeyson12 жыл бұрын
Very helpful, thanks.
@bignedu48714 жыл бұрын
Thank you very much for this video.
@kenmorton2571 Жыл бұрын
Thanks for a great video,
@loganathanreddy5596 Жыл бұрын
Want to know why a resistor is at the panel in a panic zone
@arbit3r11 жыл бұрын
Excellent explanation.
@lazbl19793 жыл бұрын
Awesome video
@dejandex18 жыл бұрын
Very helpfull, thanks. Can you tell mi how to install more then one IC senzor on one alarm zone.
@NinoNiemanThe1st6 жыл бұрын
LOL how could anyone answer this question?! Do people really expect a response when they ask such vague, non-specific questions?
@MarkCarline5 жыл бұрын
Very useful! Thanks for this!!
@crystalblueocean2 жыл бұрын
Thanks for the explanation
@rudisammel80499 жыл бұрын
Very good information. Thank you for sharing
@aksinghheikham40963 жыл бұрын
nice explanation
@cheekymonkey24008 жыл бұрын
awesome video. I'm an apprentice. you explain it so well and make it so easy. I really don't the theory work but after watching this the theory of it is not so daunting. thanks for your video
@Krakology8 жыл бұрын
your welcome
@NinoNiemanThe1st6 жыл бұрын
If you're going to do this professionally, it's a good idea to learn some (very) basic electronics. Makes understanding things like the purpose of EOL resistors really simple to understand (and things like this video would take 1 minute instead of 8). Without basic electronics, you'll be rote memorizing stuff, and will then get things wrong when you forget that stuff. Basic electronics is not too difficult - just think of water instead of electricity and each component will become clear. For example, a lot of people find voltage calculations with resistors in parallel difficult to grasp. How can putting 2 resistors allow MORE current to flow, and not less. If you think 'water', it all just makes sense - even capacitors and transistors!
@marioabreu86478 жыл бұрын
buenas noches Seth McCaslin probaste con un tecte a ver si te miden los bornes 4 y 5 si es una honey well adenco tube un problema similar y era una resistencia..... pero diras luego a ver si te puedo ayudar si nos que sabes amas que yo.................
@TCJC12138 жыл бұрын
very nice video now I can let my tech know why this is importent
@starlite5284 жыл бұрын
The best reason for putting the resistor at the device is to monitor the wire for tampering while the alarm system is armed.
@KevinWorrell6 жыл бұрын
I think you meant to place the resistor across the normally open switch in the beginning, not series with the normally open switch. You placed it correctly with the smoke detector.
@Krakology6 жыл бұрын
what N.O. switch? i think maybe your mistaken
@mariusbronikovskis815111 жыл бұрын
Thanks, this was really useful!
@rythem1711 жыл бұрын
commercial we always use at device also unless doing some-kinda special bypass switch or something
@NinoNiemanThe1st6 жыл бұрын
Good demo with the multimeter, but the explanation was kind of all over the place with the major point not made clearly. If you understand high school physics, easiest way to thing about EOL resistors is: they allow an alarm system to detect THREE states via a voltage read instead of two. The states are: 1) Open circuit - no current/voltage, 2) Normal close, with a reduced voltage due to the resistor and 3) Abnormal close, ie. a full short without the resistor being in-line. Of course, your alarm system needs to be able to measure these 3 states, but almost all have EOL resistor detection to do so.
@sleewok9 жыл бұрын
Excellent help. Thanks!
@Krakology9 жыл бұрын
+sleewok thanks for watching
@mgruzz9 жыл бұрын
how about wireless devices?
@dales0953 жыл бұрын
On an open Circuit Loop the Resistor should be in paralllel to the device at the end of the line. It won't do anything in series if the wire is cut.
@joshclarke72799 жыл бұрын
Great clip. Thanks mate.
@ajitmacwan49746 жыл бұрын
Very nice video
@TeamTryHardBmx9 жыл бұрын
It's really good to know this after all this time of wondering. But how come some times devices won't communicate properly without an EOL resistor? And how come some times you put them at both ends (start of line if that's such a thing, and end of line)
@NinoNiemanThe1st6 жыл бұрын
It's not common, but the main reason for EOL resistors at both ends (if that's the way the system is designed) is not to make them add up to 2K (if that's what the circuit requires). It's to allow the alarm system to differentiate 4 states - reflecting the 4 voltages you get when one, or both resistors are shorted out of the circuit. Some high-security systems do this to try and detect burglars shorting the circuit - they can short out one, but usually not both of the resistors given they are in different locations, allowing the alarm system to pick up any interference with the circuit.
@faiznordin73398 жыл бұрын
thnks for the lesson bro 👍😁
@danieldsch11 жыл бұрын
Ok, I will wire it in series and see what happen. Thank you.
@abdelhamidbensadoun61026 жыл бұрын
This is helpful. thank you!
@jerrykr0111 жыл бұрын
Thank you for spending the time to make this. Clarified things for me alot.
@RadioReprised8 жыл бұрын
Am I the last guy left who still services Morse MDC-16's!.....one of the best systems ever. And then there's the Optex-Morse Genysis POS!
@Krakology8 жыл бұрын
RadioReprised yup
@RadioReprised8 жыл бұрын
LOL!...I have about 300 of them monitored and like a Radionics 41 or 61..........they just won't DIE!