brill this i have been racking my brain but now you av took the pressure off thanks
@GSHElectrical6 ай бұрын
Thanks for watching 👍🏻
@julespepper66912 жыл бұрын
Cheers thanks 😊 good nice and simple as usual
@GSHElectrical2 жыл бұрын
Thanks 👍🏻
@RossHbn Жыл бұрын
Excellent explanation, cheers.
@mineraloasis95003 жыл бұрын
As always. Nicely explained. Thanks
@GSHElectrical3 жыл бұрын
Thanks 👍🏻
@martinward5012 Жыл бұрын
Can you use 3 way wire instead of 4 way wire?
@Johnnyboy-kt8dc10 ай бұрын
Thank you Gary - clear as always. The downlights I am planning to run do not have an earth terminal so should I still run a CPC between them and if so what would I do with it at each downlight. Also what is the maximum number of 5.5W downlights you would recommend on each circuit? Many thanks.
@GSHElectrical10 ай бұрын
How many lights can you connect to a light switch? kzbin.info/www/bejne/Y4q8YaVsr6iSg5o
@daphnetilling6034 Жыл бұрын
This has finally shown me what a bulls up I did at re-wiring my hall and bathroom light. Got 2 gang going to hall and bathroom with the hall one connected to a 1 gang switch, at least now I can go back and wire it properly. I do have a question though. Is there a way to wire it so that the light that is connected to the two switches can make the 2 gang one into a 1 gang switch so there is only one switch controlling the hall light? Like maybe using wago connectors to disconnect one of the 2 gang switches
@seandempsey73512 жыл бұрын
If I remember correctly that’s the non conventional method I was tort to make the connections at the ceiling rose ie the conventional method?, but what ether way you do it it works . Great video clear and informative instructions. Gaz why don’t anyone make the connections in the ceiling rose any more with two way switch cables to each switch? I haven’t seen it done that way for years. Great video as always Gaz❤️👍👍👍
@blueboy4life2 жыл бұрын
3 plate feed at the light. 2 plate feed at the switch was how i remembered
@chaddonnelly98725 ай бұрын
Great video! Question: if you are doing a x2 2 gang switches where both are 2 way switches + the power cable running to the first 2 gang box rather than to the light fixtures first.. am I right in assuming you'd have 1 power cable entering the first box, as well as 2 cables to the 2 fixtures, and 2 cables to the other 2 gang box. So 5 cables in the first box? and if that's correct, does the main power cable to the first box also stay at 1.5mm, same as the switches and lights, or is it better to upgrade to a 2.5 since its feeding 2 light circuits?
@ColandJen-bb2qn Жыл бұрын
Hello mate this is really helpful, I wondered if I could as you a quick question! Moved into a new house, changed a 2 gang switch which controls 4 lights - 2 on the landing and 2 in the hall. When you turn the landing ones on, you can't turn it off upstairs! I assume I've just got the wrong wire in the wrong port?
@pcg1276 Жыл бұрын
Hello.why did you remove the line from the common to L2,when the light would have worked just the same.
@basilalhilli46272 жыл бұрын
How do add a new light under stairs when you have only a two way switch available is it possible
@user-nn4ny8rw9g2 жыл бұрын
Hi Garry great video as always 👍 Can you please do a video on this same scenario on a 2 plate method please would really help me and others out as not much information is out there on complex 2 plate wiring when adding more gangs or intermediate switches Thank you 👍😊
@GSHElectrical2 жыл бұрын
Loads of 2 plate method wiring diagrams in this playlist Wiring Diagrams for Lighting and Motor Circuits kzbin.info/aero/PL2Ea5r9gxUUfm4SACOSOZigCeSxxC5xaO
@GSHElectrical2 жыл бұрын
And this one 👍🏻 Taking the Feed (Supply) to the Light Switch the 2 Plate Method kzbin.info/aero/PL2Ea5r9gxUUevU9gv8lizD53aYvwiJ5qr
@shahzadeh12 жыл бұрын
Where is the next video. The one that shows the light up stairs and downstairs on two different circuits with a 2 way switch?
@GSHElectrical2 жыл бұрын
In this playlist 👇🏻 Wiring Diagrams for Lighting and Motor Circuits kzbin.info/aero/PL2Ea5r9gxUUfm4SACOSOZigCeSxxC5xaO
@rukshaz12 жыл бұрын
Excellent
@GSHElectrical2 жыл бұрын
Thanks 👍🏻
@usmanmohammad9759 Жыл бұрын
Amazing
@GSHElectrical Жыл бұрын
Thanks
@herrtomas67292 жыл бұрын
Excellent thanks, but your subtitles could be better positioned....
@GSHElectrical2 жыл бұрын
Hi i have just checked the subtitles and they look ok to me is it possible you could check them again for me... massive thanks Gaz
@herrtomas67292 жыл бұрын
Subtitles cover lower part of diagram on my Chrome browser, under Windows10; not in full screen mode
@sylvianorah1367 Жыл бұрын
This was not clear and confusing . Why not start with new drawings?