AC Fan Outside Not Working - How To Check It

  Рет қаралды 492,578

Word of Advice TV

Word of Advice TV

Күн бұрын

Пікірлер: 411
@ulikewatuc1ulikewatuc170
@ulikewatuc1ulikewatuc170 4 жыл бұрын
Thank you for the informative video, I tested the fan and my fan was good, come to find out I had a bad capacitor. Thank you once again👍
@Explore531
@Explore531 Жыл бұрын
I have a question for you why is my Central air A/C keeps turning on and off every few secs on ones having that problems only me thankyou
@markdunckel7236
@markdunckel7236 2 жыл бұрын
You are the best. A/c stopped working in the middle of the summer. Had a estimate to fix it $700.00. Luckily found your KZbin. Bought a capacitor for 8 bucks and now I’m chillin again. Thanks.
@jacksontsuma6684
@jacksontsuma6684 Жыл бұрын
I'm the HVAC technician and I can say this buddy is good enough in teaching. I always like to check your vedios. Big up.
@bparker86
@bparker86 3 ай бұрын
Yeeaaa ima go ahead and call major BS here
@user-ll9uw2ex8y
@user-ll9uw2ex8y 3 жыл бұрын
You know what's wonderful about people is when they share their knowledge. I appreciate you for sharing your knowledge with us. We fixed our AC! YAY!
@robertfulton4829
@robertfulton4829 Жыл бұрын
You just saved me about $500. The ohms were good but the motor is 17 years old and I'm told it has seized up. Capacitor was just replaced. Amazon and KZbin to the rescue!
@KittyNoNo
@KittyNoNo Жыл бұрын
How did you deduce that the fan motor had seized up? Does it not spin freely by hand? I'm curious because I think I'm in the same situation you are. After 18 years, my condenser fan stopped working. All these guides say to check the ohms, and if the readings are correct, then the fan is fine. My ohms were perfect. the fan spins freely. I took the fan motor apart to check for damage/corrosion, and it looks almost new. However, it will not come on. The compressor comes on, then shuts down due to the fan not spinning. I have all correct voltage at all connections. New capacitor. So, it has to be a bad motor, right??? lol! I appreciate these videos, and I know the content creators try to keep their tutorials as basic as possible - but I haven't heard "If the fan's ohm readings are correct, then the fan is most likely good. However, it is possible that other issues with the motor could prevent it from working." I'm just going to order a new motor, and return it if it doesn't work. I'd really like to hear how your repair goes! Good luck!
@robertfulton4829
@robertfulton4829 Жыл бұрын
@@KittyNoNo our AC guy mentioned that the fan motor may become noisy i.e like a bad bearing. I didn't notice anything specifically, since we have 2 units outside and can't really hear them inside. I figured there aren't many other things that could be bad, and the capacitor was replaced the day before. I didn't take the motor apart to look for corrosion, but it seemed like a reasonable cause of failure. I didn't want to pay his fee to come back out and check it/replace the motor (which worked when he left the day before), so I found this video.
@robertfulton4829
@robertfulton4829 Жыл бұрын
Mild panic, the new motor came in, and it had 2 additional wires connected in a loop, which changed the black wire to blue. In between looked like a lighting ballast. White ceramic. No where to put it, and definitely would get in the way of the fan. We zip tied it to the grate. Hope it works out! We plugged everything in, confirmed voltage. The compressor started but not the fan. We pushed the blade with a stick a little and it took off. We have cold air! We hope the repairs hold up. Thanks again!
@KittyNoNo
@KittyNoNo Жыл бұрын
@@robertfulton4829 Thank you very much for taking the time to reply. I see that you've installed the new motor, and that it solved your problem. Good to hear! Hopefully, push -starting the fan was a one-time thing and it will start automatically going forward LOL I''m looking forward to cold air too! Thanks again!
@robertfulton4829
@robertfulton4829 Жыл бұрын
@@KittyNoNo Well now we have a new issue. Cool air, but the temps arent dropping. I will have to investigate more today.
@MrCeora
@MrCeora 2 жыл бұрын
No offense, but for a young guy, you really have your stuff together. I really appreciate how you put emphasis on safety precautions. I took my grandson to a trade school open house, and as we walked out of the electrician display of graduates, there was a separate display of one particular individual. I asked what was the reason for his distinction. We were told that on the second week of his first job he had electrocuted himself by not following one of the basic rules that were taught at the class. You never know if your emphasis on safety and what is routine practice for you, could reach the right ears and save a life.
@MrCeora
@MrCeora Жыл бұрын
@Blank Man No offense that I first assumed because of his age he wouldn't be as cautious and safe as he is. An assumption that I apologize for having is what I meant.
@MrCeora
@MrCeora Жыл бұрын
@Blank Man The young man who electrocuted himself was relatively young and in his 30's, probably like you. Maybe subconsciously that was In the back of my mind. Who knows.
@akib2926
@akib2926 Жыл бұрын
Our A/C unit has making buzzing sound all the sudden I replaced entire A/C system and unit 2years ago. It was about $6000.😢 I am so upset because #1 insist so freaking hot and #2 only 2years?? I am having issues with brand new A/c unit 🤬I called the company 3times they don't even call me back.
@whitleyca
@whitleyca Ай бұрын
You are too good! Can't thank you enough for putting this info out there. Our fan quit working a while back. Your videos pointed me through the troubleshooting effort: capacitor tested ok and was not physically deformed. Then found quite a few dead ants in the contactor. Cleaned it out and the fan turned on as it should. Fast forward a few weeks and the fan has quit again. Will be testing it as you have shown here. Very much appreciated!
@iamsomeone7578
@iamsomeone7578 3 жыл бұрын
Hi, Sir, you are a great mentor. I have some questions: If the fan motor stops running but the compressor is still running, what will happen? In this situation, why is the circuit breaker tripped? and how does the compressor's thermal protection mechanism protect the compressor? Thank you.
@fortunateson6070
@fortunateson6070 5 жыл бұрын
I subbed to your channel last year when I became a homeowner, this video fixed my A/C this morning after it broke down last night and I was still able to go to work. My capacitor wasn't shorting to ground, but it was almost too hot to touch when I removed it. I was able to push start the fan last night and set the temp down to 65 so it would run all night and we got some sleep before the repair.
@attimsaham
@attimsaham 3 жыл бұрын
hi thanks a lot for what U`ve done my motor is good but it runs for a seond only and goes off immediately I`ve changed capacitors contactor but no change indoor unit works normal but not cold what could cost that? indoor or outdoor unit ?
@KwiK808
@KwiK808 Жыл бұрын
Really appreciate all your videos. Very consice. My mother's unit was frooze up, so I helped her get it running again. But the tech she had apparently called came over. He simply added more refrigerate and left. Only to wake-up to a frozen unit again. Now the blower motor is not even kicking on. Hopefully it does not need replaced. God Bless & God Speed Brother.👍🏻
@orbitsun
@orbitsun 2 жыл бұрын
Jay, thanks to your videos I was able to diagnose my ac problems and fix them myself. Much appreciated.
@timhoskins9808
@timhoskins9808 2 жыл бұрын
Thanks for SAFETY FIRST cautions, so very important in everything we do, especially when we are around electricity !! A big thank you for the detailed video on how to check the fan motor Ohms resistance. At first I changed out the Start Capacitor and motor started, but would not keep running. Then I followed your instructions for checking the motor and decided it should be replaced because of the Ohms resistance measurements and what I felt were bad bearings (way to much end play). New motor in and running great.
@isa540
@isa540 Жыл бұрын
Such a precise and easy to understand explanation. Thank you bro.
@nps2068
@nps2068 3 жыл бұрын
Thanks for the video! My compressor turns on but my outside fan doesn't until I give it a push. Is that a symptom of something specific or should I just go ahead and check the ohmage of the fan motor? Thanks again!
@nps2068
@nps2068 3 жыл бұрын
I changed out the capacitor after reading online that several others had my exact symptoms. Turns out that was the issue and my AC is fixed! I paid $14 for a new capacitor and $11.63 for shipping compared to $115/hr just to get the problem diagnosed by a professional. Thank you World of Advice TV for the great content, you saved me some serious cheddar!
@95ffd
@95ffd 3 жыл бұрын
Great video. My ac stopped yesterday. Replaced the capacitor today. The fan didn't start, but I nudged it and it started, and cooled for quite some time, then stopped. The motor was very hot to the touch. Is that a good indicator that the motor is bad? I'm hoping I didn't burn up the compressor with it running without the fan. Thank you for your help and all the great info
@jawojnicki
@jawojnicki 3 жыл бұрын
Hi Jay. My fan does not turn on by itself, but when the compressor is running and I start the fan spinning with a screwdriver it will keep spinning by the motors power. Is this pretty much a slam-dunk capacitor diagnosis? If not, what could be the issue? There is no abnormal heat nor sound coming from the fan motor when it is running
@seanchao6218
@seanchao6218 5 ай бұрын
Great video, clear and simple, good job, thanks. If the fan motor goes on and off when the compressor is running, is this also a sign of bad fan motor? or there might be other issues? Thanks
@housepraise9369
@housepraise9369 4 ай бұрын
Hrlo, Mr. Advice Could you please kindly advice me about this.. thank you 🙏👍 I Just replaced capacitor but the fan not spinning . ( i didnt check the fan before replaced, ouch) Inside the house ac is on but not cool. could you please tell me what to expect and to look at, ? Does it's needs freon? Connector or motor fan needs to fix, replaced? How much about price range of a motor fan? Thank you.🙏🙏🙏
@samueljones6255
@samueljones6255 Жыл бұрын
Good work young man thanks for the info keep up these helpful videos they are a treasure to people on a budget and cant afford a service call. Thanks
@gavinmcgaha1992
@gavinmcgaha1992 Жыл бұрын
Thank you for your time and explaining the process. Your are a great teacher.
@petermartin5637
@petermartin5637 Жыл бұрын
Very clear step by step directions. Thanks for the help!
@minoX6
@minoX6 11 ай бұрын
Thank you. I love those AC units you have there in the US. I wish we had them here in the UK
@JF0913
@JF0913 6 жыл бұрын
Great advice. Thanks very much. You're an awesome teacher.
@charlesplantjr2814
@charlesplantjr2814 5 ай бұрын
Hey Jay I would like to say thank you for your video. The knowledge that I get from you is the bomb. The simple repairs I can do myself just because of you. Keep putting the videos out and may you be blessed
@wpzhang
@wpzhang 4 жыл бұрын
Your video is always so good! Thank you...I have a spare fan motor from an old working condenser. I know it runs but the ohms are not adding up as supposed to: 31/82/95. Dose it mean it is going to die soon or something else? Thanks again.
@STAR-X-SERVICE
@STAR-X-SERVICE 2 жыл бұрын
This video very helpful I just following his diagnosis step and tracking by multimeter A/C out box one of fuse was gone so replaced new one and A/C working great. Save lot of money and times. Thanks again an appreciated this video.!!! ;)
@davidlektzian7748
@davidlektzian7748 5 ай бұрын
Thank you for this helpful video and all of your other great videos. In my situation, the fan was not spinning and I used a stick to get it started. That worked temporarily. Then it stopped working and I discovered the main 240 volt fuses outside the house were blown. I replaced the capacitor and the contactor and coil. I replaced the fuses and they instantly blew. I checked the motor today and got resistances of 24.7, 57.8, and 76.4. They are a lot lower than you got in the video, but they roughly add up, so I'm thinking the fan motor is probably good (the motor is a 208/230 1/4 hp unit). The AC unit is a PH13NR048 manufactured in 2011. Any ideas on the next step? Is it time to call in a repair tech?
@mikereedy51
@mikereedy51 3 жыл бұрын
Great video my air compression runs but fan don't run is it safe to run just had installed August 3
@earlclay7348
@earlclay7348 5 жыл бұрын
I have an A/C system that is about 8 years old and the outside unit stopped coming on this past Sunday. I watched all of your videos, thank you BTW, but I can't seem to find the problem. I like to at least try to fix things myself but I don't know if I just wasted a day of no AC in the heat here in AZ. I tested my Compressor, I have continuity for all 3 plug ins, none of them are shorted out. My fan motor read 54.6, 35.8 and 90.3, so that looks good. My capacitor is a 45/5 Dual and read 47 and 5. I'm not sure what else I can do to check what's going on. I can press the little plastic button and the whole system turns on, but it does seem to be running a little slow. Oh, I also have 240 volts going to the unit. What else could be wrong ? Thanks for the help
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
Hi Earl! Sorry to hear that the AC quitting on you. Have you checked voltages in and out of the contactor? So 240v goes into one side and 240v should come out the other side when the little plunger gets pulled in. Also, you mentioned that you pressed on it and it came on. Does that mean the contactor plunger does not pull in on it's own? Does the coil get 24v when there is a call for cooling? If the contactor is not pulling in on its own, then I would start by figuring that out first. I have a video on 10 reasons why a contactor may not pull in if you need it.
@jamesrockford5145
@jamesrockford5145 6 жыл бұрын
Simple and to the point. If you checked continuity between the individual wires and you didn't hear the beep, that would also indicate bad motor?
@WordofAdviceTV
@WordofAdviceTV 6 жыл бұрын
Yes. If there is no continuity, then the winding is open and the motor needs to be replaced. Although once in a while my meter plays tricks on me.. (perhaps it was weak batteries) I check for continuity and it doesn't beep. But then I check resistance and there is resistance..
@jeffreyMagnum460
@jeffreyMagnum460 5 жыл бұрын
Thanks for your video, my capacitor was bulging on top so I replaced it and now my air conditioner is working. Thanks again.
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
That's what we like to hear! Thank you for commenting!
@stevebolaris1076
@stevebolaris1076 4 жыл бұрын
Thanks! Through your videos I have been able to isolate the fan non operation as the issue. Next up for me is to use what I learned here to check the resistance with my meter to verify that it is the fan motor that is in fact bad before spending perhaps hundreds on a new motor. The only other thing that I am unable to check is the r-22 pressure as I do not have the proper gauges for that.
@ranger178
@ranger178 25 күн бұрын
how much force should the motor take to turn when power is off? I think my fans bearings are worn out being 26 years old it seemed a bit hard to turn i spun it a bit and it loosened up some then worked when i manually turned on contactor
@ThanhVanNguyen-v6h
@ThanhVanNguyen-v6h 3 ай бұрын
Thank yoi for sharing video. I have a question when i check my ac fan motor with multimeter: the brown and black is 52.7, the purple and black or purple and brown are OL. Does it mean my fan motor is bad or just the purple wire goes bad? Thank you
@jhug1987
@jhug1987 3 ай бұрын
Thanks for the guide, but quick question. My A/C is out - condenser comes on but fan does not. I've already changed the capacitor, which led me to check the fan motor with this video. However, my ohms are adding up. I got 38, 52, and 88. What's my next move?
@robertcadena8517
@robertcadena8517 4 жыл бұрын
Thank,your videos are very precise and informative. I verified that my compressor is working and I've installed a new capacitor. I then checked the three wire"s you've shown on my condenser fan and get an OL reading from all of the wires. Does this mean that the fan is bad?
@FireHorse11291966
@FireHorse11291966 3 жыл бұрын
It's great that you get right to the point with all of your videos. Subscribed 👍
@justincuevas5226
@justincuevas5226 5 жыл бұрын
Its crazy how much more im learning doing both install and service, I get to learn both sides and I have a better understanding of the whole system. Your vides have helped me out a lot, keep it up!
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
Thank you! Glad to hear the videos are helpful. Good luck in your career!
@williamvann4305
@williamvann4305 2 жыл бұрын
Jay, thanks for your informative videos. I have an old Trane system which is still working pretty well, but the condensor fan is shutting off intermittently. I checked the resistances between the wires as you advise in this video and the sum of the 2 equal the 3rd indicating the motor is good. Is it shutting off due to internal heat protection? Would a new one do the same thing? The condensor unit is in the direct sun in the afternoon, so it gets pretty hot there when the outside temperature gets to 90 degrees or above.
@fortyampbreakerr6234
@fortyampbreakerr6234 Жыл бұрын
you ever figure this out?
@hoonyur5973
@hoonyur5973 4 жыл бұрын
I am not getting any continuity/resistance at an fan wire combination. Also, no continuity with any fan wire to ground. I have confirmed i am getting 240v to the contactor (brand new) and my capacitor specs out at the rated farad rating and not bulging at the top(replaced last summer). The fan spins freely so it’s not seized but it also won’t start when tapped with a screwdriver. I also noticed that the sealed bearing on the fan seems to be either leaking/lubed prior. As a last note, the fan motor gets hot but doesn’t spin when ac is turned on. I am really thinking the condenser fan is shot but wanted to see that if given these symptoms, has that been your experience as well..?
@JF0913
@JF0913 6 жыл бұрын
Yes could not get to the point. This unit unfortunately is in direct sunlight most of the day, so I expect the parts on the unit to not last as long as they should. So oddly enough it eventually got to the 71 degrees a while ago. Do you think that maybe it could be that the compressor is starting to act up. The unit is 9 years old. The suction line is cool and sweats as you show in your video.
@Jlarroyo7
@Jlarroyo7 5 ай бұрын
Hey Jay! I swapped my capacitor out since my readings were 28/3 on a 35/3 capacitor. I also checked the fan wires and got 159 , 122 & 37 between the wires. The fan still won’t start until I give it a push a few times. Do you think the condenser fan motor can still be bad even though readings add up? Should the fan wire lower readings be more even?
@wpzhang
@wpzhang 5 жыл бұрын
Thanks for your great videos! If the resistances are good, what other reasons can a fan motor go bad?
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
A motor can fail electrically or mechanically. A meter won't help with a mechanical problem. A seized motor for example, where the bearing is shot. If you spin it by hand and it spins hard instead of freely, then the motor is bad. You can try oiling it, that might free it up. Usually the motor would get replaced though.
@wpzhang
@wpzhang 5 жыл бұрын
@@WordofAdviceTV Great! Thank you for the best advise as always.
@tsegucherenet9413
@tsegucherenet9413 5 жыл бұрын
I like how simply explain the things! thank you
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
I try to keep it non-technical ;) Thanks for watching and commenting!
@mariobryant8803
@mariobryant8803 4 жыл бұрын
Brilliant information- resistance reading
@Johnny-kk4yr
@Johnny-kk4yr 3 жыл бұрын
Can a contractor cause a compressor to run and fan motor to not work ? I know it sounds like a capacitor but capacitor is fine and motor was replaced recently
@suspectdown5133
@suspectdown5133 5 ай бұрын
My fan is buzzing and starts with a push...is that a starter or cap problem ? or just within the fan motor itself ? Thank you.
@pondersomewhat
@pondersomewhat Жыл бұрын
Thanks for your videos! I've watched pretty much all of them to do with HVAC. My heat pump unit has started tripping the in-house circuit breaker instantly every time it starts up. If I disconnect the fan leads from the defrost control board so that the fan is out of the circuit, the compressor starts up just fine and the breaker doesn't trip. I tested the capacitor and it is good. I ohmed out the motor and it appears fine. I swapped in a replacement motor anyway and the same short circuit occurs. Does this mean the short is happening in the defrost board? The defrost board controls the main contactor for the compressor and a relay for the fan, but I don't see any damage to the board. It's a Trane CNT02940 defrost board, which I think is supposed drive the fan at 2 speeds. Should I be seeing 240V across the fan motor contacts when the compressor is running, because it looks more like 9 to 12 V.
@tex24
@tex24 3 жыл бұрын
Great video! Question... What's the black looking capacitor under the capacitor that is the focus of this video? Is that also a capacitor? Doesn't it need troubleshooting?
@markverre1
@markverre1 6 жыл бұрын
Ordered a replacement capacitor to match the existing. 70/7.5 MFD 370V Round Should my existing fan still not run (825 rpm ROT Cap 7.50/370 1.40A) can I replace it with a 6 month old motor from another unit? (1075 rpm ROT 5/370 1.8A) ? If so, can I still use the 70/7.5 capacitor that I just ordered, or must I downsize? What size should it be? The idea was to save money by using a motor I have versus spending $200 for a replacement 825 rpm unit. So grateful for your videos and your advice.
@WordofAdviceTV
@WordofAdviceTV 6 жыл бұрын
Well.. Generally that is frowned upon in the HVAC field. You will increase the RPM by 250. Keep in mind that the fan blade is designed for 825 RPM. Which means the noise that the unit makes will likely increase. (sometimes dramatically from all the extra vibration) It would also affect the efficiency and operating pressures of the unit. The refrigerant side of things may be thrown off a bit which can result in the unit not keeping up on hotter days. That being said... Yes, it can be done and people do replace motors with higher RPM replacements. Maybe you will get lucky and yours will work just fine. Or it may start to occasionally overheat and stop. Also, you could probably just get a different 5 MFD capacitor for the fan motor and use the 70 for the compressor. But with capacitors, going from a 5 to a 7.5 is a big difference and not recommended. I hope that helps! To summarize, I would not recommend it but it can be done and it probably will work. We do that in the field sometimes but only temporarily until we can get the right size.
@markverre1
@markverre1 6 жыл бұрын
A million thanks for your complete and rapid response. I should have stated that I have the complete 1075 rpm motor, fan blade and grill and that I live in the desert of Southern California. 120 degrees here this week. My unit's brown wire was connected to FAN, Blue to HERM and Yellow to C. HOPEFULLY, the dual capacitor I have on order will solve my issue. Just in case... to utilize a separate 5 MFD and the 70 for just the compressor, I would be truly grateful for your wiring directions, should you find the time to reply. Might you have a recommended replacement and source for the existing GE Commercial Motors by Regal Beloit 5KCP39LF 825 RPM motor? With sincere thanks and deepest appreciation.
@WordofAdviceTV
@WordofAdviceTV 6 жыл бұрын
Oh boy, 120 degrees sounds mighty hot! Well if it comes with the fan blade, then that does improve the odds! It would be worth a try I suppose. But I agree with you! Hopefully the capacitor will fix it for you! That would be best. The wiring for a separate 5 MFD capacitor is pretty easy. If the new motor has 2 brown capacitor wires, then those 2 wires would simply both go to the new capacitor instead of the dual capacitor. If there is only one wire from the fan that hooks up to the dual capacitor, then you would put that wire on one side of the separate 5 uF capacitor and then for the other side you would put in a jumper wire going to the common on the dual cap. I hope that makes sense.. Unfortunately I am having troubles trying to look up the motor that you mentioned.. 5KCP39LF is that the part number on the motor itself? I think being that it is a commercial motor it will be harder to find the OEM since they mostly only sell to contractors. The most important part is that the RPM, HP, and voltage line up. The length of the shaft sometimes too. If the screw holes don't line up, you can always drill new ones.
@markverre1
@markverre1 6 жыл бұрын
SUCCESS ! You are a GENIUS. A million thanks for sharing such valuable information with us all on KZbin. The new capacitor arrived, and as you predicted, condenser fan started right up ! My worry for fan replacement was for naught. But it feels great to be able to enhance my knowledge. Thank you, kind Sir, for sharing your skills with me. I remain truly grateful ! P.S. I bought a voltage pen to hopefully prevent any shocks. Again, I thank you.
@BlackLight_VA
@BlackLight_VA 5 ай бұрын
What's up Jay? I have a Trane split system heat pump and it isn't cooling like it should. I feel confident that it's the fan because it doesn't always come on when the compressor does and seems to cut off early and seize up but the resistance numbers added up exactly (41, 70 and 111) and I just changed the capacitor. Is it possible that the problem is still the fan motor or should I look elsewhere?
@minhkhauo1313
@minhkhauo1313 3 жыл бұрын
Hi how are u ? I or already change capacitor and contactor , The motor and compressor still doesn’t work。when you put the contactor down is work. Can you tell me what happened ? Thank you
@patmiller2415
@patmiller2415 2 жыл бұрын
What type of meter do you use on the HVAC? So I can purchase correctly. I guess I can not use the regular "Multi-meter".
@WordofAdviceTV
@WordofAdviceTV 2 жыл бұрын
Hi Pat! Here is a video on how to use the meter in the video and there is an Amazon link to it in the description: kzbin.info/www/bejne/sKOXgKpnf7lsoLc
@gloriahenriquez6086
@gloriahenriquez6086 3 жыл бұрын
Should the fan be working at all the time ?? Or is a cycle of on and off ?
@milesbrown2
@milesbrown2 5 жыл бұрын
Jay, so my capacitor is kind of new. I replaced it myself a while ago and it’s been working fine. And it’s not bulged up and I check continuity with my primitive meter. So I believe the capacitor is ok. I have continuity with my fan motor wires and the olms #’s add up. So theoretically the motor should be good, but when I try to spin the fan blade, it doesn’t spin freely. That leads me to believe that the bearings are seized or in need or lubricant. Should I bother disassembling the motor and try to lubricate the bearings, or just get a new motor? What would you do? Thanks. Mike
@moid1971
@moid1971 4 жыл бұрын
What was the solution?
@milesbrown2
@milesbrown2 4 жыл бұрын
Moid M I ended up buying a new motor and change it out. Working perfectly now.
@moid1971
@moid1971 4 жыл бұрын
@@milesbrown2Thanks for your response. i had the same problem, and its resolved with the new motor. The blades started rotating after i removed the motor from AC unit, and hammered a bit to remove fan. But i decided to change motor anyways as this is the second year with same problem.
@milesbrown2
@milesbrown2 4 жыл бұрын
Moid M well done. New = Better😊
@anitaserbanescu1948
@anitaserbanescu1948 4 жыл бұрын
You are awesome and wonderful explanations and details. I do have a question thought. I have already replaced my motor fan and capacitor, but my fan is still not working. One of my fuse from inside the house, the 24v. keeps shorting. Can you tell what the problem might be. Thanks a lot. Keep up the good work!!
@Theincompetenthandyman
@Theincompetenthandyman 4 ай бұрын
I tested my motor according to your instructions, I got readings of 25.8, 24.2 and 49.7, how do I know of this is enough? Everything I have read said ohms should be between 80 to 120, this is on a lennox ml14xp1 4 ton unit
@crinerda
@crinerda 2 жыл бұрын
I really appreciate you making these videos. You have helped me a lot! Thank you
@losmoore3358
@losmoore3358 7 ай бұрын
U refreshed my HVAC memory. My condensor fan not running. I replaced both capacitors. Still not running, but I hear humming sound.
@JF0913
@JF0913 6 жыл бұрын
Awesome job. Can you check the air handler blower motor the same way?
@WordofAdviceTV
@WordofAdviceTV 6 жыл бұрын
Thanks! Yes you can, but the air handler blower motor usually has multiple speeds so checking one of those follows the same concept but slightly differently. (a reading for each speed)
@grantyentis5507
@grantyentis5507 7 ай бұрын
How long are those fan motors supposed to last? I had the motor replaced several years ago and the capacitor more recently. I also did a complete clean out of the condenser coils and the thing worked great until we had a bad rain storm, the only the compressor would run but not the condenser fan. I dont have all those fancy electronic testers like you so i just tapped various components with a stick and prayed to the appropriate entities but my problem didnt improve. I also wonder if that relay could be at fault . I used the stick on that along with some prayer and it also turned on the compressor with no fan. This problem began last august of 23. I still pray over it from time to time but to no avail. Im getting nervous with summer looming closer
@michaelsmith1124
@michaelsmith1124 2 жыл бұрын
What would cause a fan motor to overheat? I've replaced the capacitor with exact relpacement then when powering on, the old fan was noisy, probably the root cause of the capacitor going out on the fan side. Then I installed a new fan motor (exact replacement Fasco D934). AC would run for about 4 minutes before the fan shut off. Compressor was still running. The fan motor was extremely hot. Could I have a bad motor? Wiring problem? I'm running out of ideas. I really like your video's. Thank you, Mike of Chicago
@jennyleung6537
@jennyleung6537 5 жыл бұрын
sir, i saw you pull wires from the capacitor, do i need to discharge it first before i pull? thank you so much.
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
Yes. Verify that the power is off, discharge the capacitor, and only then pull off the wires.
@ramjaane6856
@ramjaane6856 3 ай бұрын
Hi jay For my AC it was short cycling and now the fan is completely off, checked both caps they are good , found that when I press the contractor both compressor and fan starts working so should it be the contactor might be bad.?
@danlee4809
@danlee4809 2 жыл бұрын
Hi Jay, thanks for the great video. Here is my situation. My furnace motor is only blowing warm air and the AC unit (both the compressor and the fun) doesn't turn on. I opened up the AC panel and carefully pressed the contractor with a screw driver and the compressor comes on, but NOT the fan. I did purchased new replacement capacitors (both the start and run) and plan to replace them anyways. But what I am concerned is the fan motor is bad. When I used a stick to push the fan, it turns freely with no resistance. With this, I think I have 240V coming in because the compressor was running. Should I focus on testing the fan motor at this time? Why do you think the contractor is not pulling in when the thermostat is turned on? Maybe I am having more than one issue at the same time? Thanks for the advice?
@danlee4809
@danlee4809 2 жыл бұрын
It was just the run capacitor. Thanks a lot for the videos.
@hdman97
@hdman97 6 жыл бұрын
Very nice. What's the brand of that meter? I like the fact that you can also check current with it.
@WordofAdviceTV
@WordofAdviceTV 6 жыл бұрын
I like that meter, so far it is the best one I've used. (My first meter was 300 bucks) But anyway, here it is on Amazon: UEI Multi Meter: amzn.to/2MbSHC2
@DD69corvette
@DD69corvette 4 ай бұрын
Hi, I replaced the capacitor and the thermostat. Motor will kick on and run for a few minutes than stops. I havnt checked the motor with a meter yet. But it's starting to point towards the motor. Any advice?
@airgunner0335
@airgunner0335 3 ай бұрын
I just checked my fan motor and no ohms reading so I pulled the fan and put a free standing 18 inch turbo turbo where the fan was until I can getting another fan and it's 110 today central California. To answer your question yes if the fan stops then it going out
@yurirozenvayn3087
@yurirozenvayn3087 2 жыл бұрын
Question - My fan motor is overheating and shutting down after running for about 20min on a Carrier Infinity condenser. I put a new fan motor on and I am certain that it is good (bench tested). I also swapped fans from my second condenser (same model runs well in that condenser) and same problem. I tried two capacitors and I even bypassed the dual run and isolated the fan on its own capacitor and still the same problem. Any thoughts on what could be going on? Transformer, PCB? Any thoughts would be helpful and thanks for the awesome tutorial!!!
@JF0913
@JF0913 6 жыл бұрын
thanks for all your feedback....keep up the great work and videos...
@motoxposse
@motoxposse 4 ай бұрын
So if resistance between wires is common 58 other two wires 38-20 they add up however how much is to much or to less or does it matter as long as they add up
@alexandergavrilov2566
@alexandergavrilov2566 2 жыл бұрын
What if my fan starts running only if I give it a push with a screwdriver? It does stay on once I help it. It turns real easy and it doesn't look like it's "stuck". Could that mean my capacitor is bad? (It does look like it's bulging, it's also 15 years old so I just ordered a new one, but was curious if the "fan needs help to start" is one of the symptoms of a bad capacitor).
@terencescott3957
@terencescott3957 Ай бұрын
Thanks for this video. I just had to replace both motors inside and out on my unit. I'm no electrician but I want to tinker with the old motors to learn a thing or two. Before I open the casing and dissect them like a frog, I'm going to take the opportunity to learn how to test them.
@vladimirheifets6848
@vladimirheifets6848 4 жыл бұрын
Thank you for the great explanation video. I have a situation - neither the compressor nor the fan is coming on, and no noises. I changed the capacitor to a brand new one; checked the voltage before and after the contactor. When I check the voltage on the two contactor leads, it's zero; but from either lead to the ground is 120V. Is this normal (i.e. no 240V on BOTH contactor leads but 120 on each to the ground). Could this be the reason my AC is not working? The blower fan inside inside the furnace is working; the thermostat is Ok (checked it by bypassing it with a jumper as per your other videos). It's a Carrier CA13 unit. Thank you
@vladimirheifets6848
@vladimirheifets6848 4 жыл бұрын
Turns out the issue was a failed service disconnect switch. I replaced the switch and the a/c is now working.
@daniellearn1123
@daniellearn1123 Жыл бұрын
Capacitor is good. Checked resistance of fan wires - 2 lower numbers did add together to the higher number which was right around 100. Fan continues to overheat and shut off after 7-10 minutes. Could a fan with proper resistance still be failing? Or should I look elsewhere?
@DisasterDork
@DisasterDork Жыл бұрын
Good questions. Did anyone provide an answer? I also need an answer.
@MrFallred
@MrFallred Жыл бұрын
What if your condenser fan motor is over amperage? Do you have a video on that issue? Our unit was running loud outside and the air inside wasn't cooling down, and tech said over amperage was the problem and to replace condenser fan motor and that it was probably overworked this summer/older unit. If I turn AC on now the unit still works and does NOT run loud but it's still not cooling. I feel like I don't know why the motor is over amperage or what that really means, or that replacing it solves anything.
@genericusername1365
@genericusername1365 4 ай бұрын
Verified power going to unit. Replaced bad capacitor with a good capacitor, but fan still doesn't turn on. Ohm tested the three wires which come from the fan and the resistances all add up perfectly. Can the fan motor motor still be bad despite that?
@stephfong4577
@stephfong4577 4 жыл бұрын
If we have an electric furnace and an AC(also works as a heat pump), how do we test if the heat pump is generating heat, while both the heat pump and the furnace can generate heat?
@hermespetertangga-an7760
@hermespetertangga-an7760 5 жыл бұрын
Your really helping, but theres one question, how to identify the common leads wire in condensor fan motor
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
There should be a little wiring diagram on the specs label on the motor itself. Usually it shows which wire is common there. Otherwise you can look on the condenser wiring diagram and see what color wire it is there. I also have a "how to wire a condenser fan motor" video if you need it.
@samtoreno7441
@samtoreno7441 5 ай бұрын
I’m replacing a condensing fan motor and the only difference is the FLA. My original motor has an FLA of .77 and the new motor has .63 FLA. Can I use this new motor?
@WordofAdviceTV
@WordofAdviceTV 5 ай бұрын
Yes. If that is the only difference, you're good to go. 👍
@jaybro1046
@jaybro1046 Жыл бұрын
Hi, is that the same way to check a bad compressor? Check ohm between c , s and herm? Hs = cs+ch?
@losmoore3358
@losmoore3358 7 ай бұрын
I placed my fluke meter set on OHMS with the beeping sound for continuity it went from .OL to beeping on a new condensor fan motor. Are saying it's bad ? On regular OHMS reading it gave me the exact numbers that I needed a total of 118.6 OHMS.
@alexandershilling
@alexandershilling Жыл бұрын
Could you please make a video of the top five water heater problems I’m still confused about that topic
@j_cmos
@j_cmos 10 ай бұрын
Does the fan motor have to run an order for heat to work on a electrical furnace? We don't have any heat of the blower is blowing out cool air and the fan is not turning on the outside. This is the same behavior when it was below 30° and above 30°. I've checked voltage for the defrost module sensor and thermostat 24 volts all the way around.
@kennykuecha7207
@kennykuecha7207 2 жыл бұрын
Hello..should the fan always blow up-oit of unit,pulling fresh air in thru coils?I live in an town home comuinity,and the maintainance guys were worming on outside compressor unit,and now air blows into unit,and out thru coils.its not as efficiant anymore..is it as simple as switching the wires?is it a DC motor that swit hing wires changes fan direction?the unit is a Goodman GSX16S301AB..thank yoi in advance.
@earthwisdomhelps
@earthwisdomhelps 2 жыл бұрын
Where do you change the speed on an A/C condenser fan? Mine is moving slower than it should. Would I find this wiring in the condenser or air handler?
@WordofAdviceTV
@WordofAdviceTV 2 жыл бұрын
Usually condenser fan motors do not have adjustable speeds. Was it always like this or is this a recent development? If it is recent, then I would guess that either the capacitor is weak/dead or the motor is not getting enough voltage. (perhaps a fuse in the disconnect box is blown? Would need a multimeter to check for sure)
@earthwisdomhelps
@earthwisdomhelps 2 жыл бұрын
@@WordofAdviceTV The maintenance person has been messing with my AC from the condenser on purpose it was working fine and in April he pulled the disconnect switch. Then I had no AC. When I put in a work order for it to be fixed, he was sent to fix it. Only after he left the temp took an hour to drop one degree, in an 800 square foot apt. Everyone else drops 4 degrees in 20 minutes how mine did before. Now it will take 4 hours to go down 4 degrees.I went out to look at my fan because I know he is doing it on purpose. My fan is slower than everyone else. Theirs are spinning fast that you can't see the blades. Mine is different. I have a witness, another neighbor looked and said my fan is slower than the others. The maintenance man did something on the condenser to change the fan from fast to slow. I am just trying to figure out what he did not he AC condenser, if he pulled a wire or move a wire how he changed the speed.
@WordofAdviceTV
@WordofAdviceTV 2 жыл бұрын
@@earthwisdomhelps Oh man.. If this is a sabotage type of situation, it would be hard for me to try to guess what he did.. Have you tried turning off the power, taking off the electrical panel on the outside unit and seeing if there are any disconnected wires? Are you able to get someone else out there to take a look at it, besides that guy?
@earthwisdomhelps
@earthwisdomhelps 2 жыл бұрын
@@WordofAdviceTV Thats the word Sabotage. I called Rheem contractors and people who answered the phone said the fan being slow would cause it not cool. I'm not getting him to come back he doing it. I will have to hire someone but I don't know why I can't find out what he did to slow that fan. He did not come in my unit it's doing it on that condenser. What wires are switched and where to control the blades to go fast or slow? I know the air handler is in my apt. He is configuring it from the AC condenser that goes to my unit located outside. (Another thing when he left, he used an inferred gun showing it was coming out 8 degrees, out of the vents lower than the setting. Even thought it's 8 degrees lowering than what it shows on the thermodat, I found out that it's not going to matter due to the fan speed. Someone else told me, the old neighbor, he used to work on AC and said the ideal temp coming out of the vent is 20-25 degrees lower than wha the thermosdat says. I have an inferred gun my neighbors thermostat was on 72 and it was the temp from the vents was between 47 and 48.
@normquan8772
@normquan8772 4 жыл бұрын
Your videos are easy to understand! Really gave me a clear understanding how the system works and to troubleshoot. Having said that, I'm stump with the issue I'm having. The 24V sets the plunger down, but fan and compressor does not come on/no sound. There is 240V feeding into the two legs of the one-pole contactor. Disconnected the 240V from the breaker, with the plunger down, I get continuity between the in and out connectors on the plunger leg side. With 240v back on and the plunger down, do not get voltage at the output contactor terminals. If I jump the input terminal to the output terminal bypassing the plunger leg side, the compressor and fan comes on. I replaced the contactor and same symptoms. Am I missing the oblivious?
@jljordann922
@jljordann922 2 жыл бұрын
what ended up being the issue?
@david19226
@david19226 Жыл бұрын
sounds like bad contactor. replace it.
@teal_2v338
@teal_2v338 4 ай бұрын
Thanks much, you gave me trust in me , to do it myself, and finally realised it was a wire that was cut between to capacitor! Ac is back my boy!
@srillc7506
@srillc7506 6 жыл бұрын
When the ac is turned on, the condenser fan will run for about 10-15 minutes, then the fan will stop. The compressor will still be running and blow very hot air. Turn the AC off, let it sit a few minutes, turn it back on the same results occur. I changed out the capacitor, but the issue remains. Going to try and clean the unit coils next. In your opinion does this sound like a new fan motor is needed?
@WordofAdviceTV
@WordofAdviceTV 6 жыл бұрын
The fan motor has an internal overload. If it overheats, it will shut off until it cools off. That does sounds like a bad fan motor. Sorry for the late response. I was out of town.
@srillc7506
@srillc7506 6 жыл бұрын
thank you!
@papitosabe
@papitosabe Жыл бұрын
Im noticed both my fan and condenser arent kicking on. And the capacitor ive had to replace 3 times this month. Luckily its cheap. Fan motor is at .6 when it shoukd be at .5. Is that enough to kill the capacitor?
@Flyingnobull
@Flyingnobull 3 жыл бұрын
Hey great video! The fan on my ac unit stopped working. On the motherboard there is a blinking yellow light. Do you know how I can troubleshoot this?
@JeshuaKirios1
@JeshuaKirios1 4 жыл бұрын
This guy is good, thanks you are my new Teacher
@akamegakill8903
@akamegakill8903 2 ай бұрын
Im kinda confused so if the meter reads Ol that means no continuity and its good so basically you be getting OL only ?
@leonardodavinci303
@leonardodavinci303 3 ай бұрын
Excellent video. Checking mine tomorrow.
@Boogie_Tech13
@Boogie_Tech13 4 жыл бұрын
Hey. Big fan. Would there be continuity between ground and the common wire of the fan
@Michael_303
@Michael_303 5 жыл бұрын
So my AC unit has one of those Turbo 200X universal caps and a hard start kit. I'm not sure what the original cap was but the one that's in there tests at 10mfd and 175mfd. It's not bulging so I think the cap is ok. The fan doesn't spin freely and doesn't spin up with help but the fan leads tested at 27, 27 and 55 ohms. My guess is the fan motor is bad since it's really stiff to turn but I'm not sure how else I could confirm that.
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
Hey Michael! Even though the motor resistance readings are good, the motor still may be bad just like you said. The electrical windings may be fine but the motor bearing is not. If it is hard to turn I would replace the motor and capacitor. (the new motor should list in the specs which size capacitor it requires)
@Michael_303
@Michael_303 5 жыл бұрын
@@WordofAdviceTV Hey thanks a lot for taking the time to reply. The feedback and direction is really appreciated. 👍
@Michael_303
@Michael_303 5 жыл бұрын
Just wanted to follow up and let you know it was immediately apparent that my old motor was bad when the new one arrived because of how freely the new shaft spins. Got it installed and everything is good to go now. Thanks again for the videos!
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
@@Michael_303 Glad I could help! Thank you for the update, stay cool! :)
@williamsmardo1240
@williamsmardo1240 2 жыл бұрын
I know this post is old , but I'll give it a shot. My readings are 114 and 117. Does that mean , the fan is bad ?
@beachhouse131
@beachhouse131 5 жыл бұрын
Great video! So a technician replaced my fan and capacitor and the breaker is still tripping. The a/c blows cold for about 4 minutes and at this time the compressor and the fan are both running and then the condenser fan stops spinning but the compressor continues to hum and heat up. The amps to the breaker increase at this point until the breaker trips. Why does the condenser fan quite running? I assume that once the condenser fan quits the overheating compressor is causing the amps to rise which is tripping the breaker. Any Ideas? Thanks!
@WordofAdviceTV
@WordofAdviceTV 5 жыл бұрын
Hey Dan! If I am right... I would say that the new fan motor is wired incorrectly. The reason I say that is because I JUST recently did the same mistake (everyone makes mistakes sometimes..) And the customer called me back and pretty much told me exactly what you just said. I would call that guy back out to double check the wiring.
@beachhouse131
@beachhouse131 5 жыл бұрын
I think you may be right! I looked at the wiring diagram on condenser and it calls for brown and orange to run capacitor 2 from fan and a black hot lead to (not switched) side of contactor to run capacitor 2 and black from contactor (switched) to fan. New fan supplied has brown and brown/white to capacitor from fan. Black from contactor (not switched) to fan and white from contactor (switched side) to fan. New fan also has yellow and purple not mentioned in condenser diagram. yellow to yellow and purple to purple at fan. Any ideas on this? I'm still waiting to here back from technician.
@hammerridecycling7630
@hammerridecycling7630 2 жыл бұрын
a/c fan should turn on when heater is running?
@josephdeguzman7338
@josephdeguzman7338 2 жыл бұрын
Hello! I'm your avid subscriber. I already replaced new fan motor. And replaced contactors and capacitors. My problem is when giving supply to contactor only compressor is running and condenser fan motor is not running. When I plunge the contactor both is running. What could be the problem? Hope you could help me through this. Thank you.
How To Replace Air Conditioner Condenser Fan Motor
25:25
Word of Advice TV
Рет қаралды 229 М.
AC Unit Not Turning On - How to Fix It Step by Step
30:28
Word of Advice TV
Рет қаралды 3,1 МЛН
버블티로 부자 구별하는법4
00:11
진영민yeongmin
Рет қаралды 19 МЛН
Хасанның өзі эфирге шықты! “Қылмыстық топқа қатысым жоқ” дейді. Талғарда не болды? Халық сене ме?
09:25
Демократиялы Қазақстан / Демократический Казахстан
Рет қаралды 327 М.
DID A VAMPIRE BECOME A DOG FOR A HUMAN? 😳😳😳
00:56
How To Fix Your AC |Outdoor Fan Will Not Turn On
18:15
Why Not DIY
Рет қаралды 442 М.
DIY Fix AC Compressor Fan Not turning On, Just Humming
12:22
jeffostroff
Рет қаралды 287 М.
Air Conditioner Contactor - How To Check If It's Actually Bad
6:53
Word of Advice TV
Рет қаралды 738 М.
Air Conditioner Making Loud Buzzing Noise and Not Cooling in Olathe
7:26
The Air Of Authority
Рет қаралды 76 М.
How to fix your AC: fan not spinning
7:48
Kent's Garage Gym
Рет қаралды 3,7 МЛН
How I Troubleshoot an Air Conditioner Condenser Fan Motor
5:18
Fox Family Heating and Air Conditioning
Рет қаралды 221 М.
How To Diagnose A BAD Compressor | HVAC Troubleshooting
9:46
Quality HVACR
Рет қаралды 193 М.
버블티로 부자 구별하는법4
00:11
진영민yeongmin
Рет қаралды 19 МЛН