Worcesters have always been shit to work on. The life is the only one i dont mind. Viessmann boilers are just perfect to work on
@edoardoangelone69255 сағат бұрын
Thank you!!
@m.b439211 сағат бұрын
How do you fill the vessel with air
@DECOITO2614 сағат бұрын
Thank you so much. Well explained. Straight to the point I just did this, it worked.
@Mikeoxlong197816 сағат бұрын
Out of the two I would pick viessmann
@spinupone22 сағат бұрын
Thank you, very clear, concise, & well demonstrated. Great video 👍👍
@MohammedAli-123 сағат бұрын
For me, the fact that it comes out easy and goes back in easy, is the main thing.
@David-i4m8dКүн бұрын
Vaillant
@ep3thatsall485Күн бұрын
Try that with a WB 8000!😂😂😂
@ununha2 күн бұрын
Did u service navien boiler? That's no way to take the trap out
@plumber98852 күн бұрын
I keep spares , same with the logic
@belaszigeti48502 күн бұрын
the 2000 has been updated a while ago and has a proper condese siphon now. It also inherited the hex from the 4000 and able to modulate down to 3.2 KW. Not many boilers can do that for that price.
@Ibrahim-vt2tz2 күн бұрын
Well done, that was the great information and I think you’re right hundred percent
@lostinthoughtscalminsilenc81672 күн бұрын
Why have a 3 amp fuse spur when boiler already have 1amp?
@The_Dua2 күн бұрын
The baxi 430 is currently cheaper then the main eco compact, and customers love a baxi badge.
@taz10583 күн бұрын
Ideal boilers are shit and not worth the buck, Vaillant, Baxi etc are the best and every engineer is happy to work on easily, Vogue is the only Ideal boiler I would suggest as a last resource
@taz10583 күн бұрын
Bro that's how they work but I've come across idiots that swear they expansion vessel never goes.
@plumber98853 күн бұрын
Ideal where gas pipe is undersized , nowhere else can you get away with 14.5mb working pressure 😆
@plumber98853 күн бұрын
I blame the immigrants
@Zayheating3 күн бұрын
I have worked on ideal for years, they are worthless boiler I fix around 50 boiler a week, they made of plastic leaking most of the time whistling noice and more issues.
@izzyizzy27833 күн бұрын
Nicely explained my brother Jazak Allah Khair
@MichaelRees-t1j3 күн бұрын
Should have given the towel rail a clean for them at the same time😊
@b1h2u3p43 күн бұрын
Or better to get a plumber if customer dosent know what they doing
@BrickTop900Күн бұрын
He’s saying it cos he legally can’t remove it
@mohammadmannan61163 күн бұрын
Thank you brother . May Allah subhanahutaala bless you. Brother how can i contact you .Jazakallah khairan
@plumber98853 күн бұрын
The high flow 550cdi can do 25 litres a minute with the storage , and when it runs out, about 21 . It’s an absolute beast
@plumber98853 күн бұрын
Ngl , that was smoothhhhhh
@b1h2u3p43 күн бұрын
Ideal vogue never had an issue for nearly 8 years running like a dream plus stainless steel heat exchanger not the cheap aluminium
@Selvyn-tv5bt3 күн бұрын
He’s selling Maine and condemning Ideal boilers! He’s not telling the truth if you service regularly you won’t have any issues with it! It’s rubbish what he says!
@chehabmumAldoky3 күн бұрын
I have installed some 15 years ago and they are still going strong.
@gavinbingham30253 күн бұрын
I do exactly the same just with a radiator tail as I have plenty knocking about good stuff
@Adam-tn7yk3 күн бұрын
Check if the pressure goes down.
@justsendmelocation50683 күн бұрын
Main any day over Ideal.
@rafiahmadzai94423 күн бұрын
I prefer main over ideal
@suhelmiah88903 күн бұрын
Main. I also don't install ideal my brother 😂😂😂
@rafiahmadzai94423 күн бұрын
Bro you just popped up out of nowhere and I have the exact same issue. Subhan Allah this was a good one. Jazak Allah
@rickd64213 күн бұрын
The best way to detect a breach of the bladder in an expansion vessel is to shut off boiler flow and return and drain boiler with AAV open. Pump up vessel to 1 bar and maintin at 1 bar as the boiler drains until no water draining and expansion vessel still showing 1 bar.. Then , close the AAV and submerge the drain pipe and check for air bubbles for 5 mins. If no bubbles all is good. If it is an external expansion vessel it would mean removing the flexi pipe and submerging
@raul8353 күн бұрын
Absolute right decision.. Main Eco all the way over ideal logic
@chehabmumAldoky3 күн бұрын
I would like to see him handling the old potterton Neataheat in this cupboard without shredding him self
@eb2205884 күн бұрын
Cmon man. You know Vaillant is king. Also Best way to compare a brand is to look at all the boilers they have on the market. I say this bc yes the Worc 8000 had had big improvements to its prior models.
@gregkamionka38394 күн бұрын
What to use for draining system on first floor flat ? Any flexible tray on the marketm?
@j_ping5 күн бұрын
Trap wants an air gap to otherwise you’ll be back out at some point. That whole install is rank 😂
@pauliewalsh68755 күн бұрын
Are you stoned off yer tits mate?
@benc14396 күн бұрын
Brave man touching those rad valves
@tommytanswell41876 күн бұрын
Watch out for the azzy in artex ceiling bro 👊
@ImHowardMoonsir16 күн бұрын
I've ended up with loads of brackets as each vertical or long horizontal run replacement always has them in good condition for re use
@zackkhan65676 күн бұрын
Hi there ! I have the same Boiler ! I did same to fix the error but The Pressure bar went up to 2 bar Is it Ok? or is it dangerous! If so how to decrease Pressure bar back to 1.5 , mine is nearly 2 ! Kindly reply Thanks
@ImHowardMoonsir16 күн бұрын
Baxi 400s are cheaper than these mains now I've been putting them in.
@morg776 күн бұрын
Far from it, scaffolding. If you say any different you've not done it
@peteshergill7 күн бұрын
Saved me an emergency call out to a tenant. Thank you.
@STwin-z6u7 күн бұрын
Good work all one handed too haha
@PlumbingDoctors7 күн бұрын
Thanks 😅
@gasnewbie19417 күн бұрын
What was wrong with the old one
@cornelpisanu70847 күн бұрын
@@gasnewbie1941 nothing wrong with the boiler I’m just trying to prepare for future