1:40 OSL 3:55 Through 5:10 Display 6:20 StartStopFreq 6:36 Marker 7:10 Active Channel Button 7:45 CalInputReflChannel 11:00 CalOutputTransChannel
@slumdogskillionaire9236 жыл бұрын
you are a genius, thank god you made that useful video!! I need it for university purposes because my proffesor does not want to help me with it!! Thank you, again!!!
@enochmarco4483 жыл бұрын
Dont know if you guys gives a damn but if you guys are stoned like me during the covid times you can watch all the new series on instaflixxer. I've been binge watching with my girlfriend lately :)
@marceljaxson34813 жыл бұрын
@Enoch Marco yea, I've been using instaflixxer for years myself :D
@karsynkylo50023 жыл бұрын
@Enoch Marco definitely, I have been watching on InstaFlixxer for since november myself =)
@remontlive3 жыл бұрын
Thank you for special video about VNA
@roylt216 жыл бұрын
where are the rest of the videos you were talking about? Very interested in those, thanks
@Networkengie2 жыл бұрын
You mentioned about not threading in the calibration standards into your test leads as opposed to threading in the female side as a tip and you'd explain why later but you forgot to explain this. Is this because you could damage your calibration standards kit? I've heard of this a few times from others online but never understood why.
@ZL1CVD5 жыл бұрын
Some good explanations by why do you not clearly show what port you are plugging the short/open/load into?
@rfstuff52055 жыл бұрын
Chris - Thank you for your question. In this video I am connecting the open/short/load to port 1 of the network analyzer (which is the leftmost port). This way, when that part of the calibration is complete the analyzer "knows" what each of these standards are and can calibrate based on them. In the calibration we're showing the analyzer a predictable open load, a short circuit, and a 50 ohm "good" match. Once we attach the device under test (DUT) it will be able to accurately measure how well (or how badly) the DUT reacts to the input stimulus across the frequency band we're calibrating with. Let's say that the device is well matched from 50 Mhz - 1.5 GHz, and is not well matched in other frequencies. We will then see a "good" match in that band (example: < -15 dB S11) and a "bad" match (example: > 4 dB S11) in those areas. I defined "good" and "bad" in quotes because those good and bad values all depend on what you are measuring. I hope this answers your question - I welcome any additional requests to explain/clarify in the comments if others have similar questions. Thanks again.
@azadehghasemi3690 Жыл бұрын
Can we leave the port open for Open calibration when we are performing SOLT calibration?
@shayakbhattacharyya21603 жыл бұрын
Hello. You forgot to mention why the male was screwed onto the female SME and not the opposite? Would be a big help if you could clarify that
@slavapinchuk48296 жыл бұрын
When will be the next video`s ? Thank you for this one!!!
@rfstuff52056 жыл бұрын
Slava - much appreciate the feedback - this weekend I will post a follow on to this going over a simple passive device measurement (RF filter) and will work to put new content up every 1-2 weeks thereafter. Thanks again.
@lowearthorbit-delio6 жыл бұрын
thanks for the presentation
@muhammadiftikhar12066 жыл бұрын
Thanks dear very iseful
@doanhpg7 жыл бұрын
hi, thank for sharing this useful video. i have some questions but i don't know if you could leave your email here to more easily contact .
@rfstuff52057 жыл бұрын
Please post any questions you have in the comments. It may help others that have similar questions.
@doanhpg7 жыл бұрын
thank, sir. so what is the difference between the calibration from end user (e.g SOLT) and that from manufacturer's service
@rfstuff52057 жыл бұрын
A very brief explanation: When a piece of equipment is calibrated by the manufacturer (or a cal company after initial calibration has expired), the equipment's stand-alone performance is verified, i.e. they make sure that the equipment is correctly performing and reporting accurate measurements. Typically, the reference points for these measurements during calibration are the connection ports of the equipment. The purpose of a user calibration is to remove any of the losses or measurement differences from other components connected to the device under test. For example, if you are measuring a filter, it's impossible to connect it directly VNA ports without using test cables, RF connector adapters, and other components in between the filter and measurement ports of the VNA. If you measured the filter without re-calibrating the test setup (with any cables and adapters used during testing), you would not be measuring the filter 's VSWR and insertion loss. You would be measuring the VSWR and insertion loss of the filter, the test cables, and any adapters you are using . That would not be an accurate measurement of the filter. The purpose of the user calibration is to compensate for the insertion loss and VSWR effects of all components you've set up between the device under test and the VNA, in order to get an accurate measurement of only the device being tested.
@doanhpg7 жыл бұрын
thank you, i would like to talk about the manufacturer's calibration. i know that there are many tests in each calibration, for each equipment (e.g VNA). so how do we establish these tests ?