2020 NEC Grounding & Bonding Course- Grounding Electrodes Sample

  Рет қаралды 21,714

Master The NEC

Master The NEC

Күн бұрын

Пікірлер: 18
@marcramirez9076
@marcramirez9076 4 жыл бұрын
Gentlemen, Great work on Article 680 part One. I was on panel 20/17 from 1993-2014.
@AngelTorres-tk2nw
@AngelTorres-tk2nw 4 жыл бұрын
You are one of the best in the business, referring to learning the electrical code, Thank you Brother.
@cheobryan4954
@cheobryan4954 2 жыл бұрын
I appreciate your guidance..you are a true expert.
@michaelescalada2496
@michaelescalada2496 4 жыл бұрын
Very well explained and with good details
@MasterTheNEC
@MasterTheNEC 4 жыл бұрын
Glad you liked it
@jamelofrazier
@jamelofrazier 2 жыл бұрын
Hello , if I am installing a Temporary Main 100amp Outdoor Electrical Service Panel with 2 ground rods 6 feet apart within 3 feet of a Shed Sub Panel . Will I be required to add two more ground rods at the Shed Sub Panel? Even; if, I have Main and Sub Panel bonded to same two Ground Rods ?
@MasterTheNEC
@MasterTheNEC 2 жыл бұрын
If you have a remote distribution panel in the detached structure, in your case a shed, you would indeed be required to establish a grounding electrode system at the shed. Now, if the main panel and shed with remote panel are that close, nothing says you can't use the same ground rods if you wish.
@davem5392
@davem5392 2 жыл бұрын
how are you testing 25 ohms or less
@MasterTheNEC
@MasterTheNEC 2 жыл бұрын
You invest in a 3-point fall of potential meter or an Ground Resistance Meter which are expensive. Here is the cheaper option - www.fluke.com/en-us/learn/blog/grounding/earth-ground-fall-potential But, its probably easier to just put in (2) ground rods.
@davem5392
@davem5392 2 жыл бұрын
@@MasterTheNEC thank you that’s what I figured. It would be interesting to have one to experiment with. I never used one
@JustWatkins562
@JustWatkins562 Жыл бұрын
Just ran into this with an inspector, couldn't understand how to accomplish this so I just threw in two rods 😂 thank you very much for the info!!!
@BBQPitmaster626
@BBQPitmaster626 3 жыл бұрын
So the ground rods must practice Social Distancing as well?
@MasterTheNEC
@MasterTheNEC 3 жыл бұрын
LOL......
@JustWatkins562
@JustWatkins562 Жыл бұрын
That was funny 😂
@robertvillalpando5250
@robertvillalpando5250 3 жыл бұрын
👍 instructed
@capoconstruction1961
@capoconstruction1961 3 жыл бұрын
I am researching a question. 200 Amp panel. Need to run underground service conductors to two spots in rear of property. How to calculate all this? 1. Determine distance? 2. Determine future potential load? 3. Go to two tables in NEC correct?
@MasterTheNEC
@MasterTheNEC 3 жыл бұрын
We do not answer questions here. If you have a technical question please visit www.PaulAbernathy.com and post on our portal.
Electrician LIVE - Voltage Drop Explained
48:47
Master The NEC
Рет қаралды 8 М.
Table 250.66 How to Size GEC's Grounding Electrode Conductors
14:57
Electrical Code Coach
Рет қаралды 9 М.
Grounding - Safety Fundamentals (1hr:13min:19sec)
1:13:19
MikeHoltNEC
Рет қаралды 992 М.
Auxiliary Grounding Electrodes [250.54], NEC 2023, (10min:54sec)
11:14
What is the Difference Between Grounding, Bonding and Neutral?
15:15
Electrician U
Рет қаралды 107 М.
Grounding and bonding
29:15
Eaton
Рет қаралды 44 М.
Sizing Grounding Electrode Conductors- Basics of 250.66
11:37
Master The NEC
Рет қаралды 10 М.
Grounding and bonding: Definitions and details
12:42
Eaton
Рет қаралды 103 М.
General Grounding Requirements
28:47
Electrical 101
Рет қаралды 3,2 М.