3 Phase Meter Reading Malayalam | Electricity Leakage Detect | KWH Meter 3 Phase | KSEB Bill | KSEB

  Рет қаралды 27,144

Shishiram Engineering Services

Shishiram Engineering Services

Күн бұрын

3 Phase Meter Reading Malayalam | Electricity Leakage Detect | KWH Meter 3 Phase | KSEB Bill | KSEB
Some of Our other Videos-
3 Phase Main Switch Connection Malayalam | 3 Phase Main Switch | KWh Meter 3 Phase | 3 Phase Wiring
• 3 Phase Main Switch Co...
HRC Fuse | High Breaking Capacity Fuse | High Rupture Capacity Fuse | HRC Fuse Working In Malayalam
• HRC Fuse | High Breaki...
Switch Disconnector Fuse | SDF | Difference Between SFU and SDF | L&T SDF | 3 Phase SDF Malayalam
• Switch Disconnector Fu...
Fuse & Main Switch Connection Malayalam | KSEB Energy Meter Connection | Safe Fuse Replacement |Fuse
• Fuse & Main Switch Con...
How To Fix Fuse At Home In Malayalam | Fuse | Fuse Wire | Electric Fuse | Fuse Types | Blown Fuse
• How To Fix Fuse At Hom...
KSEB Meter Reading Malayalam | KSEB Bill | KSEB Consumption Calculator | Electricity Leakage Detect
• KSEB Meter Reading Mal...
In this video, I have explained how to take reading in 3 phase meter in Malayalam. 3 Phase AC static watthour meter of L&T ER300P. How to take daily energy consumption with digital energy meter. How to check earth leakage in home with 3 phase digital energy meter.
How to conserve energy by daily checking the consumption and controlling the usage. KSEb meter reading values t1,t2,t3 what is it. explained in malayalam. TOD tariff is time of day metering tariff.
#electricaltutorial #housewiring #3phasewiringforhousewiring #3phasewiring
Query to solved in this video
how to check earth leakage
how to check earthing without multimeter
how to check earthing in home
how to check earthing
how to check earth leakage fault
how to check earth leakage in house wiring
how to check earth leakage using energy meter
how to check earthing using digital energy meter
how to check earth leakage in house wiring malayalam
3 phase energy meter reading calculation
3 phase energy meter
3 phase energy meter unit calculation
3 phase energy meter reading
3 phase energy monitor
how to take 3 phase meter reading
3 phase meter reading malayalam
3 phase meter bill calculation
3 phase meter stop
kwh meter reading calculator
earth leakage test
earth leakage test malayalam
earth leakage
earth leakage detector
earth leakage malayalam
earth leakage tester
Shishiram Engineering Services is a One-Stop Solution For Electrical Engineering Services. We provide complete electrical engineering & project management services in all scales & ranges Shishiram Engineering Services is a distinguished engineering service company providing engineering & project management services to various industrial segments. Presently we specialize in Electrical engineering consultancy service, Electrical contracting service, Electrical chartered engineering service, Switchgear panels LT/HT designing, fabrication, installation and commissioning service, Electrical maintenance industrial & commercial service, Electrical approval & liaisoning services. We are based in Kannur, Kerala and we work on projects located all over Kerala as well as on special requirements from clients we do our services overall India and also international locations.
For more details visit our website
shishirameng.com/
email us: info@shishirameng.com
Contact us: +91 8606472279
#shishiramengineeringservices #electricalconsultantkerala #electricalconsultantkannur #electricalcontractorkannur #electricalcharteredengineerkannur #electricalservicekannur #amrutshishirmohanan #shishiramelectricalservices #bestelectricalcontractorkannur #topelectricalconsultancykerala

Пікірлер: 103
@muhammedilyash2187
@muhammedilyash2187 2 ай бұрын
വളരെ അധികം ഉപകാരപ്പെട്ട Video. Thank you so much........
@jayaprasad2806
@jayaprasad2806 Ай бұрын
സൂപ്പർ Tks
@dinujviswanathan9240
@dinujviswanathan9240 3 жыл бұрын
Hello, As mentioned by you that to detect any electricity leakage; the load should show zero on all the 3 phases. Should the power factor also show zero?
@tigythomas1210
@tigythomas1210 2 жыл бұрын
What is Apf
@shajiabu3613
@shajiabu3613 2 жыл бұрын
Can you please do a 3ohase netmeter reading. Landis+gyr
@shasbakersshoppee2937
@shasbakersshoppee2937 3 жыл бұрын
ഏത് product ഉപയോഗിക്കുമ്പോൾ ആണ് കൂടുതൽ unit ചിലവാകുന്നത് എന്ന് ഇതിലെ ഏത് ഓപ്ഷൻ ഉപയോഗിച്ചു കണ്ടു പിടിക്കാം
@shishiram
@shishiram 3 жыл бұрын
KW will give power use for the time... keep watching and supporting our channel by like, share and comments..
@kjpillai9164
@kjpillai9164 3 жыл бұрын
Very goodn guideline thanks
@shishiram
@shishiram 3 жыл бұрын
Most welcome Thanks... Stay subscribe with bell button pressed. if you find video good.. please like and share this video to friends and family
@7sparrow684
@7sparrow684 3 жыл бұрын
Really informative video.. 3 Phase കാണിക്കുന്നതായി 1 2 3 enna numbers blink ചെയ്യുന്നതിന്റെ meaning onnu pranju തരാമോ?
@sasikumar6117
@sasikumar6117 2 жыл бұрын
Please give your good information what is T and T1,2,3 and B1,2,3, showing kwh. what is deference T1 and B1 how to calculate kwh meter reading kwh which one we want take T1 or B1 Thanks.
@hamzathamarath2833
@hamzathamarath2833 3 жыл бұрын
Thank you
@suras8762
@suras8762 3 ай бұрын
3phase solar meter enganeya reading nu parayuo
@user-hp4gm6dc1b
@user-hp4gm6dc1b 4 жыл бұрын
Good. Useful information. Can you please post a video on different types of 3 phase distribution boards with selector switches to be used for domestic purpose as well as for commercial purpose with various loads and circuits. It will be helpful.
@shishiram
@shishiram 4 жыл бұрын
Will try. Stay subscribe with bell button pressed
@bibinkunjumon
@bibinkunjumon 2 жыл бұрын
Very helpful bro..thanks
@muhammednihalm.t5383
@muhammednihalm.t5383 3 жыл бұрын
Hi, I have a 5kw single phase solar connection at my home. And 3 phase net meter . First few months the export was more than the import (avg imp- 250 and avg exp- 500) Then suddenly one month the import was 750 and export was 391 ( this is one month bill) Now for few months its been going on like this the import is more than the export... So i tried this method to check if there is any leakage ...turned off everything ..then checked the load currents Lr -5.5A Ly- 0.00 Lb - 0.00 So i tried turning off each mcb’s still i got the same reading...then elcb i turned off ..same reading...then turned off the SDF from the meter-still same reading. Lr was around 5.5A. Then i tuned of the the main switch of the solar meter single phase ...the the reading in the net meter Lr became 0.00 So what should i do ...is it normal to show load current in net meter if only solar meter is on?
@aswathypa
@aswathypa 5 күн бұрын
Sir, ente veetil last month bill valare kooduthal ayrnu.. Normal casil 400 unit anu njangalude consumption varunath.. Last mnth 900 vannu.. Sir paranja prakaram njan meter reading nokkumbol 15155 anu njangalde kwh... But electricity billil vannath 15558 ennayrnu.. Eth engana varunnath.. Njangalude 3 phase anu.. Vere ethnkilm unit ethinte koode add cheyyumo?ath meter readerk mistake pattiyatgano? Plz reply
@rajithr7228
@rajithr7228 3 жыл бұрын
In my home we got a bill of 1.75L last month and around 20000units consumed as per meter. Its a closed home only a refrigerator is working . As per KSEB there is some leakage and no issue withe meter. We have called 3 electrician to check none of them found any issue with wiring or earth . They told its has a automatic trip switch so if any leakage it will cut off . We updated same to KSEB so they installed a parallel meter and told no issue with meter and we need to pay the bill. Am not sure where is the issue. Our usual bill is around 300-500rs range. On Aug month also we got a bil of 5k and we complained . KSEB people came and checked and told no isssues in meter so we paid this amount . New new bill is 1.75 L . After august we were monitoring this meter reading on daily basis it was around 2-3units per day. We thought its working fine so for a week we didn't take reading. After a week when we checked it s showing as 20k consumption. If there is a leakage can it run so much? Also if leakage is there it should show 200 units per day as per the latest reading but here meter ran this much in a week time .
@shishiram
@shishiram 3 жыл бұрын
this is serious issue because payment is too high... 200 unit per day means... 8.33 KW load per hour... that is if single phase 41.6 A.... so if this leakage is happening this not small it should be visible... or if single phase SFU fuse which normally 32 A should go... I can not comment much on it ... without seeing.. but it should checked by good electrician..
@rajithr7228
@rajithr7228 3 жыл бұрын
@@shishiram thanks a lot for replying. Already 3 people checked and found no issues as per them if any leak it will auto cutoff . Per kseb people are not willing to listen . So going for a case is the option. This much u it's was consumed in a week actually when we stopped taking reading.
@rajank.j8334
@rajank.j8334 4 жыл бұрын
You said PW need not be taken seriously by domestic consumer . But the current calculation is watt in to time divided by 1000 into PF (1000&PF) so if PF is less than 0.9 say 0.7 or .08 then reading will be high . Kindly clarify .
@shishiram
@shishiram 4 жыл бұрын
In single phase kW = (V × I × PF) ÷ 1,000 and 3 phase kW = (V × I × PF × 1.732) ÷ 1,000 in domestic bill they are considering KW only.... if for KW, pf is multiplied to get...technically if pf is less then KW is less.... but KVA is increases, KVA is considered for industrial load above 20KW incentive and disincentive shall be applicable to LT industrial consumers with a connected load of and above 20 kW, HT&EHT Consumers for power factor improvement.
@jithinsankarm1590
@jithinsankarm1590 Жыл бұрын
What if the Ampere current in meter doesn't become zero and stay within value of .34 even after switching off every load.. Does it mean there is a leakage?
@rejijohnson8599
@rejijohnson8599 3 жыл бұрын
Good. Useful information
@BoldKing71
@BoldKing71 3 жыл бұрын
Left സൈഡിൽ താഴെയുള്ള അക്ഷരങ്ങൾ ക്ലിയർ ആയി കാണുന്നില്ല. ഫോട്ടോ എടുത്തപ്പോൾ ഗ്ലെയർ വന്നു. ഡിസ്പ്ലേ സ്ക്രീൻ മാത്രം കുറച്ചു വലുതായി കാണിച്ചാൽ കുറച്ചു കൂടി നന്നാകുമായിരുന്നു. 🥰
@m.d.dilsadcharminar5014
@m.d.dilsadcharminar5014 3 жыл бұрын
A la Anna meetarr kaiy kond nekkathe daily yunnt athara ayin Arians pattulla ale
@abdullakutty3547
@abdullakutty3547 2 жыл бұрын
1phase meeter reading
@praveenvasudev2722
@praveenvasudev2722 2 жыл бұрын
Sir earth wire lea current varunnu what is tha problem veetial aane e problem
@bineethkalathil4587
@bineethkalathil4587 2 жыл бұрын
Genusmetter reding paranjutaramo
@shishiram
@shishiram 2 жыл бұрын
All are almost same...check kwh
@yesudasaravindam3155
@yesudasaravindam3155 3 жыл бұрын
2.2kw connected load 215V single phase 14A, but power factor 0.55 No more leakage and electricity bill Rs.6000/2 months. What will be the reason and solution for this? Myself suggested to install capacitor bank its right or not? Connected load including 90w Airater 20numbers
@johnpmt
@johnpmt 3 жыл бұрын
how to get cumulative phasewise consumption in 3 ph , if exist. Similar to time/day
@veenanambyar7250
@veenanambyar7250 4 жыл бұрын
Can you please put a video for understanding LT 4A electricity bill calculation
@shishiram
@shishiram 4 жыл бұрын
I done this video long before... please check this link before Stay subscribe with press bell button...also check other video to find many other informative video kzbin.info/www/bejne/qp_Qg2SnqNxjf6c
@veenanambyar7250
@veenanambyar7250 4 жыл бұрын
@@shishiram sir.. that is for domestic I would like to know about industrial LT 4A reading with include calculating T1 T2 T3 tariffs
@shishiram
@shishiram 4 жыл бұрын
@@veenanambyar7250 this is for LT4A... sorry by mistake I put the wrong link... this is for industrial load kzbin.info/www/bejne/p5W5gYNva8umZ7s is for your load is higher than 20 KW then only T1, T2, T3 comes to picture... Regarding TOD metering I have mentioned in some of this video kzbin.info/www/bejne/nHrJnKGZndKAr8U if so.. Billing Procedures under ToD tariff system for LT-IV Industrial, HT & EHT consumers 1. Demand Charges (DC) (i) The recorded maximum demand during normal time zone (T1) from 06.00 hrs. to 18.00 hrs. = RMD1 (ii) The recorded maximum demand during peak time (T2) from 18.00 hrs. to 22.00 hrs. = RMD2 (iii) The recorded maximum demand during off-peak time (T3) from 22.00 hrs. to 06.00 hrs. = RMD3 (iv) Recorded Maximum demand during a billing period, RMD= RMD1, RMD2 or RMD3 whichever is higher. Normal Period (06.00 hrs. to 18.00 hrs.) Peak Period (18.00 hrs. to 22.00 hrs.) Off-Peak Period (22.00 hrs. to 06.00 hrs.) Energy charge 100% of the ruling tariff 120% of the ruling tariff 90% of the ruling tariff (v) The Contract Demand (kVA) = CD (vi) The Ruling Demand Charge (`/kVA) = D (vii) Billing Demand, BMD = RMD or 75% of the CD whichever is higher. (viii) Demand Charge, DC = BMD × D (ix) Excess Demand for LT, HT& EHT consumers in each time zone shall be: (a) in Time Zone (T1), ED1 = (RMD1-CD) (b) in Time Zone (T2), ED2 = (RMD2-CD) (c) in Time Zone (T3), ED3 =[RMD3-(1.30× CD)] (x) Excess Demand Charge (ED) = Excess demand ED1, ED2 or ED3 whichever is higher × 0.50 × D (xi) Total Demand Charge (TDC) = DC + ED 2. Energy Charges (EC) (i) The energy consumption in Time Zone (T1) = X1 (ii) The energy consumption in Time Zone (T2) = X2 (iii) The energy consumption in Time Zone (T3) = X3 (iv) The Ruling Energy Charge (`/unit) = E (v) Energy Charges in each time zone shall be : (a) in Time Zone (T1), Ec1 = X1 × E (b) in Time Zone (T2), Ec2 = X2 × E × 1.5 (c) in Time Zone (T3), Ec3 = X3 × E × 0.75 (vi) Total Energy Charge (EC) = Ec1+Ec2+Ec3 3. Total Monthly Charges = TDC + EC
@renadevkk3881
@renadevkk3881 Жыл бұрын
Good
@shahrukhaman4088
@shahrukhaman4088 3 жыл бұрын
Good explanation sir👍.. Thank you
@ronygeorge3125
@ronygeorge3125 3 жыл бұрын
Can we. See phase current and neutral current in 3 phase meter can we identify earth leakage by this way
@shishiram
@shishiram 3 жыл бұрын
No ... I will do a video on it later.. Stay subscribe with bell button
@ajudevassy9880
@ajudevassy9880 4 жыл бұрын
Db wire size meter to main switch single phase and three phase how much mccb amp selection for normal house
@rajank.j8334
@rajank.j8334 4 жыл бұрын
You said PF (power factor) need not be taken seriously for demestic consumer .But I think it had effect for reading . Because calculation for current consumption is watt in to time divided by 1000 (PF) If power factor is less then reading will be high . Kindly clarify
@shishiram
@shishiram 4 жыл бұрын
Wire size to mains switch use 6 sq mm for load and MCB use 32A
@shishiram
@shishiram 4 жыл бұрын
In single phase kW = (V × I × PF) ÷ 1,000 and 3 phase kW = (V × I × PF × 1.732) ÷ 1,000 in domestic bill they are considering KW only.... if for KW, pf is multiplied to get...technically if pf is less then KW is less.... but KVA is increases, KVA is considered for industrial load above 20KW incentive and disincentive shall be applicable to LT industrial consumers with a connected load of and above 20 kW, HT&EHT Consumers for power factor improvement.
@jeehas1358
@jeehas1358 3 жыл бұрын
Sir.. plz reply, single phase meter il daily unit ariyan patumo.. athil kWh mathrame ulu.digits mukalil ninnu thazhek aakunna poleyanu. Ithil oru number und. Ath monthly used unit aayrikumo daily used unit aayrikumo.
@bibinkunjumon
@bibinkunjumon 2 жыл бұрын
Appo TOD ippo house connection illa le
@naroth42
@naroth42 4 жыл бұрын
Energy CONSUMPTION
@shishiram
@shishiram 4 жыл бұрын
For energy bill calculation check this video kzbin.info/www/bejne/qp_Qg2SnqNxjf6c
@shijinsk1791
@shijinsk1791 3 жыл бұрын
After cumulative kwh reading, another kwh reading showing with suffix BP, BP1,BP2,..What is mean by this
@hashifibrahim4012
@hashifibrahim4012 2 жыл бұрын
സർ ഞാൻ പുതിയതായി വീട് വെച്ച് മൂന്നു വർഷമായി 3Phase line, normal 1300 രൂപയായിരുന്നു bill amount വന്നിരുന്നത് കഴിഞ്ഞ ആറുമാസം മുമ്പ് 7000 അധികം ബിൽ amt വന്നതു കാരണം പരാതി കൊടുത്തു മീറ്റർ മാറ്റിയെങ്കിലും കഴിഞ്ഞ പ്രാവശ്യവും കൂതലാണ് bill amt. സാറിൻ്റെ വീഡിയോ കണ്ട ശേഷം മൊത്തം ഓഫ് ചെയ്ത ശേഷം പരിശോധിച്ചപ്പോൾ. ബാക്കി line zeroആയിരുന്നെങ്കിലും Y line മാത്രം യൂണിറ്റ് കാണിക്കുന്നുണ്ടായിരുന്നു. db ബോക്സിലും Yellow light ഓൺ ആയി കിടക്കുന്നുണ്ടായിരുന്നു, എന്തായിരിക്കും ലീക്കേജിന് കാരണം. സാറിൻ്റെ വിലയേറിയ ഉപദേശത്തിനായി കാത്തിരിക്കുന്നു.
@agk1868
@agk1868 3 жыл бұрын
Genus ത്രീഫേസ് മീറ്ററാണ് എൻറെ വീട്ടിൽ ഉള്ളത് നിലവിൽ ഈ മീറ്റർ റീഡ് ചെയ്യാൻ വരുന്ന ആളുടെ ബില്ലിംഗ് മെഷീൻ ആയിട്ട് വയർലെസ് ബന്ധപ്പെടുതിയാണോ ബിൽ തയ്യാറാക്കുന്നത്?
@fhameen
@fhameen 4 жыл бұрын
3phase not domestic businesses (shope) tharif? Monthly... calculated.
@shishiram
@shishiram 4 жыл бұрын
See these 2 two video for complete information kzbin.info/www/bejne/ZoXWfJKcabKdjLc kzbin.info/www/bejne/jqKomIp_jJpkqZI
@petergeorge8737
@petergeorge8737 2 жыл бұрын
ഹോ ഒത്തിരി താമസിച്ചു പോയി .. അന്വേഷിച്ചു നടക്കുവായിരുന്നു... ഒരു സംശയം ചോദിക്കട്ടെ .. 22 യൂണിറ്റ് ഒക്കെ സാദാരണ ഒരു വീട്ടിൽ വരുമോ.. രണ്ടു ac മൂന്ന് ഫാൻ രാത്രി വർക്കിംഗ്‌ ആണ് ... എന്നാൽ പോലും ഇത്ര യൂണിറ്റ് വരുമോ ഇനി പറഞ്ഞത് പോലെ ഒന്ന് ചെക്ക് ചെയ്യട്ടെ .. ഒരു സംശയം അപ്പോളും ഉണ്ട്... മൂന്നു ഫൈസിൽ ഒരു ഫേസ് amp കാണിക്കുക ആണേൽ ആ ഫസ് ബ്രേക്കർ മാത്രം ചെക് ചെയ്താൽ പോരെ .. എത്ര സമയം കഴിഞ്ഞയിരിക്കും ഇതു സീറോ പൊസിഷൻ വരുന്നത് ലീക് ഇല്ലെങ്കിൽ ... എന്തയാലും ഒത്തിരി നന്ദി
@nourfarooki7079
@nourfarooki7079 4 жыл бұрын
3 phase Tharif System ariyikku, Please. വീട്ടൽ 3 phase. Over Bill ആണ്. Fridge മാത്രം work ചെയ്യുമ്പോൾ 6 മണിക്കൂറിന് 1 unit വരുന്നുണ്ട്. 4 unit per day. ഇത്രയും വരുന്നത് എന്ത് കൊണ്ടാണ്?
@shishiram
@shishiram 4 жыл бұрын
Hi, I have done many videos before on similar topics tariff system for domestic 3 phase and 1 phase kzbin.info/www/bejne/qp_Qg2SnqNxjf6c Regarding energy consumption of fridge and other home types of equipment kzbin.info/www/bejne/poe1mIOqabtkh5I
@shahrukhaman4088
@shahrukhaman4088 3 жыл бұрын
Is this meter called 3 phase energy meter or LT TOD meter?
@siddik456
@siddik456 3 жыл бұрын
Landis gyr e250 മീറ്ററാണ് three phase ഇതിന്റെ റീഡിങ്ങ് ഒന്നും മനസ്സിലാവുന്നില്ല,വിവരിച്ചാൽ നന്നായിരുന്നു
@Afsalmuhammad
@Afsalmuhammad 3 жыл бұрын
നോർമൽ ഫേസ് ലീക്കേജ് എങനെ കണ്ട് പിടികആം
@Evangel1000
@Evangel1000 3 жыл бұрын
സാർ, 6pm To 10pm സമയങ്ങളിലെ വൈദ്യുതി ഉപയോഗം സാദാ വ വീടുകളിൽ കറണ്ട് ബിൽ കൂടാൻ ഇടയാക്കുമോ?
@santhoshkumarperinthalmann1176
@santhoshkumarperinthalmann1176 4 жыл бұрын
👍👍👍👍👍
@shishiram
@shishiram 4 жыл бұрын
Thank you...
@sasirajn2193
@sasirajn2193 4 жыл бұрын
Neutral to Erth 50v what is problem
@shishiram
@shishiram 4 жыл бұрын
many chance are there... 1. induction voltage from phase and neutral 2. leakage due to week insulation 3. neutral overload...like many loads connected one neutral.. so on...
@sasirajn2193
@sasirajn2193 4 жыл бұрын
@@shishiram thanks
@sasirajn2193
@sasirajn2193 4 жыл бұрын
Thanks
@prakashpr2007
@prakashpr2007 4 жыл бұрын
വീട്ടിൽ induction current ഉണ്ടെങ്കിൽ അത് എന്താണ് സൂചിപ്പിക്കുന്നത്? അതിനെ എങ്ങനെ ഒഴിവാക്കാം...
@shishiram
@shishiram 4 жыл бұрын
Induction current normally happens when long wire and tightest/closely packed wiring in the conduits... avoid these
@shishiram
@shishiram 4 жыл бұрын
Thanks ... Stay subscribed with bell button press. If you find video informative like and share to friends and family.
@prakashpr2007
@prakashpr2007 4 жыл бұрын
Induction current ano fan switch off and on cheyumbol tv screen automatically off ayi on akum( screen matram that too for a few seconds) ithu same roomile switchilum nearby roomile switch on/off cheythalum ithu sambhavikkum. Is this due to induction current?
@prakashpr2007
@prakashpr2007 4 жыл бұрын
@@shishiram likes and subscribed... very informative video too and good presentation also...
@prakashpr2007
@prakashpr2007 4 жыл бұрын
@@shishiram ithu current charge koottumo?
@gkuttikattu
@gkuttikattu 4 жыл бұрын
Single phase and 3phase difference in charges
@shishiram
@shishiram 4 жыл бұрын
Difference only in fixed charge....and no change in energy charge...
@mohanakumar7830
@mohanakumar7830 3 жыл бұрын
മൾട്ടിമീറ്റർ റുമായി ബന്ധപ്പെട്ട ഒരു വീഡിയോ ചെയ്യുമായിരുന്നെങ്കിൽ നന്നായിരുന്നു
@shishiram
@shishiram 3 жыл бұрын
Ok.... Sure...Stay subscribed with bell button pressed to all... If you find our video informative, like and share to friends and family...
@SureshKumar-mg6uy
@SureshKumar-mg6uy 2 жыл бұрын
റീഡിംഗിന് താഴെ 2 എന്ന് കാണിക്കുന്നു അത് എന്താണ്?
@gururajkamath5188
@gururajkamath5188 4 жыл бұрын
👍👍
@shishiram
@shishiram 4 жыл бұрын
Thanks...
@gururajkamath5188
@gururajkamath5188 4 жыл бұрын
@@shishiram please send mob. Number
@raisalbabu8122
@raisalbabu8122 4 жыл бұрын
വീട്ടിൽ എർത്ത് ലീകേജുണ്ട് അതു ഒന്നു ശരിയാകിതരുമോ ! ഒവർകറന്റുബില്ലുകാരണം 3kwസോളാർചെയിതിട്ടുണ്ട്
@shishiram
@shishiram 4 жыл бұрын
If you confirm there is leakage then better fix it first... with good technician around your home...
@reghukeralavarma6640
@reghukeralavarma6640 4 жыл бұрын
11 Kv TO D മീറ്റർ റീഡിങ്ങ് എടുക്കേണ്ട വിധം (L & TMeter) ഒന്നു പറഞ്ഞു തരുമോ
@shishiram
@shishiram 4 жыл бұрын
Sure.... stay subscribe but very few people will be interested to see this topics... but one day i will do it for u...
@user-hp4gm6dc1b
@user-hp4gm6dc1b 4 жыл бұрын
I also would like to watch this video once you uploaded.
@bijujosephmm
@bijujosephmm 4 жыл бұрын
ഇന്ന് 45 ദിവസത്തെ reading 275 യൂണിറ്റ് ആണ്. എന്നാൽ average 610 ആണ്. ഈ മാസം telescopic താരിഫിലേക്കു മാറുമോ?
@shishiram
@shishiram 4 жыл бұрын
calculation is done by software not manually .. i think they normally set for365/12 =30.4 days for 1 month.. calculate accordingly..
@nabuadm8703
@nabuadm8703 3 жыл бұрын
whats app aayi.oru grop.tudangiyal nannayirunnu
@shishiram
@shishiram 3 жыл бұрын
Hmmm...can consider...
@othmanvak
@othmanvak 4 жыл бұрын
Veetil oru mic set for cheithittundayirunnu athil ninnum cheriya Earth adikkunnu enthanu karanam athin oru pariharam please
@shishiram
@shishiram 4 жыл бұрын
please give proper earthing to the instrument...it is not safe using mic without proper earthing
@mohammedsabith6425
@mohammedsabith6425 3 жыл бұрын
helooo
@nothingisimpossiblesreelal347
@nothingisimpossiblesreelal347 3 жыл бұрын
Good
@samad2705
@samad2705 3 жыл бұрын
വോൾടേജും വാട്ടേജും തമ്മിലുള്ള വ്യതാസം ഒന്ന് പറഞ്ഞുതരുമോ
Logo Matching Challenge with Alfredo Larin Family! 👍
00:36
BigSchool
Рет қаралды 21 МЛН
UNO!
00:18
БРУНО
Рет қаралды 4,9 МЛН
Parenting hacks and gadgets against mosquitoes 🦟👶
00:21
Let's GLOW!
Рет қаралды 13 МЛН
The Giant sleep in the town 👹🛏️🏡
00:24
Construction Site
Рет қаралды 19 МЛН
Why 1.5 V to 3 V Voltage Between Neutral & Earth | Electrical Neutral | Neutral Leakage Problems
10:39
ഇത് കേട്ടപ്പോൾ ഞെട്ടിപ്പോയോ :...?
11:35
KSEB Meter reading and Bill Calculation
4:10
Malayalam Tech Channel
Рет қаралды 15 М.
Logo Matching Challenge with Alfredo Larin Family! 👍
00:36
BigSchool
Рет қаралды 21 МЛН