This is good. You keep things simple. Easy to understand. Thank you for sharing.
@palavarastogi4249 Жыл бұрын
THANKS ALOT FOR THE SESSION IT WAS REALLY GREAT....FULL OF KNOWLEDGE....
@mayank485610 ай бұрын
Great video , refreshed concept in 2023 . With plus minus changes now in fcom
@poh10 ай бұрын
Yes there is an update will try to make a new one
@TheGibby33405 жыл бұрын
Just a point of interest...Outside temp is not skinair temp. The skinair heat exchanger is simply a boxed section between two ribs. On ground the heat dissipation by it can be enough to melt snow and ice in the right conditions. Point being sometimes on ground the configuration is open when you might expect closed. Or the other way around if the a/c has just arrived and the skin is still cold soaked.
@poh5 жыл бұрын
Thank you!
@RohitSharma-zg2ys Жыл бұрын
skin hear exchanger doesn't have coolant. it installed above the cockpit door between frames 12 and 14 in close circuit config. when hot air touch the A/c skin it cools down. A drainage system is included to remove any condensation when the heat exchanger is in operation.
@poh10 ай бұрын
Thank you
@渡边快斗 Жыл бұрын
Thanks for sharing this amazing lesson!
@strato1722 жыл бұрын
The EXTRACT pb in OVRD forces the system into a closed configuration (and AC air is added to the ventilation air). It doesn't "give the system a chance", it commands it to go into closed config plus AC air.
@poh2 жыл бұрын
Technically if you see it's not fully closed circuit as it says in the manual. The cargo underfloors circulation is cut off. Hence its not exactly a closed circuit configuration.
@NetiNaik4 жыл бұрын
Hello, firstly thanks for uploading these videos, they are quite helpful! 😊 I am unable to wrap my head around the ground/flight threshold definitions. Considering ground threshold, for example, what does “+12˚C, temperature increasing” mean? Can you explain what happens if the ambient air temperature is 13˚C/11˚C/8˚C while the aircraft is parked at the bay? The language used in FCOM is quite confusing.
@poh4 жыл бұрын
You're welcome! Read the following one by one and slowly! 1) Its above 12 outside it remains open 2) If its increasing it remains open 3) If its decreasing and becomes 11 it remains open 4) at 10 remains open 5) at 9 remains open 6) Below 9 it goes closed A) if its below 9 it'll be closed B) if its decreasing it'll remain closed C) if its increasing if 10 it'll remain closed D) if its 11 it'll be closed E) if its 12 it'll be closed F) if above 12 it'll open again!
@NetiNaik4 жыл бұрын
@@poh Amazing, I finally understood!! Thank you so much for the clarification!! 😊
@oscarortega60064 жыл бұрын
Best flight instructor that there is on the internet
@RATINDEXA3202 жыл бұрын
Great video. In abnormal configuration, since the air is not being discharged anywhere, where does it go? You got AV from the duct allowing air under some pressure going in. you got both fans running. Skins are closed, exchange by pass closed. Where does all this "excess" air go to? Also, when air vents to the underfloor, isnt the underfloor unpressurized? where does this underfloor air go to later on?
@poh2 жыл бұрын
There is no excess air, you actually need air because that's why pressure is low in the ducts. Once the system is fine the fault goes away and you've to reset the system to normal and ECAM disappears. Cargo underfloor is pressurized place only. It comes back to the system again.
@CptMouath Жыл бұрын
What about the ventilation of the Cockpit Instruments & Cockpit CBs? In the chart I see only the air passes through the Avionics EQPT! What's the purpose of the SKIN EXCH OUTLET BYPASS VALVE? Why does the air goes to the Avionic Bay? What is Avionic Bay actually? Aren't the EQPTs supposed to be in there? When Airbus FCOM says: "When the EXTRACT pushbutton is set at OVRD, the extract fan is controlled directly from the pushbutton. Both fans continue to run"... So, If the authority of the EXTRACT fan is now transferred from the AEVC to the pilot .. What the hell is the purpose of that if we can't stop the FAN or do anything with FAN???!!! You airbus give me the authority without the ability to control? I have never seen such a very bad documentation publication... There's so so many discrepancies in the Airbus FCOM and a miswritten explanations in terms of context and common sense! Thank you for the effort!
@aviator50383 жыл бұрын
Impressive video, dear please explain about GEN 1 LINE push button as well, which is on EMERGENCY ELECTRICAL POWER PANEL. Thank you.
@poh3 жыл бұрын
If you press that button you're preparing the aircraft for an emergency electrical configuration, generally used during smoke procedure.
@bazokazoro45634 ай бұрын
@@pohmore details please do we loose all the 80/90VUs
@zahrarekiza7067 жыл бұрын
amazing explanations, thanks a lot!!!!
@poh7 жыл бұрын
Thank you!
@rayharkins146 жыл бұрын
You are an excellent teacher.....
@poh6 жыл бұрын
Thank you
@tryityourself38706 жыл бұрын
Very good video thank you The skin Heat exchanger. do you think the temperature limitations for closed circuit configuration are to ensure the skin is of a cool enough temperature for the exchanger to work effectivly? Thanks
@poh6 жыл бұрын
Yes you are right! :)
@woodpeckerhp5 жыл бұрын
@@poh Why open circuit when it's 9 and decreasing, isnt it going to overcool the compartment?
@poh5 жыл бұрын
When temperature outside is 9 and the air temperature inside is decreasing.. so that means its hotter outside than inside.. so it will help in neutralize the temperature..
@woodpeckerhp5 жыл бұрын
@@poh Got it, 9 degree outside and inside temp is decreasing.
@poojamane88742 жыл бұрын
Great explanation as always but could you please explain more about > OR < skin temperature threshold, As skin temperature threshold is not a fixed value but more of a range itself that too moving on both the side 9 and decreasing and 12 and increasing, Hope you understood my doubt.
@asdf567ish3 жыл бұрын
Thanks a lot , you explained it so well.Best wishes
@breks30996 жыл бұрын
Tremendously well explained! :)
@poh6 жыл бұрын
Thank you
@a320training55 жыл бұрын
A fantastic explanation. Nicely done. 👍
@poh5 жыл бұрын
Thank you!
@captainankush292 жыл бұрын
Well explained ✈️
@sagarawirasinha32696 жыл бұрын
Wonderful explanation. Thank you so much...
@poh6 жыл бұрын
You're welcome!
@thomaskientz83383 жыл бұрын
Very nice explanations ! Thanks for your time ;)
@poh3 жыл бұрын
You're welcome!
@alharathmohamed-57687 жыл бұрын
thank u so much its been very helpful for me
@poh7 жыл бұрын
Pleasure! :) You're Welcome!
@dharatripathi35067 жыл бұрын
Thank you so much, Sandesh! It's extremely helpful!
@poh7 жыл бұрын
+Dhara Tripathi You're welcome!
@reen18022 жыл бұрын
hi, thanks for explaining this so well.
@julioar17 жыл бұрын
Thank you so much, was very helpful, I have a question, what is the meaning of "Skin temperature threshold"? is the temperature outside? temperature aircraft's skin (fuselage) outside? Im a bit cofused about that.
@poh7 жыл бұрын
+Julio Arellano Temperature of the aircraft skin or fuselage on the outside.
@julioar17 жыл бұрын
You are the best, thank you!
@poh7 жыл бұрын
+Julio Arellano You're welcome
@YeeKhaiify4 жыл бұрын
I m sorry . I still don’t quite get on ground threshold : 12degree Celsius and increasing or 9degree Celsius and decreasing . What do you mean by 12 degree c and increasing ?
@poh4 жыл бұрын
Skin temperature of the aircraft is 12 degrees and increasing (skin temperature of the aircraft increasing). 9 and decreasing also means the same. They have given two values with a gap of 3 degrees so that there is no unnecessary changes in the configuration by just a change of 1 degree or so. Either the temperature has to go completely above 12 or come below 9. In between it stays where it is was last. The 3 degree gap is also because of inaccuracy in measurement of temperature by the sensors.
@aviators61995 жыл бұрын
Can u please upload a video on air condition sensors like temp sensor press and overheat sensors thank u
@poh5 жыл бұрын
What do you want to know about them?
@kedarpandya43 жыл бұрын
Hi ... in abnormal configuration how is is air vented outboard .... as air is continuously introduced through the air conditioning duct?
@poh3 жыл бұрын
The air conditioning air is added only to cool down or regulate the temperature because generally the blower or extract fault will be for these two reasons only. So once its under control the flow is automatically adjusted and the fault also disappears.
@kedarpandya43 жыл бұрын
@@poh Thank you
@kedarpandya43 жыл бұрын
Hi Can u please confirm if the air that goes to Cargo Underfloor eventually is exhausted overboard through the outflow valve?
@poh3 жыл бұрын
Cargo underflow air is recirculated back to the avionics bay.
@kedarpandya43 жыл бұрын
Thanks
@komalattri64163 жыл бұрын
@@poh can u plz share related pdf
@poh3 жыл бұрын
Which related pdf?
@komalattri64163 жыл бұрын
air for cargo ventilation is coming through avionics equipment ventilation through extract fan...???
@EdisonNenger917 жыл бұрын
awesome!! thanks!! it's very helpful!!
@poh7 жыл бұрын
You're welcome!
@bazokazoro45633 жыл бұрын
Sir you said when extract override both fan continue running , are there an exception?
@poh3 жыл бұрын
Exception as in?
@bazokazoro45634 ай бұрын
still waiting for the answer ! +in close conf. when extract fan inop (override) where the extracted air overboard ?
@poh4 ай бұрын
Extract fan is never inop, it's fail operational. Nevertheless even if it stops, it doesn't mean it blocks all the air. Air keeps circulating.
@bazokazoro45634 ай бұрын
Sorry sir once you put the p/b on override the system reverts to close conf. with extract fan fail and APU inop there is no circulation agree!@@poh
@sq84094 жыл бұрын
Are you A320 type rated?
@poh4 жыл бұрын
Yes
@dukhishyamsahoo19767 жыл бұрын
your video is very helpful. .
@poh7 жыл бұрын
You're welcome!
@mukeshalank77634 жыл бұрын
Dear sir why some pushbuttons switch inn a320 having 2 dots.?
@poh4 жыл бұрын
If no alert or system status is required, then two grey dots replace the fault light etc.
@torrero01014 жыл бұрын
Hi, what is the different between Avionic bay and avionics equipment?
@poh4 жыл бұрын
Avionics bay is the common area between the zones. Avionics equipment specifically refers to the zone where computers are kept.
@torrero01014 жыл бұрын
@@poh Thanks very much. Another one. Regarding Abnormal operation. when you override both pushbutton switch Blower and Extract, why the extract fan is still runnning?
@poh4 жыл бұрын
The pbs are mere method to reach a certain configuration and the override is not directly linked to the fan, the override is to do with overriding the capability of the aircraft to change configuration and keep it in one spot.
@torrero01014 жыл бұрын
@@poh Thank you
@mohammadalajmi86124 жыл бұрын
Why incase of smoke outlet not fully open to push more air outside
@poh4 жыл бұрын
It may lead to loss of pressure of the aircraft immediately.
@puneetkaur91635 жыл бұрын
Pls give one example of temp. below ground threshold ?
@poh5 жыл бұрын
When it is cold on the aerodrome.
@puneetkaur91635 жыл бұрын
I mean numerical value example.I am confused will it be less than 12 or 9 depending on trend of temp increasing or decreasing OR btn 12 and 9 ?
@dglouis43544 жыл бұрын
what is 'in flight threshold'??
@poh4 жыл бұрын
A value used to assume aircraft in flight conditions! Whenever aircraft take off power is set its considered to be in flight for avionics ventilation system.
@Bforbravo3134 жыл бұрын
Thank you very much
@ferasalloush8 жыл бұрын
Thanks very good
@poh8 жыл бұрын
You're Welcome! :) Stay tuned in and subscribed for regular updates! :D
@flykaranvir8 жыл бұрын
Planes Over Head
@arunimaprem82887 жыл бұрын
Your videos are very very helpful! Thank you so much :)