I cannot express how thankful I am to you. My system shut down in NC during this 100° heat wave. Turned out the system in the attic was filled with water. I sucked out the water with a shop vacuum and it fired back up again with no issues. Tomorrow I will cut the evap pvc pipe, clear it out amd use pvc unions to reconnect it. Sir, you saved me a fortune. Thank you so much!!!!!!!!!!!
@justinphebus67326 ай бұрын
Reerrr
@kevinallison2227 Жыл бұрын
Best most complete video on HVAC troubleshooting by far!!! Thank you! Very informative and professional!
@douggys27 ай бұрын
Thank you for the tutorial, my A/C went out on one of those 100 degree days, my HVAC guy was out of town and I would of had to wait three days til he got back. I don't trust just call any repair services from my experiences with dishonest or over charging, so I stick with one company I trust, anyways I changed my capacitor on condenser, still didn't work, when you mentioned checking the thermostat by jumping the connectors nothing happened, then I went up into the attic (100+) I found the condensation safety switch in the drain pan was a little tweaked, realigned it and cool air was back, thank you very much you saved me a lot of money and being miserable for days in 100+ temps!!!!!
@soccerplayahershey5 ай бұрын
Never would've guessed something as simple as the condensate safety switch. Used my shop vac to remove the water from the pan and the unit instantly kicked on! This video was very helpful. Thanks! 👍👍
@luberger44405 ай бұрын
Thank you AC Service Tech and @soccerplayahershey. Had issue with thermostat not being on, replaced battery and still nothing. Water in pan was at the top and could see damp areas nearby. Wasn’t comfortable around the system especially with water and electricity but after reading @soccerplayahershey’s comment I went down, turned circuits off and shop vac’d the water out. Success! Thank you so much, I have air flowing on this hot day in August. Just to show a woman in her late 60’s can make things happen. Very happy.
@marvinlaird19717 ай бұрын
I couldn’t find a video to where the inside blower and the outside unit wasn’t working and I almost didn’t watch this video but I’m so glad I did, I started by using a jumper wire at the thermostat and nothing so I checked the control board and remembered I use to see a green led light on the board, so I pulled the 5amp fuse and BINGO! I already had an extra fuse on hand. Thanks for the video!
@Itsjonny23 Жыл бұрын
You saved me a couple hundred bucks. Thank god for people like you
@romarro46162 жыл бұрын
Thank you for the time you spend every day making these videos
@kryknow77535 ай бұрын
This is by far the best channel I have found on ac repair. Very thankful for this information!!!!!!!
@conniefleenor95403 ай бұрын
Oh my gosh. Thank you! I had plumbers in my attic a few days before I noticed my AC wasn't working. Your advice to check for a loose door was spot on. I'm sure they bumped it loose. You saved me so much frustration and a service call.
@acservicetechchannel3 ай бұрын
Glad it helped!
@georgeclooney91644 ай бұрын
Yo I've been stressing about my condenser shutting off for the past 24 hours. We had my gf's mom over yesterday for a labor day grill and the ac stopped working! I panicked and spent some time in the heat trying to figure out what could be wrong. i woke up today, hot, and worried that I would have to replace my entire unit for thousands of dollars...was about to call an AC company but decided to watch this video. When I got to the part about replacing the batteries in the thermostat I scoffed, but figured its worth a shot at least. There's usually an indicator that says low battery, but since you convinced me to try it, I changed them despite the lack of any indication of them being low. Imagine my relief and joy when I walked outside to a spinning fan in my condenser. Thank you sir, you probably just saved me from someone trying to scam me into buying a whole new unit. I've been laughing with relief since. Thanks for the video!
@kayjay9434 Жыл бұрын
Thank you for the 10 tips I just fixed my Ac with your help.
@kenrwall Жыл бұрын
Problem #5, was my situation. Your video saved me a service call and one day of 95 degree weather. Thank you very much.
@Drone953 Жыл бұрын
Watching from Toronto, you just saved me tons of money, did the trouble shooting turns out it was my thermostat wire that’s bad. I jumped it directly from my furnace and everything works ! Thanks for your help!
@horton69512 жыл бұрын
Number 1 problem for ac system not running after 30 years in Hvac business is condensing unit capacitor bad . 8 out of 10 summer service calls are capacitor .
@July4.17762 жыл бұрын
Capacitor replacement will become obsolete in the coming years.
@billy50322 жыл бұрын
@@July4.1776 Variable speed control boards will be the new capacitor for ac failures
@July4.17762 жыл бұрын
@@billy5032 yeah, and if they fail as often as a capacitor then someone is bound to make a lot of money.
@brayancrespo15172 жыл бұрын
We’ve been having a lot of clogged drains and condenser fan motors here in TX, and fuses that pop on residential Geothermal package units
@billy50322 жыл бұрын
Efficiency up ,reliability down ,repair expense up ,electric bill down.
@dansmego6952 жыл бұрын
That lightning bolt scared the crap out of me 😅 great video for people learning simple diagnostics on an AC!
@mikelroper7 ай бұрын
The tip about the switch was super helpful. Our A/C condenser dumps water into our sump. When I replaced the sump pump, I must have pushed water back into the system causing the switch to trigger. Although the switch is different and doesn’t have a reset, I was able to twist the switch allowing the water to drain and move back to the original position. The A/C started right up. Thanks for the great video!
@KenKopp-h2w Жыл бұрын
Very informative, not generic. I learn things that others don't say or go into more detail about. Thank you! and Kudos.
@acservicetechchannel Жыл бұрын
Glad it was helpful!
@filibertobarrera38392 ай бұрын
Thk you bud followed all ur tips and tracked it down,wife was weed eating ,she hit the two thin wires the red and white,it stripped them both and both copper wires were touching,checked fuse and it was burned.Thks again bud for making me look like a geniuos to my kids.❤❤❤
@IsabelGarcia-dn8it8 ай бұрын
Mine was problem 4! Thank you , saved me some money & time! It was 93 degrees outside in Texas today definitely needed that Cold AC
@Wesley97706 Жыл бұрын
Problem number 4 was mine, and thank you for educating me on that because you saved us a lot of money.
@dwajda Жыл бұрын
Video is excellent. Straight and to the point. Very clear.
@dougwolverton4325 Жыл бұрын
For me it was the fuse. It was 3a and I had a 3a. Started right up. So many thanks. And really liked how thorough it was. I have found and replaced capacitors before but not a fuse.
@Johndnguyen1982 Жыл бұрын
After spending figure why my smart doesn’t power. After seeing your video, fixed it. I love ppl like you making video like this for ppl like me no a handing man
@georgedavis37892 ай бұрын
Your videos are really saving a lot of people, a lot of money! Thank you!
@catieman Жыл бұрын
Great video! I had these symptoms and using the jumper wire technique to bypass the thermostat revealed it was the problem!
@moekazemian5 ай бұрын
Great informative video very much appreciated. My Tran AC stopped working a few days ago in the middle of high heat. Since I had changed the capacitor before, I rechecked the capacitor and found it to be the correct value. Checked the low voltage and found out that 27V is missing. It was challenging to find the source and it happened to be the safety switch on the swamp pump!!
@conwellboccia10046 ай бұрын
Excellent instructional video. The internal low voltage fuse was blown due to a rookie mistake on my part. The condensate pump wasn't working so I swapped it out without killing power to the entire unit (I did unplug the pump). Somehow, power found its way to the LV fuse & killed power to the main board. Now I have spare fuses but won't make that mistake again.
@kennethbearden92764 ай бұрын
Got a new Smart Thermostat and after installing everything went black, after viewing your video I was able to fix it myself. Was a $4 3amp fuse. Good info you have provided. Thank you
@rickydelima317 ай бұрын
You are an amazing human being! We're about to get a heat wave starting tomorrow and lost power to the thermostat. Thank you so much for making this video!
@jessicasneed8348 Жыл бұрын
Thank you for your suggestion on the 3 amp. My fiance didn't think about it when he was trying to get our AC to work. Your video is so very much appreciated.
@kcalderon039 ай бұрын
What kind of multimeter would you recommend for testing the capacitor and other AC components?
@psfgtech Жыл бұрын
Excellent video, I remember #9, fuse inside AC box, my repair friend left another fuse, but I have AC guy coming over. I'll save your video for next time
@jaresimo Жыл бұрын
My issue was the little 3 amp fuse which I figured out thanks to you but only after I replaced the capacitor. Thank you!
@nelsonpayamps14804 ай бұрын
Thank you so much. Hooked up a shop vac to the outside discharge pvc line. Lots of gunk in there. Got it working pretty quickly after that. Thank you.
@acservicetechchannel4 ай бұрын
Glad it helped!!
@CarolynAlexander-en7km7 ай бұрын
Thank you!! My son put a broom in the closet and shut off the light switch. I didnt even know it was in there! Appreciate this video🤗
@macoediv Жыл бұрын
it was the purple fuse for me. it only cost 5 bucks and saved me a few hundred. Thanks man.
@Mammas-lz9qr7 ай бұрын
Great video that has helped me twice today. Thank you for posting this!
@67gt500snakebite4 ай бұрын
I have a question I diagnosed my AC system from watching this Video. and figured out. It’s the thermostat. My system is combo AC & Heat. I jumped the Red & Yellow wire together. So now the AC and the blower are working but the AC compressor is not turning on. As to before I jumped the 2 wires together the AC unit would not turn on at all. So I am assuming that based on the video that I need to jump Red Yellow Orange and green together?? Any advice would be greatly appreciated
@bhen2056 ай бұрын
Although my problem was a bad contactor, this video helped me go through the troubleshooting procedures to narrow the problem. Thanks for the help.
@MrOttobot89 Жыл бұрын
You're videos are awesome! You explain everything thoroughly, but without getting long winded. I also love that you explain which terminals to test with the multimeter. Great job and thank you for your help!
@acservicetechchannel Жыл бұрын
Wow, thank you for your kind words and for watching our content!
@judyboygt38475 ай бұрын
Thank you for the video you save my life I live in florida and my ac went down at the middle of the night you save my life thank you so much
@MrsBuddevil7 ай бұрын
On a electric/gas unit.. Does the furnace need to have propane going to it in order for the ac to work in the summer time?
@She_Tried_It5 ай бұрын
If the condensate line is clogged and triggers the shut off, will just clearing the clog be enough? Or do you need to do something to reset the trigger switch? Mine was clogged, I cleared it, poured water down the drain and it stays clear, but the AC won't come back on. Originally, I happened to be walking by the hall closet where the unit is (1969 house) and I heard some clicking, shortly after the AC went off. So I checked the Safe-T-Switch, which I normally pour vinegar down 4 times a year - but hadn't in at least 3 years.
@searez7251 Жыл бұрын
I found out that my AC's problem was with #5, a weak battery at the thermostat. Thank you for the great content.
@acservicetechchannel Жыл бұрын
Thanks for watching!
@mattbrimble47108 ай бұрын
Thank you for the tips mine was the metal door button wasn't pushing all the way in I taped it put door back on and now sitting in a nice cool house ty so much saved so much money calling someone out here
@seckora Жыл бұрын
You saved me a bunch of money! It only cost me $1 for a 3 amp fuse once my AC went out. It went out because I wired the thermostat wrong but it at least is fixed. Thank You!
@davidsteinart Жыл бұрын
Thanks man! Tip number one solve my problem. I really appreciate the video!
@MsSonya68 ай бұрын
Looling for suggestion: AC unit went out and the capacitor was changed on the first service visit. Was told need a new unit but Choice warranty approved to change the compressor instead. Ok, compressor was changed yesterday and house back cooling. Here's the issue, the air filter needed to be changed so I head up to attic (turned off AC at thermostat) and changed the filter. Turn thermostat back on to cool, and the AC unit outside never kicked on. Checked breaker and everything and still does not come on. Any suggestions on what it could be? Serviceman cannot come back out until next week. 😩 Thanks in advance,
@jeannagiordano13547 ай бұрын
Thanks for sharing so much helpful information. We’re having trouble with our condensate line and excess condensation dripping from the air handler - We’ve watched several of your videos and noticed a condensate pump shown in this one. Do you have a video about the pump you are using and how you install it? Thanks!
@sisterginalavonne53064 ай бұрын
Thank You!! Its was #4 for me!! I was worried its too hot and humid in Fl.
@LearningVideos-ff7sq7 ай бұрын
This video helped me to solve my problem. Problem number one was the solution. Thank you very much
@northabbot7116 Жыл бұрын
I’m here wondering how to find my AC control panel? I live in Phoenix in a condo, there is no indoor furnace. AC unit is on the roof
@andrecummings133 ай бұрын
With my situation, I called the light company and come to find out a wire came aloose at the transformer. Now it runs perfect, and I think the Lord for that. Free service.
@mrc.tillsr74152 жыл бұрын
Fuse , breaker ,capacitor ,contactor ,thermostat are some issues or if it’s a heat pump low charge , good stuff I was just going to say common wire too
@shawnforan14712 жыл бұрын
Videos are always well done and informative. Great information for seasoned techs that want to refresh or new guys looking to learn.
@aleksjimenez15 ай бұрын
Thanks I follow all the the video and check every step and the door from rhe unit was a little open . Fit it... thanks
@DMS202314 ай бұрын
What would be common problems for BOTH indoor and outdoor units not running? I turned air off but forced fan “on” and it doesn’t blow. Outdoor unit never kicks on. Does the thermostat directly control outdoor unit or does that signal pass through the indoor unit first? Meaning, can a problem with the indoor unit (like a condensate drain) also cause the outdoor unit to not come on?
@LOUPED4 ай бұрын
You just saved me a chunk of change! Thank you 🙏🏼
@Samlol23_drrich2 жыл бұрын
As usual, the most clear concise videos. Great info. Thanks!
@douglieberman64067 ай бұрын
Just to mention I learned about the word tau , and the capacitor charges up and then discharges in 5 tau. ! 1 tau. 2. Tau. 3 tau. 4. Tau. and 5 tau The capacitor will start a motor up in 5 tau then the contact will close if I remember really well ! The capacitor and contact combination are a parallel combination in series with one leg of the motor or one hot wire!
@davem37892 жыл бұрын
Would you recommend changing capacitors or fan motors based on time (21 years) as a preventive measure?
@lanceestes59802 жыл бұрын
Check MFD on the capacitor. That’s how you test to see how what they are currently running at vs what they are rated for.
@rijudangol1980 Жыл бұрын
Thanks man
@fivetwothreex Жыл бұрын
Bad control unit, thank you so much. Bout to go crazy trying to figure it out!
@sothiram5107 Жыл бұрын
Your videos very informative. I have a bad 3amp fuse. Thank you
@stevehaver75457 ай бұрын
Thanks for the great explanation of possible issues.
@CurtisD19867 ай бұрын
My ac unit at this rental looks older than anything you've showed. Their is a pvp pipe coming out, but it's just ran down the side, and then parallel to the ground, down to a drain in my basement. Not scorching yet but it is almost 80 and ac unit won't work. Landlord said he will get someone out here tomorrow. Worst part is I absolutely can't sleep when I'm hot. I keep it around 65-67 when I'm going to sleep. 😪
@jymarse20896 ай бұрын
Thank goodness for you i cannot even begin to thank you god bless you
@ItsRiska7 ай бұрын
Both the inside unit and outside unit are running just fine. Changed the filters, cleaned the coils, replaced the batteries in the thermostat and still no luck
@martadiaz71328 ай бұрын
You are amazing!! Thank you!! I wish i would see your video before my Ac. Broken.
@FlemNmzzzz6 ай бұрын
Jumping the thermostat points revealed the flaw in my system. Thank you!!!! Subscribed w/notifications
@qianamays6679 Жыл бұрын
Thx. Safety was tripped
@GeneCarter-zh1of8 ай бұрын
I've gone through these potential problems and can't find out why the unit suddenly stopped. The only anomaly I found was all lights are out on my Honeywell HZ322 controller and it's getting power. Will a unit not start if the zone controller is dead?
@codysmith3280 Жыл бұрын
Thank you!!! For the info saved my Easter with this video you sir are my hero!!!
@FrankTravel-eh7xs6 ай бұрын
thank you for your expertise AC trouble shooting knowledge, I was able to resolve the problem and feel like I shaved some money,
@aaronlodwig23894 ай бұрын
Great video! Thank you!
@hajjajchami7053 ай бұрын
Thank you so much man for your videos
@yanyanwang6377 ай бұрын
Thank you so much. I followed the video and fixed it which was problem #3
@kaya29392 жыл бұрын
Any plans for a book in electrical troubleshooting? Appreciate your content !
@joshuarussell79552 ай бұрын
What type of wire are you using to jump
@joserobles71908 ай бұрын
Thank you so much for your help my problem bad phase in the thermostat
@KenT-mh6us Жыл бұрын
I had a new fan motor and capacitor replaced just over a year ago and am having the same issue. When I first turn on the cool setting, the compressor would kick on and try to start for about 5 seconds then shuts off. Only the fan would stay running. I need to shut off the thermostat and wait a few minutes to try again. Then on the 2nd attempt, the compressor would stay running and continue blowing cold air. Is it a possibility that the capacitor has gone bad in such a short time?
@JAKEJAKE-bc5dr Жыл бұрын
Excellent video! Very informative. Thank you
@vonroyale36615 ай бұрын
When your pregnant gf flips the emergency switch and enters into panic mode when the AC doesnt turn on 😂 this was gold! Thank you sir
@eacjones2 жыл бұрын
8:30 I tested a capacitor last year and it tested good but when I shook it, I could hear it. It was bad, but why? Thanks for the awesome video!
@timblack64226 ай бұрын
You helped loads! Thanks!
@Lions153 ай бұрын
You did not discuss about bad stepdown transfomer 24 v and what components affected.
@chrisgallardo90587 ай бұрын
Thank you so much! Fuse went out.
@Karla-yi5ld Жыл бұрын
On the thermostat why are there two numbers? In the daytime should it say DayTime or Run?
@dreemscargill9977 Жыл бұрын
Thanks for video it's really helpful.
@acservicetechchannel Жыл бұрын
Glad it was helpful!
@mrc.tillsr74152 жыл бұрын
Oh the nest the number #1 issue with those are the common wires not being connected at the time thermostat or at the air handler or period due off factory charge . I always check to see if common is connected, not recommended but I grab a little piece of wire and barely touch r and c to see a little spark (ounce again not recommended) keeps you from going in air handler attic up stairs etc …. You know common is connected SO I then hook it to the thermostat or connect it at the board air handler etc..
@streetfit9096 ай бұрын
Awesome video!
@joegarcia54 Жыл бұрын
Where does one find a brush like that to clean the tube
@alfredorivera288510 ай бұрын
Thank you so much you save the day today I am going to subscribe and recommend your channel
@Just4FunFishing10 ай бұрын
Thank you so much sir it was the float switch worked instantly
@ajmaldalili69062 жыл бұрын
Thank you very useful video
@MarioMartinez-tp4ne Жыл бұрын
You just saved me from having to call the hvac tech. Blessings upon you and your family. It was the thermostat, not the outdoor unit. Thank you.
@XV-logs Жыл бұрын
THANK YOU!
@xiaoy32 жыл бұрын
Hi! Thanks for this video. In the past couple of months, sometimes when we push the thermostat down a few degrees, it won’t trigger the on. It’ll flash “cool on” but the AC doesn’t turn on. I then turn off the system and then reset the circuit breaker. When I turn it on again it starts working. It doesn’t appear to be a condensate drain line problem as water isn’t backed up. Also, the unit is only 2 years old, got it installed a couple of years ago. Do you have a sense of what this could be? I don’t understand why it always works after resetting the circuit breaker for AC. (The breaker doesn’t appear to be tripped when I reset.)
@claudio3211 Жыл бұрын
Thanks so much for your information. Worked like a charm in my case and I'm a true novice.