Air Source Heat Pump Buffer Tanks explained - Kingspan Albion Aerocyl

  Рет қаралды 112,205

plumberparts

plumberparts

Күн бұрын

Пікірлер: 140
@PaulJones-t7w
@PaulJones-t7w 10 ай бұрын
A note of caution … if we want the heat pump rollout to be a success, they are going to have to deliver heat at a price that matches gas, preferably even cheaper. Therefore, to anyone thinking of installing a heat pump, PLEASE be very cautious about putting in a buffer. Unless you are able balance the flow rates very closely on each side, you’ll likely end up with the heat pump running hotter than it needs to, thus reducing COPs and making the householder’s energy bills higher than they need to be. You only really need a buffer if the circulation pump in the heat pump can’t produce adequate pressure for the (probably larger) property, or if you are feeding in more than one heat source, eg. a boiler backup. Defrost can be taken care of by leaving enough rads permanently on, or if that’s an issue, put in a volumizer in the circuit. Take a look at the excellent videos from ‘Heat Geek’ and ‘Urban Plumbers’ on buffer tanks to get the expert view on this.
@DanielTowers
@DanielTowers Жыл бұрын
Is the buffer tank still used when heating DHW or is it just used for central heating? thanks
@sammyb99
@sammyb99 Жыл бұрын
Isn’t it funny how for years we went back to “low water systems” micro bore plastic and small rads now we need the opposite for heat pumps 😂
@SkillBuilder
@SkillBuilder 2 жыл бұрын
James you are a genius, polymath and your brickwork ain't too shabby.
@plumberparts
@plumberparts 2 жыл бұрын
Haha! Yeah the brickwork is so good it felt like I was glueing it up! 😂😂😂
@garydulson9018
@garydulson9018 2 жыл бұрын
Rodger, forget his heat pump, I'm HEATAS part 4 use the thermal store with a coal fire! lol Sorry Jimmy! 🤣
@ciananmchugh410
@ciananmchugh410 2 жыл бұрын
Plumb the kaunt out of er
@georgepop474
@georgepop474 11 ай бұрын
Hi James Can you do a full video about the wiring of this system please? I’m a bit confused about the 3 way valve ,because it comes with 5 wire and the heat pump doesn’t accommodate that . The heat pump has only 3 connections on the terminal block so I’m thinking that a diverter valve will do the job So I’m not sure how it works 😅 Thank you
@corkfly1
@corkfly1 5 күн бұрын
Nice to see an immersion heater on the tank! how much is electricity?
@calderjack7818
@calderjack7818 5 ай бұрын
Excellently presented, I wish I had a fraction of your knowledge
@rickbean2170
@rickbean2170 2 жыл бұрын
Congratulations on being nominated as Influencer of the Year 2022. Do a video and ask uour followers to nominate you. Best of Luck
@UnderwaterADV
@UnderwaterADV Жыл бұрын
I'm finding sourcing such a cylinder impossible, is this the biggest one you showing? want to let me have this one for an install at my property, you can then review how well it actually installs. Or maybe just let me know where I can buy this in the UK.
@davecodling1
@davecodling1 2 жыл бұрын
I moved into a property with a Therma V it only has a small buffer tank. But also has a Combi attached. And seems to use this for hot water. The air source pump rarely kicks in. Controlled by an LG controller in loft. The plumbers I've had to look at it dont understand heat pumps. So I'm a little confused how its actually meant to operate.
@oliversmith8220
@oliversmith8220 2 жыл бұрын
Just the quick question, in the summer when the central heating is not needed or defrosting of the heat pump, is the hot water in the buffer tank therefore wasted?
@jamesg2987
@jamesg2987 2 ай бұрын
Why the hydronic separation between heating and air source heat pump. Surely the heat pump circulator pump is good enough to pump round the radiators/underfloor heating?
@Chrominance87
@Chrominance87 2 жыл бұрын
Your looking a lil like Roger Bisby these days. Great video.
@toshy584
@toshy584 10 ай бұрын
I was fooled by the thumbnail into thinking it was installed outside (outstalled?). I was looking into this as our house is so small. If I build a wood or brick shed for it outside. Should be ok right? Be the same as 1 in a garage. In fact could I put both in said shed?
@paulhutchinson323
@paulhutchinson323 2 жыл бұрын
Most heat pump manufacturers offer pre plumbed cylinders with built in buffer. The leading brands have inverter driven compressors so short cycling isn't an issue, a buffer is mainly used to maintain minimum water volume for the defrost.
@hvacdesignsolutions
@hvacdesignsolutions 2 жыл бұрын
They only turn down to 25-30%, so the larger models still need a buffer
@paulhutchinson323
@paulhutchinson323 2 жыл бұрын
@@hvacdesignsolutions not ours, we only require a buffer (volumiser) if you can’t meet minimum water volume in the open circuit for defrost . A buffer can be useful in larger installations where you have multiple heat pumps cascaded.
@EdthePlumber
@EdthePlumber 2 жыл бұрын
@@hvacdesignsolutions then the heat pump is oversized?
@geoffaries
@geoffaries 2 жыл бұрын
The buffer is also useful if you don't want to replace the heating flow and return e.g. if its microbore, the heat pump requires a minimum flow rate which may not be achievable if the ASHP is connected directly to the heating circuit.
@kierenhudson6331
@kierenhudson6331 Ай бұрын
My house has a gas combination boiler. I want to do away with the gas supply altogether. Would this be benefiting me in terms of having just an electric bill instead of both?
@m0aze611
@m0aze611 Жыл бұрын
This is a great vid as Im not quite there yet and find quite a lot of information that can be contradicted depending on what forum Im on. I surmise that a buffer may not be required depending on the system design. Thank you regards Mike
@adrianred236
@adrianred236 8 ай бұрын
I watched this for the same reason. Urban Plumbers says the opposite, he tries to leave buffers out where possible to increase efficiency. I think the trick is to not oversize your heat pump so that it won't be cycling.
@vedrandujmovic4205
@vedrandujmovic4205 2 жыл бұрын
Hi James, great video! Will you doing some video about therma V mono block?
@Harry_Mending
@Harry_Mending 10 ай бұрын
Any reason why you couldn't run this off a system boiler while waiting for a heat pump upgrade?
@johnhine1007
@johnhine1007 Жыл бұрын
Just a quick observation, why you sticking your flow setter on the flow pipe, LV stipulate it on their manufactures instructions that it be fitted on the return pipe.
@gibbodive140
@gibbodive140 Жыл бұрын
It is a shame they have put all this effort in and fitted a prehistoric drain valve at the base of the cold water feed (pet hate !). Why not fit a full bore valve with a 3/4 male connection to allow fast draining and more importantly an perfectly located pressure test point when servicing ! Rather like the Megaflow ? I absolutely agree with the point made about fitting the combi valve at a high point...
@BakedTuber
@BakedTuber 3 ай бұрын
Does this mean the buffer tank should be kept hot 24/7? Or does it all stop when the system stops calling for heat?
@rafaltomaszewski5175
@rafaltomaszewski5175 2 жыл бұрын
Hi. I have a question, We have a tank for DHW with a coil and buffer tank underneath without a coil. There is a heat element but it is not connected to the box, only DHW water tank its heat element is wired up and connected to the box and it is used for disinfection of the tank, weekly. Now when the temperature outside is -4 , LG THERMA V 9kW heat pump can’t cope. It is using 6 plus kW of energy , water temperature outlet 41and inlet 30max ( 30 ‘C is going into the rads and in the house is 17’C) . Pump can only generate 40’C because the rec pump to the radiators is returning 20’C back to the buffer tank only so on. Every 10-15 mins the pump is defrosting so by the time the defrost cycle finish temperature in the buffer tank drops to 20’C . How I can help the heat pump to generate higher temperature? Im freezing. If I will use that heat element in the buffer tank which is not wired up , will I loose my government grants for the installation of the heat pump? This is second sezon, we we promised that this is better than our bosch boiler which we had before. Thank you in advance. Rafal
@LewishamPpleB4Profit
@LewishamPpleB4Profit 2 жыл бұрын
What's the price of the combined unit? I couldn't find it when I searched - I just got heat-pump-ready cylinder when I searched for Albion Aerocyl Buffer.
@myatix1
@myatix1 2 жыл бұрын
I have 150m2 of a 100% UFH should I use a buffer tank? There seems to be conflicting options about this! The Heat Loss is 38w/m2 and has a large thermal mass. (100mm slab)
@drummerboy6178
@drummerboy6178 Жыл бұрын
Can someone explain what this system does, is it storage tanks for hot water, and is it used for infloor heating or rads on the wall...it looks very expensive as compared to a basic 240 volt electric hot water system...thanks
@NickAskew
@NickAskew Жыл бұрын
I'm curious why you'd need an immersion heater in the buffer, is that just to backup the heat pump in case it fails or is it to backup the heat pump for cold weather?
@Harry_Mending
@Harry_Mending 10 ай бұрын
Could use it if you have solar panels?
@NickAskew
@NickAskew 10 ай бұрын
@@Harry_Mending Since this video the same channel has kind of explained a few more things. One seems to be that the use of an immersion heater means you can bring the buffer to a usable temperature and then fall back to the heatpump in cold weather. This is because trying to get a really cold buffer up to temperature with a heatpump alone in really cold weather might just take too long, but if the buffer is pre-heated then the heat pump can keep up.
@Harry_Mending
@Harry_Mending 10 ай бұрын
@@NickAskew interesting, thanks. Do you know if there's any reason that this couldn't be run off a gas-fired system boiler until a heat pump can be installed?
@NickAskew
@NickAskew 10 ай бұрын
@@Harry_Mending In the Netherlands, where I live, combi/hybrid gas/heat pump systems are gaining traction. I'm not a big fan but what it means is that a heat pump can do most of the heavy lifting and then when it cannot cope, the gas boiler is fired up instead. I believe they are usually retrofitted to an existing gas boiler. I'm sure this is not the only country to use them, but my concern is that sooner or later you will need to replace the gas boiler and then if the heat pump is undersized you will need to replace that too.
@n2obob
@n2obob 2 жыл бұрын
The buffer is more important as the mixing point for a fixed flow system and a variable system. Just like a big low loss header. It will also stop short cycling of the heat pump.
@ajones8699
@ajones8699 2 жыл бұрын
Heating element in the buffer tank😂🤣😂🤣perfect👌
@KEENY475
@KEENY475 2 жыл бұрын
confused with the positioning as pointed out of the immersion heater (in buffer tank) -may as well stick it in a radiator
@dononebullen
@dononebullen Жыл бұрын
Help I need to understand bivalent systems I have airsource thinking if teeing in a 3 port valve for rayburn in cold months
@jethrohealy3277
@jethrohealy3277 2 жыл бұрын
I would suggest another automatic bypass valve between the flow leaving the buffer to the return on the buffer before the 2 port zone valve.
@tombutler4881
@tombutler4881 11 ай бұрын
Looks like a great system. I am puzzled why there is no circulation pump on the Heat pump side of the circuit....can anyone explain?
@8skellerns
@8skellerns 10 ай бұрын
Isn't it built into the heat pump itself?
@steviepower9194
@steviepower9194 2 жыл бұрын
At first i thought you had made a climbing frame for your kids in the garden mate. That thing is huge.
@handyandy6050
@handyandy6050 2 жыл бұрын
Apparently most heat pump installations are installed in Semi Detatched houses. One semi is lived in, the other semi houses the heat pump heating system.
@David-bl1bt
@David-bl1bt 2 жыл бұрын
🤣
@rcmast3rtract0rking
@rcmast3rtract0rking 2 жыл бұрын
Indirect has coil in it?
@98067100
@98067100 2 жыл бұрын
How do they get round the need for a spring loaded valve on unvented to close the valve to prevent the cylinder continuing to heat up. Are they just fully reliant on the cylinder stat, safety cut out and then the tprv operating. What happens if the 3 port passes???
@LewishamPpleB4Profit
@LewishamPpleB4Profit 2 жыл бұрын
The valve is pointless on anything heating water. The heat pump isn't going to get anywhere near boiling and any decent gas boiler has a proper temperature control and an overheat cutout. The spring loaded 2 port valve is just a scam to sell more 2 port valves. Viessmann got dispensation to cut them out.
@ponchloz
@ponchloz 2 жыл бұрын
It isnt a mid posistion valve, its a divertor that motors open for HW call and spring return to Ch. Rest posistion is open to CH.
@jmrprecisionplumbinginc6238
@jmrprecisionplumbinginc6238 4 ай бұрын
Send me the links for the one with return line please, thanks. JMR PRECISION PLUMBING INC
@kentbrady3364
@kentbrady3364 10 ай бұрын
What does this storage tank and its installation cost? Could one recover that cost in a life time?
@LeiChat
@LeiChat 2 жыл бұрын
Probably better recommending the Heat Geek channel, rather than Skill (aka F.U.D.) Builder. ;)
@thesilentgamer77
@thesilentgamer77 11 ай бұрын
I heard that having one of these could cost more in electricity. They are noisy as well. But I would be interested in hearing any thoughts on this matter and if anyone here has an ASHP installed. I am considering having one put in.
@gazdkw82
@gazdkw82 Жыл бұрын
This is probably a daft question (I am new to the world of heating systems), but can you integrate this into an existing combi boiler set up?
@stevesidwell2364
@stevesidwell2364 Жыл бұрын
Yes but you would have the combi boiler as a ‘backup’. I.e if the outdoor temp drops to a low temp the boiler would kick in and boost the system where the ASHP may struggle
@charliefox6987
@charliefox6987 Жыл бұрын
Great vid mate. With the roll out of heat pumps Do you think it’s still worth doing a gas course ? I’ve stuck a deposit down for may but I’m in two minds! Would be great to hear your feedback 😊
@johnhine1007
@johnhine1007 Жыл бұрын
Ive trebled and on some occasions even quadrupled my money than doing boiler swaps, lets be honest with each other were in this industry for the money NOT the love of the game. you have to speculate to accumulate, get yourself on the course.
@charliefox6987
@charliefox6987 Жыл бұрын
@@johnhine1007 hi John are you able to explain how it works with ‘gas improver/newly qualified’ so I assume you shadow some one for a duration ?
@johnhine1007
@johnhine1007 Жыл бұрын
@charliefox6987 there's no gas at all to worry yourself about, apart from maybe disconnecting the odd gas boiler, you do need, however, a basic understanding of heating systems, I've literally been re-piping heating systems from scratch probably a day extra in work and give it a hot chemical flush. I'm not 100% certain, but I'm think you may need to be part of an accredited organisation, i.e., Gassafe or similar and have a few years' experience in the trade to sit the A.S.H.P course don't quote me on it though. My advice would be to ask the training provider. But the money on the A.S.H.P grant scheme certainly outweighs those who fit boilers on the free boiler scheme.
@leonidasking7502
@leonidasking7502 2 жыл бұрын
Skill builder, heat geek beef was too funny
@plumberparts
@plumberparts 2 жыл бұрын
That it was!
@plumberparts
@plumberparts 2 жыл бұрын
@@leonidasking7502 thanks so much man.
@Sparks1Plumbers0
@Sparks1Plumbers0 2 жыл бұрын
@@leonidasking7502 Don't go telling him that.... he'll send you an invoice for his services. 🙄 Though he does accept Beer Tokens to help pay off his bar tab. 🤣
@martynbuzzing3327
@martynbuzzing3327 2 жыл бұрын
Considering the cost of fuels and how much more the are tending to go, would a tanked water heater be a better deal? I watched you explain about running hot water through a return but I can't do that with a gas fired combi heater...
@bovnet
@bovnet Жыл бұрын
A flat plate heat exchanger for DH would make the whole thing so much simpler
@andytrewin
@andytrewin 2 жыл бұрын
It's "GI-NAGEROUS" I will have to take my ceiling down!!! or should I be installing this in the garden??
@Sparks1Plumbers0
@Sparks1Plumbers0 2 жыл бұрын
Nah, it's not that tall. James is just a short ass, so stood next to it it just looks ginormous. 🤭
@Mastergas-r7n
@Mastergas-r7n 6 ай бұрын
Brilliant 💪🏻💪🏻
@grumblewoof4721
@grumblewoof4721 2 жыл бұрын
When you look at the all the stuff you need for a heat pump solution compared to a compact Gas boiler or electric heating solution it is no wonder people are not rushing to install them. It looks like some industrial installation from a Star Wars set. Cost and noise ? Do they really work ? The solutions in the future need integration into new buildings. i.e. underground heat exchanger pipes laid with foundations, air pumps inset in walls and integrated with solar electric and water heating and wind turbines built into roofs.
@richardlewis5316
@richardlewis5316 9 ай бұрын
I had a heat pump salesman visit me and I told him I wanted to keep the Combi boiler for hot water and have the heat pump to do the radiators with assistance from the Combi when needed. He got up and walked out saying it can't be done. I won't print here what I thought of him!!
@LiFeS2ShOrT2DiE
@LiFeS2ShOrT2DiE 8 ай бұрын
Bosch do hybrid systems that run alongside an existing Combi gas boiler .
@timhull8664
@timhull8664 2 жыл бұрын
Old houses.. had an airing cupboard, new houses, have an airing bedroom!
@matthewmcmullan9669
@matthewmcmullan9669 2 жыл бұрын
That tank is huge, I'm assuming that's for a large 5 bed house not for a 2 up 2 down
@mrbachittarsingh9243
@mrbachittarsingh9243 Ай бұрын
I have one in my studio flat.
@jamesfortune5119
@jamesfortune5119 2 жыл бұрын
And you just fill up and put normal central heating inhibitor in the system and through the primary’s for heat pump I presume m8?
@aleksandrsloskutovs5524
@aleksandrsloskutovs5524 2 жыл бұрын
if youre going to get a heatpump might as well get the vaillant one. vaillants got the best heatpumps, might have issues getting them but worth the trouble. dont cheap out on the samsung/lg/grant shit
@CrowdControl2K8
@CrowdControl2K8 Ай бұрын
I am a self employed gasman in Central London. These are not going to fit in like 80% of the the flats and house's that I go in. There is no space outside for this size of unit.
@JohnnyMotel99
@JohnnyMotel99 2 жыл бұрын
Where was the explanation why the buffer negates fitting larger rads?
@nigeldavies6573
@nigeldavies6573 2 жыл бұрын
It doesn't. If anything you'll need bigger rads as using a buffer reduces efficiency due to the heat pump needing to run hotter. Manufactures are introducing buffers as most engineers don't know how to design systems correctly. Having a buffer ensures the heat pump works even on a badly designed system.
@MarvinofMars
@MarvinofMars 2 жыл бұрын
I have Juile 500LitreThermal Store Solar 1 buffer tank, I did have an air source heat pump order then all grants got cancelled so ended up going for an oil burner. So oil as the primary heat set at 35c-45c, but I can by pass this and run the heat of 2 boiler Stoves 11KW, vented with a metal over flow tank due solid fuel heating. Then a pressured heating comes of a high and low tapping's , to a plate heat exchanger this supplies toe the UFH, It runs at 65-80c so in modern house it is 2-3 days before you need to fire up at stove again. As the buffered water warms the UFH loops. It is hocking how many plumbers are unaware of how these systems work. After halting no less 12 plumbers on my self build I completed the work myself, being and engineer I was ok with this and then got all systems inspected and signed off. Buffer is vented and the heating pressuriesed
@David-bl1bt
@David-bl1bt 2 жыл бұрын
That's because you are using "plumbers" instead of " heating engineers"
@erbterb
@erbterb Жыл бұрын
Not enough buffer. A house needs at least 2000 liters of stored warm water. It is the bragging piece when you drink beer with you friends. 1000 liters is needed just for your teenage daughter, you get five liters to wash your face and 995 liters are for proper buffering. A more important question is if the houses are properly insulated and have double or triple glass windows, otherwise you are burning for nought.
@laurie8580
@laurie8580 2 жыл бұрын
Hold tight
@plumberparts
@plumberparts 2 жыл бұрын
Thankyou!
@peternicholson4311
@peternicholson4311 Жыл бұрын
Excuse my ignorance but how does the hot water get to an upstairs shower if the tank is downstairs
@_Dougaldog
@_Dougaldog Жыл бұрын
Cylinder is unvented, working at same pressure as mains cold water feed.
@digitaria
@digitaria 5 күн бұрын
You don’t get hot radiators with heat pumps. Where is the heat element for the main tank? Legionella protection for low temperatures. Buffer tanks for system volume so always make sure you consult the design. Nice tanks but loads of question marks.
@David-bl1bt
@David-bl1bt 2 жыл бұрын
It appears that temp relief valve is faulty such that the cylinder has clearly melted (@ 10:18 ) Resulting in the leaning behemoth of Albion😂
@stephenpeat3885
@stephenpeat3885 Жыл бұрын
Our neighbours moved to a new house with a heat pump he was not happy with the hot water temperature with a max temp of 52 degrees he had a small gas boiler fitted to bring the temperature in the cylinder to 65 degrees. He also noticed in older houses the heat pump cannot can deliver a home temperature of 20 degrees so the gas boiler boost help deliver the 20 degrees temperature especially when outside temp is below minus 8. I believe older houses will still need a small booster boiler on top of an heat pump.
@PeterUn-h1i
@PeterUn-h1i 8 күн бұрын
Golly it's big , wheres that going to go on your average terrace house or flat
@davecavaghan7889
@davecavaghan7889 4 ай бұрын
what happens when you haven’t got room for that massive tank,
@dansmith436
@dansmith436 2 жыл бұрын
They are great ... When you have an Ac that can take the height 😂
@malcolmstead272
@malcolmstead272 2 жыл бұрын
No room for all that in my second floor flat.
@scottpeters8142
@scottpeters8142 2 жыл бұрын
No need to increase radiator sizes? Lower mean water temp requires larger surface area, unless your lucky enough to have hugely oversized radiators, turning the flow temp up will just reduce its efficiency
@timcartwright4532
@timcartwright4532 2 жыл бұрын
Yes...lets see if he has the intelligence to reply to an obvious statement...engage brain motor mouth !
@rustyshakleford5230
@rustyshakleford5230 2 жыл бұрын
We only use all natural plumbing materials for our home. Instead of burning fossil fuels or using refrigerants to heat our water we use natural solar energy to heat our water. Instead of cast iron or vinyl based plastics we use hollowed out logs for our DWV lines and pig or cow intestine for our water supply lines instead of PEX or copper which are both very energy intensive to make or recycle. If we all do our part earth might last another 50 or even 100 years! You should really look into the Viega all natural piping line of products. I get some people will be turned off drinking water that comes through an animal intestine but they sterilize them before they are vulcanized into pipes.
@maximuswong3092
@maximuswong3092 2 жыл бұрын
It's disgusting that you would harm our animal brothers just to harvest their organs for your plumbing. I've chosen not install any form of plumbing in my house to save the environment, infact by shitting on my vegetable patch it helps it grow.
@rustyshakleford5230
@rustyshakleford5230 2 жыл бұрын
@@maximuswong3092 we only use aborted fetuses to fertilize our garden.
@David-bl1bt
@David-bl1bt 2 жыл бұрын
@@maximuswong3092 good for you, a true environmentalist. BUT WAIT.... What enviironmeltally friendly device are you watching this video on ?🤔🤔🤔🤣
@maximuswong3092
@maximuswong3092 2 жыл бұрын
@@David-bl1bt iPhone 14 pro max
@eddyr3691
@eddyr3691 2 жыл бұрын
@@maximuswong3092 What have you done with your old iPhone 13 pro?
@Thetyrerepairer
@Thetyrerepairer 2 жыл бұрын
Where would the average home owner put that monstrosity ?
@drood78
@drood78 Жыл бұрын
in the attic? i can fit about 10 of those and still have plenty of room
@martynbuzzing3327
@martynbuzzing3327 Жыл бұрын
An emersion heater? Seriously? I'm guessing in an older house that emersion heater would be perminatly on. Sorry not convinced.
@Divine_Evil
@Divine_Evil 2 жыл бұрын
Why do you need a tundish?! The plumbers here doesn't even know what that is.... I have a drain next to my boiler, just a normal Gardena hose adapter and a hose should be enough to divert the water to the drain...
@eddyr3691
@eddyr3691 2 жыл бұрын
So you can see the failure/water passing is occuring.
@richard8303
@richard8303 2 жыл бұрын
It’s also safety device/ air break incase termination is blocked, although the design is terrible and generally cause loads of property damage
@susanpritchard6164
@susanpritchard6164 Жыл бұрын
All that was an advertisement for Albion cylinders from the comments it just threw more mud in the water absolute joke who in there right mind would have that lot installed in there house or flat the cost never mentioned weight implications loads to go wrong in the future all to save 300 pound a year when you can just have a small combi boiler perhaps you can tell the subscribers when they sell the 1st one and how much it cost 😂😂😂
@johnh1872
@johnh1872 2 жыл бұрын
It's huge compared to my 5 year old boiler. In future I'll go for a hydrogen ready boiler.
@LewishamPpleB4Profit
@LewishamPpleB4Profit 2 жыл бұрын
You'll be waiting a long time for that!
@johnh1872
@johnh1872 2 жыл бұрын
@@LewishamPpleB4Profit . I'll wait. The current gas distribution network is worth billions. It will be utilised. I won't be buying a heat pump.
@David-bl1bt
@David-bl1bt 2 жыл бұрын
Very unlikely, hydrogen is extremely costly & inefficient to produce.
@johnh1872
@johnh1872 2 жыл бұрын
@@David-bl1bt . U can already buy a hydrogen ready boiler. Heat pumps aren't suitable for the majority of UK homes . Natural gas will still be used till hydrogen is viable. Relying on solar and wind is a big mistake. It will take decades to build enough nuclear capacity.
@nealm1814
@nealm1814 2 жыл бұрын
@@johnh1872 Hydrogen will never be economically or practically viable for domestic heating. Making green hydrogen to burn in homes would take 6x the number of wind turbines compared to heating the same number of homes using heat pumps.
@timhull8664
@timhull8664 2 жыл бұрын
Stick the outside underground in another country.
@richardlewis5316
@richardlewis5316 14 күн бұрын
I would like to install a heat pump to supplement my current gas combi boiler. The heat pump heats my house at low temperature but if I want to warm it quicker I switch to the combi. I do not want a bl***y great tank in my house. Give me this system please. Why do the heat pump evangelists want to get rid of a gas boiler?
@dimitar4y
@dimitar4y 2 жыл бұрын
crazy brits, they hate aircons but they put em in their basement to warm up their water!
@matthewmcmullan9669
@matthewmcmullan9669 2 жыл бұрын
The uk isn't warm enough for Aircon
@dimitar4y
@dimitar4y 2 жыл бұрын
@@matthewmcmullan9669 heat waves. you kidding??
@matthewmcmullan9669
@matthewmcmullan9669 2 жыл бұрын
@@dimitar4y we get hot days for a week or two that's it, we don't need to run expensive Aircon units
@seanjay886
@seanjay886 2 жыл бұрын
Oh no. Skill builder doesn’t have a clue about heat pumps. He’s a builder with opinions. That are not correct
@Displays.1234.
@Displays.1234. 2 жыл бұрын
What a totally disgusting mess.... And how much power does it take to run all the time, And you have to have back up power to per heat the water, and a extension to fit it in.... And a constant fan noise in the background, All fan's proreduce noise....no what people try to say....
@paulhutchinson323
@paulhutchinson323 2 жыл бұрын
You are so wrong on every point you made, there is still so many untruths surrounding heat pumps, we need to educate everyone to dispel these misconceptions
@drood78
@drood78 Жыл бұрын
AKA you're to poor to buy a heatpump.
@toffeetheshowjumpingshihzu
@toffeetheshowjumpingshihzu Жыл бұрын
Misleading name of video!!!!!!! Should be about buffer tank NOT INTEGRATED BOILER!!!
@mike-ology22
@mike-ology22 2 жыл бұрын
Kingspan are a rip-off
@SME_Ste
@SME_Ste 2 жыл бұрын
Why, do they take your dosh then give you something less than what you've paid for? How can anything be a rip off if someone gets the price of a piece of equipment and is happy to pay. If it too expensive, a normal person would look at something else.
@mike-ology22
@mike-ology22 2 жыл бұрын
@@SME_Ste They took all government subsidies for solar thermal, which we pay for as taxes. Charged enormous rates to have it fitted. Then, when it becomes cheaper, they sold it to the Germans. They sold insulation that wasn't fit for purpose for the grenfell tower. We had to do bribery courses and were told they would be in the news. Later that night the story come out that their insulation shouldn't have been installed in high rise buildings. I done site work on flats that has the insulation on all of them. Apparently there was something dodgy going on with the fire report and the staff were making jokes when engineers questioned if the insulation can be used above 15m. They don't offer proper training to employees who service cylinders and solar thermal. Customers being overcharged by the company due to not training staff in the office. High turnaround of employees. Making customers feel bad during covid for not having the cylinder serviced. Charging £200 per cylinder service to cover a 25 year warranty. Had a leaking tundish for 2 years until I forced them to change it. I solved a problem with their internal expansion vessels where the bar inside the cylinder holding the baffle was bent. Assuming it may have been driven to the plot on site using a forklift laying the cylinder on its side. I couldn't work for them because they just care about money, nothing els3
@evanleebodies
@evanleebodies 2 жыл бұрын
I'm still none the wiser after your explanation, back to Skillbuilder for me.
Heat Geek Gives His Verdict on John’s Nightmare Heat Pump
35:46
Skill Builder
Рет қаралды 705 М.
Let's Be Real About Heat Pumps!
15:13
Electric Vehicle Man
Рет қаралды 236 М.
My scorpion was taken away from me 😢
00:55
TyphoonFast 5
Рет қаралды 2,7 МЛН
Une nouvelle voiture pour Noël 🥹
00:28
Nicocapone
Рет қаралды 9 МЛН
How big a heat pump do you need? A simple Rule of Thumb.
17:40
Michael de Podesta
Рет қаралды 103 М.
Air Source Heat Pump Installation - Viessmann Vitocal
15:47
Loving Plumbing
Рет қаралды 4,9 М.
Installing Primary Pro insulation for an Air Source Heat Pump
6:11
Are Buffer Tanks Required For Air Source Heat Pump Systems? #podcast
27:02
Renewable Heating Hub
Рет қаралды 9 М.
Air Source Heat Pump Owner's Experience 5 Years On
33:46
Skill Builder
Рет қаралды 314 М.
How Developers Are Ruining The Heat Pump Market
20:28
Urban Plumbers
Рет қаралды 137 М.
SHOCKED This Heating System NEVER WORKED! Matt's Problem
46:28
plumberparts
Рет қаралды 411 М.
Ultimate Heat Pump Installation. Rip It Out & Start Again!
31:15
Skill Builder
Рет қаралды 128 М.
My scorpion was taken away from me 😢
00:55
TyphoonFast 5
Рет қаралды 2,7 МЛН