No video

Alarm System Store Tech Video - Honeywell Vista Delay & Zone Programming

  Рет қаралды 171,269

Alarm System Store

Alarm System Store

11 жыл бұрын

Jon Boroughs of AlarmSystemStore.Com shows you how to program entry/exit delays and zone information into a Honeywell Vista alarm system. He also shows you how to wire in and address the primary system keypad. If you have any tech questions then please call 888-811-0727 and choose option 2 on our phone menu.

Пікірлер: 50
@bennynocheese
@bennynocheese 6 ай бұрын
10 years later and you're still educating people like me - great video, super clear explanations. Thanks!
@glassmancarter
@glassmancarter 10 жыл бұрын
Just installed a vista 20P over the weekend and started programming. Excellent video to start. this is my second one to do, a good refresher for me.
@chipmass2438
@chipmass2438 7 жыл бұрын
Great video!, I have a vista 15P with the 6150, the 2 exit doors when open say 05.There is no exit/entry delay on either or anything else. I need help programing the delays on the 6150.I only have 1 good working hand so I am a little slow at the keypadThanks for all your help!!
@electropalsceo
@electropalsceo 2 жыл бұрын
thank you for you support
@johnnyrizzo8057
@johnnyrizzo8057 8 жыл бұрын
good video. would you know of a product that I can install foe 2 way voice. I have installed the evl-4 communicator. I also have voip from an obi-110. do I have any options where I can listen in when alarm or emergency or distress alarm occurs.
@Neuroslicer
@Neuroslicer 7 жыл бұрын
I've currently got 7 wireless sensors on my Vista 15P system and want to add 6 more. Are there enough open wireless slots to do that? How do I check to see what zones have been allocated to my existing sensors, so that I don't assign a new sensor to a zone that is already occupied?
@integritycommunications4079
@integritycommunications4079 7 жыл бұрын
Great work
@AlarmSystemStore
@AlarmSystemStore 7 жыл бұрын
Thanks! We're always trying to do better to put out quality videos. Always nice to hear feedback :)
@edwardasheri9240
@edwardasheri9240 9 жыл бұрын
Nice one
@caleb0606
@caleb0606 6 жыл бұрын
Can you do a video on how to wire and program a Honeywell vista 50p.
@capodelmafia
@capodelmafia 10 жыл бұрын
hi,can you make a video how to enrol a 5834-4 key fob?thank you
@evanstarnes3887
@evanstarnes3887 9 жыл бұрын
how can i set up the moshen sensor to chime.
@wyattoutlaw2370
@wyattoutlaw2370 5 жыл бұрын
Just installed second 61/64 keypad on same bus as 1st keypad. 1st keypad address was 16 .... should the new 2nd keypad be addressed the same or 17 or something- FYI it’s not working
@christofer128
@christofer128 10 жыл бұрын
Dear Friend.I have vista 120 and the house is separate in 5 partition.When arming the partitions separately 1 or 2 etc , the exit delay beeps do not always make sound even if the system starts to arm.Why is that? Why sometimes is arming in silent? All partitions should make exit beeps always and not sometimes.....What do you think??
@Zomby1Woof
@Zomby1Woof 5 жыл бұрын
Thanks for the video. But it's not going anywhere for me. I pressed 1 & 3, then inputted 1 & 6, pressed * and the display goes blank after that and I can't proceed to the next step of putting in the installer code. So now what do I do?
@bradleyferguson723
@bradleyferguson723 5 жыл бұрын
Good Morning just install my Vista 20P, followed the manual info for programming. the system is not reporting open, close or alarm restoral reports, can you determined where did I went wrong?
@varvatrosedition3009
@varvatrosedition3009 7 жыл бұрын
Hi, my HONEYWELL VISTA 20P alarm panel is reading "FC 100". I want to use my door chime but I am not using any monitoring system. Is there anyway to clear the FC100 error and use the alarm as a door chime only? Thank you.
@arkrainflood
@arkrainflood 8 жыл бұрын
my system has issued 3 false fire alerts today, more than minutes apart. each alert has a LOUD voice message "FIRE" and beeping that lasts less than 10 seconds. obviously, there is no fire. what is the procedure to diagnose which sensor(s) is a fault and how to correct? also, is there a way to control the alarm volume- its way too loud?
@davidcramton9665
@davidcramton9665 6 жыл бұрын
My question is, could a bad main vista 20 p alarm panel that is connected to a 4219 zone expander give me an open circuit on the keypad? The wire between the expanded and main panel is good.
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
It's possible, but most times when we see the Open CKT being displayed on the keypad it is because of a bad wire or wire that has snapped inside the wiring sheath or simply that the wires are not hooked to the proper terminals. I would replace the wire between your keypad and the 4219
@angelivanvargas7138
@angelivanvargas7138 10 жыл бұрын
I configured Zone3 for a motion sensor, Zn ZT P RC HW: RT: 03 04 1 10 NC 1 But the panel shows Fautl in this zone, I have a resistor on the sensor, I was told it was needed. Is it really necesary?? What can I do??
@USMC_BABE38
@USMC_BABE38 6 жыл бұрын
Can you please help me I'm trying to reprogram my system because my roommates sister and her boyfriend messed it up while they stayed here at my apartment they did it without asking me first
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
We do have a great tech guide for a Honeywell Vista system that makes programming very easy. Is that the system you're working with? You can find the Vista guide here - www.alarmsystemstore.com/pages/honeywell-vista-series-15p-20p-and-21ip-quickstart-guide
@johnfehn4656
@johnfehn4656 6 жыл бұрын
Also can you reset the alarm from a remote location over the internet?
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
You could add the following device to the system and get that capabilty. It's called the Envisalink 4 and it's made by a company called Eyez-On - www.alarmsystemstore.com/products/envisalink-4-ip-communicator-security-interface-module
@johnfehn4656
@johnfehn4656 6 жыл бұрын
Is it possible to add a time delay to every zone, not just delay entry, I want to monitor five or six doors, when they are opened I want it to be delayed for X amount of time before the vista sees it, is this possible?
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
It is possible to add a delay to the doors like you mentioned. The Vista system has an entery delay 1 and entry delay 2. The reason for this is that you can set a different duration for each delay. You could just make all doors like you were telling about entry delay 1. And if you set entry delay 1 to be 30 seconds in programming then all of those five or six doors would have a 30 second delay when they were opened
@johnkosheluk1041
@johnkosheluk1041 5 жыл бұрын
Hi john my name is John I usto do alarms and took some equipment out of my apartment can i talk to you about it it is all honneywell equipment and a telguard comm
@paparob1960
@paparob1960 3 жыл бұрын
How do i program my key fob to the system.
@richardwilliam3757
@richardwilliam3757 9 жыл бұрын
How do you program function A key location for duress on a 6160? The flow chart on the manual is hard to follow.
@Memerino-ly7yr
@Memerino-ly7yr 8 жыл бұрын
access level 3 is duress
@c-lojefe2422
@c-lojefe2422 3 жыл бұрын
Need a updated video
@RSXSykO
@RSXSykO 8 жыл бұрын
what do you mean by partition 2 vs. partition 1
@baystateelevators5379
@baystateelevators5379 8 жыл бұрын
that means they are like 2 different systems but all on 1 system it also means you can for example have a partition on your basement that means you can arm your basement from your main system but still have the main one disarmed or both
@clarity023
@clarity023 8 жыл бұрын
My alarm system is showing open zones and there's none.
@ronaldchoo4542
@ronaldchoo4542 8 жыл бұрын
my printer can print out report, but when arm/disarm and bypass there's no report. why uh?
@franky4207
@franky4207 4 жыл бұрын
This never worked on my vista
@alarm5582
@alarm5582 6 жыл бұрын
How do you program function keys? (*57)
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
Well, there's a few ways to program those keys. What exactly do you want them to do? They can be used as all panic keys or you can assign one button arming to a few of them. Unfortunately you cannot do both at the same time
@alarm5582
@alarm5582 6 жыл бұрын
Never mind. I found it in the programming manual.
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
Good deal! Glad you found it :) Thanks for watching
@shahainkamal7350
@shahainkamal7350 8 жыл бұрын
i need one how can i gate
@codaddict25
@codaddict25 7 жыл бұрын
shahain kamal Amazon. Honeywell Keypad 6160
@albdrs
@albdrs 10 жыл бұрын
installer code + 800 = long beep.... what does that mean
@evanstarnes3887
@evanstarnes3887 9 жыл бұрын
the installer code is rong. if you want to program the system you have to pouer cycle the panel. when the panel boots up run to the nearest keypad before 50 seconds expires when you give power to the panel. press star and pound to get into programing.
@R13Clothing
@R13Clothing 7 жыл бұрын
I'm pressing 4112 800 but it isn't registering the last 0. Suggestions?
@andybowman9697
@andybowman9697 7 жыл бұрын
Probably a wrong installer code
@R13Clothing
@R13Clothing 7 жыл бұрын
Ok got that sorted. But now my other 2 keypads have blank screens. I addressed them 1 and 2. Suggestions?
@R13Clothing
@R13Clothing 7 жыл бұрын
Nevermind. Figured it out. Thx!
@florenceaube4035
@florenceaube4035 8 жыл бұрын
Traduire en Français svp
Alarm System Store Tech Video - Honeywell 6160 & 6150 Differences
6:59
Alarm System Store
Рет қаралды 42 М.
Alarm System Store Tech Video - Honeywell Vista Alpha Zone Programming
14:07
Finger Heart - Fancy Refill (Inside Out Animation)
00:30
FASH
Рет қаралды 30 МЛН
ТЫ С ДРУГОМ В ДЕТСТВЕ😂#shorts
01:00
BATEK_OFFICIAL
Рет қаралды 9 МЛН
Mama vs Son vs Daddy 😭🤣
00:13
DADDYSON SHOW
Рет қаралды 54 МЛН
Pilot Extends Landing Gear Too Late
2:55
3 Minutes of Aviation
Рет қаралды 503 М.
Vista 20p New zone install and setup
26:40
Fix It With Zim
Рет қаралды 146 М.
Vista 20p Custom Zone Type Tutorial
17:51
Fix It With Zim
Рет қаралды 31 М.
Chap 22 Vista Panel Install - Keyfob Pt 1 Manual Programming
7:04
kurt corbett
Рет қаралды 108 М.
Alarm System Store Tech Video - Honeywell Vista User Code Programming
11:39
Alarm System Store
Рет қаралды 120 М.
DSC NEO keypad PGM output programming
2:18
家華安防 programming made simple
Рет қаралды 288
Honeywell VISTA: Program Wireless Sensor to 6160RF
10:32
Alarm Grid
Рет қаралды 54 М.
Alarm System Store - All about resistors
18:19
Alarm System Store
Рет қаралды 131 М.
basic components required (Vista 20p part 1)
8:55
bounder97
Рет қаралды 76 М.
Finger Heart - Fancy Refill (Inside Out Animation)
00:30
FASH
Рет қаралды 30 МЛН