Рет қаралды 301,121
This video demonstrates how to unlock the test functions found in the E39 BMW models equipped with the "low" gauge cluster or on board computer (OBC). Here's a full list of the test functions available:
Test 01. Vehicle specific data
1.0 VIN
1.1 K-value
1.2 Part number of cluster
1.3 Coding/Diagnosis/Bus Index
1.4 Manufacturing date (calender week/year)
1.5 Hardware/software # of cluster (HW:XX, SW:X.XX)
1.6 Injection status, number of cylinders, engine factor
Test 02. Cluster System Test - activates the gauge drives, indicators and LEDs to confirm function
Test 03. SI Data
3.0 Liters
3.1 Periodic inspection days (not applicable for U.S.)
Test 04. Momentary Consumption
4.0 XX.X liters/1000km
4.1 X.X liters per hour
Test 05. Distance Gone Consumption
5.0 XX.X liters/100km
5.1 momentary distance to go (XXXkm)
Test 06. Fuel Level Sensor inputs in liters
6.0 Fuel level average (LH sensor input = XX.X liters, RH sensor input = XX.X liters)
6.1 Total tank level averaged XX.X liters
6.2 indicated value and tank phase (1 = both sensors OK, 2 = one sensor fault, 3 = implausible input)
Test 07. Temperature and Speed
7.0 Coolant temperature input XX.X degrees Celsius
7.1 Intake air temperature input XX.X degrees Celsius
7.2 Engine speed XXXX RPM
7.3 Vehicle speed XXX km/hour
Test 08. Input values in HEX form
8.0-8.3 Hex code, instrument cluster inputs
Test 09. Battery Voltage
9.0 Battery voltage XX.X Volts
Test 10. Country Coding
10.0 US XX
Test 11. Cluster Code
11.0 Cluster code
Test 12. Not used
Test 13. GONG Test
13.0 Activate gong by pressing button (gong response is delayed)
Test 14. Fault memory (not for diagnosis)
Test 15 to 18 not used
Test 19. Lock/Unlock
L-On...
L-Off 19.0
Display changes from "L-ON" to "L-OFF" every second. To unlock test functions, press the cluster button immediately when it changes to "L-OFF". Test are automatically locked when exiting test functions.
Test 20 Average fuel consumption - correction factor
The factor follows previous systems, with adjustment range of 750 to 1250. The adjustment method is new for the base cluster. If adjustment is necessary, enter into test 20 using the cluster button.
The correction factor number is changed by using the sub-tests for the "ones, tenths and hundreds of the factor number. The digits will automatically scroll through 0-9 within each group (ones, tenths, hundreds).
20.0 Press the button to reset display to 1000
20.1 Press the button when the correct "ones" position is attained
20.2 Press the button when the correct "tenths" position is attained.
20.3 Press the button when the correct "hundreds" position is attained.
Test 21. Software Reset
21.1 Reset software