Connecting a power logger to a LIVE 600A fuse board | REC04

  Рет қаралды 20,151

Residual Electrical

Residual Electrical

Күн бұрын

In this video I'm connecting up a couple of Chauvin Arnoux PEL 104's to a live Ryefield fuse board.
Part 1
• £20,000 electricity bi...
Part 3
• I power logged a whole...
For more info on the power energy loggers checkout ‪@ChauvinArnouxUK‬
If you enjoy electrical content please subscribe to the channel and checkout my links below 👇
S E R V I C E M 8
30% Off your first 6 months - get.servicem8....
M Y W E B S I T E ⚡
residualelectr...
B I G B O O T S D I S C O U N T 🥾
bigboots.co.uk... - Use code RESIDUAL
U N I L I T E D I S C O U N T 🔦
unilite.co.uk/... - Use code RESIDUAL
J O I N T H E C H A N N E L 🤝
/ @residualelectrical
I N S T A G R A M 📷
/ residualcurrent
T I K T O K ♪
vm.tiktok.com/...
The works carried out in the video and the opinions shared are my own, and not representative of the associates and companies in the video.
This content is purely for entertainment purposes and is in no way a "how to", tutorial or educational video.
Please consult an electrician when dealing with any electrical installations.
#electricianlife #electrical #electricalcontractor

Пікірлер: 49
@petehiggins33
@petehiggins33 4 ай бұрын
A reactive load of -3.5kVAR corresponds to a capacitance of about 200uF hanging directly on the mains. It's a big capacitance and I can't think of anything that would do that, so I suspect that there might be a faulty grid tie inverter connected which is failing to match the phase of the supply. It might be an idea to repeat this measurement at night when there's no solar power.
@residualelectrical
@residualelectrical 4 ай бұрын
Check the latest video, it looks like you’re correct!
@we-are-electric1445
@we-are-electric1445 4 ай бұрын
Unless there is a lot of electronics connected you would expect (on balance) the load to be more inductive rather than capacitive.
@callumblacknell6464
@callumblacknell6464 Ай бұрын
Wicked mate 🎉
@russellslater4037
@russellslater4037 4 ай бұрын
Fantastic, I've finally got my head around PF. Thank you, thank you, thank you.
@residualelectrical
@residualelectrical 4 ай бұрын
Glad it’s helped!
@three-phase562
@three-phase562 4 ай бұрын
Interesting that the VAr reading on the first PEL was negative indicating a capacitive load rather than inductive. The second PEL to the plant room was showing inductive VAr, 0.9 pf is pretty respectable for motor plant. Would be interesting to see what the pf closer to the intake is, as the capacitive loading should counteract the inductive loading. For connections into boards like this I have a set of fly leads made up with 4mm safety sockets on them that connect direct into the leads to save taping the crocodile clips in place. For Red Spot fuses, I have a set with the 4mm sockets built into the fuse carrier.
@residualelectrical
@residualelectrical 4 ай бұрын
Nice, can you send me some pics of those? They sound great!
@retozaugg3775
@retozaugg3775 4 ай бұрын
You said that there is a bit of PV connected to the board with the bad power factor. One time we had a case, where the inverter was faulty. It produced a huge apparent power and was tripping the 25 A fuses, but the meter only read a few amps active power.
@tangojango44
@tangojango44 4 ай бұрын
If the load and generation are closely matched, then irregular power factors are quite common. It would be worth turning off the solar and re-checking those readings. Though at 5pm you wouldn't expect much of an influence.
@gokugeorge011
@gokugeorge011 4 ай бұрын
I will be very glad if you can make me your apprentice 🙏🙏 ..i have a electrical backround.
@gokugeorge011
@gokugeorge011 4 ай бұрын
I will be very glad if you can make me your apprentice 🙏🙏 ..i have a electrical backround.
@John_Faultless
@John_Faultless 4 ай бұрын
Great video mate. It's really good to see someone explaining the potential losses due to low power factor. Look forward to the results 🫡
@residualelectrical
@residualelectrical 4 ай бұрын
Thanks John!
@Ash-gw2bk
@Ash-gw2bk 4 ай бұрын
We love to see it I told you I’d be back 👌
@001Elan
@001Elan 4 ай бұрын
Hey Mike great vid mate followed since you started , so thought I’d kindly point out …. Wearing your arc flash is a good example to the majority who don’t, but without your balaclava it’s fairly irrelevant, your head is well within the theoretical arc flash zone which means second degree burns if all goes up ! On hands that’s a problem , on your neck and face ??!!! Please take care , keep safe
@residualelectrical
@residualelectrical 4 ай бұрын
Thanks elan!
@Ronny86_
@Ronny86_ 4 ай бұрын
Nice video Mike! Looking forward to the next one
@residualelectrical
@residualelectrical 4 ай бұрын
Thanks Ronny!
@lewisbrand
@lewisbrand 4 ай бұрын
Most LED luminaires are around 0.8 power factor or less.
@michaelpatrick6950
@michaelpatrick6950 Ай бұрын
Is it true that if the motors were synchronous, they'd have a leading power factor? I installed some 2000 and 3500 hp synchronous motors running on 1300V about 40 years ago and they had a 1.2 leading PF.
@rcoombs100
@rcoombs100 4 ай бұрын
Hi there, thanks for the vid. What size fuses did you replace the originals with when you powered up?
@_eusty
@_eusty 4 ай бұрын
5:53 made you jump!
@0liver0verson9
@0liver0verson9 4 ай бұрын
huh?
@stefankruger3634
@stefankruger3634 2 ай бұрын
thank you
@danwright7779
@danwright7779 2 ай бұрын
Where do you learn all this info ,m
@ShalomBrother
@ShalomBrother 4 ай бұрын
Your shaping like your disarming a 💣
@residualelectrical
@residualelectrical 4 ай бұрын
Search and destroy 🪖
@Uk_Grid_Engineering
@Uk_Grid_Engineering 4 ай бұрын
This is the issue with solar, tye inverters are all designed to produce a perfect power factor, when a prem has an amount of reactive power and an amount of real power, the solar can offset the real but cannot change the reactive, that remains constant, hence why the oower factor is worse with solar
@residualelectrical
@residualelectrical 4 ай бұрын
Just read the white paper, thanks man!
@0liver0verson9
@0liver0verson9 4 ай бұрын
Very interesting stuff. So it's possible a supply can alter the cost of electricity? Or is the "power factor" related to something else? I work with meters and obviously some customers dispute meter reads and bills. This usually results in a 2nd check meter being installed to run concurrently. I wasn't aware of other factors on the supply side that alter bills, if that's what you're investigating.
@Ronny86_
@Ronny86_ 4 ай бұрын
It’s to do with real power and apparent power. Basically the property is wasting electric that could be used but instead it’s not. It’s nothing to do with the meter side of things but more the equipment using the power. And power factor isn’t really used in domestic properites
@0liver0verson9
@0liver0verson9 4 ай бұрын
@@Ronny86_ ok thanks, all good to know
@cameronmantell9959
@cameronmantell9959 4 ай бұрын
@@0liver0verson9 Yea, Ronny is right: nothing to do with supply but depends what loads are installed. Inductive loads like induction motors will lag the power factor by nature, dropping the power factor. Lagging power factor reduces real power, but the supply company still needs to pay to transport the total current (real + reactive). They are only concerned with VA through the lines, so they effectively charge you more than the real power you are using. Only really applies to commercial properties that would have lots of inductive loads (e.g. lots of induction motors)
@0liver0verson9
@0liver0verson9 4 ай бұрын
@@cameronmantell9959 Well I just learnt something! Cheers
@Fishfingersarnie
@Fishfingersarnie 4 ай бұрын
Any plans for a BMS? would save all of the confusion in the future and allow for live readings at any point.
@residualelectrical
@residualelectrical 4 ай бұрын
Sure would, I don’t think they would install one though.
@cliveramsbotty6077
@cliveramsbotty6077 4 ай бұрын
does direction of flow matter when im using my clamp meter to measure current?
@MrMaxyield
@MrMaxyield 4 ай бұрын
AC amps and DC amps should be measured separately... There are 2 separate positions on a meter to measure each one respectively...
@three-phase562
@three-phase562 4 ай бұрын
He is measuring power, so the meter needs to know the direction of the current to differentiate between exporting an importing electricity. Hence the clamps have a direction arrow, so you put them all in the same direction. For normal clamp use on AC to measure current only, it doesn't matter quite so much.
@ShalomBrother
@ShalomBrother 4 ай бұрын
No
@cliveramsbotty6077
@cliveramsbotty6077 4 ай бұрын
@@three-phase562 thanks
@hvsparky
@hvsparky 4 ай бұрын
Great video pal 💪🏼💪🏼
@residualelectrical
@residualelectrical 4 ай бұрын
Thanks mate!
@walseee
@walseee 4 ай бұрын
BOOOOSH
@we-are-electric1445
@we-are-electric1445 4 ай бұрын
That 0.33 PF looks suspicious !
@1992Craigster
@1992Craigster 4 ай бұрын
Noice
@samuelchamberlain2584
@samuelchamberlain2584 4 ай бұрын
Crap led drivers ?
@residualelectrical
@residualelectrical 4 ай бұрын
Possible, but the PF is a lot better at night so can’t be those alone!
I power logged a whole building for a week | REC05
32:52
Residual Electrical
Рет қаралды 13 М.
Double stack Easy9 fuse board second fix
26:41
Residual Electrical
Рет қаралды 23 М.
The perfect snowball 😳❄️ (via @vidough/TT)
00:31
SportsNation
Рет қаралды 77 МЛН
And what’s your height? 😁 @karina-kola
00:10
Andrey Grechka
Рет қаралды 52 МЛН
Strange dances 😂 Squid Game
00:22
عائلة ابو رعد Abo Raad family
Рет қаралды 29 МЛН
£20,000 electricity bill? Lets investigate why | REC03
18:55
Residual Electrical
Рет қаралды 18 М.
Connecting a 630A supply into a 2000A 3 phase panel
23:25
Residual Electrical
Рет қаралды 14 М.
Safety Checks for Neutral Current Diversion
19:32
SELECT
Рет қаралды 531
High Voltage testing with SensorLink - Troubleman's kit
17:36
Bobsdecline - Lineman blogger
Рет қаралды 235 М.
Terminating a 630A 3 phase supply | REC11
27:39
Residual Electrical
Рет қаралды 88 М.
Quitting my job and going out on my own | REC01
26:06
Residual Electrical
Рет қаралды 29 М.
Large Diesel Generator - Shuts Down With An ERROR | Can I fix It?
19:31
How Japan Made Their Outlet Safe
12:32
Andrew Lam
Рет қаралды 865 М.
Working in a 2000A widow maker
58:52
Residual Electrical
Рет қаралды 356 М.
FAILED Commercial EICR  | ØY39
33:59
Cory Mac - ØY Electrical
Рет қаралды 46 М.
The perfect snowball 😳❄️ (via @vidough/TT)
00:31
SportsNation
Рет қаралды 77 МЛН