I replaced my manifold that had froze....9 years ago. It is still working to this day...you ROCK !!!!
@venanciomarquez1863 Жыл бұрын
Hi sr, thank you for the good video. Have a nice day.
@bandrada8 жыл бұрын
Thank you, Thank you, Thank you! Your video helped me out a lot!
@bobbycord85225 жыл бұрын
One important note with the ignitor being so fragile remove it first before pulling the top plate and put it back in last after the top is back in place. Broke 2 in this process
@Midan5911 жыл бұрын
Hi Jay I have Sta Rite Heater Model SRC400NA with 400 K BTU/hr .. when i checked exhaust temperature is was 372 F. So i have to go and change the parts as you mention in your video .. Thank you
@graciebaby49844 жыл бұрын
Do you service Southern California area? Thank you
@darrenlandry94457 жыл бұрын
my service heater light is on and heater will not fire. i have an afs light on the back of the board, what does that mean?
@pvt-pilot5 жыл бұрын
The control board is looking for a hard short from the AFS as soon as the blower turns on. Watch "PENTAIR MASTERTEMP 400 POOL/SPA HEATER AFS AIR FLOW SWITCH ERROR LIGHT REPAIR" on KZbin kzbin.info/www/bejne/noarq5p-p8hsfZI
@graciebaby49846 жыл бұрын
Hi. On our sta-rite heater the display board is showing E06 error code? What is this? Thanks
@braydinjones63015 жыл бұрын
Stack flue sensor. Either its bad or ur exhaust temp is too high, causing the heater to shut down.
@braydinjones63015 жыл бұрын
First thing id do is take a reading of the flue temp with an infrared thermometer. If that is fine, then replace the stack flue sensor. Simple as that. Things that could cause high temp are things lke the gas pressure being set too high or an exhaust blockage.
@braydinjones63015 жыл бұрын
Or things like in the video
@Mapleviewdesignsco9 жыл бұрын
if my heater SR400HD is running at 450F could mine be the same problem? or do i need a new heat exchanger?
@whitemok6 жыл бұрын
same here. what did you do?
@dictumfactum77844 жыл бұрын
Absolutely limed up. Just get a new heater
@Theuaflyer71011 жыл бұрын
I'm having similar problems , what do I ask for from the pool company ?
@dapooltec12 жыл бұрын
About $325.00
@larryzeka50112 жыл бұрын
Lol what the customer get charged for this? That unit would continue to run without faults at that stack temp. But yes it’s technically to high. But given the age of that heater I don’t know that the cost of the repairs is worth it.
@dictumfactum77844 жыл бұрын
Pentair/stay worst, junky heaters don't buy these. There is a reason why i can move it all by myself.