Design of Singly Reinforced Concrete Rectangular Sections. How to Design It in 1 Minute? 3 STEPS.

  Рет қаралды 21,098

The Efficient Civil Engineer (by Dr. S. El-Gamal)

The Efficient Civil Engineer (by Dr. S. El-Gamal)

Күн бұрын

Пікірлер
@abdirahmanbishar9588
@abdirahmanbishar9588 2 жыл бұрын
welcome back Dr El-Gamal, this is incredible lecture
@MrElgamal77
@MrElgamal77 2 жыл бұрын
Thanks. You're welcome 😊
@folahan007
@folahan007 7 ай бұрын
Fantastic and Clear teaching. Well done Sir
@MrElgamal77
@MrElgamal77 7 ай бұрын
So nice of you. Keep watching.
@gayanpriyadarshana1504
@gayanpriyadarshana1504 6 ай бұрын
very clear and great teaching skills.
@rllrll9512
@rllrll9512 Жыл бұрын
Doctor i liked your detailed explanation.. I was waiting to understand what K means and how it affects the section, but you did talk about it.
@mojeedobisesan6748
@mojeedobisesan6748 2 жыл бұрын
Very useful content. Thank you, Sir.
@MrElgamal77
@MrElgamal77 2 жыл бұрын
You are welcome
@السيفاليماني-ه8ظ
@السيفاليماني-ه8ظ 11 ай бұрын
بالرغم انه بالانجليزي لكن نتابع يا دكتور الله يجعله في ميزان حسناتك
@MrElgamal77
@MrElgamal77 9 ай бұрын
اللهم آمين
@venkateshgidijala
@venkateshgidijala 2 жыл бұрын
Hello sir. Glad to see great content open for every one. May i know , on which standards ,these design procedures are work on? Indian standards or British standards?
@MrElgamal77
@MrElgamal77 2 жыл бұрын
Thanks. British standards.
@mohamedmaher87
@mohamedmaher87 2 жыл бұрын
Thanks alot...is there lectures shows how ti use steel charts in bs code ..thanks again
@RsapRevit
@RsapRevit 6 ай бұрын
Hi sir, what's the factor 0.45 and 0.95?
@enami_0136
@enami_0136 9 ай бұрын
hello. can this be applied to the old frensh norm BAEL? cs the basics of this seams similar to it
@MrElgamal77
@MrElgamal77 9 ай бұрын
The bases of most codes are similar. But there are some few differences.
@enami_0136
@enami_0136 9 ай бұрын
okay thank you @@MrElgamal77
@oladapoowoyokun9320
@oladapoowoyokun9320 2 жыл бұрын
Thank you, doctor. This video was really helpful. It solved a lot of problems for me in this course Please which table did you use to calculate the number and diameter of bars (4T20) and Ast provided
@karimalsaid1951
@karimalsaid1951 Жыл бұрын
Since this guide is based on british standard BS, then "BS 4449 - Carbon steel bars for the reinforcement of concrete", section "5 - Cross sectional area and mass", "Table 2 - Cross sectional area and mass", diameter 20 as assumed by the Dr., has cross-sectional area of 314.2 mm2. Ast provided is the area of the steel that you assumed (against required 1147 mm2), here assumed is 4 x T20, which would have an area of 4 x 314.2 = 1,256.8 mm2.
@agostinhoinocencio7013
@agostinhoinocencio7013 Жыл бұрын
Hello Sr i hope you are well may God bless you you have been my lecturer since i started my course i know all your video there are really helpful, you said that k is help us to know if we can use only tension or tension and compression (singly and double), i would like to know which K can we use to find (Z) or (leaver arm)? is it k' primer or K that we calculate, in example you use k that you calculated how should i have to know that k you calculated is the one to use to find (Z) i am very confused about it pls help me Sr.
@MrElgamal77
@MrElgamal77 Жыл бұрын
Hello. If k is less than k', then it will be singly reinforced and you will use k to get z. If k is greater than k', then it will be doubly reinforced section. The z in this case will be constant as 0.775 d. This 0.775d, you can get it from the z equation by using k' but you do not need. It will be always 0.775d.
@abdulmonimmohamedali9146
@abdulmonimmohamedali9146 2 жыл бұрын
Thanks for helping us doctor, and I wanna ask a question ⁉ why has BS 8110 part 1_ 1997 been limiting the value of lever arm should not be taken less than 0.95 times the effective depth . Thanks once again doctor.
@MrElgamal77
@MrElgamal77 2 жыл бұрын
It should be less than or equal to 0.95d. The code put this limit for safety and to insure that part of the concrete in the compression will be available to resist the compression forces. This will also give more steel reinforcement.
@v-creations24
@v-creations24 4 ай бұрын
Am confused between these two formula doing the same thing. As=M/0.95fyz and As=M/0.87fyz which one is which
@sharmakeabdullahicisman4396
@sharmakeabdullahicisman4396 2 жыл бұрын
Thank you sir Please i need one vedio or example based on uniform distrubuted load on beam load from solid two way slab and one way slab
@MrElgamal77
@MrElgamal77 2 жыл бұрын
Here a video about transferring load from one way slab then designing the beam. kzbin.info/www/bejne/gYebeaWOj5WdbKM
@sharmakeabdullahicisman4396
@sharmakeabdullahicisman4396 2 жыл бұрын
Thank you Dr sharif Please sir give me your adress of your email any problem to help me rcc design
@izuchukwuokafor8130
@izuchukwuokafor8130 Жыл бұрын
But Sir how do we find Mu ,like is the (ultimate moment )different from Mmax (maximum moment )?
@paulezeh6333
@paulezeh6333 8 ай бұрын
Sir where did you get your As provided from? How can it be calculated
@MrElgamal77
@MrElgamal77 8 ай бұрын
I have a small table that I did that shows the area of reinforcement based on the number of bars and diameter.
@MrElgamal77
@MrElgamal77 8 ай бұрын
You can do it easily in excel
@siyatahmed21
@siyatahmed21 10 ай бұрын
Amazing
@MrElgamal77
@MrElgamal77 9 ай бұрын
You are welcome
@ahmadabdelrahman9291
@ahmadabdelrahman9291 2 жыл бұрын
Why if z>0.95d .. take it as 0.95d ??
@MrElgamal77
@MrElgamal77 2 жыл бұрын
Yes.
@dimamoghrabi3366
@dimamoghrabi3366 2 жыл бұрын
Me too I have the same question According to what you explained in this video the value of (z) should not be exceeded than .775d In order to ensure tension failure So why .95d
@sharmakeabdullahicisman4396
@sharmakeabdullahicisman4396 2 жыл бұрын
Thanks ustaad sharif i ask you one quastion for equation formula load from solid slab two way area trapizodal n×area of trapizodal/long side of panel or ly sir that formula is correct or not And area of trangular transfer to beam formula n×area of trangle/short span or lx that formula is correct or not
@MrElgamal77
@MrElgamal77 2 жыл бұрын
Yes. This will give a uniform load on beam. The shear force using this method will be correct but the moment will be under estimated.
@sharmakeabdullahicisman4396
@sharmakeabdullahicisman4396 2 жыл бұрын
Thank you sir Please i need one vedio or example based on uniform distrubuted load on beam load from solid two way slab and one way slab
@irfanullah8255
@irfanullah8255 2 жыл бұрын
❤️❤️❤️
@MrElgamal77
@MrElgamal77 2 жыл бұрын
Thanks. Please share with your colleagues.
@irfanullah8255
@irfanullah8255 2 жыл бұрын
@@MrElgamal77 Sure, Sir.
@irfanullah8255
@irfanullah8255 2 жыл бұрын
Sir would you like to send me RCD and plastic Analysis slides please?
The Capacity of Singly Reinforced Concrete Rectangular Sections. Three Easy Analysis Steps.
17:35
The Efficient Civil Engineer (by Dr. S. El-Gamal)
Рет қаралды 18 М.
Doubly Reinforced Concrete Rectangular Sections (Design and Analysis) - Clear Steps with 2 Examples.
22:50
The Efficient Civil Engineer (by Dr. S. El-Gamal)
Рет қаралды 27 М.
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН
Design of Reinforced Concrete Two-Way Solid Slabs using BS8110 Code (Part 1)
34:00
The Efficient Civil Engineer (by Dr. S. El-Gamal)
Рет қаралды 80 М.
Understand Reinforced Concrete Design - Analysis of RC Sections - BS8110
10:37
The Efficient Civil Engineer (by Dr. S. El-Gamal)
Рет қаралды 28 М.
Amazing innovative tools and ideas in metal turning
15:27
بيت الهيدروليك & Hydraulic house
Рет қаралды 10 М.
The Dome Paradox: A Loophole in Newton's Laws
22:59
Up and Atom
Рет қаралды 729 М.
Design of Reinforced Concrete Columns (Part 1)
29:14
The Efficient Civil Engineer (by Dr. S. El-Gamal)
Рет қаралды 130 М.
C&D Waste-Free Mumbai
2:32
CFlo World Limited
Рет қаралды 94
What is mathematical thinking actually like?
9:44
Benjamin Keep, PhD, JD
Рет қаралды 9 М.
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН