Panel Upgrade, Interlock, and Portable Generator Wiring Part 2

  Рет қаралды 3,487

Electrician Ron

Electrician Ron

Күн бұрын

In this video the portable generator wiring is completed by installing an interlock and inlet device box on the exterior. This includes the installation of a 30 amp, 240 volt feeder for the connection from the generator to the electrical panel snd loads. I hope you enjoy this video!
Classic Electric, LLC | Point Pleasant, New Jersey
License & Business Permit # 16557
(732)-770-1437
Square D QO LOAD CENTER 200 AMP MAIN BREAKER 54-SPACE Model # QO154M200P
Square D QO Panel Cover for 54-SPACE MB Model # QOC54UF
Square D QO SURGE PROTECTION Model # HEPD80
Square D QO Generator Interlock Kit Model # QOCGK2C
Reliance Power Inlet Box Model # PB30
Electrical Wiring is NOT a hobby. Call a licensed electrician!
This video is NOT sponsored. Some product links are affiliate links which means if you buy something I’ll receive a small commission.
A few of my favorite tools I use on a daily basis:
Veto TP-XXL #1 tool bag w/ 47 pockets: amzn.to/40gkWZx (Amazon)
Klein 9” Hybrid Pliers w/ crimper, fish tape puller, and stripper: amzn.to/4dGpHyH (Amazon)
Klein Tools Circuit Breaker Finder, Voltage Tester, and GFCI receptacle tester: amzn.to/3SJxZhx (Amazon)
Milwaukee M12 Impact and Drill Combo Kit: amzn.to/4dF7BgA (Amazon)
Milwaukee 6-Piece Cushion Grip Screwdriver Kit: amzn.to/3WJNUxc (Amazon)
Fluke T6-600 Electrical Tester: amzn.to/4dF7nWM (Amazon)
Want to be an electrician? Start here: www.myelectric...
Ron Pecina Jr. is a licensed electrician & contractor in the state of New Jersey since 2009.
This allows him to apply for electrical permits, work with live conductors, remove meters, and disconnect service from the utility company.
New Jersey observes the 2020 NEC and the Uniform Construction Code.
The majority of the work you’ll see on my channel falls under the New Jersey Rehabilitation Sub Code (Chapter 6 of the U.C.C.) www.nj.gov/dca...
ALL New Jersey licensed electricians MUST complete 34-hours of continuing education units each tricentennial period.
This includes a mandatory 9-hour code update course and (1) hour business law class.
Any work above 10-volts requires an electrical license in New Jersey.
Become an NJ-IEC member here: www.nj-iec.org
Ron is an active member of the New Jersey Independent Electrical Contractors Association.
Contact: newjersey@ieci.org (732)-276-2295
Since 2023, Ron has been an apprenticeship instructor at the NJ-IEC Education and Training Center, Somerset, NJ.
The Independent Electrical Contractors association represents merit shop electrical contractors.
Chapters are located nationwide in the USA.
Join with us and stand up for your industry by becoming an NJ-IEC member here: www.nj-iec.org
Customer Guide for Electrical Installation; JCPL: www.firstenerg...
Customer Guide for Electrical Installation; PSEG: nj.pseg.com/bu...
WANT TO SEE MORE? FULL 200 AMP SERVICE UPGRADE. WATCH HERE: • KZbin Subscriber in ...
Classic Electric, LLC is a Generac standby air-cooled generator installer and authorized dealer.
Ron Pecina Jr’s set up:
Camera: Go Pro 9/ 10 w/ the Media Mod
Microphone: DJI Wireless
Editing software: Apple iMovie
Animation software: Apple Keynote
Background Music & Sound Effects by Soundstripe.com
Like, Share, and Subscribe!

Пікірлер: 38
@heynow01
@heynow01 4 күн бұрын
Great videos Ron! I've been watching other ones and yours suddenly got fed to me. Love the way you FF through the slow stuff and narrate to explain what you are doing. Excellent electrician and video creator too.
@spudman9367
@spudman9367 11 күн бұрын
It might be worth explaining bonded and floating neutral. Most portable generators are bonded and before using a bonded neutral generator it must be converted to floating. There are some great KZbin videos explaining and showing what must be done. Great video! As a retired electrician I enjoy watching,
@jeremyplant3013
@jeremyplant3013 11 күн бұрын
So if a generator is bonded at the neutral, remove the bonding jumper, and the 10/3 or 6/3 (depending on watts of generator) will have the neutral and ground bonded at the main panel?
@spudman9367
@spudman9367 11 күн бұрын
On KZbin check out this video titled ‘What is a Floating Neutral Generator? By Benjamin Sahlstrom
@spudman9367
@spudman9367 11 күн бұрын
What is the make and model of your generator? And running watts
@zekenzy6486
@zekenzy6486 Күн бұрын
Great video. Thank you for sharing
@jamescollins8148
@jamescollins8148 8 күн бұрын
Nice Job! As usual!
@ClickinChicken
@ClickinChicken 11 күн бұрын
I played electrician with wiring a Generator Transfer switch (Reliance). I converted the gas Generator(4,500 Watt) to propane. I used 6 Gauge wire for the run to transfer switch. It's all hooked up right, but I didn't need that thick of wire (all that NEC stuff). Haven't done jack diddle since. Other than that? -SAVE AMERICA!
@mackfisher4487
@mackfisher4487 11 күн бұрын
Ron as always neat and workmanlike manner
@NitinSharma-tl8rw
@NitinSharma-tl8rw 2 күн бұрын
Namaste sir ji i am from West Delhi
@anthonyelectric6045
@anthonyelectric6045 11 күн бұрын
Great job Ron. I like the attention to detail and giving the customer the instructions on the use of emergency power backup. Great idea 👍 when I did these upgrades I’d have the customer actually go through the process you shown so I felt better leaving the job etc.
@vince6829
@vince6829 11 күн бұрын
Awesome video!! Thank you for sharing your knowledge.
@matthewwerner1057
@matthewwerner1057 11 күн бұрын
Have been doing these a lot in Lake Arrowhead CA. Nice job Ron! Love the QO panel too
@electricianron_New_Jersey
@electricianron_New_Jersey 11 күн бұрын
If I could only do panel upgrades for the rest of my career I’d be a happy man!
@720vending
@720vending 11 күн бұрын
Great job love the video and when i do my own 200A upgrade to my home i will be adding the generator as well where can i find a copy of those generator instructions
@electricianron_New_Jersey
@electricianron_New_Jersey 10 күн бұрын
Thank you!
@billhandymanbill2775
@billhandymanbill2775 11 күн бұрын
Excellent! I always enjoy your video as you explain them so well and therefore they are easy to understand. Very professional! Yes, it would be helpful to explain bonded and floating neutral with regards to a generator.
@electricianron_New_Jersey
@electricianron_New_Jersey 9 күн бұрын
Thank you very much!
@Allison11111
@Allison11111 3 күн бұрын
why would the main switch need to be on when you installed the interlock ?
@heynow01
@heynow01 4 күн бұрын
I was checking into setting up the bypass interlock on my main panel for a temp aux power back up power generator, but my panel has two separate doors one side has the meter and the main shut off and the other side has all the breakers. There's no knock outs for the new aux breaker to set up the lock out. Is my only practical alternative a new panel?
@donmclean1220
@donmclean1220 11 күн бұрын
I installed a generator inlet like this. I didn’t follow the proper shutdown process when I tested it. I think I shut off the generator while still powering the house circuits. One of my hard wired smoke detectors started sounding, I think it got fried, I had to replace it. Now I will follow the proper procedure. My install was inspected by the county and passed (cost me $246 for the permit).
@electricianron_New_Jersey
@electricianron_New_Jersey 9 күн бұрын
You're right, you gotta follow the shutdown procedure or the smoke detectors can fry.
@Coast-2-Most
@Coast-2-Most 5 күн бұрын
Im here because i saw you on another video from Jan 20th! MAGA!
@vidupload4578
@vidupload4578 4 күн бұрын
Reтаrds 🤣
@arnieselectric007
@arnieselectric007 10 күн бұрын
Hey Ron, Awesome video brother...I do quite a bit of these here in the York and Lancaster, PA Areas too...Now one question...as a former Sea Bee, why the Tin Can Alumni Hat..? Just curious as most Sea Bees never even see a ship...
@electricianron_New_Jersey
@electricianron_New_Jersey 10 күн бұрын
I'm a Navy guy. DD-214 is code for discharge papers. It's Seabees as in Seabees Can Do. We build, we fight, we party all night!
@arnieselectric007
@arnieselectric007 6 күн бұрын
@@electricianron_New_Jersey I'm a Navy guy too...GMG3 USS Butte AE-27...at a glance I missed the DD-214 and thought it was a DDG insignia which is for a Destroyer...my bad...my oldest son was a Sea Bee he was a CE...
@justmc62
@justmc62 11 күн бұрын
Very informative Ron .. Like the instructions you left. My concern is that the homeowner will put all the breakers back on and trip/stall the generator. A knowlegeable homeowner is always a pleasant experience on jobs like this. One question.. is NM cable allowed to be installed on an exterior installation for the twist lock ?
@nickk05281982
@nickk05281982 11 күн бұрын
Isn’t Smurf cable for low voltage?
@electricianron_New_Jersey
@electricianron_New_Jersey 11 күн бұрын
Smurf tube is ENT, NEC article 362. It’s junk imo but it’s everywhere at this house. The previous owner must’ve hired a real hack.
@richb4099
@richb4099 11 күн бұрын
Need a cover for the 4” metal box on the left of the panel.
@electricianron_New_Jersey
@electricianron_New_Jersey 11 күн бұрын
Need two of them. I didn't have anymore on the truck. FML.
@richb4099
@richb4099 11 күн бұрын
@ 👍
@ed6837
@ed6837 11 күн бұрын
No insulated NM cable staples in NJ?? Guess that must be a Mass thing
@antwill3425
@antwill3425 11 күн бұрын
Would it be ok to squeeze dielectric grease inside the plug to help avoid corrosion of the female prongs?
@MrTooTechnical
@MrTooTechnical 11 күн бұрын
Very nice. About the generator: if the generator frame is either bonded or not, is the wiring in the panel and interlock config the same?? Thanks
@MrJpiarull
@MrJpiarull 11 күн бұрын
How often do you get contracted to do a Kohler or Generac automatic generator install when it's feeding 100+ amps? My parents did a Generac right after Sandy, still took 8 months because of the backlog
@electricianron_New_Jersey
@electricianron_New_Jersey 11 күн бұрын
@@MrJpiarull I just ordered a Generac model # 7043 earlier this week. I’ll probably start that job next week
200A  Main Breaker Panel Upgrade to 54 Circuits | Part 1 of 2
34:30
Electrician Ron
Рет қаралды 6 М.
Completely upgrading an existing 120/ 240V electrical service to 200 AMPS
33:43
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 45 МЛН
When you have a very capricious child 😂😘👍
00:16
Like Asiya
Рет қаралды 18 МЛН
We Need Internet! Running a 3,000 ft Fiber Optic Cable
19:53
The Homesteading RD
Рет қаралды 462 М.
Why Do We Use Ground Rods?
14:41
Electrician U
Рет қаралды 75 М.
U.K. Electrics SUCK! This is what we should be doing…🇫🇷
19:17
Artisan Electrics
Рет қаралды 276 М.
Business Owner/ Licensed Electrician at 22 Years Old
23:06
Palmer Electrical
Рет қаралды 2,2 М.
Just Another 200 AMP SERVICE UPGRADE #electrician  #200AMPS
25:54
Electrician Ron
Рет қаралды 9 М.
FULL 200 AMP SERVICE UPGRADE | CLARK, NJ
51:14
Electrician Ron
Рет қаралды 130 М.