Fire Alarm System Full Upgrade At Elementary School | replacing system | Notifier NFS2-3030 Day 1

  Рет қаралды 37,274

NIC’S - SYSTEMS & ELECTRIC

NIC’S - SYSTEMS & ELECTRIC

Күн бұрын

Пікірлер: 204
@Yarrrrsmodz
@Yarrrrsmodz 9 ай бұрын
Just wanted to say I currently work at an engineer firm that specializes in fire alarm system design. Engineers have no idea how things are going to be installed in the field. I feel like being able to understand that and having a good working relationship with the installing contractors makes everyone's job easier. Also, I have been watching your videos for awhile now and always find them informative and appreciate the knowledge you have for this field.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
You are 100% The job goes so much smoother if you work together and realize everyone makes mistakes and instead of holding it as a grudge address it and learn from it if possible
@julieuehline9334
@julieuehline9334 4 ай бұрын
⁠rfs
@julieuehline9334
@julieuehline9334 4 ай бұрын
Stop the roadie
@BluepuptweetElevators
@BluepuptweetElevators 9 ай бұрын
Off topic, but that architecture is awesome
@fortniteinminecraftt3794
@fortniteinminecraftt3794 9 ай бұрын
Yes
@HuaweiY-vo5pk
@HuaweiY-vo5pk 9 ай бұрын
😊😊😊😊😊oNfbhhkhggjg
@mikeross880
@mikeross880 9 ай бұрын
Nice! Now not only will New Years 2025 be louder but will be brighter as well. Also check out the wonderful portrait of The Queen by the annunciator near the end.
@spykillergames8402
@spykillergames8402 9 ай бұрын
Man all those strobes turned any fire drill into a rave
@dutchwolf2675
@dutchwolf2675 9 ай бұрын
Nice! really interesting old system! is the residential CO gonna get replaced for a notifier one? also why did the PA go off at 20:00? Keep up the great work. cant wait for the other videos
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
No the CO detector is not quite a residential one but it's not part of the fire alarm system and the school like many has bells for class change
@Skulldozer25
@Skulldozer25 9 ай бұрын
Beautiful alarm with bells, it's sad to see all of them will get replaced by l series, But the l series is my favorite alarm as well.
@Some_Random_Teen
@Some_Random_Teen 9 ай бұрын
You should make a wall of strobes to show the intensity of a couple hundred unsynchronized strobes going off all at once
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
That would be quite crazy for sure
@Williams_elektronik
@Williams_elektronik 9 ай бұрын
Yhea, for new year
@Neptunesalad12
@Neptunesalad12 8 ай бұрын
At max brightness setting or wha5
@pfefferwal
@pfefferwal Ай бұрын
no don't, someone might have epilepsy
@Some_Random_Teen
@Some_Random_Teen Ай бұрын
@@pfefferwal then they can make the wise decision not to watch the video that has the word strobe in the title and that has an epilepsy warning at the beginning
@The-creator-of-good-videos-15
@The-creator-of-good-videos-15 7 ай бұрын
1:42: I think NewAgeServerAlarm actually had that heat detector alarm. If I find a video of it, I’ll probably send the link. Or something…
@jomermalabanan7054
@jomermalabanan7054 Ай бұрын
I like how you always use the notifier when your replacing
@Max_And_His_Tech
@Max_And_His_Tech 9 ай бұрын
Thank you for showing us how to do these things
@IanGSully
@IanGSully 9 ай бұрын
At first when I heard about this replacement, I thought "Why is Nic's school district doing this school instead of Nic's old middle school?" But when you explained that they were building the new addition. Then it became a little more understanding, especially how the QS4 parts are discontinued. And no wonder because these things suck ass, that and they have been out for a while now. I mean, this one was a little better than the one at your middle school. Because the one at your middle school we all know likes to act drunk sometimes lol. But regardless this system is kinda interesting to learn about as well.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
The middle school actually has all of its parts there for the most part and they've been there well before they were here for the school they've actually been there longer than the previous two or three replacements that school is just waiting the longest for whatever reason
@IanGSully
@IanGSully 9 ай бұрын
@@nics-systems-electric Well yeah they just want people to suffer with the old "ShitStart" for a little while longer. When is that addition expected to be completed do you know?
@HenBasketFireAlarms
@HenBasketFireAlarms 9 ай бұрын
@@IanGSullyI thought the term was QuickShart
@IanGSully
@IanGSully 9 ай бұрын
@@HenBasketFireAlarms Well the official term is QuickStart, but I call it “ShitStart” because they suck
@omriboehm7180
@omriboehm7180 3 ай бұрын
I like how you say deleted to the fire alarm strobe 😂 6:20
@Calebs_clocks
@Calebs_clocks 4 ай бұрын
The school bell sounds nice NIC
@AabhavOwo7
@AabhavOwo7 5 ай бұрын
Is replacing new fire alarm strobes and detectors worth cheap to replace the old existing bells and candelas and smoke detectors
@Dawezil
@Dawezil 9 ай бұрын
Hey Nic is there any chance that if you get some of these old modules or stations i can maybe buy some off you?
@TheW.L.JenkinsCompany
@TheW.L.JenkinsCompany 9 ай бұрын
Love hearing that continuous sound!! Do you think it is better that the strobe lights are separate from the bell, or would it be more effective if there was a flasher on the bell?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
The strobes have to be separate from the bells as the bells do not have strobes on them like modern horn strobes do
@TheW.L.JenkinsCompany
@TheW.L.JenkinsCompany 9 ай бұрын
@@nics-systems-electric I was wondering how to get into contact with you and possibly supply some of our different bells. If you have an interest in how they are made you can always receive a tour. Would love to have you visit!
@rolandmcphail5060
@rolandmcphail5060 9 ай бұрын
in the gym, what are the cables for that are zip tied to the conduit? in the u.s, that's a code violation. but it is one of those things we do anyway, even though we know its wrong, myself included.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Speaker wire for speakers that are no longer there I'm not sure if it would be compliant or not would probably depend if the inspector was in a bad mood or not as you aren't supposed to use electrical equipment for a supporting device unless it's rigid conduit supporting electrical components but at the same time we are allowed to strap BX to pipe
@rolandmcphail5060
@rolandmcphail5060 9 ай бұрын
@@nics-systems-electric thats true, not heavily enforced here and not a safety hazzard unless there are a crazy amount of cables to weigh down and dislodge the conduit. also, may be fully legal in canada, im not at all familiar with your codes.
@rolandmcphail5060
@rolandmcphail5060 9 ай бұрын
@@nics-systems-electric ok, at first i didnt see the rest of your post, seems your code is similar to ours
@bluetheta
@bluetheta 8 ай бұрын
Does the company require you to recycle those old strobes? If not, paint the lens a different color per device and wire them together to make a super disco. You could start a DJ business.
@djbryce
@djbryce 9 ай бұрын
Another great video! I love the bells...just curious why they are being replaced since they clearly work well (and loud)? If it ain't broke... Looking forward to Pt. 2!
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
The strobes don't synchronize and to put horns in the classroom you would then have mixed signals which is illegal and you need to have devices that are listed as compatible with the sync modules and have available current data sheets
@clxdyy_
@clxdyy_ 9 ай бұрын
It's being replaced because they're constructing a new building, and with the EST QuickStart4, it has been problematic + unreliable, explaining why a replacement is necessary.
@omriboehm7180
@omriboehm7180 3 ай бұрын
what are those silver cover things that you put where the strobe was? 20:32
@nics-systems-electric
@nics-systems-electric 3 ай бұрын
Cover plates
@omriboehm7180
@omriboehm7180 3 ай бұрын
Oh okay
@Harper_DobniYT
@Harper_DobniYT 9 ай бұрын
I love the upgrade videos! Can’t wait for part 2!
@channeldeleted_2_3_678
@channeldeleted_2_3_678 9 ай бұрын
40:15, the letter O on the bottom right corner means that the zone is open and can't arm.
@thecomputergeek101old
@thecomputergeek101old Ай бұрын
Did you get to see the esa2000?
@christopherrios8393
@christopherrios8393 9 ай бұрын
Do you know if these customers ever complain about needing to upgrade the fire alarm systems? I've run into a lot of people who get upset that they need to repair, replace, or even install fire alarms because they've apparently never heard of them before. It's something that bothers me because they seem to not even care that these devices have the potential to save lives or upwards of millions of dollars in damages
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I guess you could say we are the customer as I am working as apprentice with the school district electrical department which is in house and we do the install with the fire alarm company who creates the program and supplies the parts. I don't have experience dealing with Non-government funded projects.
@Blue_spy1
@Blue_spy1 8 ай бұрын
Bro my school the 2nd and 3rd floor has 4 fire alarms in each hallway 1 in each bathroom 1 for each room 2 for the cafeteria 1 for the entrances
@cthomas1864
@cthomas1864 2 күн бұрын
What happened to the old bells and strobes?
@numatic12stan
@numatic12stan 9 ай бұрын
what model are the strobes, I'm thinking about buying one.
@AlphaCelebrities874
@AlphaCelebrities874 6 ай бұрын
*I wish I had the fire bell rather than the Honeywell Fire Alarm at my school.*
@jaybird2000
@jaybird2000 8 ай бұрын
Interested seeing the New System . 19:55 I heard a Bell in the background too. Im pretty sure its Bogen Multicom 2000.
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
Yes I believe so
@HenBasketFireAlarms
@HenBasketFireAlarms 9 ай бұрын
Nice video! I do wonder if the school was still for hard of hearing students, if the replacement audibles would have been low frequency, given that the 520Hz is more effective than 3kHz or broadband horns at alerting hard of hearing people
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Hard to say we don't even use them in sleeping areas at least none that I've seen
@HenBasketFireAlarms
@HenBasketFireAlarms 9 ай бұрын
@@nics-systems-electricInteresting, for how similar fire stuff is between the US and Canada in some places, they sure are different in many others
@mynintendogamingfeed5208
@mynintendogamingfeed5208 9 ай бұрын
That's awesome; can this building be compliant with our U.S. NFPA 72 code regulations in Canada? In addition, in place of the bells, the horn/strobe fire alarm notification devices could be useful there.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I'm not sure about the US codes it's CAN/ULC-S524 and some others that covers fire alarm installations in Canada
@JoshuaKing-qb4fj
@JoshuaKing-qb4fj 9 ай бұрын
39:23 that song was by an artist from the city i live in lol and then at the end nic was listening to gangstas paradise
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
You must be a Calgary guy next province over from me
@JoshuaKing-qb4fj
@JoshuaKing-qb4fj 9 ай бұрын
@@nics-systems-electric sure am
@whelenvortexr4
@whelenvortexr4 8 ай бұрын
I'll miss those old est strobes, I miss it when fire alarms were square and had vertical strobes. These the the Wheelock MT 24lsms
@s_boyd378
@s_boyd378 9 ай бұрын
all my schools are finally getting remodeled (the newest building is from 1976 and the oldest was from 1928 and it was knocked down)
@XxRoWCoAsTeRxX
@XxRoWCoAsTeRxX 9 ай бұрын
I am honestly really surprised that you swore😆
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Surprised? It's a constant problem I have
@siphonralarms9411
@siphonralarms9411 9 ай бұрын
@@nics-systems-electric I constantly swear as well, hence why I don’t normally talk in my videos lol
@ToothlessThedragon9
@ToothlessThedragon9 3 ай бұрын
@@nics-systems-electric Yeah and I've been thinking about a System Sensor to sound if he swears its like a censored or should I say System Sensored lol anyway I have thinking about a System Sensor as a censored beep sound but with the fire alarm sound
@jimmysullivan6054
@jimmysullivan6054 3 ай бұрын
@@nics-systems-electricsame 😂
@TheJakeman789
@TheJakeman789 9 ай бұрын
Nice upgrade, but if the old system still worked, what was the point of replacing. Fixing something that is not broken it seems.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I explained that in the video that it needs to be replaced for the expansion as they don't sell parts for it anymore and this particular panel is the next on the list for preventive upgrade as it's much easier to replace a system over spring break when you are prepared and the school isn't occupied versus it failing out of nowhere.
@achannelwithnopurpose1977
@achannelwithnopurpose1977 9 ай бұрын
Save as much as you can of the old stuff. Definitely don’t come across a setup like that much anymore.
@All_ConsumingBandu
@All_ConsumingBandu 3 ай бұрын
Nic be listening to black sabbath. Like that band?
@mds2465
@mds2465 3 ай бұрын
Wow I'm surprised to see that a building that was erected in 1994 does not have sprinklers. Idk what the laws are in Canada regarding fire code and safety regulations but here in the states it would definitely be a requirement today that's for sure.
@nics-systems-electric
@nics-systems-electric 3 ай бұрын
Wasn't required in that particular municipality until mid 90s I believe 96.
@robertbeyers1308
@robertbeyers1308 9 ай бұрын
Awesome video keep the good work up. But I do have a question for you. At timestamp 33:27 you show something unexpected. The question is what is beside you on your left side? Is that one of the spiders from the USA movie Eight Legged Freaks? If yes you'd better run away. 😅 We have to have fun here. So you're welcome for the unexpected laugh in this comment.
@siphonralarms9411
@siphonralarms9411 9 ай бұрын
Another school, another system to be replaced. Hopefully the wiring polarity won’t be a nightmare this time around…
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
This one was fine then again from 1994 so more recent
@jimmysullivan6054
@jimmysullivan6054 4 ай бұрын
I’m not a fire alarm tech or electrician but even I know that was messed up and confusing af
@FourtyFiftyEighty
@FourtyFiftyEighty 9 ай бұрын
30:43 is so relatable. Theres some systems or parts that people freak out over that are so garbage. Most recent one I did was a Siemens MXL. They suck
@whelenvortexr4
@whelenvortexr4 8 ай бұрын
My old high school has an MXL IQ and it's 24 years old and still works like a champ.
@DanTDMJace
@DanTDMJace 6 ай бұрын
@@whelenvortexr4modern mxls suck
@joshuamata6457
@joshuamata6457 9 ай бұрын
Did you keep any of the old one's
@michaelclark2022
@michaelclark2022 8 ай бұрын
I thought it was funny how there's a random duck chillin in the back 😂😂
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
lol seagull
@Camporito25
@Camporito25 8 ай бұрын
Hey, Nic, is this school right by your house? What's the location of the school in this video?
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
No the school by my house is a single floor sprinklered building with an addressable system
@Camporito25
@Camporito25 8 ай бұрын
@@nics-systems-electric What's the school's location on Google Maps?
@johannesjacobus6892
@johannesjacobus6892 7 ай бұрын
You guys finally got L series strobes,you only had smokes before
@handyfm
@handyfm 9 ай бұрын
Guarantee you’ve taken home at least one of those old bells :)
@GaryBeltz
@GaryBeltz 9 ай бұрын
Is this the school that you fid the annual in where you made a bunch of loud noises into the radio and the female electrician said "OK ots reset and that was close to my head!"?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Man I have no idea
@The-creator-of-good-videos-15
@The-creator-of-good-videos-15 7 ай бұрын
NIC guy, do you actually have an RC Quadcopter drone? If so, that is amazing!
@nics-systems-electric
@nics-systems-electric 7 ай бұрын
Yes I have a drone I've use it for a lot of my videos
@The-creator-of-good-videos-15
@The-creator-of-good-videos-15 7 ай бұрын
@@nics-systems-electric Oh, cool.
@thereal_jeremycraigbrown
@thereal_jeremycraigbrown 9 ай бұрын
Where do you guys take the old devices after replacing them?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I take some devices however most go in our metal bin or garbage bin
@numatic12stan
@numatic12stan 9 ай бұрын
what do you do with all the old devices????
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Usually they would be thrown out and recycled however I do take some of them as far as the stuff I actually want the rest gets recycled
@FireSystem45
@FireSystem45 9 ай бұрын
This is pretty cool. Do you know what they do with the old devices, besides throwing them out do you get to keep some? (Oh also, your videos made me realize this is literally my dream job)
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I kept some devices as usually they would be thrown out everything you saw in my SUV at the end of the video was stuff I took
@FireSystem45
@FireSystem45 9 ай бұрын
@@nics-systems-electricthat’s cool
@michaelloving8004
@michaelloving8004 9 ай бұрын
I guess that white plate next to the last strobe is a eol resistor plate in the gym
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Yes exactly
@ScantPear
@ScantPear Ай бұрын
I would have set all horns to high…
@nics-systems-electric
@nics-systems-electric Ай бұрын
We would have far too many complaints.
@MayaRana-p5e
@MayaRana-p5e 2 күн бұрын
Name. Denish. Rana
@chrisg6492
@chrisg6492 9 ай бұрын
Do you get paid to do this? Or is this volunteer?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Still a student so just doing it for apprenticeship hours not paid
@chrisg6492
@chrisg6492 9 ай бұрын
@@nics-systems-electric Student in what? Electrician?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@chrisg6492 yes
@All_ConsumingBandu
@All_ConsumingBandu 9 ай бұрын
I don't wanna be rude but on your channel I only see L series horns. I don't know if you heard of Wheelock but I like those more for whatever reason.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
We don't use wheelock but trust me I've heard of them usually replacing their broken products. system sensor has by far the best variety of options especially in a bilingual Canadian version and wheelock seems to suffer from quality issues more so therefore system sensor is what's typically used
@ryguy2006
@ryguy2006 9 ай бұрын
​@@nics-systems-electricthat's fair. System sensor has fairly good devices and a lot of customisability in terms of lettering and lenses.
@maiyo8518
@maiyo8518 9 ай бұрын
I like mechanical horn fire alarms
@peterking1134
@peterking1134 9 ай бұрын
What is SLC?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Signalling line circuit it is the data loop that the addressable devices communicate on
@SPCAlbanycounty536
@SPCAlbanycounty536 9 ай бұрын
Why are you using that thing on the bottom of the CPU last time at your high school that was making your system un synchronized I’ll probably go with a booster panel. I’m just saying I’m not trying to be rude.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
The only thing below the CPU is the power supply the system needs power to operate. The things that cause synchronization problems are the XP6-CA cards with sync-1A modules
@Planelover232
@Planelover232 9 ай бұрын
I’m excited for the test
@LazyMM2Dog
@LazyMM2Dog 8 ай бұрын
Can you like keep the old fire alarms or no.
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
Most stuff if it's actually worth keeping
@maxdutiel
@maxdutiel 9 ай бұрын
At the end of this saga, you should show how many Integrities you removed. Would be very interesting to see.
@maxdutiel
@maxdutiel 9 ай бұрын
Also, I do think that having AVs in the classrooms is a good idea in general.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Having devices in the classrooms is definitely good it means the corridor devices don't need to be as loud I think 65 or 70 strobes came out
@hotbytesB
@hotbytesB 9 ай бұрын
When are you going to post part two video?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Wednesday
@ryancrooks123
@ryancrooks123 9 ай бұрын
So Part 2 Of Replacing The Fire Alarm System Is Coming Out On Saturday
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
No next Wednesday
@mikesapienza1211
@mikesapienza1211 9 ай бұрын
Will they let you keep the devices you remove by chance?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
The stuff that I showed in my SUV at the end of the video was the stuff I kept not everything just some stuff I wanted
@Meepei
@Meepei Ай бұрын
Did you like working for the school District
@nics-systems-electric
@nics-systems-electric Ай бұрын
Yes mostly
@maxdutiel
@maxdutiel 9 ай бұрын
Is this William Isaac Shart?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
No
@major_lynx4746
@major_lynx4746 9 ай бұрын
how can we get the old stobles
@ToothlessThedragon9
@ToothlessThedragon9 3 ай бұрын
Whoa whoa whoa whoa whoa hey hey hey hey hey should that be censored as a fire alarm horn? 30:41
@MitchGaming381
@MitchGaming381 9 ай бұрын
Why the NFS2 3030 the NFS2-640 or NFS-320 would have done fine
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I suggest you watch the video and you will hear me mention what you have asked. the 320 as previous comments have said would not be large enough however as I said in the video a 640 would be sufficient
@SPCAlbanycounty536
@SPCAlbanycounty536 9 ай бұрын
What’s gonna happen to your job after you graduate high school?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I won't work with the school district anymore
@shuaybghaffoor3298
@shuaybghaffoor3298 8 ай бұрын
Just FYI…. 5:45 it’s a heat detector and at 5:47 that’s a smoke detector. You mixed them up.
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
That is not the case here you must be using different symbols than what we use. Not only in that physical location those are the devices that are installed but the legend also indicates what symbols are used for what devices and the way I described them is correct.
@shuaybghaffoor3298
@shuaybghaffoor3298 8 ай бұрын
@@nics-systems-electric I thought this was in Canada. I'm a CFAA certified fire tech here and those are how the smokes and heats are always shown. As long as that's what the drawings show you're good. Just wanted to point that out 👍
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
@@shuaybghaffoor3298this is Canada, but I can promise you where I said there is a smoke detector there was indeed a smoke detector in the corridors and where I said there was a heat detector in rooms that is true to out in the field. What was actually there
@shuaybghaffoor3298
@shuaybghaffoor3298 8 ай бұрын
@@nics-systems-electric Awesome, good to know!
@joeycaridi3030
@joeycaridi3030 9 ай бұрын
First time seeing you of the new things of this replacement 1. Replacing a an EST QuickStart 2. Installing a different Notifier panel which is the NFS2-3030 3. Installing a L-Series ceiling mount fire alarm and L-Series fire alarms of different customizations rather than P2RLs which are white ones and strobe only units
@Epicgames-mx2ov
@Epicgames-mx2ov 9 ай бұрын
Do you keep the strobes
@Epicgames-mx2ov
@Epicgames-mx2ov 9 ай бұрын
*?
@merc5codmobile
@merc5codmobile 9 ай бұрын
I have never seen an English and French lettering on that SCWL (pretty hard to find in the States actually)
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I've seen them all over the place they are nothing special to see here
@NS-Sirens
@NS-Sirens 8 ай бұрын
38:48 id love to buy one or two
@AabhavOwo7
@AabhavOwo7 5 ай бұрын
I believe putting new fire alarms is really cheap and worth it
@Skulldozer25
@Skulldozer25 8 ай бұрын
22:05 sideways integrity strobe #whatafirealarmfail
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
What makes it not listed for horizontal installation? There is no strobe coverage limitation due to horizontal placement.
@Skulldozer25
@Skulldozer25 8 ай бұрын
My bad
@michellebertrand7702
@michellebertrand7702 7 ай бұрын
30:38 Not everybody, I hate those exit signs.
@TransGalGaming
@TransGalGaming 8 ай бұрын
tighten your LP! that noise drives me bonkers lol
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
I'm not sure what you mean
@ItsKalle231
@ItsKalle231 9 ай бұрын
kinda sad to see that old system go and get replaced
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
This one's nothing to worry about just sounds like every other Canadian system from the last 50 years
@aerhardt
@aerhardt 9 ай бұрын
Yeah, it wasn’t really that old anyways. The new system will provide far better protection.
@mircomamsecosirensnalarms
@mircomamsecosirensnalarms 9 ай бұрын
Dangit i did not get 1st comment; But i am still happpy :D
@keithpierce8458
@keithpierce8458 9 ай бұрын
The est integrity’s are discontinued
@Warp2090
@Warp2090 9 ай бұрын
That old system seems more of a upgrade than the new one
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Did you watch the video?
@Warp2090
@Warp2090 9 ай бұрын
@@nics-systems-electric Mabye
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@Warp2090 then you will see the new system is a huge upgrade
@Warp2090
@Warp2090 9 ай бұрын
@@nics-systems-electric why not just mod
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@Warp2090 I'm not sure what you mean
@Jjkinnard
@Jjkinnard 9 ай бұрын
Can you sell some of those strobes for like 5 dollars I would gladly buy one
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Five dollars wouldn't even cover 25% of the shipping
@corbinplayzroblox9760
@corbinplayzroblox9760 9 ай бұрын
Nah he’ll never sell any of the strobes let alone for 5 dollars
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@corbinplayzroblox9760 I'd sell them if someone wanted them but I ain't going to lose money on it
@1bejarrr
@1bejarrr 9 ай бұрын
To replace these fire alarm do you guys need to power off the circuit
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Yes it's ideal to keep power on the circuits that way you can test the polarity when installing devices
@1bejarrr
@1bejarrr 9 ай бұрын
​​@@nics-systems-electricive been planning to replace the spectralert classic that is in my apartment unit with the new system sensor p4rl and the srl and idk if I could do it with the electricity on or I have to tell someone to turn it off for me that's my question
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@1bejarrr you don't in your apartment as that is illegal and if something was to happen whether it was your fault or not you could be held liable not something I would do in an apartment when your work could kill someone else and you weren't covered by anything
@1bejarrr
@1bejarrr 9 ай бұрын
@@nics-systems-electric what about calling someone or get the managers permission
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@1bejarrr I personally wouldn't want to take on that responsibility
@guptaland806
@guptaland806 2 ай бұрын
Something very bad happened are we went to Barstow at the haunted house and then there was fog machine and smoke detector and a keeps activating a fire alarm
@starlite528
@starlite528 9 ай бұрын
I'm really surprised you're setting the candela so high on all of these. Then again, you're in Canada and I'm in the US so different standards. EST Quickstart is a high priority pain in the ass, lol!. replace a device? re-do the mapping. Test the system? re-do the mapping. Don't have the software? Call a licensed dealer. Sheesh. I have a video of the strobes at my old high school going off, all unsyncronized. That system was installed in 1999, and has since been replaced. ( v=oTsmdsLy_uQ )
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Yeah usually we don't touch Candela however I asked and I was told to match the old devices. The mapping on Edwards is definitely a huge pain causes more problems than it solves. Luckily this one was conventional so didn't have that issue.
@mircomamsecosirensnalarms
@mircomamsecosirensnalarms 9 ай бұрын
when is part 2
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Wednesday
@f1fan112
@f1fan112 9 ай бұрын
Fire Alarm system designed for people that are hard of hearing getting replaced by a system with a ton of Spectralert Advances, a horn designed to make people deaf on high volume... LOL I kid I kid... It's better than the system we have in the school I work at, where the kids just laugh at the fire alarm because it's pathetically quiet and unintimidating.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
These ones are L-series but similar they are what replaced the advance and because of the amount in the school and having them in the classrooms we could set them all to low volume
@f1fan112
@f1fan112 9 ай бұрын
@nics-systems-electric I kind of figured that. Is my school has a variant of L-series, but they are all voice evac speaker strobes.
@TheMcGeeTwins
@TheMcGeeTwins 5 ай бұрын
I have a P2RL it is quite at low volume
@noahater5785
@noahater5785 8 ай бұрын
That looks like an absolute mess of electrical wiring 🤣🤣🤣
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
Not this school this one is pretty clean which makes the job much easier
@Max_And_His_Tech
@Max_And_His_Tech 9 ай бұрын
First
@mircomamsecosirensnalarms
@mircomamsecosirensnalarms 8 ай бұрын
NFS2 3030
@wibwabz
@wibwabz 9 ай бұрын
why is the light pull station next to you in this video flashing so fast? [ kzbin.info/www/bejne/sJPShaOCbaitp7s ]
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I'm not sure what you are referring to as your link goes to a different video
@wibwabz
@wibwabz 9 ай бұрын
@@nics-systems-electric yes, i am talking about the video the link goes to.
@ThaCowPuncher
@ThaCowPuncher 4 ай бұрын
Why l sieries
@nics-systems-electric
@nics-systems-electric 4 ай бұрын
That's system sensors's newest product line and what they sell
@ThaCowPuncher
@ThaCowPuncher 4 ай бұрын
@@nics-systems-electric but they're boring
@nics-systems-electric
@nics-systems-electric 4 ай бұрын
@@ThaCowPuncher it's a fire alarm system it's not supposed to be interesting
@MichaelKsAlarms
@MichaelKsAlarms 9 ай бұрын
Can i have the old panel please
Testing Fire Alarm System in a Brand New School addition Expansion
8:43
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 3,6 М.
Cat mode and a glass of water #family #humor #fun
00:22
Kotiki_Z
Рет қаралды 42 МЛН
Replacing fire alarm system at elementary school. Full addressable replacement day #1
26:15
Was that a lockdown or a false alarm? (September 26, 2024)
7:06
Fire Alarm Compilation
23:25
dewpoint8900
Рет қаралды 136 М.
Addressable vs Conventional Alarm Systems
7:20
GPSTC Productions
Рет қаралды 49 М.
Basement Fire System Test 31 | Faraday Mechanical Horn Strobes
16:19
FireAlarmDude5967
Рет қаралды 25 М.
Fire alarm testing/verification of brand new notifier install at Elementary School
48:51
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 21 М.