A lot of thanks Respected Sir , Just because of you I learnt this much about CTB.
@SatishIITR25 күн бұрын
Really happy to see that it was helpful. Keep watching
@peshawargoats34112 ай бұрын
Super explanation
@SatishIITR2 ай бұрын
Thank you 🙂
@AllinOne-kg5hf10 ай бұрын
Most beautiful explanation
@SatishIITR10 ай бұрын
Thanks a lot 😊 Keep watching
@civillaboratorytest10 ай бұрын
Your explanation is very good sir I always saw your video
@SatishIITR10 ай бұрын
Thanks and welcome
@SatishIITR10 ай бұрын
one correction at 1.47, the laboraroty strength should at least be 1.5 times the minimum field UCS stipulated in the contract.
@yasawantsinghyadav240610 ай бұрын
Sir bhut acha teaching krate hi ap 🔥🔥
@SatishIITR10 ай бұрын
धन्यवाद
@mscivilconstruction233810 ай бұрын
sir thanks for in hindi well done sir
@SatishIITR10 ай бұрын
So nice of you. Keep watching
@surajpudke56869 ай бұрын
Good explanation sir.
@SatishIITR9 ай бұрын
Thanks for liking. Keep watching
@enricoshira70132 ай бұрын
Sir can you please explain which quality control checks are to be conducted for CTB layer at field and how those QC tests at field are carried out?
@SatishIITR2 ай бұрын
watch this video. kzbin.info/www/bejne/iXzQfZKOjdZ2e8U I have uploaded three more videos on quality controls
@gvarun21928 ай бұрын
Sir, Thanks for the video and share the procedure for casting of Cubes for CTSB. If possible Pls make a video of difference between compressive strength and UCS...
@SatishIITR8 ай бұрын
Will prepare a video on CTSB soon.
@daksheshwar91088 ай бұрын
Respected Sir, Just like you have explained CTB to us so well, why don't you make a video for CTSB also and explain it to us better.
@SatishIITR8 ай бұрын
Ok, will do
@daksheshwar91088 ай бұрын
Dear Sir, I'm a big follower of yours. You had designed the bituminous, base & sub base of our pwd project for the last 10 years ego. During that time, I'm in CEC Company. From your videos, we have got a lot of deep knowledge, and a lot of concepts have become clear.
@SatishIITR8 ай бұрын
Thank you so much. Ab aap kis company ke saath hai? I had gone to CRRI as Director for 6 years, now back in Roorkee. Come to IIT whenever you happen to be this side.@@daksheshwar9108
@daksheshwar91088 ай бұрын
Dear Sir, Right now, I am in Dinesh Chandra R.Agrawal Infracon Company, and my project is Delhi-Mumbai Expressway. It will be my good fortune to get a chance to meet you.
@civillaboratorytest10 ай бұрын
Respected sir I request you that please make video for testing because many engineers no information that what porpuse of test
@SatishIITR10 ай бұрын
Do you mean testing of soil, aggregates and bitumen?
@civillaboratorytest10 ай бұрын
@@SatishIITR yes sir
@TarifKhan-fx7ng3 ай бұрын
Sir pls CTSB PR EK VIDEO JARUR. BNA DIJIYE HINDI ME
@SatishIITR3 ай бұрын
Okay
@civillaboratorytest10 ай бұрын
Make a video for concrete mix design
@SatishIITR10 ай бұрын
It was uploaded last Sunday only. watch it and give your feedback.
@kunalpandey622110 ай бұрын
❤
@SatishIITR10 ай бұрын
Thanks
@sujitdhital228410 ай бұрын
Sir is it 1.1 time or1.5 time the field strength.
@SatishIITR10 ай бұрын
Thanks Sujit ji, it is 1.5 times.
@parasmanisindhia449310 ай бұрын
Sir, is there any video in IRC SP 59 2018
@SatishIITR10 ай бұрын
No, I have not uploaded yet.
@daksheshwar91088 ай бұрын
Dear Sir, If the strength can be anything between 4.5 Mpa to 7 Mpa, the contractor will always take 4.5 Mpa, then when and under what condition will we take the strength of 7 Mpa ?
@SatishIITR8 ай бұрын
I have faced this question earlier also and I do not have straightforward answer here. In any case the mix is to be designed in the laboratory and the lab strength should be 1.5 time the required minimum field stregth. Therefore nothing to worry. In case you want more strength than 4.5 MPa, make it part of your contract document. In case of stabilized material, the strength keeps on increasing with time.
@daksheshwar91088 ай бұрын
Dear Sir, There can be a question of some error/miss concept, because after multiplying the strength of 4.5 Mpa by the design factor it comes to nearly 7 Mpa (4.5 x 1.5 = 6.75 Mpa) . What can be said that field strength is 4.5 Mpa and design strength is 7 Mpa ?
@daksheshwar91088 ай бұрын
Dear Sir, It is quite possible that I am wrong according to the IRC standard, but this is how I understood it and I have implemented it on the project in such a way that 4.5 Mpa will be the field strength and 7 Mpa will be the design strength. Because technically this is not wrong, I feel like this in Confusion in CTSB too, that's why I requested you to make a video on this topic too.
@SatishIITR8 ай бұрын
Incidently your answer is correct, but pocedure is not.@@daksheshwar9108
@Dhananjaykumer10 ай бұрын
Sir CTSB mix design
@SatishIITR10 ай бұрын
CTSB ka as such koi design nahi hai.
@Dhananjaykumer10 ай бұрын
@@SatishIITR CTSB mix design
@SatishIITR10 ай бұрын
CTSB ka mix design bhi bilkul aise hi kiya jata hai. sirf UCS ki requirement change ho jati hai.@@Dhananjaykumer
@mscivilconstruction233810 ай бұрын
sir dlc design in hindi
@SatishIITR10 ай бұрын
Already uploaded. watch here 7. Dry Lean Concrete: kzbin.info/www/bejne/m2eZgmutoq96orc