Just passed my first lot exams and I’m still watching your videos! Great stuff! 👍
@tomkatgastraining4 жыл бұрын
Well done good luck with the rest 👍🏻
@rsderham3 жыл бұрын
Thank you for going to so much trouble to produce this video, I found it extremely informative and interesting. Good work!
@phoneblaster Жыл бұрын
...another great video Derek, Well done and Kudos for all the hardwork you put in.
@just2preeyt3803 жыл бұрын
Mate your wicked You have been a big help I’m going to watch them all everyday Has done so much god bless ya
@mossmm732 жыл бұрын
Very informative Good way of presentation Covered range of gas meters to be found regularly
@nickshelley5370 Жыл бұрын
Another fantastic video! Derek you are a legend
@illuminate06 Жыл бұрын
I'm assuming that the bonding qualification is PEB1? Will this course just allow me to move, alter or extend not install if the bonding is missing?
@tomkatgastraining Жыл бұрын
I believe it allows gas engineers to install but we don’t run this course so not 100%
@WeShowMemes5374 жыл бұрын
An excellent lecture about gas meter and safety measures related with it 👍 sir chairs
@michellecassar57852 ай бұрын
We've got lead at a job going to next week so thank you for the tips.
@colinmckay63735 ай бұрын
Ive got a little question i am currently doing my training, if you attend a job and tightness test and it drops, you then carry out all your tracing tests and this leads back to the meter. You then installing a sealing disc and confirm meter is leaking. Do you contact emergency number or the customers gas supplier to repair/or replace meter? Thanks
@themadhatter47614 жыл бұрын
Excellent informative video thanks for taking the time to make it 👍👍👍
@BarriosGroupie Жыл бұрын
Very clear and informative! So let's say an energy company, such as British gas, wanted to install a smart gas meter in a residence and asked you to provide an update for the service pipe energy value, SPEV, for the residence beforehand: (a) Would you go through this same procedure using the diversity chart? (b) What sort of documentation/form would an energy company expect from you as a gas safe engineer?
@stevenyates67326 ай бұрын
I have seen meters under a kitchen sink a few times, in fact I had corgi inspection with one under sink.
@johannamoreira628810 ай бұрын
Hi can I install a boiler above a gas meter... a meter apart?
@piotrmarchwacki34144 жыл бұрын
Thank you very much Derek. Very useful video, full of information. 👍😃
@grzechotnik1083 жыл бұрын
Can I test the resistance of the equal potential bonding to get to know if this works fine? What would it be the value I should get?
@Rigden19744 ай бұрын
Very easy to understand thanks Derick 👍
@martynlewis59014 жыл бұрын
Corrosive atmosphere? Recently had a meter installed in the cellar of an old terraced property, a common enough type of installation you come across all the time. I was there to do a landlords inspection, I found a gas leak coming from the gas meter case where condensate water had eaton through it. This cellar was dripping with condensation all the time according to the tenant, contacted the gas supplier who just came out and replaced the meter in the same location.
@TW-mp8zx2 жыл бұрын
Hi derek, hopefully you have time to help clear this up for me, Been to a flat to do a landlord check, found the newish boiler to be enclosed in an accessible stud tiled void built onto the external wall this enclosure also has an old gas meter inside, both the boiler and meter is accessible via the bathroom on the same wall as the bath/shower.. would the gas meter be in a NCS situation? And also would this installation be classed as within zone1 of the bath/shower. Im thinking because its enclosed perhaps its now not within any zone in that bathroom? Any help would be great as not come across this scenario before thanks and love the videos
@moulesanctuary4 жыл бұрын
Absolutlety brilliant mate ... doing my ACS on 7t hDecember .. never even heard of diversity calculation !!! Keep thees vids coming
@tomkatgastraining4 жыл бұрын
Good luck with your ACS let me know how you go on 👍🏻
@History-Of-The-Day Жыл бұрын
Are these all different from what's used in the United States? I rent my home. No training at all. But I've never seen any of these type meters
@kortrijk056 Жыл бұрын
i have a u6 meter but need an u16, does the pipework coming to the meter from outside need to be changed
@tomkatgastraining Жыл бұрын
A possibility yes
@robertmoughtin64214 жыл бұрын
Thank you for this excellent video on gas meters if you found a gas meter already installed under a kitchen sink what procedure would you carry out please
@tomkatgastraining4 жыл бұрын
You don’t do anything only make sure you keep food and chemicals away from the meter it is classed as not to current standards
@aaronharris5275 Жыл бұрын
Hello, I'm doing the interior architecture designs and basically asking for help. I'm listening to your video. So an electrical consumer unit can be as close as 150mm? If the meter is in a wall cabinet with a removable back. Would this cause issues with obstruction and delaying access to the emergency shut off valve? Thanks Aaron
@billyt99212 жыл бұрын
seems to be some debate about which side of the spigot gets sealed up with flue jointing compound. some say to seal the meter cupboard side, some say to seal the property side, and others say both. what's your take on it?
@tomkatgastraining2 жыл бұрын
The meter cupboard side should always be sealed
@7KIslands11 ай бұрын
Can a Gas engineer relocate the gas meter or do i have to call the provider ?
@theresachiorazzi45713 жыл бұрын
What do you think about them being out doors.
@tomkatgastraining3 жыл бұрын
They are only allowed outside if they are in a weather proof box in the U.K.
@paul_my_plumbs_uk Жыл бұрын
Just done my gas meter assessment 🎉🎉 what paperwork is required after the exchange and purge please??? Only doing an ACS write up😅😅
@DONALD19514 жыл бұрын
Is that sweated copper on the outlet side of the meter? It’s not allowed in the US.
@wakefieldyorkshire4 жыл бұрын
The gas tightness test with appliances connected, is there a time period allowance for the permissible drop to stabilize.
@tomkatgastraining4 жыл бұрын
That’s what the temperature stabilisation period is for 👍🏻
@icanfly22452 жыл бұрын
Do the Gas inlet and out let pipes to the meter need rubber rings? I see one by the meter but don't know if they belong to either one of the pipes? Or do they not belong on a meter?
@tomkatgastraining2 жыл бұрын
The video is filmed in a gas training centre so no need to worry but yes the meter needs rubber rings as you put it
@icanfly22452 жыл бұрын
@@tomkatgastraining cheers, I won't throw it out just incase it's needed when the plumber gets here
@ILLYRIANW0LF4 ай бұрын
A question, Can the outlet pipe run through the side of the gas meter box ?
@tomkatgastraining4 ай бұрын
@@ILLYRIANW0LF no
@ILLYRIANW0LF4 ай бұрын
@@tomkatgastraining thanks 👍
@naturelover_92114 жыл бұрын
Thank you Derek for detailed video about gas meters.
@darranhusaen1563 жыл бұрын
Thank you very much , Always enjoy and very informative your videos..
@hrgh4538 Жыл бұрын
Another brilliant lesson
@mohammednazir83073 жыл бұрын
Another real good video especially the area you talked about the surface mounted meter box being damaged (At Risk under IGEM/G11) and earth bonding. Thanks Derek. Trainee at tomkat gas training center..
@avajoshua90852 жыл бұрын
Hi, thanks for the vid. Who could tenants direct queries about gas meters to? I’ve used expanding foam to seal the hole where the green/yellow wire goes through the wall and I want to know if it’s now a risk
@tomkatgastraining2 жыл бұрын
Always your landlord first
@avajoshua90852 жыл бұрын
@@tomkatgastraining Thank you. Will ask first thing Monday. Much appreciated:)
@andrewthomas3324 жыл бұрын
Super Video Derek. Question . Regards the meter ECV what's AR in none emergency situation ? then ID in emergency situation Thanks for the graft doing these videos tons of useful info on this one.
@tomkatgastraining4 жыл бұрын
Get called to install a gas appliance and you can’t get at the ECV then AR get called to a gas escape and can’t get at the ECV then ID
@andrewthomas3324 жыл бұрын
@@tomkatgastraining much appreciated
@1Monaghan4 жыл бұрын
Hi Derek Something not mentioned is shear bolts and washers. It’s my understanding you have to disconnect and remove a meter in order to solder new pipework in for example to a new appliance. Do these get in the way how are they removed? Do they need to be replaced afterwards? Thanks!
@tomkatgastraining4 жыл бұрын
I think if you watch the video again I mentioned shear bolts and why they are needed. When removing the meter which I didn’t go through for obvious reasons the regulator and meter union don’t need to be removed. Thanks for watching cheers
@1Monaghan4 жыл бұрын
Oops. You did indeed it’s at 9:45. Thanks!
@tomkatgastraining4 жыл бұрын
@@1Monaghan 🤣🤣🤣👍🏻
@jaimedamascena11422 жыл бұрын
What's permissible pressure drop on G470 671 gas meter with 22mm existing pipework and boiler please.
@estherabwa99602 жыл бұрын
Where can I submit my meter readings???
@modelsandtrains79152 жыл бұрын
Quick question I’m thinking of going from normal gas meter to a pay as you go……. Is the digital display battery powered or hard wired to mains?
@tomkatgastraining2 жыл бұрын
Battery
@cjmillsnun2 жыл бұрын
"Now this one is a G4 gas meter" Shows picture of a U6 (hint it even says U6 on the meter itself). U6 meters can read in either cuft or m3.
@gushbucket59985 ай бұрын
Great video and loads of help 👍🏻
@deniswatfordsmart10493 жыл бұрын
Absolutely banging 👍well done !
@brendanfisher25284 жыл бұрын
what about exsisting meters? 80% i go to are under kitchen sink or in utility with food storage
@tomkatgastraining4 жыл бұрын
NCS then
@patrickbradley82432 жыл бұрын
thanks for the amazing content. do you offer courses on installs of boilers at all?
@tomkatgastraining2 жыл бұрын
We do the ACS mlp and reassessments water regs and g3 unvented. Coming soon we are doing plumbing and air sources heat pumps.
@samchappell2333 жыл бұрын
brilliant video again👍👍
@adamburzynski4 жыл бұрын
Good video. How would you identify a medium pressure meter and regular? I've only seen low pressure.
@tomkatgastraining4 жыл бұрын
The little green leaver is only on medium pressure and there will be the MIV on most of them
@vussprungteknik33374 жыл бұрын
Do you do the EUSR course derek
@mac-yo2xs2 жыл бұрын
With the rise in gas prices is it possible to fit lpg direct to gas meter instead of from supplier? I want to cap their input and replace with lpg instead... Any advice?
@tomkatgastraining2 жыл бұрын
Noooooooooooooo you will need a gas engineer with lpg qualifications to change all the appliances over if they can be and install a new system of gas supply
@mac-yo2xs2 жыл бұрын
@@tomkatgastraining thanx for that.... I've just had notification gas and electric are going up £400 average.....
@mohammednazir83073 жыл бұрын
Brilliant video Derek. Thanks mate 😁
@vussprungteknik33374 жыл бұрын
What training book is the best? Do any do an A4 format like the old city books? Miss them
@tomkatgastraining4 жыл бұрын
They all give the same information but use the one from your training provider as the exams are taken from it
@miransalih10798 ай бұрын
Thanks Derek, I've My Acs in next 6 weeks. I'm more confident in the practical bit, but more nervous about the theory and paper questions. Apart from reading a books, what's your advice regarding the theory? Thanks
@tomkatgastraining8 ай бұрын
Watch my videos on ACS revision 😜
@miransalih10798 ай бұрын
@@tomkatgastraininglol, No doubt about that ha, English being my Third language makes it difficult for me at the theory bit, slow reader. Any advice on that please? 🫣
@tomkatgastraining8 ай бұрын
@@miransalih1079 reading your training manual and remembering where the different sections are will help you reference the questions quickly
@miransalih10798 ай бұрын
@@tomkatgastraining thanks for advice, but when you said training Manual you meant the books? And I'm working on the sections.
@tomkatgastraining8 ай бұрын
@@miransalih1079 yes 👍🏻
@d055e4 жыл бұрын
Hi the g10 bkt, is that acceptable?, I’m currently on a new install with the same shelf type bkt, but the meter can still move on that?, transporter hasn’t attached it to the box and bg fitted the meter and they won’t attach it in place either as they won’t perforate the box🙄, the usual nonsense going on, any info appreciated cheers
@tomkatgastraining4 жыл бұрын
Yes the bracket is acceptable and the only bracket I know of for u16 or g10 there is also the meter box of course
@d055e4 жыл бұрын
@@tomkatgastraining cheers bud, I’ll get it affixed then and be happy with that for connection, much appreciated!
@herr_crustovsky3 жыл бұрын
Hi! I have a gas meter in my room in a cupboard and it kinda smells, is it detrimental to your health to smell gas? What are the risks? It's not a big leak since I had naked flames around that spot and nothing happened, but I can still smell it pretty bad in the cupboard and around it. Thank you
@egzonmorina41622 жыл бұрын
I hope your still alive.
@herr_crustovsky2 жыл бұрын
@@egzonmorina4162 yeah, I moved out of there recently, thanks! :)) I had someone come and take a look and they said it actually was a leak, but not enough to blow up, he tightened something up and the smell stopped.
@unluckylemon6 ай бұрын
going to have me acs reassements, lol booked it with them, and watching there videos, crazy
@leaturk113 жыл бұрын
Top training, well done sir.
@jasonoliver95493 жыл бұрын
So you can't have a meter in a food larder? Where I live the whole estate has them in the kitchen later? What is this classed as as its a new 9ne 9n me
@tomkatgastraining3 жыл бұрын
NTS or AR if it is showing signs of corrosion or ID if leaking gas
@richardhorton-bradley48902 жыл бұрын
My mother's gas meter has just been fitted with a new regulator by Cadent gas after the boiler engineer issued a danger do not use certificate as he had recorded low pressure on the system. The gas meter is situated under the kitchen sink and as per your video, this is not to current standards. the gas meter has been there since at least 1980 if not before. Should the gas meter be relocated and at whose cost would this be?
@tomkatgastraining2 жыл бұрын
No the gas meter won’t be relocated but chemicals should not be stored with the gas meter
@fjrxj11346 ай бұрын
Hi Derek, I completely agree with your comment that gas meters shouldn't be installed under kitchen sinks. However, I raised this issue with Gas Safe following an incident, and they confirmed that no regulations explicitly prohibit the installation of gas meters in that location. They stated that a gas meter should not be placed under a kitchen sink only if the environment is proven to be damp and mouldy. I can email Gas Safe's response to you if you'd like, but I fully agree with your perspective.
@tomkatgastraining6 ай бұрын
@@fjrxj1134 damp and mouldy did they not mean if food or corrosive chemicals are stored ?
@dominicforge88994 жыл бұрын
I work for a utility company that is planning to replace the gas supply to a block of flats, the plan is to abandon the old internal riser and replace it with an external steel riser which will branch off into each flat. The planned location for the new ECVs is in the kitchen cupboards under the sink which would obviously mean that the meter would also have to be relocated into the same cupboard. Am I understanding you correctly that this is not allowed?
@tomkatgastraining4 жыл бұрын
If you read the British standards it tells you the locations not to use and they class under the sink as I place not to use because of cleaning chemicals. In this situation it would be better to install the meters at ground level in meter boxes and put AECV into the flat. I have never come across a supply who would put the meter in that location but there’s always a first time
@irj0000 Жыл бұрын
@@tomkatgastraining Used to fit gas meters for MacAlpines/British gas and Enterprise/National grid and one of the most common internal siting up in West Yorkshire is in the cupboard under the sink lol
@jamesmcgilvray63633 жыл бұрын
Brilliant and informal as always
@Browngeezer2 жыл бұрын
What’s the blue thing on the meter
@Ultimatephysiquept3 жыл бұрын
Is this what you’d expect in a Met1 assessment? Great video
@tomkatgastraining3 жыл бұрын
Pretty much yes
@johnblanning25002 жыл бұрын
Really clear and instructive video.
@isaurajohnston74783 жыл бұрын
Love your videos, but the first meter say u6 and you call it and g4 any reason for that?
@tomkatgastraining3 жыл бұрын
Because it’s a g4 meter the u 6 on the meter is not the type. We call a u6 meter the one that is in ft3 and a g4 in m3 and this meter is in m3
@davidjeffreys90638 ай бұрын
When the music started at 2:47, i thought it was the start of Crossroads
@shaq12 жыл бұрын
The outlet of my gas meter is lead and has this white powdery stuff around it, is this normal?
@tomkatgastraining2 жыл бұрын
That’s lead oxide or the lead corroding
@shaq12 жыл бұрын
That was a fast reply thanks, is it ok or should I get it checked out? Thank you
@tomkatgastraining2 жыл бұрын
@@shaq1 if you can smell gas get it checked out
@shaq12 жыл бұрын
@@tomkatgastraining I will do thank you.
@henri93094 жыл бұрын
Nice video, thanks. Who owns or is responsible for the meter box? It might be useful for newbies to know who owns what on the gas meter too.
@tomkatgastraining4 жыл бұрын
The meter is owned by the gas suppliers and the meter box is the responsibility of the house owner so if the ECV, anaconda, regulator or meter needs replaced then the supplier picks up the bill but the box is the house owner’s problem
@cjmillsnun2 жыл бұрын
@@tomkatgastraining Kinda, You're correct in that the supplier is responsible for the gas meter, but it is owned by a Meter Asset Manager (National Grid Metering, SGN Metering and SMS are 3 examples) - otherwise you'd be looking at a meter change with every supplier change - which isn't feasible. The regulator and anaconda (they are a single assembly) are usually owned by the MAM as well. The service pipe and ECV are owned by the Gas Distribution Network (either Cadent, SGN, Wales & West Utilities, Northern Gas Networks or one of the plethora of IGTs) and the meter box is owned by the house owner.
@garethhartland5332 Жыл бұрын
I work for a smart metering company, the door and lock are the responsibility of the homeowner/landlord the easy bit. It gets tricky when the bracket is damaged, my company policy is we change the bracket, which I think is wrong however the regs state no operative shall drill a meter box other than the approved entry points. Because if it’s a inset meter box the gas supplier would need to remove the main service pipe to fit a new rear box. So should it be the supplier who repairs the box and not the meter operative??
@peterbattey82635 ай бұрын
How does my meter know which gas in the gas main is the one that I'm paying for? As my next door neighbour is connected to the same gas main in the street yet pays less for her gas? How can this be as there is only one gas pipe in the street. I know this as I saw them install the pipe in the road. Surely my next door neighbours gas must be different if she pays less, so how many gases are travelling in down the pipe and how does my meter know which one is mine and not my neighbours. If the gas is the same for both of us why am I paying more??
@tomkatgastraining5 ай бұрын
You are billed from the gas you use through your meter it make no odds how many are fed of the main. You can have a higher bill than next door because you are using more than them or you have a different supplier
@peterbattey82635 ай бұрын
@@tomkatgastraining what I am saying that every supplier pays exactly the same price for the gas they buy, it comes down the same pipe yet when it reaches the meter the price changes. Why?
@tomkatgastraining5 ай бұрын
@@peterbattey8263 there is the gas transport and gas supplier you buy off the gas supplier.
@peterbattey82635 ай бұрын
@@tomkatgastraining in other words there are too many fingers grabbing a small pie. Don't come up with the saying that if it were all under one roof it would stifle competition that's a myth, as nearly all the UK's utilities are already owned by a few select companies who are now far too big to be taken down and stifling competition anyway. Same with transport system that along with utilities is foreign owned. Britain is finished as a global influencer. The Golden geese lay golden eggs for other people.
@javed30064 жыл бұрын
Brilliant video derek always 5/5 👍
@OGMagic3 жыл бұрын
What do the red numbers mean on a (UGI) meter?
@irj0000 Жыл бұрын
Fraction of a full unit
@underdogunchained2 жыл бұрын
I don't want a smart meter installed at my domestic property. Can one purchase their own U6 or G4 meter and get it installed by an independent qualified gas engineer?
@tomkatgastraining2 жыл бұрын
You don’t have to have one. Just tell your supplier you don’t want one
@underdogunchained2 жыл бұрын
@@tomkatgastraining I did. They won't install anything other than a smart meter. They are under pressure from OFGEM to meet targets to install them or risk a fine. That is why I asked if it's possible for me to purchase one and get it installed by an independent qualified gas engineer?
@tomkatgastraining2 жыл бұрын
@@underdogunchained at the end of the day all a smart meter dose is tell you how much gas you are using and sends the readings to the supplier so they don’t have to send anyone around to read it .
@underdogunchained2 жыл бұрын
@@tomkatgastraining I understand the selling point of convenience. I still do not want one. I want to own my own meter. Is it feasible to purchase one and get it installed?
@tomkatgastraining2 жыл бұрын
@@underdogunchained you can but you will need to find a supplier who will just take the readings of the meter and not want to put a smart meter in
@osmelmuhendislik8073 жыл бұрын
can we use anacondas on the pipe work? (e.g inlet of the boiler or any gas appliance or middle of the pipework)
@tomkatgastraining3 жыл бұрын
No the anaconda is designed for the meter but you could use tracpipe or gastite pipe on the installation
@osmelmuhendislik8073 жыл бұрын
@@tomkatgastraining Thank you very ı am grateful
@monikanader94544 жыл бұрын
Very informative video👍
@Gbgasassessoria4 жыл бұрын
work with gas installation here in Brazil thank you 18/11/20 as 11:54
@ladylianmey61174 жыл бұрын
My name is Dian Pelangi from Jakarta in Indonesia, I am a fashion designer and I want to use this media to tell everyone to be careful about getting loans on the internet, so many lenders here are fraudsters and they are here. tricking you with your hard-earned money, I applied for a loan for around Rp900,000,000 women in Malaysia and I lost around 29 million without taking a loan, I paid almost 29 million still I didn't get a loan and my business was about crashing because of debt. When I searched for a reliable private loan company, I saw another online advertisement and the name of the company was THE WORLD LOAN COMPANY. I lost 15 million with them and to this day, I have never received the loan I proposed. Dear God, my friends who applied for loans also received the loans, introducing me to a trustworthy company where Mrs. Christabel worked as a branch manager, and I applied for a loan of Rp900,000,000 and they asked for my credentials, and after that they finished verifying my details, the loan was approved for me and I thought it was just a joke, and maybe this was one of the cheats that made I lost money, but I was stunned. When I get my loan in less than 6 hours with a low interest rate of 2% without collateral I am very happy that God used my friend who contacted them and introduced me to them and because I survived making my business soar high in the air and liquidated and now my business is flying high in Indonesia and no one will say it. know about fashion companies. So I suggest all people who live in Indonesia and other countries who need loans for one purpose or another to contact christabel mother via email: christabelloancompany@gmail.com You can also contact me at my email: (lianmeylady@gmail.com) and Sety introduces and talks about christabel, she also gets a new loan from christabel, you can also contact her via her email: permatabudiwati@gmail.com Now, all who will I do is try to fulfill loan payments that I send directly to their account every month. A word for wise men is enough Thank you once again for reading my testimony, and may the Lord continue to bless us and give us a long life and a prosperous life and may God do the same good work in your life. Good mother Christabel Missan What'sApp number +15614916019
@threeinone69773 жыл бұрын
Thanks for this very interesting, can you tell me the standard text books for gas installation?
@tomkatgastraining3 жыл бұрын
We use the logic training manual but there are lots of books out there
@threeinone69773 жыл бұрын
@@tomkatgastraining Thanks!
@rivkiroyde43624 жыл бұрын
Thanks Derek great video 🙏🙏🙏
@darrenmeears46674 жыл бұрын
Can you show us how to fiddle the meter 😲✌
@onefortheroad12 жыл бұрын
Why do we need an additional test point after an AECV?
@tomkatgastraining2 жыл бұрын
To test pipe work after aecv
@onefortheroad12 жыл бұрын
@@tomkatgastraining you would do that at the meter though? And you would always need to access the meter when working on an appliance for gas rate etc?
@tomkatgastraining2 жыл бұрын
@@onefortheroad1 nope what if you are working in flats with one commercial meter
@onefortheroad12 жыл бұрын
@@tomkatgastraining I’m talking domestic though. If they have a boiler within each flat, is there still a requirement for an additional test point?
@tomkatgastraining2 жыл бұрын
@@onefortheroad1 yep
@solagesture.99823 жыл бұрын
Mine was installed under the sink cabinet where I put the washing stuff
@stewartharrod85624 жыл бұрын
Brilliant video thanks/ keep them coming
@arelectricalknowledge32824 жыл бұрын
Owsm video sir❤️❤️❤️ #Ar_electrical_knowledge
@jamesmibiker12373 жыл бұрын
How can I make mine leak to get it moved outside
@barrydoherty6364 жыл бұрын
Great video, well done.
@mj0n4id363 жыл бұрын
So much info on meters covered brilliantly in such a short period of time. Is lead lock only for domestic incoming water supply then? Great video Derek 👍🏻 Asian Jon. Training.
@tomkatgastraining3 жыл бұрын
Yes mate it is
@mj0n4id363 жыл бұрын
@@tomkatgastraining Thanks!
@robdegoyim40234 жыл бұрын
Doing my ACS next week, any tips?
@tomkatgastraining4 жыл бұрын
Watch my videos and good luck 😜👍🏻
@robdegoyim40234 жыл бұрын
Tomkat Gas Training haha thanks!
@robdegoyim40234 жыл бұрын
@@tomkatgastraining I passed mate, thanks!
@estherabwa99602 жыл бұрын
I have read meters already and just want to submit the readings so that I can have my bill.
@salvopalali52062 жыл бұрын
Many thanks for sharing these videos
@loverandjoy Жыл бұрын
Think your allowed an anaconda pipe on inlet and outlet on some semi concealed gas meter.
@tomkatgastraining Жыл бұрын
Correct 👍🏻
@aghasahib47033 жыл бұрын
During a gas rate an imperial meter takes 38 seconds to complete 1 revolution. How many m3/h of gas has been burnt? (answer to 2 decimal points) Calotific Value is 1040 imperial and 10.76 metric?
@tomkatgastraining3 жыл бұрын
1040 and 10.76 is not the calorific value of natural gas .
@aghasahib47033 жыл бұрын
@@tomkatgastraining thanks alot for your reply. Its 10.76 when we divide it by 3.6
@tomkatgastraining3 жыл бұрын
@@aghasahib4703 you are correct with the 10.76 and that is the gross cv of natural gas but we don’t divide it by the kw we divide the amount of mega joules to give us the kw gross
@bryanwilliams38273 жыл бұрын
Great video informative
@chrisjones45002 жыл бұрын
Great!! Thanks Derek.
@zafarmahmood48774 жыл бұрын
Hi Its zafar I m student of gas engineer course. I m confused with you fingers which you mantion. YOU said For g4 gives 6 cubic miter or 212 cubic feet? Same for u6 Same for e6 And g19 you said 60 cubic miter or 265 cubic feet. And that is allowed in domidtic gas. First HOW come 6 cubic miter is equal to 212 feet? If it's write than 1 cubic miter is equal to 35.33 cubic feet? And you said g10 60 cubic meter or 265 cubic feet So here 1 cubic meter is equal to 4 41 cubic feet? And also viper book says max gas voulal for domic is 16 meter cubic Can please some one explain to me. I will wait for answer
@tomkatgastraining4 жыл бұрын
I said g10 which is 16 m3/hr not 60 it must be my Manchester accent lol
@zafarmahmood48774 жыл бұрын
@@tomkatgastraining Okay HOW many cubic feets in 1 cubic meter? 6 cubic meter equel is 212 cubic feet And 16 cubic meter is equal to 265 cubic feets? 🤔😇🤔
@tomkatgastraining4 жыл бұрын
@@zafarmahmood4877 are you telling me or asking me ?
@tomkatgastraining4 жыл бұрын
Just watched it back yeh said 2 instead of 5 think I got there in the end 👍🏻
@zafarmahmood48774 жыл бұрын
565 Know quite clear Many thanks
@siempretexican663 жыл бұрын
Are these meters in the USA
@tomkatgastraining3 жыл бұрын
Sorry I haven’t got a clue. Any gas engineers in the USA answer this question
@uklifestyle94944 жыл бұрын
Very help full video
@AhmedAhmed-zj4zd4 жыл бұрын
Hello mr Darek I appreciate all ur help Can you please do vedeo for legislation and combustion pleeaaaaaase thank you very much
@bobsmith9624 жыл бұрын
Is this us or uk?
@tomkatgastraining4 жыл бұрын
U.K.
@mianasifgujar4 жыл бұрын
Always good Teaching, Good for new Engineers like me. Thanks