Scotch-Brite Light Duty Hand Pad 6448 is your best friend for a flame sensor cleaning. Doesn't even look like they busted a knock out for any fresh air intake. Thing must be starving for air.
@CommonSenseFishing2092 ай бұрын
All safety circuits go through jack pin plug to control board. If there is any issue like a pressure switch or flame sensor or limit etc the board should mandatory throw an LED diagnostic code. So.....if it was calling for heating and has the heart beat saying normal operation call for heat but did not work and threw no code means a failed control board everytime. Easy diagnostic.
@midwestg41052 ай бұрын
Through your videos you taught me when and how to clean flame sensor. I had to do that on my Trane propane furnace yesterday. What a pain in the ass to get to but I got it done! Thanks, from Indiana, for your videos!! Even though you would probably prefer I didn't and call a professional.....
@my-yt-inputs2580Ай бұрын
I had an issue with my Trane package(gas pack) unit back in January. Super cold snap with icy roads had just started too. So getting help was at least initially out of the question. First thing I did was pull the flame sensor and clean it. Did not help. My unit was lighting the burners but instead of shutting off after only a few seconds I would get a flame for 10 -15 seconds. The unit would cycle this way for several minutes before resetting and then nothing. No error codes displayed. I pulled the flame sensor multiple times but no luck. Eventually what I determined, through trial and error, was it wasn't the flame sensor(flame rectification) itself but the flame sensor mount bracket. Enough corrosion between the unit frame and flame sensor mount bracket that it must not have had a good enough bond. I cleaned off the flame sensor mount bracket as well as the mounting area on the unit frame and that seemed to have fixed the issue. I eventually ordered a Trane replacement flame sensor that came with a nice shiny copper mount bracket and installed that one. But the issue stopped even before I installed the replacement flame sensor. Not sure why the mount bracket itself needs a ground bond since it is isolated from the flame sensor itself since it is mounted to the ceramic insulator.
@walterrifle27252 ай бұрын
4OT steel wool is a nice addition to a service kit
@RayRay-nb7tn2 ай бұрын
Glad the customer had you replace the unit. I hope you made adjustments on the exit of the exhaust off the ground. Hackers did a great job hacking that install and service calls. Now they had an educational company to rely on for future services.
@CameronKettner2 ай бұрын
Maybe I missed something, but I didn't see any of the knockouts knocked out for the combustion air intake, only the one for the exhaust.
@throttlebottle59062 ай бұрын
yeah, previous installer looked like what you'd get from the town drunk for a couple cases of beer(after drinking a case). 🤣
@rando_webb87042 ай бұрын
Suffocated flame, I ran into this situation before where the customer complained of the same problem, but when I opened the the combustion door and ran the test fire, it worked just fine. Turns out the system was running a concentric kit and the home owner owner just had the roof done. The roofers cut off the flu cap ant it was sucking exhaust into the intake.
@robalexander73482 ай бұрын
Good job Ted, and i still get a smile when you arrive at the job, and close your squeeky drivers van door 👍 Au
@natepeterson71452 ай бұрын
That furnace has a bulliten on reamin out the pressure hole port on the inducer so water doesn't get into the pressure switch tube.
@TedCookHVAC2 ай бұрын
Where you working now ?? Service or install or what??
@natepeterson71452 ай бұрын
@@TedCookHVAC I work in appliances again. I couldn't handle the overtime with my family. I'm in your neighborhood quite a bit. Hope your doing well.
@danobrien31092 ай бұрын
That exhaust looks a little funky at that first elbow Theodore. You may by correct about the pressure switch and it may clear after a reset. I’m thinking the condensate is collecting at that odd joint ( looks like it’s taped together). You’re right about ICP units being easy to work on and they are a real work horse too if installed properly. That one is not. Exhaust venting is incorrect, gas piping is suspect as well, they used a thread saver as a coupling. They also didn’t allow for enough combustion air. Those units require that there be one of the two” knock outs to be used to supply combustion air. They only knocked out the one for the exhaust. The opening for the gas line may not be adequate to provide enough air for combustion . That old control board was used in older ICP units. Knock out the other 2” knock out and your problem is solved for combustion air. You need to repair that crappy exhaust venting too.👍🇨🇦
@user-ox1mp2mo1n2 ай бұрын
Love your videos. That furnace did not have enough combustion air. When installing as a one pipe system (i never do) you still need to bust out another two inch opening and install a 90 degree elbow for combustion air. thus why it ran better with the door off. Keep up with the videos.
@zackmax71842 ай бұрын
That's why Steve Lav wears Gloves.
@billnahorn39392 ай бұрын
My flame sensor has been in my Goodman furnace for 24 years without cleaning because I don’t have a 100 dollar bill, now I know you can use a 50 I’m that much closer to cleaning it. Just need to go down 2 more bills . Thank you
@davidbates74292 ай бұрын
I bought a house that came with one of those " made in hell" Hiel furnace's. What a pain in my behind. After a year of constant calls to the repairman I had to switch. Never again would I ever have one of those units in my home again.
@teeg32752 ай бұрын
I do hate those furnaces Carrier heil tempstar Bryant payne daynnight comfort maker all the same pile of shit.
@douglashunt487Ай бұрын
Now that’s A/C money right there. Lol.
@scottmaz40632 ай бұрын
Good job Ted well done 👏
@clarksafg2 ай бұрын
Many issues with this one Ted..replacing was the best outcome for this hack job..on those Rheem designs those traps are a window to the exchanger condition as well as running it with the combination door on..if that ignition goes off, something with the venting or draining is a wrong..let me guess the customer went with the cheapest option..lol..man they get what they pay for..
@dimbag12 ай бұрын
Great video Sir.
@sknight03912 ай бұрын
That trap looked like it had the black death in it. 😎👍
@TedCookHVAC2 ай бұрын
Shoal did !!
@pelon5422 ай бұрын
i know many people are against using emery cloth but it's always worked for me
@bobgallo37752 ай бұрын
Scotch brite scouring pad works well
@realestateservicessaleshea992 ай бұрын
If people would just read the freagin instructions. 😅😂
@AToolWithTools2 ай бұрын
"Bah, I've been doing this for years" says their very untrained drunken uncle.
@rando_webb87042 ай бұрын
The install was crap but the furnace is fine. I dont see why it had to be replaced. The exaust is too long for the diameter of the pipe and termination needs to be fixed. Needs fresh air intake. And condensate line needs repair. Thats it. Other than that that furnace is working just fine.
@throttlebottle59062 ай бұрын
oh dear, they have far more issues in that place, because I spied "vanguard" brand polybutylene tubing. hopefully you guys don't even breathe on it changing the furnace, because she'll probably start leaking at every fitting and possibly in the middle of nowhere just because it can(and does). a replumb is in their future, if they well water, it will hold up longer than city water, but it's on borrowed time.
@tonybochiano29 күн бұрын
Any Coating that may have been placed on the flame sensor has been burnt off long ago
@pstiegman2 ай бұрын
Maybe carry a Magic Eraser sponge, they are 3000 grit?
@jeffreyjohn20372 ай бұрын
Supco makes a cleaning tool. FSC10
@kg4muc2 ай бұрын
Good find even better replacing the unit right in the end! BTW you racing this year?
@TedCookHVAC2 ай бұрын
Oh yea !!
@Quentyn732 ай бұрын
That trick with the middle finger and a $50 seems like had been trained before
@Firehawk8412 ай бұрын
what state is this? seems like everything there is hacked
@boeing757pilot2 ай бұрын
South Carolina, I believe
@philcore47592 ай бұрын
not seeing combustion air either
@CameronKettner2 ай бұрын
Looks like they didn't even bother to knock one of the 3 factory option holes out. Maybe they were counting on the hole they chopped for the trap to be enough.
@sknight03912 ай бұрын
😎👍
@jeffsworld22 ай бұрын
OMG a $50, how could you. Better get to the ATM before the next call, haha...
@caru32572 ай бұрын
He could use five 20s😂😂😂😂
@gerardomireles1222 ай бұрын
The helicopter 🚁
@nomusicrc2 ай бұрын
Last How is that code to have the exhaust vent that close to the ground
@TheTerriepearce2 ай бұрын
When the door is on how’s it getting any combustion air?
@danpresson2 ай бұрын
I was taught to use steel wool
@hvacjay32012 ай бұрын
Is that electrical tape on the flu pipe? 😮😂
@patmadix1722 ай бұрын
Always laughing when you only half clean but I use a dollar bill or my jeans
@SignorNessuno652 ай бұрын
It's almost like these furnaces are made to be disposable.
@RockoRocko-rz7kx2 ай бұрын
They are 20 years max
@larrysmith93592 ай бұрын
You ever left $100 bill after cleaning a flame sensor before?😊
@TedCookHVAC2 ай бұрын
NO !!
@trinito972 ай бұрын
Dont we hate crawling jobs
@japmlp09Ай бұрын
U and Lav should do a vid together
@CommonSenseFishing2092 ай бұрын
Bad control board when the board diagnostic says everything is hunkey dorey and obviously it's not. That's a bad board every time. Many other problems I'm sure.
@rolandoperez8032 ай бұрын
Hello, you never got used to the Milwaukee driver instead of the nut driver?
@justinbeam812 ай бұрын
Bad board!
@drewbush65352 ай бұрын
Any homeowner should be able to figure that out
@throttlebottle59062 ай бұрын
Anti Ted fence gate. lol
@TedCookHVAC2 ай бұрын
Yea I had to edit out the struggle.
@midaswelby86982 ай бұрын
Dude that pvc is not ok
@Anti-Groomer2 ай бұрын
What are furnaces made out of? What is heat made out of? Are furnaces the only thing preventing the heat-death of the universe?
@elkmountain1114Ай бұрын
Looks like a second grader installed that!
@Simone_from_CallRail2 ай бұрын